Yaqub Mahnashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yaqub Mahnashi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Noman Tasadduq
Electrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
4 shared publicationsHussain Alzaher
Electrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
3 shared publications- Abdulaziz Al-Khulaifi
Electrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
2 shared publications - Abdullah Abdulhameed
Center for Communication Systems and Sensing, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
2 shared publications Fang Z. Peng
Dept of Electrical and Computer Engineering, Michigan State University, East Lansing, MI
2 shared publications- Hussein Attia
King Fahd University of Petroleum & Minerals (KFUPM)
2 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Elsevier in Next Materials
- Vol. 13
Growth and characterization of ZnO nanostructures on 3D-printed thermoplastic polymers for biosensing and biomedical applications
- 23 September 2026
- Published by Elsevier in Next Materials
- Vol. 13
Open AccessGrowth and characterization of ZnO nanostructures on 3D-printed thermoplastic polymers for biosensing and biomedical applications
- 27 July 2026
- Published by Wiley in Electroanalysis
- Vol. 38 (8) , e70194
Frequency‐Dependent Electrical Response of Polystyrene Microparticle Suspensions on Coplanar Electrodes
The dielectric properties of microparticles, such as bacterial cells, are influenced by several internal factors, including the microparticle’s internal structure, size, and surface modification. These factors create a dielectric fingerprint for the microparticle, which can be exploited for detection using capacitance‐based mechanisms. However, measuring small changes in capacitance due to the presence of specific microparticles in a microfluidic system remains challenging, as many external factors and physical phenomena can influence the measurement. The primary goal of this study is to investigate the capacitance variation of microparticle suspensions placed on top of coplanar electrodes across a wide range of frequencies. Polystyrene particles of sizes 0.29, 0.52, 1.35, 2.26, and 4.79 µm are suspended in distilled water at concentrations from 2.5 to 0.156 wt.%. The study concludes that capacitance spectra are mainly governed by electrode polarization, ionic conduction, and particle/water interfacial polarization at low frequencies and by the intrinsic bulk dielectric characteristic at higher and microwave frequencies. LCR measurements gave a strongly dispersive response, with the apparent capacitance decreasing from about 10–100 nF at 10 Hz to ~3–10 pF at 10 MHz. Increasing polystyrene concentration from 0.156 to 2.5 wt.% and decreasing particle size from 4.79 to 0.29 µm both increased the low‐ and mid‐frequency loss response, yielding higher capacitance, lower resistance, phase angles closer to 0°, and dissipation‐factor peaks of about 6–17 in the 10 4 –10 6 Hz range. The findings of this study help in understanding the capacitance measurement of samples containing suspended microparticles, including biosamples.
- 27 July 2026
- Published by Wiley in Electroanalysis
- Vol. 38 (8) , e70194
Frequency‐Dependent Electrical Response of Polystyrene Microparticle Suspensions on Coplanar Electrodes
The dielectric properties of microparticles, such as bacterial cells, are influenced by several internal factors, including the microparticle’s internal structure, size, and surface modification. These factors create a dielectric fingerprint for the microparticle, which can be exploited for detection using capacitance‐based mechanisms. However, measuring small changes in capacitance due to the presence of specific microparticles in a microfluidic system remains challenging, as many external factors and physical phenomena can influence the measurement. The primary goal of this study is to investigate the capacitance variation of microparticle suspensions placed on top of coplanar electrodes across a wide range of frequencies. Polystyrene particles of sizes 0.29, 0.52, 1.35, 2.26, and 4.79 µm are suspended in distilled water at concentrations from 2.5 to 0.156 wt.%. The study concludes that capacitance spectra are mainly governed by electrode polarization, ionic conduction, and particle/water interfacial polarization at low frequencies and by the intrinsic bulk dielectric characteristic at higher and microwave frequencies. LCR measurements gave a strongly dispersive response, with the apparent capacitance decreasing from about 10–100 nF at 10 Hz to ~3–10 pF at 10 MHz. Increasing polystyrene concentration from 0.156 to 2.5 wt.% and decreasing particle size from 4.79 to 0.29 µm both increased the low‐ and mid‐frequency loss response, yielding higher capacitance, lower resistance, phase angles closer to 0°, and dissipation‐factor peaks of about 6–17 in the 10 4 –10 6 Hz range. The findings of this study help in understanding the capacitance measurement of samples containing suspended microparticles, including biosamples.
- Open Access
A Simulation Study of a Novel Electrokinetic-Based Focusing Technique to Enhance the Real-Time Detection of Microplastics in Water Flow
The contamination of aquatic environments, including treated and drinking water, by microplastics poses a significant threat to ecosystems and human health. Current detection methods often rely on slow laboratory-based tests and offline analysis, which do not support real-time monitoring. This paper presents a novel focusing and concentrating device designed to enhance the real-time detection of microplastics in flowing water. The device utilizes an electrokinetic manipulation mechanism to focus microplastics toward the center of the water flow inside a pipe or fluid channel. A set of 3D rectangular electrodes, with dimensions of 5 mm × 2.5 mm × 1 mm, are arranged circumferentially and longitudinally along the inner perimeter of the fluid channel to generate an intense, non-uniform electric field. Simulation results indicate that microplastics near the channel wall experience a repulsive force on the order of to N toward the channel center. The applied signal amplitude and the physical properties of the microplastics strongly influence this repulsive force. The trajectories and output concentration of microplastics are investigated under varied conditions. A Voltage of approximately 25 V and a flow rate of 0.05 m/s are found to be ideal for concentrating microplastics into a narrow particle stream, enabling more efficient downstream detection and analysis. Pre-concentrating microplastics in fluid channels prior to sensing is expected to increase sensor sensitivity and improve selectivity.Open AccessA Simulation Study of a Novel Electrokinetic-Based Focusing Technique to Enhance the Real-Time Detection of Microplastics in Water Flow
The contamination of aquatic environments, including treated and drinking water, by microplastics poses a significant threat to ecosystems and human health. Current detection methods often rely on slow laboratory-based tests and offline analysis, which do not support real-time monitoring. This paper presents a novel focusing and concentrating device designed to enhance the real-time detection of microplastics in flowing water. The device utilizes an electrokinetic manipulation mechanism to focus microplastics toward the center of the water flow inside a pipe or fluid channel. A set of 3D rectangular electrodes, with dimensions of 5 mm × 2.5 mm × 1 mm, are arranged circumferentially and longitudinally along the inner perimeter of the fluid channel to generate an intense, non-uniform electric field. Simulation results indicate that microplastics near the channel wall experience a repulsive force on the order of to N toward the channel center. The applied signal amplitude and the physical properties of the microplastics strongly influence this repulsive force. The trajectories and output concentration of microplastics are investigated under varied conditions. A Voltage of approximately 25 V and a flow rate of 0.05 m/s are found to be ideal for concentrating microplastics into a narrow particle stream, enabling more efficient downstream detection and analysis. Pre-concentrating microplastics in fluid channels prior to sensing is expected to increase sensor sensitivity and improve selectivity. - Open Access
- 3 September 2024
- Published by Elsevier in Results in Optics
- Vol. 16
Near-infrared spectroscopy for glucose detection in aqueous solution
- 3 September 2024
- Published by Elsevier in Results in Optics
- Vol. 16
Open AccessNear-infrared spectroscopy for glucose detection in aqueous solution
- 13 August 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (12) , 17023-17029
A New Highly Linear Current-to-Time Converter for Direct Sensing Applications
- 13 August 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (12) , 17023-17029
A New Highly Linear Current-to-Time Converter for Direct Sensing Applications
- 21 September 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (11) , 15553-15560
A New Wide Power Dynamic Range CMOS RF-to-DC Converter Using Body-Control Scheme
- 21 September 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (11) , 15553-15560
A New Wide Power Dynamic Range CMOS RF-to-DC Converter Using Body-Control Scheme
- 12 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2856-2864
Design and Experimental Validation of a Noninvasive Glucose Monitoring System Using RF Antenna-Based Biosensor
This paper presents an end-to-end microwave-based system to detect the glucose level in aqueous solutions through a non-invasive scheme. A microwave signal is generated and transmitted through the sample under test (i.e., glucose-water solution). The received signal is then conditioned using a low-noise amplifier (LNA), a band-pass filter (BPF), and an RF detector. The change in the DC output voltage on the receiver side is used as a new way to detect the glucose level. The proposed glucose sensor is implemented using two RF microstrip patch antennas that resonate at 5.7 GHz and are fabricated using an FR-4 substrate. The design specifications of the sensing antennas are thoroughly studied and presented. The system is verified experimentally using glucose-water testing samples. The experimental results confirm the correlation between the glucose concentration and the DC output voltage for a concentration range of 0-5000 mg/dL. The effect of the transmitted power level on the system performance is also investigated. Finally, the proposed system is compared with the state-of-the-art systems reported in the literature.
- 12 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2856-2864
Design and Experimental Validation of a Noninvasive Glucose Monitoring System Using RF Antenna-Based Biosensor
This paper presents an end-to-end microwave-based system to detect the glucose level in aqueous solutions through a non-invasive scheme. A microwave signal is generated and transmitted through the sample under test (i.e., glucose-water solution). The received signal is then conditioned using a low-noise amplifier (LNA), a band-pass filter (BPF), and an RF detector. The change in the DC output voltage on the receiver side is used as a new way to detect the glucose level. The proposed glucose sensor is implemented using two RF microstrip patch antennas that resonate at 5.7 GHz and are fabricated using an FR-4 substrate. The design specifications of the sensing antennas are thoroughly studied and presented. The system is verified experimentally using glucose-water testing samples. The experimental results confirm the correlation between the glucose concentration and the DC output voltage for a concentration range of 0-5000 mg/dL. The effect of the transmitted power level on the system performance is also investigated. Finally, the proposed system is compared with the state-of-the-art systems reported in the literature.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (4) , 1465-1469
A New Approach to Improve the Voltage Conversion Ratio in Topological Switched-Capacitor DC–DC Converters Using Negator Stage
This paper provides a simple yet novel structure to achieve voltage conversion ratio (VCR) that exceeds the theoretical attainable VCR of topological switched-capacitor DC-DC converters (SCC). Typically, the SCC terminals are connected to the input voltage, the output voltage, or the ground reference. The proposed structure in this paper utilizes the ground-connected terminals and instead connecting them to negative input voltage provided by a negator stage. Here, two types of SCC are used as case studies: Series-parallel (SPSC) and Fibonacci (FSC). The model for the proposed structure is constructed and verified experimentally using 3-stage SPSC and FSC. The experimental results are in good agreement with the proposed model with an error of less than 5% in all cases. The VCR obtained from the proposed structure exceeds the theoretical limits of conventional topological structures.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 70 (4) , 1465-1469
A New Approach to Improve the Voltage Conversion Ratio in Topological Switched-Capacitor DC–DC Converters Using Negator Stage
This paper provides a simple yet novel structure to achieve voltage conversion ratio (VCR) that exceeds the theoretical attainable VCR of topological switched-capacitor DC-DC converters (SCC). Typically, the SCC terminals are connected to the input voltage, the output voltage, or the ground reference. The proposed structure in this paper utilizes the ground-connected terminals and instead connecting them to negative input voltage provided by a negator stage. Here, two types of SCC are used as case studies: Series-parallel (SPSC) and Fibonacci (FSC). The model for the proposed structure is constructed and verified experimentally using 3-stage SPSC and FSC. The experimental results are in good agreement with the proposed model with an error of less than 5% in all cases. The VCR obtained from the proposed structure exceeds the theoretical limits of conventional topological structures.
- Open Access
- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A New Approach to Improve the Voltage Conversion Ratio in Topological Switched-capacitor DC-DC Converters Using Negator Stage
This paper provides a simple yet novel structure to achieve voltage conversion ratio (VCR) that exceeds the theoretical attainable VCR of topological switched-capacitor DC-DC converters (SCC). Typically, the SCC terminals are connected to the input voltage, the output voltage, or the ground reference. The proposed structure in this paper utilizes the ground-connected terminals and instead connecting them to negative input voltage provided by a negator stage. Here, two types of SCC are used as case studies: Series-parallel (SPSC) and Fibonacci (FSC). The model for the proposed structure is constructed and verified experimentally using 3-stage SPSC and FSC. The experimental results are in good agreement with the proposed model with an error of less than 5% in all cases. The VCR obtained from the proposed structure exceeds the theoretical limits of conventional topological structures.
- 5 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA New Approach to Improve the Voltage Conversion Ratio in Topological Switched-capacitor DC-DC Converters Using Negator Stage
This paper provides a simple yet novel structure to achieve voltage conversion ratio (VCR) that exceeds the theoretical attainable VCR of topological switched-capacitor DC-DC converters (SCC). Typically, the SCC terminals are connected to the input voltage, the output voltage, or the ground reference. The proposed structure in this paper utilizes the ground-connected terminals and instead connecting them to negative input voltage provided by a negator stage. Here, two types of SCC are used as case studies: Series-parallel (SPSC) and Fibonacci (FSC). The model for the proposed structure is constructed and verified experimentally using 3-stage SPSC and FSC. The experimental results are in good agreement with the proposed model with an error of less than 5% in all cases. The VCR obtained from the proposed structure exceeds the theoretical limits of conventional topological structures.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Systematic approach to optimal SC converter synthesis for multi voltage-gain-ratio applications
Synthesizing the switched-capacitor (SC) converter to perform certain voltage conversions is considered a challenge in SC converter design. This paper presents a systematic approach to synthesize an optimal SC converter for multiple voltage-gain-ratio (VCR) applications. The optimization methodology is based on the minimum number of components, i.e. capacitors and switches. This approach exploits the canonical model presented in [8] which ensures that the converter is using the minimum number of capacitors based on the Fibonacci fundamental limit. Moreover, using the method presented in this paper, the controller circuit of the designed SC converter is simplified. Case studies are presented to show how different SC converters can be synthesized.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Systematic approach to optimal SC converter synthesis for multi voltage-gain-ratio applications
Synthesizing the switched-capacitor (SC) converter to perform certain voltage conversions is considered a challenge in SC converter design. This paper presents a systematic approach to synthesize an optimal SC converter for multiple voltage-gain-ratio (VCR) applications. The optimization methodology is based on the minimum number of components, i.e. capacitors and switches. This approach exploits the canonical model presented in [8] which ensures that the converter is using the minimum number of capacitors based on the Fibonacci fundamental limit. Moreover, using the method presented in this paper, the controller circuit of the designed SC converter is simplified. Case studies are presented to show how different SC converters can be synthesized.