Majid Hejazian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Majid Hejazian has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Nam-Trung Nguyen
Griffith University
10 shared publications - Brian Abbey
La Trobe Institute for Molecular Science, La Trobe University, Bundoora, VIC 3086, Australia
5 shared publications - Eugeniu Balaur
La Trobe University
5 shared publications Mostafa Keshavarz Moraveji
4 shared publicationsAlireza Beheshti
Department of Chemical Engineering, Faculty of Engineering , Arak University , Arak , Iran
3 shared publications- Connie Darmanin
La Trobe Institute for Molecular Science, Department of Mathematical and Physical Sciences, School of Computing Engineering and Mathematical Science, La Trobe University, Bundoora, VIC 3086, Australia
3 shared publications
Latest Publications
- Open Access
- 21 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 602-614
Observations of phase changes in monoolein during high viscous injection
Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.
- 21 March 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 602-614
Open AccessObservations of phase changes in monoolein during high viscous injection
Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.
- Open Access
- 7 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 531
Recent Advances and Future Perspectives on Microfluidic Mix-and-Jet Sample Delivery Devices
The integration of the Gas Dynamic Virtual Nozzle (GDVN) and microfluidic technologies has proven to be a promising sample delivery solution for biomolecular imaging studies and has the potential to be transformative for a range of applications in physics, biology, and chemistry. Here, we review the recent advances in the emerging field of microfluidic mix-and-jet sample delivery devices for the study of biomolecular reaction dynamics. First, we introduce the key parameters and dimensionless numbers involved in their design and characterisation. Then we critically review the techniques used to fabricate these integrated devices and discuss their advantages and disadvantages. We then summarise the most common experimental methods used for the characterisation of both the mixing and jetting components. Finally, we discuss future perspectives on the emerging field of microfluidic mix-and-jet sample delivery devices. In summary, this review aims to introduce this exciting new topic to the wider microfluidics community and to help guide future research in the field.
- 7 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 531
Open AccessRecent Advances and Future Perspectives on Microfluidic Mix-and-Jet Sample Delivery Devices
The integration of the Gas Dynamic Virtual Nozzle (GDVN) and microfluidic technologies has proven to be a promising sample delivery solution for biomolecular imaging studies and has the potential to be transformative for a range of applications in physics, biology, and chemistry. Here, we review the recent advances in the emerging field of microfluidic mix-and-jet sample delivery devices for the study of biomolecular reaction dynamics. First, we introduce the key parameters and dimensionless numbers involved in their design and characterisation. Then we critically review the techniques used to fabricate these integrated devices and discuss their advantages and disadvantages. We then summarise the most common experimental methods used for the characterisation of both the mixing and jetting components. Finally, we discuss future perspectives on the emerging field of microfluidic mix-and-jet sample delivery devices. In summary, this review aims to introduce this exciting new topic to the wider microfluidics community and to help guide future research in the field.
- Open Access
- 10 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3404
A Numerical Study of Sub-Millisecond Integrated Mix-and-Inject Microfluidic Devices for Sample Delivery at Synchrotron and XFELs
Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.
- 10 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3404
Open AccessA Numerical Study of Sub-Millisecond Integrated Mix-and-Inject Microfluidic Devices for Sample Delivery at Synchrotron and XFELs
Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.
- Open Access
- 8 February 2021
- Published by MDPI AG in Preprints.org
Sub-Millisecond Integrated Mix-and-Inject Microfluidic Sample Delivery Devices
Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.
- 8 February 2021
- Published by MDPI AG in Preprints.org
Open AccessSub-Millisecond Integrated Mix-and-Inject Microfluidic Sample Delivery Devices
Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.
- Open Access
- 21 April 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (27) , 15694-15701
Mixing and jetting analysis using continuous flow microfluidic sample delivery devices
Serial femtosecond crystallography (SFX) methods used at X-ray free electron lasers (XFELs) offer a range of new opportunities for structural biology. A crucial component of SFX experiments is sample delivery. Microfluidic devices can be employed in SFX experiments to precisely deliver microcrystals to the X-ray beam and to trigger molecular dynamics via rapid mix-and-inject measurements. Here, for the first time, we have developed a process based on high-resolution photolithography using SU8 on glass to fabricate microfluidic mix-and-inject devices. In order to characterise these devices a broad range of flow rates are used and the mixing and jetting response of the devices monitored. We observe that a stable jet is formed using these devices when injecting DI-water. Three different jetting regimes, liquid column, ribbon, and cylindrical jet, were observed. Furthermore, fluorescence experiments confirm that rapid and uniform mixing of the two injected solutions is possible using these devices indicating that they could be used to probe molecular dynamics on sub-microsecond timescales.
- 21 April 2020
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 10 (27) , 15694-15701
Open AccessMixing and jetting analysis using continuous flow microfluidic sample delivery devices
Serial femtosecond crystallography (SFX) methods used at X-ray free electron lasers (XFELs) offer a range of new opportunities for structural biology. A crucial component of SFX experiments is sample delivery. Microfluidic devices can be employed in SFX experiments to precisely deliver microcrystals to the X-ray beam and to trigger molecular dynamics via rapid mix-and-inject measurements. Here, for the first time, we have developed a process based on high-resolution photolithography using SU8 on glass to fabricate microfluidic mix-and-inject devices. In order to characterise these devices a broad range of flow rates are used and the mixing and jetting response of the devices monitored. We observe that a stable jet is formed using these devices when injecting DI-water. Three different jetting regimes, liquid column, ribbon, and cylindrical jet, were observed. Furthermore, fluorescence experiments confirm that rapid and uniform mixing of the two injected solutions is possible using these devices indicating that they could be used to probe molecular dynamics on sub-microsecond timescales.
- 1 June 2019
- Published by AIP Publishing in Physics of Fluids
- Vol. 31 (6) , 063603
Modeling of mass transfer enhancement in a magnetofluidic micromixer
The use of magnetism for various microfluidic functions such as separation, mixing, and pumping has been attracting great interest from the research community as this concept is simple, effective, and of low cost. Magnetic control avoids common problems of active microfluidic manipulation such as heat, surface charge, and high ionic concentration. The majority of past works on micromagnetofluidic devices were experimental, and a comprehensive numerical model to simulate the fundamental transport phenomena in these devices is still lacking. The present study aims to develop a numerical model to simulate transport phenomena in microfluidic devices with ferrofluid and fluorescent dye induced by a nonuniform magnetic field. The numerical results were validated by experimental data from our previous work, indicating a significant increase in mass transfer. The model shows a reasonable agreement with experimental data for the concentration distribution of both magnetic and nonmagnetic species. Magnetoconvective secondary flow enhances the transport of nonmagnetic fluorescent dye. A subsequent parametric analysis investigated the effect of the magnetic field strength and nanoparticle size on the mass transfer process. Mass transport of the fluorescent dye is enhanced with increasing field strength and size of magnetic particles.
- 1 June 2019
- Published by AIP Publishing in Physics of Fluids
- Vol. 31 (6) , 063603
Modeling of mass transfer enhancement in a magnetofluidic micromixer
The use of magnetism for various microfluidic functions such as separation, mixing, and pumping has been attracting great interest from the research community as this concept is simple, effective, and of low cost. Magnetic control avoids common problems of active microfluidic manipulation such as heat, surface charge, and high ionic concentration. The majority of past works on micromagnetofluidic devices were experimental, and a comprehensive numerical model to simulate the fundamental transport phenomena in these devices is still lacking. The present study aims to develop a numerical model to simulate transport phenomena in microfluidic devices with ferrofluid and fluorescent dye induced by a nonuniform magnetic field. The numerical results were validated by experimental data from our previous work, indicating a significant increase in mass transfer. The model shows a reasonable agreement with experimental data for the concentration distribution of both magnetic and nonmagnetic species. Magnetoconvective secondary flow enhances the transport of nonmagnetic fluorescent dye. A subsequent parametric analysis investigated the effect of the magnetic field strength and nanoparticle size on the mass transfer process. Mass transport of the fluorescent dye is enhanced with increasing field strength and size of magnetic particles.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10875, 108750D
Microfluidic mixing and jetting devices based on SU8 and glass for time-resolved molecular imaging experiments
The development of ultrafast X-ray free-electron laser (XFEL) sources and third-generation synchrotrons has opened many new horizons for the study of complex molecular structures and their reaction kinetics. An essential element of these types of experiment is the method used for sample delivery. Microfluidics technology provides the ideal platform for performing these types of measurements since it enables control, manipulation and delivery of small volumes of fluid inside microchannels. Several key functions including mixing, particle separation, and injection, can be integrated on a single chip making the technology very attractive for use in Xray characterisation of molecular dynamics. Key challenges however, in using microfluidics to both mix and deliver samples, include chemical inertness and mechanical stability of the devices, particularly at micron length scales. Here we report a repeatable method for fabricating microfluidic mixer-jet devices based on photolithography and SU8 with a glass substrate. In experiments we have shown that these devices can withstand the high gas pressures required to produce stable, long-range, liquid jets. Coupled with their chemical inertness and reproducibility this makes them promising candidates for time-resolved X-ray diffraction measurements of molecular dynamics. Incorporating an integrated serpentine micromixer capable of homogeneous mixing prior to the liquid jet the devices presented here can be applied to the study of the dynamics of chemically driven biomolecular reactions. The focus of the current work is on the experimental characterization of the mixer through analysis of the concentration profiles along the length of the serpentineshaped microchannel.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10875, 108750D
Microfluidic mixing and jetting devices based on SU8 and glass for time-resolved molecular imaging experiments
The development of ultrafast X-ray free-electron laser (XFEL) sources and third-generation synchrotrons has opened many new horizons for the study of complex molecular structures and their reaction kinetics. An essential element of these types of experiment is the method used for sample delivery. Microfluidics technology provides the ideal platform for performing these types of measurements since it enables control, manipulation and delivery of small volumes of fluid inside microchannels. Several key functions including mixing, particle separation, and injection, can be integrated on a single chip making the technology very attractive for use in Xray characterisation of molecular dynamics. Key challenges however, in using microfluidics to both mix and deliver samples, include chemical inertness and mechanical stability of the devices, particularly at micron length scales. Here we report a repeatable method for fabricating microfluidic mixer-jet devices based on photolithography and SU8 with a glass substrate. In experiments we have shown that these devices can withstand the high gas pressures required to produce stable, long-range, liquid jets. Coupled with their chemical inertness and reproducibility this makes them promising candidates for time-resolved X-ray diffraction measurements of molecular dynamics. Incorporating an integrated serpentine micromixer capable of homogeneous mixing prior to the liquid jet the devices presented here can be applied to the study of the dynamics of chemically driven biomolecular reactions. The focus of the current work is on the experimental characterization of the mixer through analysis of the concentration profiles along the length of the serpentineshaped microchannel.
- Open Access
- 12 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 186
Recent Advances and Future Perspectives on Microfluidic Liquid Handling
The interdisciplinary research field of microfluidics has the potential to revolutionize current technologies that require the handling of a small amount of fluid, a fast response, low costs and automation. Microfluidic platforms that handle small amounts of liquid have been categorised as continuous-flow microfluidics and digital microfluidics. The first part of this paper discusses the recent advances of the two main and opposing applications of liquid handling in continuous-flow microfluidics: mixing and separation. Mixing and separation are essential steps in most lab-on-a-chip platforms, as sample preparation and detection are required for a variety of biological and chemical assays. The second part discusses the various digital microfluidic strategies, based on droplets and liquid marbles, for the manipulation of discrete microdroplets. More advanced digital microfluidic devices combining electrowetting with other techniques are also introduced. The applications of the emerging field of liquid-marble-based digital microfluidics are also highlighted. Finally, future perspectives on microfluidic liquid handling are discussed.
- 12 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 186
Open AccessRecent Advances and Future Perspectives on Microfluidic Liquid Handling
The interdisciplinary research field of microfluidics has the potential to revolutionize current technologies that require the handling of a small amount of fluid, a fast response, low costs and automation. Microfluidic platforms that handle small amounts of liquid have been categorised as continuous-flow microfluidics and digital microfluidics. The first part of this paper discusses the recent advances of the two main and opposing applications of liquid handling in continuous-flow microfluidics: mixing and separation. Mixing and separation are essential steps in most lab-on-a-chip platforms, as sample preparation and detection are required for a variety of biological and chemical assays. The second part discusses the various digital microfluidic strategies, based on droplets and liquid marbles, for the manipulation of discrete microdroplets. More advanced digital microfluidic devices combining electrowetting with other techniques are also introduced. The applications of the emerging field of liquid-marble-based digital microfluidics are also highlighted. Finally, future perspectives on microfluidic liquid handling are discussed.
- Open Access
- 1 February 2017
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 81, 149-154
Magnetofluidics for manipulation of convective heat transfer
- 1 February 2017
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 81, 149-154
Open AccessMagnetofluidics for manipulation of convective heat transfer
- Open Access
- 25 January 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (2) , 37
A Rapid Magnetofluidic Micromixer Using Diluted Ferrofluid
Effective and rapid mixing is essential for various chemical and biological assays. The present work describes a simple and low-cost micromixer based on magnetofluidic actuation. The device takes advantage of magnetoconvective secondary flow, a bulk flow induced by an external magnetic field, for mixing. A superparamagnetic stream of diluted ferrofluid and a non-magnetic stream are introduced to a straight microchannel. A permanent magnet placed next to the microchannel induced a non-uniform magnetic field. The magnetic field gradient and the mismatch in magnetic susceptibility between the two streams create a body force, which leads to rapid and efficient mixing. The micromixer reported here could achieve a high throughput and a high mixing efficiency of 88% in a relatively short microchannel.
- 25 January 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (2) , 37
Open AccessA Rapid Magnetofluidic Micromixer Using Diluted Ferrofluid
Effective and rapid mixing is essential for various chemical and biological assays. The present work describes a simple and low-cost micromixer based on magnetofluidic actuation. The device takes advantage of magnetoconvective secondary flow, a bulk flow induced by an external magnetic field, for mixing. A superparamagnetic stream of diluted ferrofluid and a non-magnetic stream are introduced to a straight microchannel. A permanent magnet placed next to the microchannel induced a non-uniform magnetic field. The magnetic field gradient and the mismatch in magnetic susceptibility between the two streams create a body force, which leads to rapid and efficient mixing. The micromixer reported here could achieve a high throughput and a high mixing efficiency of 88% in a relatively short microchannel.