HLHangtian Lei

Hangtian Lei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hangtian Lei has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of line distance elements for various IBR controllers and system conditions

    by Paulo Henrique Pinheiro, Bruno W. França, Yona Lopes, Soham Chakraborty, Rômulo G. Bainy, Hangtian Lei, Brian K. Johnson, Scott Manson, Jing Wang, Rasel Mahmud, et al.


  • Impact of Resistive SFCLs on Supervising Elements in Transmission Line Protection

    by Hangtian Lei, Brian K. Johnson

    Power system transmission line protective relays are supervised by a number of elements to ensure the security and selectivity of protection decisions. Supervising elements are important for fault direction determination and they are typically designed based on the properties of sequence currents and voltages. Superconducting fault current limiters (SFCLs) could potentially affect the profiles of sequence currents and voltages, which could have further influence on the performance of supervising elements. This article is one of the first works that investigate the impact of resistive SFCLs on supervising elements in power system transmission line protection. A resistive SFCL and an electric power system are modeled in an electromagnetic transients simulation program. Single-line-to-ground faults are simulated on the transmission line. The acquired fault voltages and currents are processed by a transmission line impedance-based protective relay model to investigate the responses of supervising elements. The results are analyzed and discussed.


  • Impact of Saturated Iron Core Superconducting Fault Current Limiters on Traveling-Wave-Based Protection

    by Hangtian Lei, Jianzhong Gui, Brian K. Johnson

    Traveling wave based protection schemes provide fast clearance options for transmission line faults and have been increasingly used in electric power grids in recent years. Superconducting fault current limiters (SFCLs) change the impedance properties of transmission line terminals and inevitably affect protection functions based on traveling wave principles. This paper is the first work that investigates the influence of saturated iron core SFCLs on traveling wave based protection in electric power grid applications. An electric power transmission system with a saturated iron core SFCL is modeled in an electromagnetic transients simulation program. We use a frequency dependent line model to represent transmission lines so that transient features can be effectively captured. Single line to ground faults are simulated in the system. The resulting traveling waves are acquired and thoroughly analyzed. The results show that the profiles of current traveling waves are significantly impacted by the saturated iron core SFCL and the performance of traveling wave based protection is potentially affected. Possible mitigation strategies and directions for future studies are discussed.


  • Open Access

    Operational resilience metrics for power systems with penetration of renewable resources

    by Jianzhong Gui, Hangtian Lei, Timothy R. McJunkin, Bo Chen, Brian K. Johnson

    Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.


  • Open Access

    Resiliency Improvement of an AC/DC Power Grid with Embedded LCC-HVDC Using Robust Power System State Estimation

    by Abdulwahab A. Aljabrine, Abdallah A. Smadi, Yacine Chakhchoukh, Brian K. Johnson, Hangtian Lei

    The growth of renewable energy generation in the power grid brings attention to high-voltage direct current (HVDC) transmission as a valuable solution for stabilizing the system. Robust hybrid power system state estimation could enhance the resilience of the control of these systems. This paper proposes a two-stage, highly robust least-trimmed squares (LTS)-based estimator. The first step combines the supervisory control and data acquisition (SCADA) measurements using the robust LTS-based estimator. The second step merges the obtained state results with the available phasor measurement units (PMUs) measurements using a robust Huber M-estimator. The proposed robust LTS-based estimator shows good performance in the presence of Gaussian measurement noise. The proposed estimator is shown to resist and correct the effect of false data injection (FDI) attacks and random errors on the measurement vector and the Jacobian matrix. The state estimation (SE) is executed on a modified version of the CIGRE bipole LCC-HVDC benchmark model integrated into the IEEE 12-bus AC dynamic test system. The obtained simulation results confirm the effectiveness and robustness of the proposed two-stage LTS-based SE.


  • A New Measure of Operating Speed and Consistency of Digital Protection Instruments Based on IEC 60255

    by Jun-Soo Kim, Jae-Sung Lim, Jae-Young Park, Young-Jin Kim, Hangtian Lei

    Assessing and installing digital protection relays with higher operating performances are essential to improve the continuity of service in power networks. This article proposes a new test procedure for comparative evaluation of the dynamic performance of digital relays particularly with respect to their response speed and consistency. In the proposed test procedure, relay operating times are measured for various fault scenarios established based on the IEC 60255 standard. The measurement data are processed to calculate the averages, weighted variances, and distribution functions of the relay operating times. Given the statistics, four new indices are developed to calculate total performance scores for relative comparison of the relays. Simulation studies are conducted on the proposed and conventional test procedures when applied to several types of protection relays. Experimental studies are also carried out using real relays in a hardware-in-the-loop simulation setup. The study results verify that the proposed test procedure and numerical indices lead to comparative total scores, large decidability index values, and small equipment variation values, thus ensuring effectiveness and robustness in assessing relative performances of relays.


  • Impact of Resistive SFCLs on Superimposed Quantities in Power System Faults

    by Hangtian Lei, Husam Samkari, Yacine Chakhchoukh, Jianzhao Geng, Brian K. Johnson

    Superimposed quantities, also known as delta quantities, are the transient signatures of fault currents and voltages that can be utilized by protective relays to achieve fast fault detection for electric power grid applications. With the installation of superconducting fault current limiters (SFCLs) on power transmission lines, the profiles of superimposed quantities in power system faults are affected due to the altered impedance properties at transmission line terminals, which may further affect protective relay performance. In this article, we investigate the impact of a resistive SFCL on superimposed quantity profiles. The equivalent circuit of a resistive SFCL connected to an electric power transmission system is first illustrated based on which the simulation model is established in an electromagnetic transients program. Various types of power transmission line faults are simulated. The superimposed current and voltage quantities at transmission line terminals are obtained. The simulation results demonstrate that the acquired superimposed quantities are significantly affected by the SFCL. Possible consequences to protection functions are discussed.


  • Open Access

    A Comprehensive Survey on Cyber-Physical Smart Grid Testbed Architectures: Requirements and Challenges

    by Abdallah A. Smadi, Babatunde Tobi Ajao, Brian K. Johnson, Hangtian Lei, Yacine Chakhchoukh, Qasem Abu Al-Haija

    The integration of improved control techniques with advanced information technologies enables the rapid development of smart grids. The necessity of having an efficient, reliable, and flexible communication infrastructure is achieved by enabling real-time data exchange between numerous intelligent and traditional electrical grid elements. The performance and efficiency of the power grid are enhanced with the incorporation of communication networks, intelligent automation, advanced sensors, and information technologies. Although smart grid technologies bring about valuable economic, social, and environmental benefits, testing the combination of heterogeneous and co-existing Cyber-Physical-Smart Grids (CP-SGs) with conventional technologies presents many challenges. The examination for both hardware and software components of the Smart Grid (SG) system is essential prior to the deployment in real-time systems. This can take place by developing a prototype to mimic the real operational circumstances with adequate configurations and precision. Therefore, it is essential to summarize state-of-the-art technologies of industrial control system testbeds and evaluate new technologies and vulnerabilities with the motivation of stimulating discoveries and designs. In this paper, a comprehensive review of the advancement of CP-SGs with their corresponding testbeds including diverse testing paradigms has been performed. In particular, we broadly discuss CP-SG testbed architectures along with the associated functions and main vulnerabilities. The testbed requirements, constraints, and applications are also discussed. Finally, the trends and future research directions are highlighted and specified.


  • Open Access

    A Methodology for Remote Sensing Inter-Turn Fault Events in Power System Air-Core Reactors, via Simulation of Magneto Quasi-Static Fields in 2D FDTD

    by Ata Zadehgol, Hangtian Lei, Brian K. Johnson

    We present a numerical methodology to estimate the transient fault currents and to simulate the remote sensing of transient fault information embedded in the magnetic field emissions caused by inter-turn shorts in 60 Hz air-core reactors, thru a magneto quasi-static (MQS) field approximation in the method of Finite-Difference Time-Domain (FDTD) in 2-dimensional (2D) space. The MQS 2D FDTD fields of reactor in normal operation are scaled by correlation against an equivalent circuit model that is derived from application of basic physics principles to parameters of the 3D air-core reactor. The proposed multi-scale quasi-static modeling methodology, based on the reduced c modification, provides fine-feature access down to the single-wire level and can efficiently estimate the transient fault fields and currents due to turn-to-turn short in a reactor with core height in several meters, core diameter in meters, wire diameter in millimeters, and number of turns in the thousands, at 60 Hz; this is accomplished by using computational resources of a typical laptop computer within seconds or minutes, as opposed to days that would be otherwise required without the reduced c modification.