Jing Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jing Tang has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Arman Rahmim
The University of British Columbia
11 shared publications - Andi Li
Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
6 shared publications - Bao Yang
Department of Electrical and Computer Engineering, Oakland University, Rochester, MI, USA
5 shared publications Bao Yang
Department of Electrical and Computer Engineering, Oakland University, Rochester, MI, USA
3 shared publications- Matthew Paul Adams
Department of Electrical and Computer Engineering, Oakland University, Rochester, MI, USA
3 shared publications Xinhui Wang
Department of Electrical and Computer Engineering, Oakland University, Rochester, MI, USA
3 shared publications
Latest Publications
- 5 November 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 64
Sharpening the signal in gated single-photon emission computed tomography: From noise suppression to clinical validation
- 5 November 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 64
Sharpening the signal in gated single-photon emission computed tomography: From noise suppression to clinical validation
- Open Access
- 3 November 2026
- Published by Elsevier in NeuroImage
NA-DIP: A Noise-Aware Deep Image Prior for Generating Dedicated Brain PET–Quality Images from Whole-Body PET Acquisitions
- 3 November 2026
- Published by Elsevier in NeuroImage
Open AccessNA-DIP: A Noise-Aware Deep Image Prior for Generating Dedicated Brain PET–Quality Images from Whole-Body PET Acquisitions
- Open Access
- 21 May 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learning
Deep learning (DL)-based denoising methods have shown promise for reducing radiation dose and/or acquisition time in pediatric PET imaging. However, conventional DL approaches typically require large and diverse training datasets to achieve generalizability. We propose a patch-based DL (PDL) approach that learns local structural representations from a single high-quality examination, with the goal of improving image quality and preserving quantitative accuracy of reduced-count pediatric whole-body PET while minimizing training burden. This retrospective study included PET/CT datasets acquired on a GE Discovery MI Gen 2 scanner. A single pediatric examination with high structural conspicuity and low noise was used for training. Testing was performed using a NEMA phantom and 88 clinical pediatric examinations (age < 12 years) acquired with routine pediatric FDG dosing and a 90‑s‑per‑bed protocol. Clinical list‑mode data were truncated to 20 s per bed to simulate reduced‑count acquisitions; training and phantom datasets were downsampled to match this noise level. The PDL model was trained using paired full‑count and reduced‑count image patches and applied to denoise reduced‑count phantom and patient images. Phantom evaluations assessed spatial resolution, contrast recovery, and noise. Clinical evaluation included a blinded observer study and quantitative SUV analysis, followed by assessment of the noise-bias tradeoff. PDL preserved spatial resolution and contrast while achieving substantial noise reduction in phantom experiments. In the observer study, PDL‑enhanced 20‑s‑per‑bed images were rated as equivalent or superior in overall image quality and noise relative to standard 90‑s‑per‑bed images in more than 85% of cases. Small negative relative bias in SUVmax and SUVmean was observed in the liver, mediastinal blood pool, and lesions, with no statistically significant differences compared with standard‑count images. Compared with highly regularized reconstruction, PDL achieved greater noise reduction with reduced bias. PDL enhancement for pediatric whole-body PET imaging may enable a reduction in acquisition time to 20 s per bed or a reduction in administered activity to approximately 22% of current clinical practice, while maintaining spatial resolution, contrast, quantitative accuracy, and diagnostic image quality.
- 21 May 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessAcquisition time/dose reduction in pediatric PET imaging using patch-based deep learning
Deep learning (DL)-based denoising methods have shown promise for reducing radiation dose and/or acquisition time in pediatric PET imaging. However, conventional DL approaches typically require large and diverse training datasets to achieve generalizability. We propose a patch-based DL (PDL) approach that learns local structural representations from a single high-quality examination, with the goal of improving image quality and preserving quantitative accuracy of reduced-count pediatric whole-body PET while minimizing training burden. This retrospective study included PET/CT datasets acquired on a GE Discovery MI Gen 2 scanner. A single pediatric examination with high structural conspicuity and low noise was used for training. Testing was performed using a NEMA phantom and 88 clinical pediatric examinations (age < 12 years) acquired with routine pediatric FDG dosing and a 90‑s‑per‑bed protocol. Clinical list‑mode data were truncated to 20 s per bed to simulate reduced‑count acquisitions; training and phantom datasets were downsampled to match this noise level. The PDL model was trained using paired full‑count and reduced‑count image patches and applied to denoise reduced‑count phantom and patient images. Phantom evaluations assessed spatial resolution, contrast recovery, and noise. Clinical evaluation included a blinded observer study and quantitative SUV analysis, followed by assessment of the noise-bias tradeoff. PDL preserved spatial resolution and contrast while achieving substantial noise reduction in phantom experiments. In the observer study, PDL‑enhanced 20‑s‑per‑bed images were rated as equivalent or superior in overall image quality and noise relative to standard 90‑s‑per‑bed images in more than 85% of cases. Small negative relative bias in SUVmax and SUVmean was observed in the liver, mediastinal blood pool, and lesions, with no statistically significant differences compared with standard‑count images. Compared with highly regularized reconstruction, PDL achieved greater noise reduction with reduced bias. PDL enhancement for pediatric whole-body PET imaging may enable a reduction in acquisition time to 20 s per bed or a reduction in administered activity to approximately 22% of current clinical practice, while maintaining spatial resolution, contrast, quantitative accuracy, and diagnostic image quality.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Dose Reduction in Dynamic PET Imaging Using Self-Supervised Two-Step Deep Image Prior
Reducing the radiotracer dose in dynamic brain PET imaging lowers patient radiation exposure but also degrades the signal-to-noise (SNR) ratio and introduces bias in both dynamic frames and resulting parametric images. These effects compromise the accuracy of quantitative assessments of target proteins. In this study, we propose a self-supervised two-step deep image prior (TS-DIP) method that integrates composite image-based pretraining with individual frame-based fine-tuning to enhance reduced-dose dynamic brain PET imaging. We evaluated the TS-DIP method on 1/10-count dynamic datasets acquired using two tracers with distinct uptake patterns, 11C-UCB-J (targeting synaptic density) and 11C-LSN3172176 (targeting muscarinic cholinergic receptors). Compared with conventional, supervised deep learning, and conditional DIP denoising approaches, the TS-DIP demonstrated a superior tradeoff between noise reduction and bias in both dynamic frames and parametric images. Averaged across all dynamic frames of 11C-UCB-J subjects, the proposed method achieved a 75% reduction in noise with an bias of 2.1%, corresponding to 63% and 60% noise reduction in the K1 (bias, -1.2%) and VT (bias, -3.1%) parametric images, respectively. For 11C-LSN3172176 subjects, the average noise reductions (bias) were 80% (3.4%) in dynamic frames, 62%(-0.38%) in K1 images, and 77% (-3.4%) in VT images. These results highlight the generalizability of the proposed TS-DIP method across tracers with varying activity distributions and its potential to enable accurate, reduced-dose dynamic brain PET imaging without the need for large training datasets.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Dose Reduction in Dynamic PET Imaging Using Self-Supervised Two-Step Deep Image Prior
Reducing the radiotracer dose in dynamic brain PET imaging lowers patient radiation exposure but also degrades the signal-to-noise (SNR) ratio and introduces bias in both dynamic frames and resulting parametric images. These effects compromise the accuracy of quantitative assessments of target proteins. In this study, we propose a self-supervised two-step deep image prior (TS-DIP) method that integrates composite image-based pretraining with individual frame-based fine-tuning to enhance reduced-dose dynamic brain PET imaging. We evaluated the TS-DIP method on 1/10-count dynamic datasets acquired using two tracers with distinct uptake patterns, 11C-UCB-J (targeting synaptic density) and 11C-LSN3172176 (targeting muscarinic cholinergic receptors). Compared with conventional, supervised deep learning, and conditional DIP denoising approaches, the TS-DIP demonstrated a superior tradeoff between noise reduction and bias in both dynamic frames and parametric images. Averaged across all dynamic frames of 11C-UCB-J subjects, the proposed method achieved a 75% reduction in noise with an bias of 2.1%, corresponding to 63% and 60% noise reduction in the K1 (bias, -1.2%) and VT (bias, -3.1%) parametric images, respectively. For 11C-LSN3172176 subjects, the average noise reductions (bias) were 80% (3.4%) in dynamic frames, 62%(-0.38%) in K1 images, and 77% (-3.4%) in VT images. These results highlight the generalizability of the proposed TS-DIP method across tracers with varying activity distributions and its potential to enable accurate, reduced-dose dynamic brain PET imaging without the need for large training datasets.
- Open Access
- 13 March 2026
- Published by Elsevier in NeuroImage
- Vol. 331, 121853
Dose reduction for synaptic density PET imaging in Parkinson’s disease
- 13 March 2026
- Published by Elsevier in NeuroImage
- Vol. 331, 121853
Open AccessDose reduction for synaptic density PET imaging in Parkinson’s disease
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2738-2749
Deep Image Prior-Incorporated Direct PET Parametric Image Reconstruction
Direct parametric reconstruction algorithms have been developed to improve the statistical reliability of parametric images estimated from dynamic PET imaging data. However, these estimates are degraded by noise due to measurement error and noise propagation during reconstruction. In this study, we develop a deep image prior (DIP) regularized direct reconstruction method, where the DIP network is used to represent the estimated parametric image. By initializing the DIP with pre-trained weights and updating its network to learn the intermediate information during reconstruction, the DIP regularization leverages the available population and subject-specific features. The proposed method is applied to reconstruct K1 from both simulated and patient data acquired by 82Rb dynamic PET myocardial perfusion imaging. Benefiting from the nonlinear representation capability of the DIP network, the proposed method achieves superior noise versus bias/mean performance compared with the indirect and direct reconstruction methods with various regularizations formed by quadratic smoothness, dictionary learning, or fully-connected neural network. To summarize, the proposed method demonstrates its potential in improving the precision of dynamic PET imaging measurements, which will contribute to diagnostic accuracy and disease monitoring.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2738-2749
Deep Image Prior-Incorporated Direct PET Parametric Image Reconstruction
Direct parametric reconstruction algorithms have been developed to improve the statistical reliability of parametric images estimated from dynamic PET imaging data. However, these estimates are degraded by noise due to measurement error and noise propagation during reconstruction. In this study, we develop a deep image prior (DIP) regularized direct reconstruction method, where the DIP network is used to represent the estimated parametric image. By initializing the DIP with pre-trained weights and updating its network to learn the intermediate information during reconstruction, the DIP regularization leverages the available population and subject-specific features. The proposed method is applied to reconstruct K1 from both simulated and patient data acquired by 82Rb dynamic PET myocardial perfusion imaging. Benefiting from the nonlinear representation capability of the DIP network, the proposed method achieves superior noise versus bias/mean performance compared with the indirect and direct reconstruction methods with various regularizations formed by quadratic smoothness, dictionary learning, or fully-connected neural network. To summarize, the proposed method demonstrates its potential in improving the precision of dynamic PET imaging measurements, which will contribute to diagnostic accuracy and disease monitoring.
- Open Access
- 8 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (24) , 245006
Dose reduction in dynamic synaptic vesicle glycoprotein 2A PET imaging using artificial neural networks
Objective . Reducing dose in positron emission tomography (PET) imaging increases noise in reconstructed dynamic frames, which inevitably results in higher noise and possible bias in subsequently estimated images of kinetic parameters than those estimated in the standard dose case. We report the development of a spatiotemporal denoising technique for reduced-count dynamic frames through integrating a cascade artificial neural network (ANN) with the highly constrained back-projection (HYPR) scheme to improve low-dose parametric imaging. Approach . We implemented and assessed the proposed method using imaging data acquired with 11 C-UCB-J, a PET radioligand bound to synaptic vesicle glycoprotein 2A (SV2A) in the human brain. The patch-based ANN was trained with a reduced-count frame and its full-count correspondence of a subject and was used in cascade to process dynamic frames of other subjects to further take advantage of its denoising capability. The HYPR strategy was then applied to the spatial ANN processed image frames to make use of the temporal information from the entire dynamic scan. Main results . In all the testing subjects including healthy volunteers and Parkinson’s disease patients, the proposed method reduced more noise while introducing minimal bias in dynamic frames and the resulting parametric images, as compared with conventional denoising methods. Significance . Achieving 80% noise reduction with a bias of −2% in dynamic frames, which translates into 75% and 70% of noise reduction in the tracer uptake (bias, −2%) and distribution volume (bias, −5%) images, the proposed ANN+HYPR technique demonstrates the denoising capability equivalent to a 11-fold dose increase for dynamic SV2A PET imaging with 11 C-UCB-J.
- 8 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (24) , 245006
Open AccessDose reduction in dynamic synaptic vesicle glycoprotein 2A PET imaging using artificial neural networks
Objective . Reducing dose in positron emission tomography (PET) imaging increases noise in reconstructed dynamic frames, which inevitably results in higher noise and possible bias in subsequently estimated images of kinetic parameters than those estimated in the standard dose case. We report the development of a spatiotemporal denoising technique for reduced-count dynamic frames through integrating a cascade artificial neural network (ANN) with the highly constrained back-projection (HYPR) scheme to improve low-dose parametric imaging. Approach . We implemented and assessed the proposed method using imaging data acquired with 11 C-UCB-J, a PET radioligand bound to synaptic vesicle glycoprotein 2A (SV2A) in the human brain. The patch-based ANN was trained with a reduced-count frame and its full-count correspondence of a subject and was used in cascade to process dynamic frames of other subjects to further take advantage of its denoising capability. The HYPR strategy was then applied to the spatial ANN processed image frames to make use of the temporal information from the entire dynamic scan. Main results . In all the testing subjects including healthy volunteers and Parkinson’s disease patients, the proposed method reduced more noise while introducing minimal bias in dynamic frames and the resulting parametric images, as compared with conventional denoising methods. Significance . Achieving 80% noise reduction with a bias of −2% in dynamic frames, which translates into 75% and 70% of noise reduction in the tracer uptake (bias, −2%) and distribution volume (bias, −5%) images, the proposed ANN+HYPR technique demonstrates the denoising capability equivalent to a 11-fold dose increase for dynamic SV2A PET imaging with 11 C-UCB-J.
- 14 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (12) , 3485-3497
Dictionary Learning Constrained Direct Parametric Estimation in Dynamic Myocardial Perfusion PET
In myocardial perfusion imaging with dynamic positron emission tomography (PET), direct parametric reconstruction from the projection data allows accurate modeling of the Poisson noise in the projection domain to provide more reliable estimate of the parametric images. In this study, we propose to incorporate a superior denoiser to efficiently suppress the unfavorable noise propagation during the direct reconstruction. The dictionary learning (DL) based sparse representation serves as a regularization term to constrain the intermediate ${K}_{{1}}$ estimation. We rewrite the DL regularizer into a voxel-separable form to facilitate the decoupling of a DL penalized curve fitting from the reconstruction of dynamic frames. The nonlinear fitting is then solved by a damped Newton method with uniform initialization. Using simulated and patient 82 Rb dynamic PET data, we study the performance of the proposed DL direct algorithm and quantitatively compare it with the indirect method with or without post-filtering, the direct reconstruction without regularization, and the quadratic penalty regularized direct algorithm. The DL regularized direct reconstruction achieves improved noise versus bias performance in the reconstructed ${K}_{{1}}$ images as well as superior recovery of a reduced myocardial blood flow defect. The dictionary learned from a 3D self-created hollow sphere image yields comparable results to those using the dictionary learned from the corresponding magnetic resonance image. The uniform initializations converge to ${K}_{{1}}$ estimations similar to the result from initializing with the indirect reconstruction. To summarize, we demonstrate the potential of the proposed DL constrained direct parametric reconstruction in improving quantitative dynamic PET imaging.
- 14 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (12) , 3485-3497
Dictionary Learning Constrained Direct Parametric Estimation in Dynamic Myocardial Perfusion PET
In myocardial perfusion imaging with dynamic positron emission tomography (PET), direct parametric reconstruction from the projection data allows accurate modeling of the Poisson noise in the projection domain to provide more reliable estimate of the parametric images. In this study, we propose to incorporate a superior denoiser to efficiently suppress the unfavorable noise propagation during the direct reconstruction. The dictionary learning (DL) based sparse representation serves as a regularization term to constrain the intermediate ${K}_{{1}}$ estimation. We rewrite the DL regularizer into a voxel-separable form to facilitate the decoupling of a DL penalized curve fitting from the reconstruction of dynamic frames. The nonlinear fitting is then solved by a damped Newton method with uniform initialization. Using simulated and patient 82 Rb dynamic PET data, we study the performance of the proposed DL direct algorithm and quantitatively compare it with the indirect method with or without post-filtering, the direct reconstruction without regularization, and the quadratic penalty regularized direct algorithm. The DL regularized direct reconstruction achieves improved noise versus bias performance in the reconstructed ${K}_{{1}}$ images as well as superior recovery of a reduced myocardial blood flow defect. The dictionary learned from a 3D self-created hollow sphere image yields comparable results to those using the dictionary learned from the corresponding magnetic resonance image. The uniform initializations converge to ${K}_{{1}}$ estimations similar to the result from initializing with the indirect reconstruction. To summarize, we demonstrate the potential of the proposed DL constrained direct parametric reconstruction in improving quantitative dynamic PET imaging.
- 1 May 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 132, 104312
Improved motor outcome prediction in Parkinson's disease applying deep learning to DaTscan SPECT images
- 1 May 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 132, 104312
Improved motor outcome prediction in Parkinson's disease applying deep learning to DaTscan SPECT images
- 3 April 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145010
Improved myocardial perfusion PET imaging using artificial neural networks
Myocardial perfusion (MP) PET imaging plays a key role in risk assessment and stratification of patients with coronary artery disease. In this work, we proposed a patch-based artificial neural network (ANN) fusion approach that integrates information from the maximum-likelihood (ML) and the post-smoothed ML reconstruction to improve MP PET imaging. To enhance quantification and tasked-based MP defect detection, the proposed method fused features from patches of the ML and the post-smoothed ML reconstructed images with different noise levels and spatial resolution. Using the XCAT phantom, we simulated three MP PET datasets, one with normal perfusion and the other two with non-transmural and transmural regionally reduced perfusion of the left ventricular (LV) myocardium. The proposed ANN fusion technique was quantitatively evaluated in terms of noise-bias and noise-contrast tradeoff, and compared with the post-smoothed ML reconstruction. Using the channelized Hotelling observer, we evaluated the detectability of the non-transmural and transmural defects through a receiver operating characteristic analysis. The quantitative results demonstrated that the ANN enhancement method reduced bias and improved contrast while reaching comparable noise to that of the post-smoothed ML reconstruction. Moreover, the ANN fusion technique significantly improved the defect detectability of both non-transmural and transmural defects. In addition to the simulation study, we further evaluated the ANN enhancement method on patient data. Compared with the post-smoothed ML reconstruction, the ANN fusion method improved the tradeoff between noise and mean on the LV myocardium, indicating its potential clinical value in MP PET imaging.
- 3 April 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145010
Improved myocardial perfusion PET imaging using artificial neural networks
Myocardial perfusion (MP) PET imaging plays a key role in risk assessment and stratification of patients with coronary artery disease. In this work, we proposed a patch-based artificial neural network (ANN) fusion approach that integrates information from the maximum-likelihood (ML) and the post-smoothed ML reconstruction to improve MP PET imaging. To enhance quantification and tasked-based MP defect detection, the proposed method fused features from patches of the ML and the post-smoothed ML reconstructed images with different noise levels and spatial resolution. Using the XCAT phantom, we simulated three MP PET datasets, one with normal perfusion and the other two with non-transmural and transmural regionally reduced perfusion of the left ventricular (LV) myocardium. The proposed ANN fusion technique was quantitatively evaluated in terms of noise-bias and noise-contrast tradeoff, and compared with the post-smoothed ML reconstruction. Using the channelized Hotelling observer, we evaluated the detectability of the non-transmural and transmural defects through a receiver operating characteristic analysis. The quantitative results demonstrated that the ANN enhancement method reduced bias and improved contrast while reaching comparable noise to that of the post-smoothed ML reconstruction. Moreover, the ANN fusion technique significantly improved the defect detectability of both non-transmural and transmural defects. In addition to the simulation study, we further evaluated the ANN enhancement method on patient data. Compared with the post-smoothed ML reconstruction, the ANN fusion method improved the tradeoff between noise and mean on the LV myocardium, indicating its potential clinical value in MP PET imaging.