Kristina Hamachi LaCommare
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kristina Hamachi LaCommare has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Joseph H. Eto
Energy Technologies Area, Lawrence Berkeley National Laboratory, United States
2 shared publications Laurel N. Dunn
Department of Civil and Environmental Engineering, University of California Berkeley, United States
2 shared publicationsMichael D. Sohn
Energy Technologies Area, Lawrence Berkeley National Laboratory, United States
2 shared publicationsDavid Till
North American Electric Reliability Corporation 3353 Peachtree Road NE Suite 600 Atlanta GA USA
1 shared publicationHeidemarie C. Caswell
PacifiCorp 825 NE Multnomah Suite 1500 Portland OR USA
1 shared publicationJoseph H. Eto
1 shared publication
Latest Publications
- 1 June 2019
- Published by Elsevier in Energy Policy
- Vol. 129, 206-214
Exploratory analysis of high-resolution power interruption data reveals spatial and temporal heterogeneity in electric grid reliability
- 1 June 2019
- Published by Elsevier in Energy Policy
- Vol. 129, 206-214
Exploratory analysis of high-resolution power interruption data reveals spatial and temporal heterogeneity in electric grid reliability
- Open Access
- 28 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (5) , 717-723
Distribution system versus bulk power system: identifying the source of electric service interruptions in the US
This study reports on the results from efforts by the Institute of Electric and Electronics Engineers (IEEE) Distribution Reliability Working Group (DRWG) and the U.S. Energy Information Administration (EIA) to improve the usefulness of reliability metrics by developing and then applying consistent, yet distinct measures of the continuity of supply based on the portion of the electric power system from which power interruptions originate: the lower voltage distribution system versus the high‐voltage bulk power system. The modified metrics better support reliability planning in the US because they separately measure the effectiveness of actions to improve reliability made by the two distinct groups of firms (and their regulators or oversight bodies) that are responsible for planning and operating each portion of the US electric power system. The authors then present for the first time quantitative information on the reliability of each portion of the US electric power system. When reliability is measured using the system average interruption duration index and the system average interruption frequency index, they find that the distribution system accounts for at least 94 and 92%, respectively, of all interruptions. They also find that these relationships have been stable over the recent past.
- 28 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (5) , 717-723
Open AccessDistribution system versus bulk power system: identifying the source of electric service interruptions in the US
This study reports on the results from efforts by the Institute of Electric and Electronics Engineers (IEEE) Distribution Reliability Working Group (DRWG) and the U.S. Energy Information Administration (EIA) to improve the usefulness of reliability metrics by developing and then applying consistent, yet distinct measures of the continuity of supply based on the portion of the electric power system from which power interruptions originate: the lower voltage distribution system versus the high‐voltage bulk power system. The modified metrics better support reliability planning in the US because they separately measure the effectiveness of actions to improve reliability made by the two distinct groups of firms (and their regulators or oversight bodies) that are responsible for planning and operating each portion of the US electric power system. The authors then present for the first time quantitative information on the reliability of each portion of the US electric power system. When reliability is measured using the system average interruption duration index and the system average interruption frequency index, they find that the distribution system accounts for at least 94 and 92%, respectively, of all interruptions. They also find that these relationships have been stable over the recent past.