Bruno Coriton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bruno Coriton has a total of 195 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Dal Molin
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
5 shared publications Jonathan H. Frank
5 shared publications- Federico Scioscioli
Institute for Plasma Science and Technology, National Research Council 3 , Milan 20125
4 shared publications - Gabriele Croci
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
4 shared publications - Marica Rebai
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
4 shared publications - Massimo Nocente
Department of Physics, University of Milano-Bicocca 1 , Milan 20126
4 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
First evaluation of the runaway electron measurement capability of the radial gamma-ray spectrometers diagnostic at ITER
Tokamak disruptions and the resulting multi-megampere beams of relativistic runaway electrons (REs) present severe machine-protection risks for ITER. While shattered pellet injection serves as the primary line of defense for mitigation, a robust diagnostic system is mandatory to evaluate the RE current and energy. This paper provides the first assessment of the RE measurement capabilities of the radial gamma-ray spectrometers (RGRS) in ITER 15 MA deuterium–tritium (DT) scenarios. Under steady-state conditions, the combined three-detector RGRS system is sensitive to RE currents as low as IRE,min ≈ 60 kA for neon densities of ≈1020m−3, which is within the requirement to make measurements every 10 ms and for currents down to 5% of the plasma current, i.e., 750 kA for a 15 MA full-power DT scenario, as well as within the desired safety limit of 150 kA. However, when accounting for the highly dynamic, millisecond-scale growth of the RE beam in realistic DT disruption scenarios, the practical detection threshold shifts into the 500 kA–4 MA range, with most scenarios having a threshold between 1 and 2 MA. We identify the post-disruption background due to the residual activation of the first wall as the primary modeling uncertainty, which, if negligible, could lower IRE,min detected by the RGRS system by up to a factor of ≈10, as expected for early DT experiments, when tritium will be injected in ITER for the first time. We also show that a single, tangential detector with a design similar to those of the RGRS could further lower the sensitivity to IRE,min by a factor of ≈60 using the current assumption about the background.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessFirst evaluation of the runaway electron measurement capability of the radial gamma-ray spectrometers diagnostic at ITER
Tokamak disruptions and the resulting multi-megampere beams of relativistic runaway electrons (REs) present severe machine-protection risks for ITER. While shattered pellet injection serves as the primary line of defense for mitigation, a robust diagnostic system is mandatory to evaluate the RE current and energy. This paper provides the first assessment of the RE measurement capabilities of the radial gamma-ray spectrometers (RGRS) in ITER 15 MA deuterium–tritium (DT) scenarios. Under steady-state conditions, the combined three-detector RGRS system is sensitive to RE currents as low as IRE,min ≈ 60 kA for neon densities of ≈1020m−3, which is within the requirement to make measurements every 10 ms and for currents down to 5% of the plasma current, i.e., 750 kA for a 15 MA full-power DT scenario, as well as within the desired safety limit of 150 kA. However, when accounting for the highly dynamic, millisecond-scale growth of the RE beam in realistic DT disruption scenarios, the practical detection threshold shifts into the 500 kA–4 MA range, with most scenarios having a threshold between 1 and 2 MA. We identify the post-disruption background due to the residual activation of the first wall as the primary modeling uncertainty, which, if negligible, could lower IRE,min detected by the RGRS system by up to a factor of ≈10, as expected for early DT experiments, when tritium will be injected in ITER for the first time. We also show that a single, tangential detector with a design similar to those of the RGRS could further lower the sensitivity to IRE,min by a factor of ≈60 using the current assumption about the background.
- Open Access
- 22 September 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Neutron-induced air activation in the ITER HRNS diagnostic enclosure: Quantitative assessment and radiological implications
- 22 September 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Open AccessNeutron-induced air activation in the ITER HRNS diagnostic enclosure: Quantitative assessment and radiological implications
- Open Access
- 15 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106045
Evaluation of neutron emission anisotropy by neutral beam injection in ITER deuterium plasmas
We have investigated neutron emission anisotropy caused by deuterium beam injection in ITER deuterium plasmas. We evaluate the double-differential emission spectrum and emission anisotropy of neutrons produced by the D(d,n) 3 He reaction, using the energetic deuteron velocity distribution function obtained by following guiding-centre orbits of test particles. We clarify the dependence of neutron emission anisotropy on the electron density and temperature. Anisotropy increases with decreasing electron density and temperature. We examine the effect of neutron emission anisotropy on the neutron incident flux distribution on the first wall. We show that neutron emission anisotropy can affect the measurements of the neutron emission rate and emission profile based on the incident flux distribution, the distribution of neutron emission anisotropy, and the correspondence relationship between the poloidal angular positions and the neutron detectors that are planned to be installed in ITER. It is inevitable to consider neutron emission anisotropy for plasma diagnostics and monitoring of the neutron generation rate in beam-injected deuterium plasmas.
- 15 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106045
Open AccessEvaluation of neutron emission anisotropy by neutral beam injection in ITER deuterium plasmas
We have investigated neutron emission anisotropy caused by deuterium beam injection in ITER deuterium plasmas. We evaluate the double-differential emission spectrum and emission anisotropy of neutrons produced by the D(d,n) 3 He reaction, using the energetic deuteron velocity distribution function obtained by following guiding-centre orbits of test particles. We clarify the dependence of neutron emission anisotropy on the electron density and temperature. Anisotropy increases with decreasing electron density and temperature. We examine the effect of neutron emission anisotropy on the neutron incident flux distribution on the first wall. We show that neutron emission anisotropy can affect the measurements of the neutron emission rate and emission profile based on the incident flux distribution, the distribution of neutron emission anisotropy, and the correspondence relationship between the poloidal angular positions and the neutron detectors that are planned to be installed in ITER. It is inevitable to consider neutron emission anisotropy for plasma diagnostics and monitoring of the neutron generation rate in beam-injected deuterium plasmas.
- Open Access
- 5 August 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (9) , 096017
Alpha particle velocity- and orbit-space sensitivity of gamma-ray spectroscopy diagnostics based on the 10 B ( α , p γ ) 13 C reaction
A key challenge on the path towards burning plasmas is the measurement of the alpha particle phase space. Among the few experimental options available, gamma-ray spectroscopy (GRS) is a key method. Previous demonstrations at Joint European Torus were based on reactions between alpha particles and beryllium as the target impurity, but this is no longer applicable, neither at ITER with a tungsten-based first wall, nor in other forthcoming burning plasma experiments. On the other hand, owing to the use of boron injection for plasma operations in tungsten devices, gamma-ray reactions between the alpha particles and boron impurities have been proposed as an alternative. This work presents the first numerical evaluation of the velocity-space and orbit-space sensitivity of boron-based GRS to the alpha particle phase space, focusing on the 10 B ( α , p γ ) 13 C reaction. Depending on the emission peak, we find that measurements can be separately sensitive to selected super- and sub-Alfvenic velocities, with an enhanced sensitivity towards particles on trapped and potato orbits, for the case of radial lines of sight. Information on co- and counter-going alphas may be accessed only by more refined spectral shape analysis or if a tangential line of sight is deployed. The results are relevant to establish a bridge between the indirect GRS measurements and the alpha particle phase space. They furthermore provide a quantitative input to determine which wave-alpha particle resonant interactions may (or may not) be measurable with boron based GRS, depending on the observation geometry.
- 5 August 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (9) , 096017
Open AccessAlpha particle velocity- and orbit-space sensitivity of gamma-ray spectroscopy diagnostics based on the 10 B ( α , p γ ) 13 C reaction
A key challenge on the path towards burning plasmas is the measurement of the alpha particle phase space. Among the few experimental options available, gamma-ray spectroscopy (GRS) is a key method. Previous demonstrations at Joint European Torus were based on reactions between alpha particles and beryllium as the target impurity, but this is no longer applicable, neither at ITER with a tungsten-based first wall, nor in other forthcoming burning plasma experiments. On the other hand, owing to the use of boron injection for plasma operations in tungsten devices, gamma-ray reactions between the alpha particles and boron impurities have been proposed as an alternative. This work presents the first numerical evaluation of the velocity-space and orbit-space sensitivity of boron-based GRS to the alpha particle phase space, focusing on the 10 B ( α , p γ ) 13 C reaction. Depending on the emission peak, we find that measurements can be separately sensitive to selected super- and sub-Alfvenic velocities, with an enhanced sensitivity towards particles on trapped and potato orbits, for the case of radial lines of sight. Information on co- and counter-going alphas may be accessed only by more refined spectral shape analysis or if a tangential line of sight is deployed. The results are relevant to establish a bridge between the indirect GRS measurements and the alpha particle phase space. They furthermore provide a quantitative input to determine which wave-alpha particle resonant interactions may (or may not) be measurable with boron based GRS, depending on the observation geometry.
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Monte-Carlo Simulation of Gamma-Ray Background in the ITER Radial Gamma-Ray Spectrometer
The ITER Radial Gamma Ray Spectrometer (RGRS) is a high-performance diagnostic instrument designed to measure gamma radiation emitted by the plasma in the ITER tokamak fusion reactor. RGRS will have three dedicated radial lines of sight plus one shared with the Radial Neutron Camera, and uses LaBr3 scintillator detectors to record gamma-ray spectra for the study of fast ions, the monitoring of runaway electrons, and the measurement of fusion power. A critical challenge in the operation of RGRS will be the characterisation of the gamma-ray background reaching the detectors, which is required to improve diagnostic design, correctly interpret detector spectra and assess diagnostic performance. This work presents MCNP Monte Carlo simulations of the gamma-ray background in RGRS, employing a two-step simulation approach to isolate and quantify the dominant background contributions. Results indicate that neutron-induced gamma-rays from the central column will be the primary background source, exceeding by nearly one order of magnitude all other contributions along the line of sight, with direct implications for the detector count rate and the signal-to-background ratio during full-power ITER operation.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMonte-Carlo Simulation of Gamma-Ray Background in the ITER Radial Gamma-Ray Spectrometer
The ITER Radial Gamma Ray Spectrometer (RGRS) is a high-performance diagnostic instrument designed to measure gamma radiation emitted by the plasma in the ITER tokamak fusion reactor. RGRS will have three dedicated radial lines of sight plus one shared with the Radial Neutron Camera, and uses LaBr3 scintillator detectors to record gamma-ray spectra for the study of fast ions, the monitoring of runaway electrons, and the measurement of fusion power. A critical challenge in the operation of RGRS will be the characterisation of the gamma-ray background reaching the detectors, which is required to improve diagnostic design, correctly interpret detector spectra and assess diagnostic performance. This work presents MCNP Monte Carlo simulations of the gamma-ray background in RGRS, employing a two-step simulation approach to isolate and quantify the dominant background contributions. Results indicate that neutron-induced gamma-rays from the central column will be the primary background source, exceeding by nearly one order of magnitude all other contributions along the line of sight, with direct implications for the detector count rate and the signal-to-background ratio during full-power ITER operation.
- Open Access
- 13 July 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086015
Calibration strategy and uncertainty analysis of the ITER neutron activation system for deuterium–deuterium plasma operation *
The International Thermonuclear Experimental Reactor (ITER) neutron activation system (NAS) is an essential diagnostic system designed to measure the total neutron yield and the first-wall fluence in the ITER Tokamak. NAS principle is based on the neutron activation of small sample materials placed in the vicinity of the plasma using pneumatic transfer lines. The induced activity in the samples is subsequently measured using a gamma-ray counting station, enabling reconstruction of the total neutron yield. Accurate neutron transport modelling of both the NAS apparatus and the tokamak is essential for reliable measurements. This study systematically quantifies the primary sources of uncertainty in the NAS neutronic model, focusing on the geometric modelling of the NAS irradiation ends and tokamak environment, as well as uncertainties in nuclear data. Results indicate that the NAS can achieve a measurement accuracy of approximately 13% in deuterium–deuterium (DD) plasmas, with the largest uncertainty attributed to the detailed geometry of the diagnostic first-wall (DFW). To address this, in-situ calibration is paramount to identify unforeseen measurement errors and to mitigate the uncertainties in computational models. Utilizing a well-characterized neutron generator for NAS calibration could reduce the neutron yield measurement errors below 8%. These findings underscore the importance of precise modelling and calibration procedures for accurate neutron measurements during ITER’s start of research operation (SRO).
- 13 July 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086015
Open AccessCalibration strategy and uncertainty analysis of the ITER neutron activation system for deuterium–deuterium plasma operation *
The International Thermonuclear Experimental Reactor (ITER) neutron activation system (NAS) is an essential diagnostic system designed to measure the total neutron yield and the first-wall fluence in the ITER Tokamak. NAS principle is based on the neutron activation of small sample materials placed in the vicinity of the plasma using pneumatic transfer lines. The induced activity in the samples is subsequently measured using a gamma-ray counting station, enabling reconstruction of the total neutron yield. Accurate neutron transport modelling of both the NAS apparatus and the tokamak is essential for reliable measurements. This study systematically quantifies the primary sources of uncertainty in the NAS neutronic model, focusing on the geometric modelling of the NAS irradiation ends and tokamak environment, as well as uncertainties in nuclear data. Results indicate that the NAS can achieve a measurement accuracy of approximately 13% in deuterium–deuterium (DD) plasmas, with the largest uncertainty attributed to the detailed geometry of the diagnostic first-wall (DFW). To address this, in-situ calibration is paramount to identify unforeseen measurement errors and to mitigate the uncertainties in computational models. Utilizing a well-characterized neutron generator for NAS calibration could reduce the neutron yield measurement errors below 8%. These findings underscore the importance of precise modelling and calibration procedures for accurate neutron measurements during ITER’s start of research operation (SRO).
- Open Access
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086049
Features of fusion power measurements in the next generation magnetic plasma confinement experiments
Fusion power measurements provide one of the key benchmarks for every successful reactor-scale magnetic confinement fusion facility. Neutrons carry outside of the plasma volume 4/5 of the produced fusion power in case of deuterium-tritium fuel mix. Thus, measurement of 14-MeV neutron yield is the primary direct measurement of the fusion power of the machine. The challenge of determining the uncertainty of the total neutron yield measurement is solved using several strategies: detailed detector assessment in the metrological neutron laboratory, in-situ calibration using a mobile neutron source (typically - 252Cf) and cross-calibration using a well characterized detector in well-known discharge. Transition to reactor-scale devices such as BEST, ITER, DEMO, etc. will require the use of neutron sources with yields of 1e10-1e11 s-1 and above. Multiple diagnostics systems fall in the scope - neutron counters, neutron activation system and multi-collimator systems. Together they provide fusion power measurement with up to 10% accuracy and 1 ms time resolution for the case of ITER, in a broad dynamic range of fusion power. Two methods for in situ calibration are considered: 1) utilizing multiple NG positions to emulate circular or ‘ring’ source of fusion neutrons for calibration of the permanent detector set, and 2) making use of multiple temporary detectors located in numerous locations inside the vacuum vessel for the period of the calibration, thus allowing to obtain more reference points for further Monte-Carlo model validation with the same (or less) irradiation duration. The work details results of neutron detector characterization activity in laboratory conditions with the use of compact NGs, showing that the use of powerful (up to 1e11 s-1 D-T, 1e9 s-1 D-D) yet compact NGs with sealed tubes raises a challenge of a steady source metrological assurance, especially when considering said sources for the task of in-situ calibration.
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086049
Open AccessFeatures of fusion power measurements in the next generation magnetic plasma confinement experiments
Fusion power measurements provide one of the key benchmarks for every successful reactor-scale magnetic confinement fusion facility. Neutrons carry outside of the plasma volume 4/5 of the produced fusion power in case of deuterium-tritium fuel mix. Thus, measurement of 14-MeV neutron yield is the primary direct measurement of the fusion power of the machine. The challenge of determining the uncertainty of the total neutron yield measurement is solved using several strategies: detailed detector assessment in the metrological neutron laboratory, in-situ calibration using a mobile neutron source (typically - 252Cf) and cross-calibration using a well characterized detector in well-known discharge. Transition to reactor-scale devices such as BEST, ITER, DEMO, etc. will require the use of neutron sources with yields of 1e10-1e11 s-1 and above. Multiple diagnostics systems fall in the scope - neutron counters, neutron activation system and multi-collimator systems. Together they provide fusion power measurement with up to 10% accuracy and 1 ms time resolution for the case of ITER, in a broad dynamic range of fusion power. Two methods for in situ calibration are considered: 1) utilizing multiple NG positions to emulate circular or ‘ring’ source of fusion neutrons for calibration of the permanent detector set, and 2) making use of multiple temporary detectors located in numerous locations inside the vacuum vessel for the period of the calibration, thus allowing to obtain more reference points for further Monte-Carlo model validation with the same (or less) irradiation duration. The work details results of neutron detector characterization activity in laboratory conditions with the use of compact NGs, showing that the use of powerful (up to 1e11 s-1 D-T, 1e9 s-1 D-D) yet compact NGs with sealed tubes raises a challenge of a steady source metrological assurance, especially when considering said sources for the task of in-situ calibration.
- Open Access
- 9 June 2026
- Published by Elsevier in SSRN Electronic Journal
Neutron-induced air activation in the ITER HRNS diagnostic enclosure: quantitative assessment and radiological implications
Future fusion devices, such as ITER, will operate under intense 14 MeV neutron fluxes that may induce activation of air in diagnostic and service environments. This study presents a quantitative assessment of neutron-induced airborne activation in the High Resolution Neutron Spectrometer (HRNS) enclosure (Cuboid 2). The analysis is based on a standalone MCNP neutron transport model employing a secondary DT neutron source, followed by activation calculations performed with FISPACT-II.The resulting neutron spectrum was used to evaluate radionuclide inventories for representative DT irradiation conditions corresponding to the ITER DT-2 safety irradiation scenario. The post-shutdown inventory is dominated by short-lived radionuclides, primarily ¹⁶N and ¹³N, while repeated irradiation leads to partial accumulation of ⁴¹Ar. At longer cooling times, the airborne activity is governed mainly by ³H, with smaller contributions from ¹⁴C and ³⁹Ar.A conservative radiological assessment was performed assuming no credit for ventilation or detritiation systems. Under these deliberately conservative conditions, all predicted airborne radionuclide concentrations remain well below the ICRP Derived Air Concentration (DAC) limits. Tritium represents the largest contributor, reaching approximately 2.6 × 10⁻2 of its DAC value.The analysis further indicates that air exchange processes can significantly enhance the removal of airborne radionuclides, particularly for medium-lived species such as ⁴¹Ar. The results demonstrate that neutron-induced air activation in the HRNS enclosure does not constitute a radiological constraint for ITER operation and provide a modelling framework for the assessment of airborne activation in other neutron-exposed diagnostic systems.
- 9 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNeutron-induced air activation in the ITER HRNS diagnostic enclosure: quantitative assessment and radiological implications
Future fusion devices, such as ITER, will operate under intense 14 MeV neutron fluxes that may induce activation of air in diagnostic and service environments. This study presents a quantitative assessment of neutron-induced airborne activation in the High Resolution Neutron Spectrometer (HRNS) enclosure (Cuboid 2). The analysis is based on a standalone MCNP neutron transport model employing a secondary DT neutron source, followed by activation calculations performed with FISPACT-II.The resulting neutron spectrum was used to evaluate radionuclide inventories for representative DT irradiation conditions corresponding to the ITER DT-2 safety irradiation scenario. The post-shutdown inventory is dominated by short-lived radionuclides, primarily ¹⁶N and ¹³N, while repeated irradiation leads to partial accumulation of ⁴¹Ar. At longer cooling times, the airborne activity is governed mainly by ³H, with smaller contributions from ¹⁴C and ³⁹Ar.A conservative radiological assessment was performed assuming no credit for ventilation or detritiation systems. Under these deliberately conservative conditions, all predicted airborne radionuclide concentrations remain well below the ICRP Derived Air Concentration (DAC) limits. Tritium represents the largest contributor, reaching approximately 2.6 × 10⁻2 of its DAC value.The analysis further indicates that air exchange processes can significantly enhance the removal of airborne radionuclides, particularly for medium-lived species such as ⁴¹Ar. The results demonstrate that neutron-induced air activation in the HRNS enclosure does not constitute a radiological constraint for ITER operation and provide a modelling framework for the assessment of airborne activation in other neutron-exposed diagnostic systems.
- Open Access
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Operational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- 1 May 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5) , 055032
Open AccessOperational domain estimation of a gamma-ray spectrometer for deuterium–tritium fusion power measurement at ITER
ITER will be equipped with two types of diagnostics for fusion power measurement in deuterium–tritium plasmas: neutron flux monitors and neutron cameras, both absolutely counting the 14 MeV neutrons emitted by the D(T, 4 He)n reaction. The radial gamma-ray spectrometer (RGRS), though, has recently been considered as an additional fusion power diagnostic, detecting 17 MeV gamma-rays emitted by the radiative D(T, 5 He) γ channel of the DT reaction. This work describes the RGRS performance by determining the upper limit of its operational domain, strictly correlated with the expected background intensity and resulting between 2.6 ⋅ 10 17 neutrons per second and 3.2 ⋅ 10 18 neutrons per second. Based on this assessment, design optimization are introduced to fit the RGRS performances to the ITER requirements for safety-relevant fusion power measurements, for which the required operational range is between 2.4 ⋅ 10 19 neutrons per second and 3.2 ⋅ 10 20 neutrons per second. The expected different energy ranges covered by signal and background are exploited with the employment of a proper gamma-ray attenuator, allowing to widen and shift the RGRS operational domain toward the most relevant, high power plasma scenarios.
- Open Access
- 10 October 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (11) , 113001
Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation
This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 1015 cm−2, radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.
- 10 October 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (11) , 113001
Open AccessDiagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation
This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 1015 cm−2, radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.