THTetsuo Horimatsu

Tetsuo Horimatsu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tetsuo Horimatsu has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Niacin protects against abdominal aortic aneurysm formation via GPR109A independent mechanisms: role of NAD+/nicotinamide

    by Tetsuo Horimatsu, Andra L Blomkalns, Mourad Ogbi, Mary Moses, David Kim, Sagar Patel, Nicole Gilreath, Lauren Reid, Tyler W Benson, Jonathan Pye, et al.

    Chronic adventitial and medial infiltration of immune cells play an important role in the pathogenesis of abdominal aortic aneurysms (AAAs). Nicotinic acid (niacin) was shown to inhibit atherosclerosis by activating the anti-inflammatory G protein-coupled receptor GPR109A [also known as hydroxycarboxylic acid receptor 2 (HCA2)] expressed on immune cells, blunting immune activation and adventitial inflammatory cell infiltration. Here, we investigated the role of niacin and GPR109A in regulating AAA formation. Mice were supplemented with niacin or nicotinamide, and AAA was induced by angiotensin II (AngII) infusion or calcium chloride (CaCl2) application. Niacin markedly reduced AAA formation in both AngII and CaCl2 models, diminishing adventitial immune cell infiltration, concomitant inflammatory responses, and matrix degradation. Unexpectedly, GPR109A gene deletion did not abrogate the protective effects of niacin against AAA formation, suggesting GPR109A-independent mechanisms. Interestingly, nicotinamide, which does not activate GPR109A, also inhibited AAA formation and phenocopied the effects of niacin. Mechanistically, both niacin and nicotinamide supplementation increased nicotinamide adenine dinucleotide (NAD+) levels and NAD+-dependent Sirt1 activity, which were reduced in AAA tissues. Furthermore, pharmacological inhibition of Sirt1 abrogated the protective effect of nicotinamide against AAA formation. Niacin protects against AAA formation independent of GPR109A, most likely by serving as an NAD+ precursor. Supplementation of NAD+ using nicotinamide-related biomolecules may represent an effective and well-tolerated approach to preventing or treating AAA.


  • Vascular response to paclitaxel-eluting nitinol self-expanding stent in superficial femoral artery lesions: post-implantation angioscopic findings from the SHIMEJI trial (Suppression of vascular wall Healing after IMplantation of drug Eluting peripheral stent in Japanese patients with the Infra inguinal lesion: serial angioscopic observation)

    by Yoshiro Tsukiyama, Toshiro Shinke, Takayuki Ishihara, Hiromasa Otake, Daisuke Terashita, Amane Kozuki, Masashi Fukunaga, Kan Zen, Tetsuo Horimatsu, Kenichi Fujii, et al.

    The aim of this study was to elucidate the vascular responses to paclitaxel-eluting stent (Zilver PTX stent) in superficial femoral artery lesion at different elapsed times using angioscopy. Patients who received Zilver PTX stent implantation from five centers were enrolled. We performed angioscopic examinations at 2, 6, and 12 months after implantation and evaluated neointimal coverage (NIC) grade, intra-stent thrombus (IS-Th) grade, and presence of yellow plaque. NIC grade 0 was defined as stent struts exposed; grade 1, struts transparently visible although covered; grade 2, struts embedded in the neointima, but translucent; and grade 3, struts fully embedded and invisible. IS-Th was graded as follows: grade 0 (none), 1 (focal), and 2 (diffusely spread). Angioscopic follow-up evaluation was performed at 2 months (25 patients, 42 lesions), 6 months (18 patients, 23 stents), and 12 months (14 patients, 24 stents) after stent implantation. Dominant NIC grade significantly increased over time; however, 16.3% of the cases had NIC grade 1 or 2 at 12 months. IS-Th grade decreased; however IS-Th and yellow plaque were persistently observed in 62.5% and 83.3% cases, respectively, at 12 months. An ongoing healing response was observed at 12 months after implantation; however, thrombogenic findings were noted. Prolonged dual antiplatelet therapy could potentially enhance the clinical utility of Zilver PTX.


  • Open Access

    A single high-fat meal provokes pathological erythrocyte remodeling and increases myeloperoxidase levels: implications for acute coronary syndrome

    by Tyler W Benson, Neal L Weintraub, Ha Won Kim, Nichole Seigler, Sanjiv Kumar, Jonathan Pye, Tetsuo Horimatsu, Rod Pellenberg, David W Stepp, Rudolf Lucas, et al.


  • Impact of intravascular ultrasound findings on long-term patency after self-expanding nitinol stent implantation in the iliac artery lesion

    by Kojiro Miki, Kenichi Fujii, Masashi Fukunaga, Machiko Nishimura, Tetsuo Horimatsu, Ten Saita, Hiroto Tamaru, Takahiro Imanaka, Masahiko Shibuya, Yoshiro Naito, et al.

    Although intravascular ultrasound (IVUS) predictors of stent patency for the coronary artery lesion have been established, little is known about IVUS predictors of stent patency for the aorto-iliac artery lesion. We analyzed 154 lesions of 122 patients who underwent stent implantation for iliac artery lesions. Quantitative and qualitative IVUS analyses were performed for pre- and post-procedural IVUS imaging in all lesions. Target lesion revascularization (TLR) was defined as clinically driven revascularization with >50 % angiographic stenosis of the target lesion. The mean follow-up period was 39 ± 16 months. TLRs were performed in 13 lesions (8.4 %). Post-procedural minimum stent area (MSA) was significantly smaller in the TLR group compared to the no-TLR group (16.0 ± 5.8 vs. 25.6 ± 8.5 mm(2), p < 0.001). Stent edge dissection was frequently observed in the TLR group compared to the no-TLR group (53.8 vs. 24.1 %, p = 0.04). Multivariate analysis revealed that post-procedural MSA (OR = 0.76, p < 0.01) and stent edge dissection (OR = 10.4, p < 0.01) were independent IVUS predictors of TLR. Receiver-operating characteristic analysis identified post-procedural MSA <17.8 mm(2) as the optimal cut-point for the prediction of TLR (AUC = 0.846). Post-procedural MSA and stent edge dissection could predict long-term stent patency in the iliac artery lesion. Our results propose that adequate stent enlargement without edge dissection might be important to reduce TLR in the iliac artery lesion.