Kuddusi Karaboduk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kuddusi Karaboduk has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Erdogan Hasdemir
GAZİ ÜNİVERSİTESİ, FEN FAKÜLTESİ, KİMYA BÖLÜMÜ
1 shared publication Erdoğan HASDEMİR
Gazi Univ, Fac Sci, Dept Chem, TR-06500 Ankara, Turkey
1 shared publication- Hatice Karaboduk
Department of Biology, Faculty of Science, Gazi University, Ankara, Türkiye
1 shared publication
Latest Publications
- 30 November 2024
- Published by Springer Nature in Journal of Food Measurement and Characterization
- Vol. 19 (1) , 390-400
Rapid and simple electrochemical approximation for the determination of the food additive amaranth using voltammetric sensor
- 30 November 2024
- Published by Springer Nature in Journal of Food Measurement and Characterization
- Vol. 19 (1) , 390-400
Rapid and simple electrochemical approximation for the determination of the food additive amaranth using voltammetric sensor
- 10 June 2021
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 68 (9) , 1722-1730
Development of a voltammetric method for the determination of rapamycin in pharmaceutical samples at pretreated pencil graphite electrode
This paper describes an electroanalytical method for the determination of rapamycin using a pretreated pencil graphite electrode (P‐PGE) by differential pulse voltammetry. The electrodes were successfully characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, and Fourier transform infrared. The influences of instrumental and chemical parameters were investigated and optimized for the determination of rapamycin. Oxidation peak current obtained for rapamycin at P‐PGE was 10.5 times higher than that obtained for PGE. In pH = 3.0 H3PO4, a well‐defined irreversible anodic peak occurred at 1.07 V, which was attributed to the electro‐oxidation of rapamycin at P‐PGE. Under optimized conditions, the oxidation peak current of rapamycin was linear with its concentration in the range of 0.01–250 μmol/L, and the detection limit was 0.0075 μmol/L (S/N = 3). Also, the P‐PGE exhibited good reproducibility (relative SD [RSD] = 2.17% for 10 electrodes at different times using the same procedure), repeatability (RSD = 2.09% for 10 measurements with same electrode), and stability (95.80% for 10 days). The P‐PGE was simple to prepare and the method was successfully applied for the determination of rapamycin in spiked and real samples. In addition, for comparison, high‐performance liquid chromatographic method with ultraviolet (UV) detector was used for the determination of rapamycin.
- 10 June 2021
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 68 (9) , 1722-1730
Development of a voltammetric method for the determination of rapamycin in pharmaceutical samples at pretreated pencil graphite electrode
This paper describes an electroanalytical method for the determination of rapamycin using a pretreated pencil graphite electrode (P‐PGE) by differential pulse voltammetry. The electrodes were successfully characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, and Fourier transform infrared. The influences of instrumental and chemical parameters were investigated and optimized for the determination of rapamycin. Oxidation peak current obtained for rapamycin at P‐PGE was 10.5 times higher than that obtained for PGE. In pH = 3.0 H3PO4, a well‐defined irreversible anodic peak occurred at 1.07 V, which was attributed to the electro‐oxidation of rapamycin at P‐PGE. Under optimized conditions, the oxidation peak current of rapamycin was linear with its concentration in the range of 0.01–250 μmol/L, and the detection limit was 0.0075 μmol/L (S/N = 3). Also, the P‐PGE exhibited good reproducibility (relative SD [RSD] = 2.17% for 10 electrodes at different times using the same procedure), repeatability (RSD = 2.09% for 10 measurements with same electrode), and stability (95.80% for 10 days). The P‐PGE was simple to prepare and the method was successfully applied for the determination of rapamycin in spiked and real samples. In addition, for comparison, high‐performance liquid chromatographic method with ultraviolet (UV) detector was used for the determination of rapamycin.
- Open Access
- 28 December 2020
- Published by Oxford University Press (OUP) in Food Quality and Safety
- Vol. 5
Modification of screen-printed gold electrode with 1,4-dithiothreitol: application to sensitive voltammetric determination of Sudan II
The aim of this study is to investigate the electrochemical behavior of Sudan II (SuII) using a screen printed gold electrode (SPGE) modified with 1,4-dithiothreitol (DTT) and to determine the amount of Sudan II by voltammetry. A DTT modified screen printed gold electrode (DTT/SPGE) was fabricated and its application for differential pulse voltammetric (DPV) determination of SuII was reported. Fourier transform infrared spectroscopy (FT-IR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy were used for the characterization of modified electrode. The effects of instrumental and chemical parameters were optimized for the determination of SuII. The fabricated electrode was used for the analysis of SuII in fortified and real samples. High performance liquid chromatography (HPLC) was preferred as a reference method for the evaluation of the obtained voltammetric results. The electrochemical studies and FT-IR demonstrated that the SPGE was modified with DTT. The obtained peak current at DTT/SPGE was 6.67 times higher than that recorded with SPGE. At the optimized conditions of DPV in pH = 2.5 of H2SO4, the oxidation peak current of SuII was proportional to its concentration in range: 0.001 - 1.500 μmol L -1 with a detection limit of 0.0002 μmol L -1 (S/N=3). For the analysis of SuII, 101.67 - 104.33% of recovery percentage was obtained. A new electrode was successfully improved for the determination of SuII. This highly selective and sensitive electrode supplied the fast determination of SuII in ketchup, chili sauce and salsa dip sauce. In addition, voltammetric and chromatographic results are found to be consistent.
- 28 December 2020
- Published by Oxford University Press (OUP) in Food Quality and Safety
- Vol. 5
Open AccessModification of screen-printed gold electrode with 1,4-dithiothreitol: application to sensitive voltammetric determination of Sudan II
The aim of this study is to investigate the electrochemical behavior of Sudan II (SuII) using a screen printed gold electrode (SPGE) modified with 1,4-dithiothreitol (DTT) and to determine the amount of Sudan II by voltammetry. A DTT modified screen printed gold electrode (DTT/SPGE) was fabricated and its application for differential pulse voltammetric (DPV) determination of SuII was reported. Fourier transform infrared spectroscopy (FT-IR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy were used for the characterization of modified electrode. The effects of instrumental and chemical parameters were optimized for the determination of SuII. The fabricated electrode was used for the analysis of SuII in fortified and real samples. High performance liquid chromatography (HPLC) was preferred as a reference method for the evaluation of the obtained voltammetric results. The electrochemical studies and FT-IR demonstrated that the SPGE was modified with DTT. The obtained peak current at DTT/SPGE was 6.67 times higher than that recorded with SPGE. At the optimized conditions of DPV in pH = 2.5 of H2SO4, the oxidation peak current of SuII was proportional to its concentration in range: 0.001 - 1.500 μmol L -1 with a detection limit of 0.0002 μmol L -1 (S/N=3). For the analysis of SuII, 101.67 - 104.33% of recovery percentage was obtained. A new electrode was successfully improved for the determination of SuII. This highly selective and sensitive electrode supplied the fast determination of SuII in ketchup, chili sauce and salsa dip sauce. In addition, voltammetric and chromatographic results are found to be consistent.
- 1 January 2020
- Published by Romanian Academy - Revue Roumaine De Chimie in Revue Roumaine de Chimie
- Vol. 65 (4) , 375-385
Simultaneous determination of quercetin and luteolin in mate and white tea samples
- 1 January 2020
- Published by Romanian Academy - Revue Roumaine De Chimie in Revue Roumaine de Chimie
- Vol. 65 (4) , 375-385
Simultaneous determination of quercetin and luteolin in mate and white tea samples
- 31 May 2019
- Published by Wiley in ChemistrySelect
- Vol. 4 (20) , 6361-6369
Electrochemical Determination of Ascorbic Acid Based on AgNPs/PVP‐Modified Glassy Carbon Electrode
The electrochemical determination of ascorbic acid was carried out at the surface of glassy carbon electrode (GCE) modified by silver nanoparticles (AgNPs):Polyvinylpyrrolidone (PVP). Nanocomposite was evaluated by fourier transform infrared spectroscopy, zeta potential, and X‐ray diffraction. Also, the surface morphologies of the developed electrode were investigated by scanning electron microscopy, and profilometer. The electrochemical performance of AgNPs/PVP/GCE was studied with cyclic voltammetry and electrochemical impedance spectroscopy measurements. The electrochemical studies demonstrated that the electrode had a large surface. Compared with the bare GCE, PVP/GCE, and AgNPs/GCE, the AgNPs/PVP‐modified GCE showed excellent performance for the electrochemical determination of ascorbic acid. At the optimized conditions of differential pulse voltammetry in pH 6.0 of phosphate buffer solution, the modified electrode allowed the determination of ascorbic acid on a potential of 0.54 V vs. Ag/AgCl. Under optimized conditions, the low detection limit of 0.047 μM and working range of 0.2‐1200 μM were obtained at the AgNPs/PVP/GCE. The AgNPs/PVP/GCE allowed to obtain highest peak current values at low concentrations. Moreover, the fabricated electrode also exhibited good repeatability, reproducibility, and stability. The developed electrode was successfully enforced for the analysis of ascorbic acid in banana, kiwi fruit, mango, and pineapple.
- 31 May 2019
- Published by Wiley in ChemistrySelect
- Vol. 4 (20) , 6361-6369
Electrochemical Determination of Ascorbic Acid Based on AgNPs/PVP‐Modified Glassy Carbon Electrode
The electrochemical determination of ascorbic acid was carried out at the surface of glassy carbon electrode (GCE) modified by silver nanoparticles (AgNPs):Polyvinylpyrrolidone (PVP). Nanocomposite was evaluated by fourier transform infrared spectroscopy, zeta potential, and X‐ray diffraction. Also, the surface morphologies of the developed electrode were investigated by scanning electron microscopy, and profilometer. The electrochemical performance of AgNPs/PVP/GCE was studied with cyclic voltammetry and electrochemical impedance spectroscopy measurements. The electrochemical studies demonstrated that the electrode had a large surface. Compared with the bare GCE, PVP/GCE, and AgNPs/GCE, the AgNPs/PVP‐modified GCE showed excellent performance for the electrochemical determination of ascorbic acid. At the optimized conditions of differential pulse voltammetry in pH 6.0 of phosphate buffer solution, the modified electrode allowed the determination of ascorbic acid on a potential of 0.54 V vs. Ag/AgCl. Under optimized conditions, the low detection limit of 0.047 μM and working range of 0.2‐1200 μM were obtained at the AgNPs/PVP/GCE. The AgNPs/PVP/GCE allowed to obtain highest peak current values at low concentrations. Moreover, the fabricated electrode also exhibited good repeatability, reproducibility, and stability. The developed electrode was successfully enforced for the analysis of ascorbic acid in banana, kiwi fruit, mango, and pineapple.
- 1 January 2018
- Published by Faculty of Food Technology and Biotechnology - University of Zagreb in Food Technology and Biotechnology
- Vol. 56 (4) , 573-580
Voltammetric Determination of Sudan 1 in Food Samples Using Its Cu(II) Compound
In this work, we developed a sensitive, simple and convenient electrochemical method to determine Sudan 1 in food samples using its Cu(II) coordination compound. Using phosphate buffer solution at pH=5.0 as supporting electrolyte (75% methanol), differential pulse voltammetry and 6-fold concentration of Cu(II), the electrochemical oxidation signal of Sudan 1-Cu(II) coordination compound at glassy carbon electrode significantly increased when compared to the one without the added Cu(II). The experimental conditions such as the amount of methanol, pH, the concentration of Cu(II) and the instrumental parameter were optimized for the determination of Sudan 1. Under the optimal experimental conditions, the oxidation peak current of Sudan 1 was proportional to its concentration in two ranges: 0.04-0.09 to 0.09-5.3 µM with a detection limit of 0.71 nM (S/N=3). The interference effects of Sudan 2-4 with the determination of Sudan 1 was also evaluated. The developed method was successfully applied to tomato, chilli sauces, ketchup and chilli powder. The analysis results of Sudan 1 in food samples obtained by the proposed method were in a good agreement with the reference values detected by HPLC.
- 1 January 2018
- Published by Faculty of Food Technology and Biotechnology - University of Zagreb in Food Technology and Biotechnology
- Vol. 56 (4) , 573-580
Voltammetric Determination of Sudan 1 in Food Samples Using Its Cu(II) Compound
In this work, we developed a sensitive, simple and convenient electrochemical method to determine Sudan 1 in food samples using its Cu(II) coordination compound. Using phosphate buffer solution at pH=5.0 as supporting electrolyte (75% methanol), differential pulse voltammetry and 6-fold concentration of Cu(II), the electrochemical oxidation signal of Sudan 1-Cu(II) coordination compound at glassy carbon electrode significantly increased when compared to the one without the added Cu(II). The experimental conditions such as the amount of methanol, pH, the concentration of Cu(II) and the instrumental parameter were optimized for the determination of Sudan 1. Under the optimal experimental conditions, the oxidation peak current of Sudan 1 was proportional to its concentration in two ranges: 0.04-0.09 to 0.09-5.3 µM with a detection limit of 0.71 nM (S/N=3). The interference effects of Sudan 2-4 with the determination of Sudan 1 was also evaluated. The developed method was successfully applied to tomato, chilli sauces, ketchup and chilli powder. The analysis results of Sudan 1 in food samples obtained by the proposed method were in a good agreement with the reference values detected by HPLC.