WKWern Kam

Wern Kam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wern Kam has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Water Phantom Characterization of a Novel Optical Fiber Sensor for LDR Brachytherapy

    by Michael Martyn, Wern Kam, Peter Woulfe, Sinead O'KEeffe

    This work considers the feasibility of using a novel optical fiber based sensor, employing a Terbium-doped Gadolinium Oxysulfide (Gd2O2S:Tb) inorganic scintillator, as a real-time in-vivo dosimetry solution for applications in low dose rate (LDR) prostate brachytherapy (BT). This study specifically considers the influence of scintillator geometry (hemi-sphere tip vs cylindrical cavity), PMMA fiber core diameter (0.5 mm vs 1.0 mm), and sensor housing material (stainless steel vs plastic) on the measured scintillation signal. Characterization measurements were performed using a Silicon Photon-Multiplier (SiPM) detector and a commercial water phantom system, integrated with custom 3D printed components to allow for precise positioning of the LDR BT radiation source with respect to the optical fiber sensor. Significant differences in the rate of fall-off in the scintillation signal, with distance from the source, were observed between the different scintillator geometries considered. The hemi-sphere tip geometry was shown to be the most accurate, tracking with the expected fall-off in dose-rate, within measurement uncertainty. Reducing the fiber core diameter from 1.0 mm to 0.5 mm resulted in a 6-fold reduction in the detected scintillation signal. A further 57 % reduction was observed when housing the 0.5 mm fiber within a stainless steel LDR BT needle applicator. Initial results demonstrate the feasibility of employing an optical fiber sensor, for applications in LDR BT, given the excellent agreement of measurements with theoretical expectations. Furthermore a calibration process has been described for converting the detected scintillation signal into absorbed dose / dose-rate, using our water phantom based experimental set-up.


  • Open Access

    An Analytical Model for Describing the Power Coupling Ratio between Multimode Fibers with Transverse Displacement and Angular Misalignment in an Optical Fiber Bend Sensor

    by Wern Kam, Yong Sheng Ong, Sinead O’keeffe, Waleed S. Mohammed, Elfed Lewis

    The power coupling ratio between step-index multimode fibers caused by combined transversal and angular misalignment is calculated. A theoretical description of the coupling efficiency between two optical fibers based on geometrical optics is provided. The theoretical calculations are collaborated by experiments, determining the power coupling ratio between three output fibers with an axial offset and angular misalignment with a single input fiber. The calculation results are in good agreement with experimental results obtained using a previously fabricated optical fiber sensor for monitoring physiological parameters in clinical environments. The theoretical results are particularly beneficial for optimizing the design of optical fiber bending sensors that are based on power coupling loss (intensity) as the measurement interrogation requires either axial displacement, angular misalignment, or both.


  • Open Access

    A Validation Study of a Polymer Optical Fiber Sensor for Monitoring Lumbar Spine Movement

    by Wern Kam, Mary O’keeffe, Kieran O’sullivan, Waleed S. Mohammed, Sinead O’keeffe, Elfed Lewis, Charusluk Viphavakit

    This study aims to investigate the validity and reliability of a novel plastic optical fiber (POF) sensor, which was developed to measure the angles of flexion, extension and lateral bend at the lumbar region. The angles of flexion, extension and lateral bend for a standing position were measured simultaneously using both the novel POF sensor of this investigation and the commercial Biometrics goniometer instrument. Each movement had two steps of bending which were 10° and 20° based on inclinometer readings. The POF sensor had good intra-rater reliability (Intraclass correlation coefficient, ICC = 0.61 to 0.83). Bland–Altman plots were used to study the agreement using these two sensors. There were proportional differences and bias between the POF sensor and Biometrics goniometer, as the zero points did not lie in the percentage difference region in the Bland–Altman plots. The proportional difference between these two likely reflects the different sizes and thus, measurement regions of the two sensors. There was also strong correlation between the two sensors (r > 0.77). Hence, the POF sensor could be of potential utility in measuring lumbar range of motion (ROM) in a manner which is minimally invasive, and where discrete sections of the spine are under specific investigation.


  • Fabrication and simulation studies on D-shaped optical fiber sensor via surface plasmon resonance

    by R. Zakaria, W. Kam, Y. S. Ong, S. F. A. Z. Yusoff, H. Ahmad, Waleed S. Mohammed

    This paper describes simulation and experimental methods for designing a D-shaped surface plasmon resonance (SPR) fibre sensor. The sensor consists of two set-up approaches. Finite element method is used in simulation on the fibre sensor device. Two experimental methods for detecting relative intensity are used by varying the wavelength of the optical signal sources and the thickness of gold layer coated on the D-shaped fibre. In the first method, the sensor device works by detecting the relative intensity of two optical signal sources having different wavelengths. In the second set-up, the relative intensity between two D-shaped fibres coated with different thicknesses of gold is measured when a single signal source is launched at the input. The difference in intensities of the signal outputs is used to estimate the refractive index at the sensing region. A prototype SPR D-shaped fibre sensor has been fabricated and the experimental results show good agreement with simulation.


  • Open Access

    Low-Cost Transducer Based On Surface Scattering Using Side-Polished D-Shaped Optical Fibers

    by Y. S. Ong, W. Kam, S. W. Harun, R. Zakaria, Waleed S. Mohammed

    This work presents a new low-cost and environmentally friendly optical transducer based on surface scattering in a side-polished fiber mounted on a glass groove. The surface roughness caused by polishing is used to estimate the change in refractive index on top of the fiber. Changing the surrounding index affects the scattering properties and, consequently, the leakage of the guided mode. This effect is experimentally investigated through the change in the attenuation coefficient when the surrounding refractive index is changed by dropping different weight ratios of glucose solutions onto the polished side. The measured change of the attenuation coefficient is consistent with the finite-element calculations. The effect of different polished depths was theoretically investigated to optimize the working conditions.


  • Fabrication of polymer microfiber through direct drawing and splicing of silica microfiber via vapor spray and flame treatment

    by Y. S. Ong, W. Kam, S. W. Harun, R. Zakaria

    We report a simple fabrication technique of polymer microfibers with high surface smoothness and length uniformity using a molten polymethylmethacrylate in conjunction with direct drawing technique. With the aid of fabricated polymer microfibers, we successfully demonstrate a new splicing technique via a two-step process. The fabricated microfibers with diameter of 1.5 μm and length of 3 mm have been used in splicing the silica microfibers based on solvent vapor spray and flame treatment process. We were able to obtain an average splicing loss of about −0.69  dB. Using the same technique, we also demonstrated splicing for ring resonators. The splicing technique demonstrated in this work promises high potential for robust optical integration of microfibers for various functional circuits and devices.


  • Adaptive Neuro-Fuzzy Evaluation of the Tapered Plastic Multimode Fiber-Based Sensor Performance With and Without Silver Thin Film for Different Concentrations of Calcium Hypochlorite

    by Rozalina Zakaria, Ong Yong Sheng, Kam Wern, Shahaboddin Shamshirband, Dalibor Petkovic, Nenad T. Pavlovic

    An adaptive neurofuzzy (ANFIS) evaluation study has been applied on tapered plastic multimode sensors. This study is basically using tapered plastic multimode fiber polymethyl methacrylate (PMMA) optical as a sensor. It is proposed and demonstrated for continuous monitoring of solutions based on different concentration of sodium chloride and glucose in deionized water. The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 and 10 mm, respectively. In addition, a tapered PMMA probe, which was coated by silver film, was fabricated and demonstrated using calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observation increment in the transmission of the sensor that is immersed in solutions at higher concentration. As the concentration varies from 0 to 6 ppm, the output voltage of the sensor increases linearly from 3.61 to 4.28 mV with a sensitivity of 0.1154 mV/ppm and a linearity of more than 99.47%. The silver film coating increases the sensitivity of the proposed sensor due to the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. To estimate the output voltage response of the sensors with and without silver film, this paper constructed a process, which simulates the sensors voltage output in regard to different concentration of calcium hypochlorite with ANFIS method. This intelligent estimator is implemented using MATLAB/SIMULINK and the performances are investigated. The simulation results presented in this paper show the effectiveness of the developed method.


  • Examination of tapered plastic multimode fiber-based sensor performance with silver coating for different concentrations of calcium hypochlorite by soft computing methodologies—a comparative study

    by Rozalina Zakaria, Ong Yong Sheng, Kam Wern, Shahaboddin Shamshirband, Ainuddin Wahid Abdul Wahab, Dalibor Petković, Hadi Saboohi

    A soft methodology study has been applied on tapered plastic multimode sensors. This study basically used tapered plastic multimode fiber [polymethyl methacrylate (PMMA)] optics as a sensor. The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 and 10 mm, respectively. In addition, a tapered PMMA probe, which was coated by silver film, was fabricated and demonstrated using a calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observation increment in the transmission of the sensor that is immersed in solutions at high concentrations. As the concentration was varied from 0 to 6 ppm, the output voltage of the sensor increased linearly. The silver film coating increased the sensitivity of the proposed sensor because of the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. In this study, the polynomial and radial basis function (RBF) were applied as the kernel function of the support vector regression (SVR) to estimate and predict the output voltage response of the sensors with and without silver film according to experimental tests. Instead of minimizing the observed training error, SVR_poly and SVR_rbf were used in an attempt to minimize the generalization error bound so as to achieve generalized performance. An adaptive neuro-fuzzy interference system (ANFIS) approach was also investigated for comparison. The experimental results showed that improvements in the predictive accuracy and capacity for generalization can be achieved by the SVR_poly approach in comparison to the SVR_rbf methodology. The same testing errors were found for the SVR_poly approach and the ANFIS approach.


  • Evaluation of the tapered PMMA fiber sensor response due to the ionic interaction within electrolytic solutions

    by M. Batumalay, H.A. Rahman, W. Kam, Y.S. Ong, F. Ahmad, R. Zakaria, S.W. Harun, H. Ahmad

    A tapered plastic multimode fiber (PMMA) optical sensor is proposed and demonstrated for continuous monitoring of solutions based on different concentration of sodium chloride and glucose in deionized water The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 mm and 10 mm, respectively, and was used to investigate the effect of straight, U-shape, and knot shape against concentration for both sodium chloride and glucose. The results show that there is a strong dependence of the electrolytic and non-electrolytic nature of the chemical solutions on the sensor output. It is found that the sensitivity of the sodium chloride concentration sensor with the straight tapered fiber probe was 0.0023 mV/%, which was better than the other probe arrangements of U-shape and knot. Meanwhile, the glucose sensor performs with the highest sensitivity of 0.0026 mV/wt % with the knot-shaped tapered fiber probe. In addition, a tapered PMMA probe which was coated by silver film was fabricated and demonstrated using calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observed increment in the transmission of the sensor that is immersed in solutions of higher concentration. As the concentration varies from 0 ppm to 6 ppm, the output voltage of the sensor increases linearly from 3.61 mV to 4.28 mV with a sensitivity of 0.1154 mV/ppm and a linearity of more than 99.47%. The silver film coating increases the sensitivity of the proposed sensor due to the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber.