Odd Viking Höglund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Odd Viking Höglund has a total of 172 co-authors. Here are the top co-authors by number of shared publications:
- Ann Pettersson
Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
11 shared publications - Ragnvi Hagman
Department of Clinical Sciences, Swedish University of Agricultural Sciences, PO Box 7054, Uppsala SE-75007, Sweden
10 shared publications - Jeanette M. Hanson
Department of Clinical Sciences, Swedish University of Agricultural Sciences (SLU), Uppsala, Sweden
9 shared publications - Mats Stridsberg
Department of Medical Sciences, Uppsala University, Uppsala, Sweden
9 shared publications Ragnvi Hagman
Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
9 shared publications- Anne-Sofie Lagerstedt
Department of Clinical Sciences, Swedish University of Agricultural Sciences, Box 7054, SE 75007, Uppsala, Sweden
6 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by Wiley in Veterinary Surgery
A virtual reality‐based test for assessing laparoscopic canine ovariectomy competency: A validity study
Objective: Simulation‐based training can be used to develop basic laparoscopic skills. Proficiency‐based training is the gold standard but requires competency assessment. This study investigated validity evidence for a virtual reality simulator‐based test assessing laparoscopic canine ovariectomy skills. Study design: Validity investigation study. Sample population: Eleven surgeons with experience of at least 30 laparoscopic canine ovariectomies, and 16 novices with no laparoscopic experience. Methods: Participants completed three attempts on both the left and right sides of the LapSim Canine Ovariectomy simulator module. Data were collected automatically, and the second and third attempts were analyzed. Discriminatory parameters were identified, and pass/fail levels were determined using the contrasting groups method. A noncompensatory standard‐setting method was used. Validity evidence was reported using Messick's framework. Results: Experienced surgeons were faster (total time, p = .008) and used fewer instrument movements than novices (combined instrument path length, p = .031; combined instrument angular path, p = .038). A test was developed for the module's left side and relevant pass/fail levels identified. Approximately half of the novices and one experienced surgeon failed the test. Test–retest analysis indicated generally low reliability. Conclusion: This study provided validity evidence for a virtual reality simulator‐based test assessing competency in laparoscopic canine ovariectomy. The test can currently be used for formative assessment during training. Clinical significance: Virtual reality simulation is an emerging field in veterinary medicine with the potential to enhance surgical training. These findings can inform the incorporation of proficiency‐based virtual reality training into veterinary curricula.
- 18 November 2026
- Published by Wiley in Veterinary Surgery
Open AccessA virtual reality‐based test for assessing laparoscopic canine ovariectomy competency: A validity study
Objective: Simulation‐based training can be used to develop basic laparoscopic skills. Proficiency‐based training is the gold standard but requires competency assessment. This study investigated validity evidence for a virtual reality simulator‐based test assessing laparoscopic canine ovariectomy skills. Study design: Validity investigation study. Sample population: Eleven surgeons with experience of at least 30 laparoscopic canine ovariectomies, and 16 novices with no laparoscopic experience. Methods: Participants completed three attempts on both the left and right sides of the LapSim Canine Ovariectomy simulator module. Data were collected automatically, and the second and third attempts were analyzed. Discriminatory parameters were identified, and pass/fail levels were determined using the contrasting groups method. A noncompensatory standard‐setting method was used. Validity evidence was reported using Messick's framework. Results: Experienced surgeons were faster (total time, p = .008) and used fewer instrument movements than novices (combined instrument path length, p = .031; combined instrument angular path, p = .038). A test was developed for the module's left side and relevant pass/fail levels identified. Approximately half of the novices and one experienced surgeon failed the test. Test–retest analysis indicated generally low reliability. Conclusion: This study provided validity evidence for a virtual reality simulator‐based test assessing competency in laparoscopic canine ovariectomy. The test can currently be used for formative assessment during training. Clinical significance: Virtual reality simulation is an emerging field in veterinary medicine with the potential to enhance surgical training. These findings can inform the incorporation of proficiency‐based virtual reality training into veterinary curricula.
- Open Access
- 16 October 2026
- Published by Springer Nature in BMC Veterinary Research
- Vol. 22 (1)
Use of plasma chromogranin a epitopes vasostatin and catestatin as biomarkers for catecholamine-producing tumours in dogs
Background: Differentiation of catecholamine-producing tumours from other adrenal tumours remains difficult. Chromogranin A (CgA) is a marker for catecholamine secretion in the body. An assay for quantification of the CgA epitopes vasostatin and catestatin has been validated for use in dogs but not yet evaluated in dogs with catecholamine-producing tumours. The aims were to evaluate the assays foranalysis of plasma concentrations of the CgA epitopes vasostatin and catestatin in dogs with adrenal tumours and to compare concentrations between catecholamine-producing tumours and adrenocortical tumours in dogs that were subjected to adrenalectomy. Twelve dogs with histopathologically confirmed catecholamine-secreting tumours (eleven pheochromocytomas (PCCs), one extra-adrenal sympathetic paraganglioma (PGL)) and twelve with adrenocortical tumours were included in the study. Plasma concentrations of the CgA epitopes vasostatin and catestatin were determined byradioimmunoassay (RIA), before adrenalectomy in 23 out of 24 dogs and after adrenalectomy in six of the dogs with catecholamine-secreting tumours (five PCC, one PGL). Tumour diagnosis was made by histopathology in all cases. Results: Overall, median plasma concentration of the CgA epitopevasostatin in dogs with catecholamine-secreting tumours was 0.82 nmol/L (interquartile range (IQR) 0.52 to 1.60 nmol/L), which was significantly higher(Wilcoxon rank sum exact test, P= 0.0374) than the vasostatin concentration in adrenocortical tumours (median 0.50; IQR 0.34 to 0.59 nmol/L). A subsetof dogs (5/12) with catecholamine-secreting tumours had elevated plasma vasostatin concentrations preoperatively. After successful surgery, thepreoperatively elevated plasma vasostatin concentrations decreased numerically, however without reaching statistical significance. Catestatin concentrationdid not differ between tumour types. Conclusions: Elevated plasma concentration of the CgA epitope vasostatin showed potential as a biomarker for asubset of catecholamine-secreting tumours.
- 16 October 2026
- Published by Springer Nature in BMC Veterinary Research
- Vol. 22 (1)
Open AccessUse of plasma chromogranin a epitopes vasostatin and catestatin as biomarkers for catecholamine-producing tumours in dogs
Background: Differentiation of catecholamine-producing tumours from other adrenal tumours remains difficult. Chromogranin A (CgA) is a marker for catecholamine secretion in the body. An assay for quantification of the CgA epitopes vasostatin and catestatin has been validated for use in dogs but not yet evaluated in dogs with catecholamine-producing tumours. The aims were to evaluate the assays foranalysis of plasma concentrations of the CgA epitopes vasostatin and catestatin in dogs with adrenal tumours and to compare concentrations between catecholamine-producing tumours and adrenocortical tumours in dogs that were subjected to adrenalectomy. Twelve dogs with histopathologically confirmed catecholamine-secreting tumours (eleven pheochromocytomas (PCCs), one extra-adrenal sympathetic paraganglioma (PGL)) and twelve with adrenocortical tumours were included in the study. Plasma concentrations of the CgA epitopes vasostatin and catestatin were determined byradioimmunoassay (RIA), before adrenalectomy in 23 out of 24 dogs and after adrenalectomy in six of the dogs with catecholamine-secreting tumours (five PCC, one PGL). Tumour diagnosis was made by histopathology in all cases. Results: Overall, median plasma concentration of the CgA epitopevasostatin in dogs with catecholamine-secreting tumours was 0.82 nmol/L (interquartile range (IQR) 0.52 to 1.60 nmol/L), which was significantly higher(Wilcoxon rank sum exact test, P= 0.0374) than the vasostatin concentration in adrenocortical tumours (median 0.50; IQR 0.34 to 0.59 nmol/L). A subsetof dogs (5/12) with catecholamine-secreting tumours had elevated plasma vasostatin concentrations preoperatively. After successful surgery, thepreoperatively elevated plasma vasostatin concentrations decreased numerically, however without reaching statistical significance. Catestatin concentrationdid not differ between tumour types. Conclusions: Elevated plasma concentration of the CgA epitope vasostatin showed potential as a biomarker for asubset of catecholamine-secreting tumours.
- Open Access
- 19 September 2026
- Published by Springer Nature in Acta Veterinaria Scandinavica
- Vol. 68 (1) , 41
Ligation of the canine mesovarium with a resorbable self-locking device: a multicentre study
Background: Haemorrhage from the ovarian pedicle is a known complication at removal of ovaries in dogs. A resorbable self-locking device designed for surgical ligation was previously developed, aimed to keep the advantage of a self-locking loop at ligation and avoid the chronic tissue reactions of non-resorbable materials. The primary aim of the study was to continue to evaluate the feasibility and clinical performance of the device for ligation of the canine mesovarium in a prospective multicentre controlled study. Secondary aims were to compare perioperative complications, ligation time, and duration of surgery between the device and a traditional double ligature technique. Results: In total, 72 intact female dogs destined for elective ovariohysterectomy were included in the study. The device was tested in 36 dogs across four centres, and 36 dogs were used as controls. Across all centres, body weights of device and control groups were 14.5 ± 1.0 kg and 14.9 ± 1.3 kg, respectively. The device group was 2.5 ± 0.3 years old and controls were 3.6 ± 0.4 years old. Estimating mean times from the linear mixed models gave ligation times for device and control groups of 4.4 ± 1.3 minutes and 4.5 ± 0.4 minutes, respectively. Duration of surgery for device and control groups were 21.3 ± 4.0 minutes and 16.7 ± 0.7 minutes, respectively. Both surgery and ligation times showed a significant centre-specific treatment effect. Two cases of intraoperative bleeding from the ovarian pedicles were observed in the control group. No postoperative complications were observed and all dogs recovered uneventfully. Conclusions: The device could be used for compression of tissue of the ovarian pedicle, provided haemostasis and adequate support of tissue throughout the healing period. Time for double ligation and duration of surgery did not differ between groups. Centres with previous experience of using the device recorded shorter ligation times and duration of surgery, which suggests a learning curve.
- 19 September 2026
- Published by Springer Nature in Acta Veterinaria Scandinavica
- Vol. 68 (1) , 41
Open AccessLigation of the canine mesovarium with a resorbable self-locking device: a multicentre study
Background: Haemorrhage from the ovarian pedicle is a known complication at removal of ovaries in dogs. A resorbable self-locking device designed for surgical ligation was previously developed, aimed to keep the advantage of a self-locking loop at ligation and avoid the chronic tissue reactions of non-resorbable materials. The primary aim of the study was to continue to evaluate the feasibility and clinical performance of the device for ligation of the canine mesovarium in a prospective multicentre controlled study. Secondary aims were to compare perioperative complications, ligation time, and duration of surgery between the device and a traditional double ligature technique. Results: In total, 72 intact female dogs destined for elective ovariohysterectomy were included in the study. The device was tested in 36 dogs across four centres, and 36 dogs were used as controls. Across all centres, body weights of device and control groups were 14.5 ± 1.0 kg and 14.9 ± 1.3 kg, respectively. The device group was 2.5 ± 0.3 years old and controls were 3.6 ± 0.4 years old. Estimating mean times from the linear mixed models gave ligation times for device and control groups of 4.4 ± 1.3 minutes and 4.5 ± 0.4 minutes, respectively. Duration of surgery for device and control groups were 21.3 ± 4.0 minutes and 16.7 ± 0.7 minutes, respectively. Both surgery and ligation times showed a significant centre-specific treatment effect. Two cases of intraoperative bleeding from the ovarian pedicles were observed in the control group. No postoperative complications were observed and all dogs recovered uneventfully. Conclusions: The device could be used for compression of tissue of the ovarian pedicle, provided haemostasis and adequate support of tissue throughout the healing period. Time for double ligation and duration of surgery did not differ between groups. Centres with previous experience of using the device recorded shorter ligation times and duration of surgery, which suggests a learning curve.
- Open Access
- 17 August 2026
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
Preclinical Cyclic Testing of Adjunctive Fixation of the Humeral Epicondyle in a Lateral Condylar Fracture Model: Ex Vivo Comparison of a Locking Plate versus a Light-curable Composite
To compare the mechanical performance under cyclic loading of a biocompatible light-curable composite formed from two traizine-trione resin monomers and hydroxyapatite construct (AdhFix) against a standard locking plate used as adjunctive epicondylar stabilization in a simulated lateral condylar humeral fracture model. Cadaveric biomechanical assessment. Paired canine cadaver humeri were used to simulate lateral condylar humeral fractures. All constructs were stabilized with a transcondylar 4.5 mm cortical screw placed in lag fashion. Adjunctive fixation was then applied in a within-cadaver comparison: One humerus received a light-curable composite construct incorporating 2.7 mm cortical screws, while the contralateral humerus received a 2.7 mm locking plate. Specimens were subjected to 95,000 cycles of axial compressive loading between 20 and 130 N. Groups were compared for displacement and construct dynamic stiffness (p < 0.05). Terminal monotonic testing was then performed until failure. There was no mechanical failure in either group during cyclic testing. There were no statistically significant differences between groups in construct dynamic stiffness, displacement, or yield point in terminal monotonic testing. Cyclic testing support the use of AdhFix as adjunctive fixation in humeral condylar fractures.
- 17 August 2026
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
Open AccessPreclinical Cyclic Testing of Adjunctive Fixation of the Humeral Epicondyle in a Lateral Condylar Fracture Model: Ex Vivo Comparison of a Locking Plate versus a Light-curable Composite
To compare the mechanical performance under cyclic loading of a biocompatible light-curable composite formed from two traizine-trione resin monomers and hydroxyapatite construct (AdhFix) against a standard locking plate used as adjunctive epicondylar stabilization in a simulated lateral condylar humeral fracture model. Cadaveric biomechanical assessment. Paired canine cadaver humeri were used to simulate lateral condylar humeral fractures. All constructs were stabilized with a transcondylar 4.5 mm cortical screw placed in lag fashion. Adjunctive fixation was then applied in a within-cadaver comparison: One humerus received a light-curable composite construct incorporating 2.7 mm cortical screws, while the contralateral humerus received a 2.7 mm locking plate. Specimens were subjected to 95,000 cycles of axial compressive loading between 20 and 130 N. Groups were compared for displacement and construct dynamic stiffness (p < 0.05). Terminal monotonic testing was then performed until failure. There was no mechanical failure in either group during cyclic testing. There were no statistically significant differences between groups in construct dynamic stiffness, displacement, or yield point in terminal monotonic testing. Cyclic testing support the use of AdhFix as adjunctive fixation in humeral condylar fractures.
- Open Access
- 13 August 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
A hydroxyapatite-based synthetic bone graft reduces intervertebral motion at 12 months, as measured by CT-RSA, in a porcine model of ACDF
- 13 August 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
Open AccessA hydroxyapatite-based synthetic bone graft reduces intervertebral motion at 12 months, as measured by CT-RSA, in a porcine model of ACDF
- Open Access
- 18 November 2025
- Published by Wiley in Journal of Small Animal Practice
- Vol. 67 (3) , 271-277
Effect of novel metabotropic glutamate receptor 5 antagonist on gastroesophageal reflux in dogs during anaesthesia
Objectives: Gastroesophageal reflux during anaesthesia is a common event occurring in dogs with the potential to cause oesophageal injury and aspiration pneumonia. The objective of the current study was to evaluate the effect of the novel metabotropic glutamate receptor 5 antagonist TT001 on gastroesophageal reflux during anaesthesia in dogs using two different protocols. Materials and Methods: One hundred and nineteen client‐owned dogs were included and randomly assigned to receive test‐drug containing either active TT001 ( n = 58) or placebo vehicle ( n = 61). In protocol 1 ( n = 77), test‐drug was administered shortly before induction and in protocol 2 ( n = 42) test‐drug was administered 15 minutes before standardised pre‐anaesthetic drugs. Gastroesophageal reflux (pH <4) was measured and recorded using oesophageal pH‐metry throughout the duration of the anaesthesia. Results: Gastroesophageal reflux was registered in 45.4% of dogs, in protocol 1: 44.2%, and in protocol 2: 47.6%. No overall statistically significant difference between the dogs receiving active TT001 (group A, 48.3%) and placebo (group B, 42.6%) was observed, regardless of the protocol tested (protocol 1: group A: 47.4%, group B: 41.0%; protocol 2: group A: 50.0%, group B: 45.5%). Clinical Significance: Administration of metabotropic glutamate receptor 5 antagonist TT001 as a single intravenous bolus injection before or after pre‐anaesthetic drugs has limited effect on the incidence of gastroesophageal reflux in anaesthetised dogs.
- 18 November 2025
- Published by Wiley in Journal of Small Animal Practice
- Vol. 67 (3) , 271-277
Open AccessEffect of novel metabotropic glutamate receptor 5 antagonist on gastroesophageal reflux in dogs during anaesthesia
Objectives: Gastroesophageal reflux during anaesthesia is a common event occurring in dogs with the potential to cause oesophageal injury and aspiration pneumonia. The objective of the current study was to evaluate the effect of the novel metabotropic glutamate receptor 5 antagonist TT001 on gastroesophageal reflux during anaesthesia in dogs using two different protocols. Materials and Methods: One hundred and nineteen client‐owned dogs were included and randomly assigned to receive test‐drug containing either active TT001 ( n = 58) or placebo vehicle ( n = 61). In protocol 1 ( n = 77), test‐drug was administered shortly before induction and in protocol 2 ( n = 42) test‐drug was administered 15 minutes before standardised pre‐anaesthetic drugs. Gastroesophageal reflux (pH <4) was measured and recorded using oesophageal pH‐metry throughout the duration of the anaesthesia. Results: Gastroesophageal reflux was registered in 45.4% of dogs, in protocol 1: 44.2%, and in protocol 2: 47.6%. No overall statistically significant difference between the dogs receiving active TT001 (group A, 48.3%) and placebo (group B, 42.6%) was observed, regardless of the protocol tested (protocol 1: group A: 47.4%, group B: 41.0%; protocol 2: group A: 50.0%, group B: 45.5%). Clinical Significance: Administration of metabotropic glutamate receptor 5 antagonist TT001 as a single intravenous bolus injection before or after pre‐anaesthetic drugs has limited effect on the incidence of gastroesophageal reflux in anaesthetised dogs.
- Open Access
- 2 June 2025
- Published by Springer Nature in Acta Veterinaria Scandinavica
- Vol. 67 (1) , 1-5
The development of a novel virtual reality simulation module for canine laparoscopic ovariectomy
Canine ovariectomy is a commonly performed procedure in veterinary practice and can be done via an open celiotomy or a laparoscopic approach. Laparoscopy requires different psychomotor skills from those involved in open surgery. Many of these basic skills can initially be acquired through simulation-based training. Surgical simulation training benefits both the surgeon and the patient by offering the acquisition of new skills in a less stressful environment while lowering the risk for the patient. Virtual reality (VR) simulation training is well established in human medicine, but no VR modules have previously been available for veterinary procedure training for laparoscopy. This project aimed to develop a VR simulator module for canine laparoscopic ovariectomy on the simulator LapSim® (Surgical Science, Gothenburg, Sweden). The simulator module could offer veterinary surgeons the opportunity to gain the basic technical skills required for canine laparoscopic ovariectomy. Surgeons with experience in laparoscopic ovariectomy acted as content experts, and the development was a stepwise iterative process. The three-port technique was chosen; it included locating and lifting the uterine horn and sealing and transecting tissue to free the ovaries. The organs and tissues the surgeon interacted with during the simulation were the spleen, intestines, pancreas, ovaries, uterine horns, suspensory ligaments, mesometrium and mesovarium. The module included simulating haemorrhage from the spleen, ovarian and uterine vessels. Suggestions for the continued development of the simulation were identified. Examples were an increased haptic feel in some instances of tissue manipulation and the possibility of introducing a variation in the length of the ovarian pedicle. The last step of the simulated procedure included visual guidance for verification of haemostasis. Even though guidance is not part of a real-life operation, identifying anatomical landmarks was considered valuable from an educational perspective. A validity investigation study has been initiated to evaluate the module as an assessment tool.
- 2 June 2025
- Published by Springer Nature in Acta Veterinaria Scandinavica
- Vol. 67 (1) , 1-5
Open AccessThe development of a novel virtual reality simulation module for canine laparoscopic ovariectomy
Canine ovariectomy is a commonly performed procedure in veterinary practice and can be done via an open celiotomy or a laparoscopic approach. Laparoscopy requires different psychomotor skills from those involved in open surgery. Many of these basic skills can initially be acquired through simulation-based training. Surgical simulation training benefits both the surgeon and the patient by offering the acquisition of new skills in a less stressful environment while lowering the risk for the patient. Virtual reality (VR) simulation training is well established in human medicine, but no VR modules have previously been available for veterinary procedure training for laparoscopy. This project aimed to develop a VR simulator module for canine laparoscopic ovariectomy on the simulator LapSim® (Surgical Science, Gothenburg, Sweden). The simulator module could offer veterinary surgeons the opportunity to gain the basic technical skills required for canine laparoscopic ovariectomy. Surgeons with experience in laparoscopic ovariectomy acted as content experts, and the development was a stepwise iterative process. The three-port technique was chosen; it included locating and lifting the uterine horn and sealing and transecting tissue to free the ovaries. The organs and tissues the surgeon interacted with during the simulation were the spleen, intestines, pancreas, ovaries, uterine horns, suspensory ligaments, mesometrium and mesovarium. The module included simulating haemorrhage from the spleen, ovarian and uterine vessels. Suggestions for the continued development of the simulation were identified. Examples were an increased haptic feel in some instances of tissue manipulation and the possibility of introducing a variation in the length of the ovarian pedicle. The last step of the simulated procedure included visual guidance for verification of haemostasis. Even though guidance is not part of a real-life operation, identifying anatomical landmarks was considered valuable from an educational perspective. A validity investigation study has been initiated to evaluate the module as an assessment tool.
- Open Access
- 12 January 2024
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (17) , 1179-1186
Novel Calcium Phosphate Promotes Interbody Bony Fusion in a Porcine Anterior Cervical Discectomy and Fusion Model
Study Design.: Experimental porcine anterior cervical discectomy and fusion (ACDF) model: a proof-of-concept study. Objective.: The effect of monetite synthetic bone graft (SBG) containing calcium pyrophosphate and β-tricalcium phosphate on cervical spinal fusion in a noninstrumented two-level large animal model. Summary of Background Data.: ACDF is the gold standard surgical technique for the treatment of degenerative cervical spinal diseases. However, pseudarthrosis associated with increased patient morbidity occurs in ∼2.6% of the surgeries. SBG may enhance bony fusion and subsequently decrease the risk of pseudarthrosis. Recent studies on monetite-based SBGs for use in large cranial defects in humans have shown promising bone healing results, necessitating further investigation of their use in cervical spinal fusion. Materials and Methods.: Four adult female Danish Göttingen minipigs received partial cervical anterior discectomy and intervertebral defects at an upper and lower level. One defect was filled with SBG, and the other was left empty. Bony fusion was evaluated using computed tomography (CT) at three-month intervals for 12 months. Fifteen months postsurgery, the animals were euthanized for further ex vivo qualitative histopathologic and micro-CT evaluations. Fusion rates were compared using the Fisher exact test at each time point. Results.: Increased interbody bony fusion rates were observed at SBG levels (4/4) compared with control levels (0/4) evaluated by CT at 6 and 9 months postsurgery (P=0.029). Fusion was observed at all SBG levels 12 months postsurgery and at only one control level. Histopathologic evaluation confirmed high-quality interbody bony fusion at all SBG levels and fusion by spondylosis at one control level. Conclusion.: This proof-of-concept study provides preliminary evidence of a novel, calcium pyrophosphate-containing, and β-tricalcium phosphate-containing monetite SBG that promotes bony fusion compared with a negative control in a clinically relevant porcine model of ACDF.
- 12 January 2024
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (17) , 1179-1186
Open AccessNovel Calcium Phosphate Promotes Interbody Bony Fusion in a Porcine Anterior Cervical Discectomy and Fusion Model
Study Design.: Experimental porcine anterior cervical discectomy and fusion (ACDF) model: a proof-of-concept study. Objective.: The effect of monetite synthetic bone graft (SBG) containing calcium pyrophosphate and β-tricalcium phosphate on cervical spinal fusion in a noninstrumented two-level large animal model. Summary of Background Data.: ACDF is the gold standard surgical technique for the treatment of degenerative cervical spinal diseases. However, pseudarthrosis associated with increased patient morbidity occurs in ∼2.6% of the surgeries. SBG may enhance bony fusion and subsequently decrease the risk of pseudarthrosis. Recent studies on monetite-based SBGs for use in large cranial defects in humans have shown promising bone healing results, necessitating further investigation of their use in cervical spinal fusion. Materials and Methods.: Four adult female Danish Göttingen minipigs received partial cervical anterior discectomy and intervertebral defects at an upper and lower level. One defect was filled with SBG, and the other was left empty. Bony fusion was evaluated using computed tomography (CT) at three-month intervals for 12 months. Fifteen months postsurgery, the animals were euthanized for further ex vivo qualitative histopathologic and micro-CT evaluations. Fusion rates were compared using the Fisher exact test at each time point. Results.: Increased interbody bony fusion rates were observed at SBG levels (4/4) compared with control levels (0/4) evaluated by CT at 6 and 9 months postsurgery (P=0.029). Fusion was observed at all SBG levels 12 months postsurgery and at only one control level. Histopathologic evaluation confirmed high-quality interbody bony fusion at all SBG levels and fusion by spondylosis at one control level. Conclusion.: This proof-of-concept study provides preliminary evidence of a novel, calcium pyrophosphate-containing, and β-tricalcium phosphate-containing monetite SBG that promotes bony fusion compared with a negative control in a clinically relevant porcine model of ACDF.
- Open Access
- 6 November 2023
- Published by Wiley in Veterinary Surgery
- Vol. 53 (2) , 311-319
Adjunctive fixation of the humeral epicondyle in a lateral condylar fracture model: Ex vivo comparison of pins and plates with a novel composite (AdhFix)
Objective: To compare the biomechanical properties of using a novel composite construct (AdhFix) to an interfragmentary Kirschner wire or a reconstruction plate as adjunctive epicondylar stabilization in simulated lateral unicondylar humeral fractures.Study design: Cadaveric biomechanical assessment.Sample population: Paired humeri harvested from skeletally mature dogs (14-41 kg), nine cadavers per group.Methods: Simulated lateral unicondylar humeral fractures were stabilized with a transcondylar 4.5 mm cortical screw placed in lag fashion. Adjunct fixations consisting of a novel composite incorporating 2.7 mm cortical screws on one side, and either a 2.7 mm reconstruction plate or a 1.6 mm Kirschner wire on the contralateral side, were tested within paired humeri. Repaired humeri were axially loaded to failure and construct stiffness, yield load, and ultimate load were obtained from the load-deformation curves.Results: In pairwise comparison, yield load was significantly higher for AdhFix group compared to the pin group, p = .016. No statistical significance was seen in the comparison between AdhFix group and the plate group, p = .25.Conclusion: Adhfix was mechanically superior to K-wires, and comparable to plate fixation, for adjunctive fixation in a lateral humeral condylar model. Our results support further investigation of the novel composite for adjunct fracture fixation in lateral humeral condylar fractures.Clinical significance: The novel composite tested may be a viable alternative for adjunct fixation of humeral condylar fractures, a technique that circumvents plate contouring.
- 6 November 2023
- Published by Wiley in Veterinary Surgery
- Vol. 53 (2) , 311-319
Open AccessAdjunctive fixation of the humeral epicondyle in a lateral condylar fracture model: Ex vivo comparison of pins and plates with a novel composite (AdhFix)
Objective: To compare the biomechanical properties of using a novel composite construct (AdhFix) to an interfragmentary Kirschner wire or a reconstruction plate as adjunctive epicondylar stabilization in simulated lateral unicondylar humeral fractures.Study design: Cadaveric biomechanical assessment.Sample population: Paired humeri harvested from skeletally mature dogs (14-41 kg), nine cadavers per group.Methods: Simulated lateral unicondylar humeral fractures were stabilized with a transcondylar 4.5 mm cortical screw placed in lag fashion. Adjunct fixations consisting of a novel composite incorporating 2.7 mm cortical screws on one side, and either a 2.7 mm reconstruction plate or a 1.6 mm Kirschner wire on the contralateral side, were tested within paired humeri. Repaired humeri were axially loaded to failure and construct stiffness, yield load, and ultimate load were obtained from the load-deformation curves.Results: In pairwise comparison, yield load was significantly higher for AdhFix group compared to the pin group, p = .016. No statistical significance was seen in the comparison between AdhFix group and the plate group, p = .25.Conclusion: Adhfix was mechanically superior to K-wires, and comparable to plate fixation, for adjunctive fixation in a lateral humeral condylar model. Our results support further investigation of the novel composite for adjunct fracture fixation in lateral humeral condylar fractures.Clinical significance: The novel composite tested may be a viable alternative for adjunct fixation of humeral condylar fractures, a technique that circumvents plate contouring.
- 19 September 2023
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 50 (4) , 475-481
Confidence among Veterinary Students to Perform Canine Orchiectomy: The Impact of Live Animal Surgical Clinical Training
Canine orchiectomy (COE) is one of the most commonly performed procedures in small animal veterinary surgery. The aim of this study was to assess veterinary students’ confidence in performing this surgery in relation to their previous surgical experience of the procedure. The hypothesis was that confidence to perform canine orchiectomies among recent veterinary graduates increased when having participated in the procedure as part of practical surgical training. A cross-sectional survey was conducted and included 65 fifth-year veterinary graduate students at the Swedish University of Agriculture in Uppsala, Sweden. The survey investigated how differences in experience of COE affected students’ confidence to perform the procedure. Of the responding students, 24.6% had performed the procedure, 47.7% had observed the procedure live, and 27.7% had not seen nor performed the procedure. They were asked how confident they were to perform the procedure both with and without assistance. Data were compared using a non-parametric test (Mann–Whitney U test). The results showed a statistically significant increase in confidence to perform COEs in the group that had previously performed or observed COE compared with the group that had neither performed nor observed the procedure. In conclusion, veterinary students’ participation in COEs significantly contributed to their clinical confidence to perform the procedure.
- 19 September 2023
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 50 (4) , 475-481
Confidence among Veterinary Students to Perform Canine Orchiectomy: The Impact of Live Animal Surgical Clinical Training
Canine orchiectomy (COE) is one of the most commonly performed procedures in small animal veterinary surgery. The aim of this study was to assess veterinary students’ confidence in performing this surgery in relation to their previous surgical experience of the procedure. The hypothesis was that confidence to perform canine orchiectomies among recent veterinary graduates increased when having participated in the procedure as part of practical surgical training. A cross-sectional survey was conducted and included 65 fifth-year veterinary graduate students at the Swedish University of Agriculture in Uppsala, Sweden. The survey investigated how differences in experience of COE affected students’ confidence to perform the procedure. Of the responding students, 24.6% had performed the procedure, 47.7% had observed the procedure live, and 27.7% had not seen nor performed the procedure. They were asked how confident they were to perform the procedure both with and without assistance. Data were compared using a non-parametric test (Mann–Whitney U test). The results showed a statistically significant increase in confidence to perform COEs in the group that had previously performed or observed COE compared with the group that had neither performed nor observed the procedure. In conclusion, veterinary students’ participation in COEs significantly contributed to their clinical confidence to perform the procedure.