Maxime Raison
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maxime Raison has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Sofiane Achiche
Department of Biomedical Engineering, Polytechnique Montréal, Montreal, QC, Canada
9 shared publications Christine Detrembleur
3 shared publications- Laurent Ballaz
Department of Physical Activity Sciences, Université du Québec à Montréal, Canada; Groupe de Recherche en Activité Physique Adaptée (GRAPA), Montreal, Canada
3 shared publications - Paul Fisette
Mechatronic, Electrical Energy, and Dynamic Systems (MEED), Institute of Mechanics, Materials and Civil Engineering (iMMC), Université Catholique de Louvain, 1348 Louvain-la-Neuve, Belgium
3 shared publications - Philippe Mahaudens
Université Catholique de Louvain, Institut de Recherche Expérimentale et Clinique
3 shared publications - Sana Raouafi
Institute of Biomedical Engineering, École Polytéchnique de Montréal
3 shared publications
Latest Publications
- Open Access
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Design and Manufacturing of a 3D-Printed Anchorage for Dynamic Orthotic Devices
In the field of rehabilitation, dynamic orthotic devices for the shoulder and elbow may be clinically prescribed to patients with myopathy, deformities, and general body weakness. Considering the last advancements in technologies for additive manufacturing, a 3D-Printed model for the device was initially developed to conceptualize a lightweight and custom-made design. To assemble the system, a 3D-Printed anchorage module is required to assure that the device is properly fixed on a rigid back that covers the patient’s torso and to provide an alternative strategy to brace’s traditional manufacturing methods. Since the device’s ergonomy and stability are both highly dependent on the flexural stiffness and global weight of the anchorage, the design of an optimized rigid back remains crucial. The main objective of this project is to design, manufacture, and test a 3D-printed spinal brace anchorage for upper limb dynamic orthotic devices. Using Autodesk Fusion360 and Ultimaker 5S, a selected design scenario was developed in the CAD environment and manufactured. Also, studies using Finite Element Analysis (FEA) were performed to aid the design process. Further tests should be conducted on other subjects to prove the efficiency of the model that was proposed.
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessDesign and Manufacturing of a 3D-Printed Anchorage for Dynamic Orthotic Devices
In the field of rehabilitation, dynamic orthotic devices for the shoulder and elbow may be clinically prescribed to patients with myopathy, deformities, and general body weakness. Considering the last advancements in technologies for additive manufacturing, a 3D-Printed model for the device was initially developed to conceptualize a lightweight and custom-made design. To assemble the system, a 3D-Printed anchorage module is required to assure that the device is properly fixed on a rigid back that covers the patient’s torso and to provide an alternative strategy to brace’s traditional manufacturing methods. Since the device’s ergonomy and stability are both highly dependent on the flexural stiffness and global weight of the anchorage, the design of an optimized rigid back remains crucial. The main objective of this project is to design, manufacture, and test a 3D-printed spinal brace anchorage for upper limb dynamic orthotic devices. Using Autodesk Fusion360 and Ultimaker 5S, a selected design scenario was developed in the CAD environment and manufactured. Also, studies using Finite Element Analysis (FEA) were performed to aid the design process. Further tests should be conducted on other subjects to prove the efficiency of the model that was proposed.
- 17 January 2025
- Published by Springer Nature in Applied Intelligence
- Vol. 55 (5) , 1-21
Real-time trajectory prediction of a ping-pong ball using a GRU-TAE
- 17 January 2025
- Published by Springer Nature in Applied Intelligence
- Vol. 55 (5) , 1-21
Real-time trajectory prediction of a ping-pong ball using a GRU-TAE
- Open Access
- 18 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8405
Design of Minimal Model-Free Control Structure for Fast Trajectory Tracking of Robotic Arms
This paper designs a minimal neural network (NN)-based model-free control structure for the fast, accurate trajectory tracking of robotic arms, crucial for large movements, velocities, and accelerations. Trajectory tracking requires an accurate dynamic model or aggressive feedback. However, such models are hard to obtain due to nonlinearities and uncertainties, especially in low-cost, 3D-printed robotic arms. A recently proposed model-free architecture has used an NN for the dynamic compensation of a proportional derivative controller, but the minimal requirements and optimal conditions remain unclear, leading to overly complex architectures. This study aims to identify these requirements and design a minimal NN-based model-free control structure for trajectory tracking. Two architectures are compared, one NN per joint (INN) and one global NN (GNN), each tested on two serial robotic arms in simulations and real scenarios. The results show that the architecture reduces tracking errors (RMSE < 2°). The INN is accurate for decoupled joint dynamics and requires fewer training data than the GNN. A table summarizes the design process. Future works will apply this control structure to low-cost robotic arms and micro-movements.
- 18 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8405
Open AccessDesign of Minimal Model-Free Control Structure for Fast Trajectory Tracking of Robotic Arms
This paper designs a minimal neural network (NN)-based model-free control structure for the fast, accurate trajectory tracking of robotic arms, crucial for large movements, velocities, and accelerations. Trajectory tracking requires an accurate dynamic model or aggressive feedback. However, such models are hard to obtain due to nonlinearities and uncertainties, especially in low-cost, 3D-printed robotic arms. A recently proposed model-free architecture has used an NN for the dynamic compensation of a proportional derivative controller, but the minimal requirements and optimal conditions remain unclear, leading to overly complex architectures. This study aims to identify these requirements and design a minimal NN-based model-free control structure for trajectory tracking. Two architectures are compared, one NN per joint (INN) and one global NN (GNN), each tested on two serial robotic arms in simulations and real scenarios. The results show that the architecture reduces tracking errors (RMSE < 2°). The INN is accurate for decoupled joint dynamics and requires fewer training data than the GNN. A table summarizes the design process. Future works will apply this control structure to low-cost robotic arms and micro-movements.
- Open Access
Transcutaneous Functional Electrical Stimulation Controlled by a System of Sensors for the Lower Limbs: A Systematic Review
In the field of transcutaneous functional electrical stimulation (FES), open-loop and closed-loop control strategies have been developed to restore functions of the lower limbs: walking, standing up, maintaining posture, and cycling. These strategies require sensors that provide feedback information on muscle activity or biomechanics of movement. Since muscle response induced by transcutaneous FES is nonlinear, time-varying, and dependent on muscle fatigue evolution, the choice of sensor type and control strategy becomes critical. The main objective of this review is to provide state-of-the-art, emerging, current, and previous solutions in terms of control strategies. Focus is given on transcutaneous FES systems for the lower limbs. Using Compendex and Inspec databases, a total of 135 review and conference articles were included in this review. Recent studies mainly use inertial sensors, although the use of electromyograms for lower limbs has become more frequent. Currently, several researchers are opting for nonlinear controllers to overcome the nonlinear and time-varying effects of FES. More development is needed in the field of systems using inertial sensors for nonlinear control. Further studies are needed to validate nonlinear control systems in patients with neuromuscular disorders.
Open AccessTranscutaneous Functional Electrical Stimulation Controlled by a System of Sensors for the Lower Limbs: A Systematic Review
In the field of transcutaneous functional electrical stimulation (FES), open-loop and closed-loop control strategies have been developed to restore functions of the lower limbs: walking, standing up, maintaining posture, and cycling. These strategies require sensors that provide feedback information on muscle activity or biomechanics of movement. Since muscle response induced by transcutaneous FES is nonlinear, time-varying, and dependent on muscle fatigue evolution, the choice of sensor type and control strategy becomes critical. The main objective of this review is to provide state-of-the-art, emerging, current, and previous solutions in terms of control strategies. Focus is given on transcutaneous FES systems for the lower limbs. Using Compendex and Inspec databases, a total of 135 review and conference articles were included in this review. Recent studies mainly use inertial sensors, although the use of electromyograms for lower limbs has become more frequent. Currently, several researchers are opting for nonlinear controllers to overcome the nonlinear and time-varying effects of FES. More development is needed in the field of systems using inertial sensors for nonlinear control. Further studies are needed to validate nonlinear control systems in patients with neuromuscular disorders.
- Open Access
- 16 July 2021
- Published by ASME International
On Supporting the Learning of Biomechanics Using Multidisciplinary Physical Prototyping
*Over the last decades, the use of multibody dynamics in biomechanics research has grown considerably and holds significant promises for the health and biomedical industries. Nowadays, it allows estimating internal data of the body that would be impractical or impossible to obtain experimentally, e.g. individual muscle forces. Also, multibody dynamics simulation allows one to
- 16 July 2021
- Published by ASME International
Open AccessOn Supporting the Learning of Biomechanics Using Multidisciplinary Physical Prototyping
*Over the last decades, the use of multibody dynamics in biomechanics research has grown considerably and holds significant promises for the health and biomedical industries. Nowadays, it allows estimating internal data of the body that would be impractical or impossible to obtain experimentally, e.g. individual muscle forces. Also, multibody dynamics simulation allows one to
- Open Access
Current Trends and Challenges in Pediatric Access to Sensorless and Sensor-Based Upper Limb Exoskeletons
Sensorless and sensor-based upper limb exoskeletons that enhance or support daily motor function are limited for children. This review presents the different needs in pediatrics and the latest trends when developing an upper limb exoskeleton and discusses future prospects to improve accessibility. First, the principal diagnoses in pediatrics and their respective challenge are presented. A total of 14 upper limb exoskeletons aimed for pediatric use were identified in the literature. The exoskeletons were then classified as sensorless or sensor-based, and categorized with respect to the application domain, the motorization solution, the targeted population(s), and the supported movement(s). The relative absence of upper limb exoskeleton in pediatrics is mainly due to the additional complexity required in order to adapt to children’s growth and answer their specific needs and usage. This review highlights that research should focus on sensor-based exoskeletons, which would benefit the majority of children by allowing easier adjustment to the children’s needs. Sensor-based exoskeletons are often the best solution for children to improve their participation in activities of daily living and limit cognitive, social, and motor impairments during their development.
Open AccessCurrent Trends and Challenges in Pediatric Access to Sensorless and Sensor-Based Upper Limb Exoskeletons
Sensorless and sensor-based upper limb exoskeletons that enhance or support daily motor function are limited for children. This review presents the different needs in pediatrics and the latest trends when developing an upper limb exoskeleton and discusses future prospects to improve accessibility. First, the principal diagnoses in pediatrics and their respective challenge are presented. A total of 14 upper limb exoskeletons aimed for pediatric use were identified in the literature. The exoskeletons were then classified as sensorless or sensor-based, and categorized with respect to the application domain, the motorization solution, the targeted population(s), and the supported movement(s). The relative absence of upper limb exoskeleton in pediatrics is mainly due to the additional complexity required in order to adapt to children’s growth and answer their specific needs and usage. This review highlights that research should focus on sensor-based exoskeletons, which would benefit the majority of children by allowing easier adjustment to the children’s needs. Sensor-based exoskeletons are often the best solution for children to improve their participation in activities of daily living and limit cognitive, social, and motor impairments during their development.
- 4 November 2020
- Published by Springer Nature in Pflügers Archiv - European Journal of Physiology
- Vol. 472 (12) , 1661-1663
Is the understanding of V̇O2 kinetics biased by the first-order multi-exponential model?
- 4 November 2020
- Published by Springer Nature in Pflügers Archiv - European Journal of Physiology
- Vol. 472 (12) , 1661-1663
Is the understanding of V̇O2 kinetics biased by the first-order multi-exponential model?
- Open Access
- 29 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7626
Motion Planning of Upper-Limb Exoskeleton Robots: A Review
(1) Background: Motion planning is an important part of exoskeleton control that improves the wearer’s safety and comfort. However, its usage introduces the problem of trajectory planning. The objective of trajectory planning is to generate the reference input for the motion-control system. This review explores the methods of trajectory planning for exoskeleton control. In order to reduce the number of surveyed papers, this review focuses on the upper limbs, which require refined three-dimensional motion planning. (2) Methods: A systematic search covering the last 20 years was conducted in Ei Compendex, Inspect-IET, Web of Science, PubMed, ProQuest, and Science-Direct. The search strategy was to use and combine terms “trajectory planning”, “upper limb”, and ”exoskeleton” as high-level keywords. “Trajectory planning” and “motion planning” were also combined with the following keywords: “rehabilitation”, “humanlike motion“, “upper extremity“, “inverse kinematic“, and “learning machine “. (3) Results: A total of 67 relevant papers were discovered. Results were then classified into two main categories of methods to plan trajectory: (i) Approaches based on Cartesian motion planning, and inverse kinematics using polynomial-interpolation or optimization-based methods such as minimum-jerk, minimum-torque-change, and inertia-like models; and (ii) approaches based on “learning by demonstration” using machine-learning techniques such as supervised learning based on neural networks, and learning methods based on hidden Markov models, Gaussian mixture models, and dynamic motion primitives. (4) Conclusions: Various methods have been proposed to plan the trajectories for upper-limb exoskeleton robots, but most of them plan the trajectory offline. The review approach is general and could be extended to lower limbs. Trajectory planning has the advantage of extending the applicability of therapy robots to home usage (assistive exoskeletons); it also makes it possible to mitigate the shortages of medical caregivers and therapists, and therapy costs. In this paper, we also discuss challenges associated with trajectory planning: kinematic redundancy and incompatibility, and the trajectory-optimization problem. Commonly, methods based on the computation of swivel angles and other methods rely on the relationship (e.g., coordinated or synergistic) between the degrees of freedom used to resolve kinematic redundancy for exoskeletons. Moreover, two general solutions, namely, the self-tracing configuration of the joint axis and the alignment-free configuration of the joint axis, which add the appropriate number of extra degrees of freedom to the mechanism, were employed to improve the kinematic incompatibility between human and exoskeleton. Future work will focus on online trajectory planning and optimal control. This will be done because very few online methods were found in the scope of this study.
- 29 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7626
Open AccessMotion Planning of Upper-Limb Exoskeleton Robots: A Review
(1) Background: Motion planning is an important part of exoskeleton control that improves the wearer’s safety and comfort. However, its usage introduces the problem of trajectory planning. The objective of trajectory planning is to generate the reference input for the motion-control system. This review explores the methods of trajectory planning for exoskeleton control. In order to reduce the number of surveyed papers, this review focuses on the upper limbs, which require refined three-dimensional motion planning. (2) Methods: A systematic search covering the last 20 years was conducted in Ei Compendex, Inspect-IET, Web of Science, PubMed, ProQuest, and Science-Direct. The search strategy was to use and combine terms “trajectory planning”, “upper limb”, and ”exoskeleton” as high-level keywords. “Trajectory planning” and “motion planning” were also combined with the following keywords: “rehabilitation”, “humanlike motion“, “upper extremity“, “inverse kinematic“, and “learning machine “. (3) Results: A total of 67 relevant papers were discovered. Results were then classified into two main categories of methods to plan trajectory: (i) Approaches based on Cartesian motion planning, and inverse kinematics using polynomial-interpolation or optimization-based methods such as minimum-jerk, minimum-torque-change, and inertia-like models; and (ii) approaches based on “learning by demonstration” using machine-learning techniques such as supervised learning based on neural networks, and learning methods based on hidden Markov models, Gaussian mixture models, and dynamic motion primitives. (4) Conclusions: Various methods have been proposed to plan the trajectories for upper-limb exoskeleton robots, but most of them plan the trajectory offline. The review approach is general and could be extended to lower limbs. Trajectory planning has the advantage of extending the applicability of therapy robots to home usage (assistive exoskeletons); it also makes it possible to mitigate the shortages of medical caregivers and therapists, and therapy costs. In this paper, we also discuss challenges associated with trajectory planning: kinematic redundancy and incompatibility, and the trajectory-optimization problem. Commonly, methods based on the computation of swivel angles and other methods rely on the relationship (e.g., coordinated or synergistic) between the degrees of freedom used to resolve kinematic redundancy for exoskeletons. Moreover, two general solutions, namely, the self-tracing configuration of the joint axis and the alignment-free configuration of the joint axis, which add the appropriate number of extra degrees of freedom to the mechanism, were employed to improve the kinematic incompatibility between human and exoskeleton. Future work will focus on online trajectory planning and optimal control. This will be done because very few online methods were found in the scope of this study.
- 1 September 2020
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 280, 103479
Second-order simultaneous components model for the overshoot and “slow component” in V̇O2 kinetics
- 1 September 2020
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 280, 103479
Second-order simultaneous components model for the overshoot and “slow component” in V̇O2 kinetics
- Open Access
- 3 January 2020
- Published by MDPI AG in Preprints.org
Robot-Assisted Therapy Influence on Kinematic and EMG Activity in the Upper Limb for Children with Cerebral Palsy
Aim: To develop an index for quantitative assessment of the upper limb motor function in children with cerebral palsy before and after robot-assisted therapy. Method: An upper limb motor function index was developed using kinematic, surface electromyography and three-axis inertial measurements unit data collected from 15 children with cerebral palsy (CP) and 15 typically developed children. Children with CP underwent 18 robot-assisted therapy sessions with the REAplan device. All children were evaluated, using kinematic data from the REAplan, electromyography and three-axis inertial measurements unit readings from its accelerometer. A principal component analysis was conducted to produce an evaluation index, which is able to detect the deviation from the upper limb motor function of typically developing children group. Children with CP were evaluated twice before and after the intervention with Box and Blocks test and Finger-To-Nose test. The discriminative and concurrent validity of the upper limb motor function index were investigated. Results: The upper limb motor function index was higher in children with CP post therapy (ppr=0.012, p=0.95 and r=0.13, p= 0.54 for Box and Blocks test and Finger-To-Nose test respectively). Interpretation: The upper limb motor function index successfully differentiated between the typically developing children and children with CP and was effective in assessing the improvement of the upper limb motor function after robot-assisted therapy. The upper limb motor function index could be extended to assess and monitor rehabilitation therapies of other populations, such as those with stroke and Parkinson’s disease.
- 3 January 2020
- Published by MDPI AG in Preprints.org
Open AccessRobot-Assisted Therapy Influence on Kinematic and EMG Activity in the Upper Limb for Children with Cerebral Palsy
Aim: To develop an index for quantitative assessment of the upper limb motor function in children with cerebral palsy before and after robot-assisted therapy. Method: An upper limb motor function index was developed using kinematic, surface electromyography and three-axis inertial measurements unit data collected from 15 children with cerebral palsy (CP) and 15 typically developed children. Children with CP underwent 18 robot-assisted therapy sessions with the REAplan device. All children were evaluated, using kinematic data from the REAplan, electromyography and three-axis inertial measurements unit readings from its accelerometer. A principal component analysis was conducted to produce an evaluation index, which is able to detect the deviation from the upper limb motor function of typically developing children group. Children with CP were evaluated twice before and after the intervention with Box and Blocks test and Finger-To-Nose test. The discriminative and concurrent validity of the upper limb motor function index were investigated. Results: The upper limb motor function index was higher in children with CP post therapy (ppr=0.012, p=0.95 and r=0.13, p= 0.54 for Box and Blocks test and Finger-To-Nose test respectively). Interpretation: The upper limb motor function index successfully differentiated between the typically developing children and children with CP and was effective in assessing the improvement of the upper limb motor function after robot-assisted therapy. The upper limb motor function index could be extended to assess and monitor rehabilitation therapies of other populations, such as those with stroke and Parkinson’s disease.