Sinan Hersek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sinan Hersek has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Omer T. Inan
Georgia Institute of Technology, Atlanta, Georgia, USA
11 shared publications - Beren Semiz
Koc Universitesi
6 shared publications - Mobashir Hasan Shandhi
Duke University
3 shared publications - Achin Kulshrestha
Google, Toronto, Ontario, Canada
2 shared publications - Akshay Paruchuri
Google Research, Mountain View, USA
2 shared publications - Andrea Colaço
Google, Mountain View, USA
2 shared publications
Latest Publications
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (11) , 9720-9729
EgoTrigger: Toward Audio-Driven Image Capture for Human Memory Enhancement in All-Day Energy-Efficient Smart Glasses
All-day smart glasses are likely to emerge as platforms capable of continuous contextual sensing, uniquely positioning them for unprecedented assistance in our daily lives. Integrating the multi-modal AI agents required for human memory enhancement while performing continuous sensing, however, presents a major energy efficiency challenge for all-day usage. Achieving this balance requires intelligent, context-aware sensor management. Our approach, EgoTrigger, leverages audio cues from the microphone to selectively activate power-intensive cameras, enabling efficient sensing while preserving substantial utility for human memory enhancement. EgoTrigger uses a lightweight audio model (YAMNet) and a custom classification head to trigger image capture from hand-object interaction (HOI) audio cues, such as the sound of a drawer opening or a medication bottle being opened. In addition to evaluating on the QA-Ego4D dataset, we introduce and evaluate on the Human Memory Enhancement Question-Answer (HME-QA) dataset. Our dataset contains 340 human-annotated first-person QA pairs from full-length Ego4D videos that were curated to ensure that they contained audio, focusing on HOI moments critical for contextual understanding and memory. Our results show EgoTrigger can use 54% fewer frames on average, significantly saving energy in both power-hungry sensing components (e.g., cameras) and downstream operations (e.g., wireless transmission), while achieving comparable performance on datasets for an episodic memory task. We believe this context-aware triggering strategy represents a promising direction for enabling energy-efficient, functional smart glasses capable of all-day use — supporting applications like helping users recall where they placed their keys or information about their routine activities (e.g., taking medications).
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (11) , 9720-9729
EgoTrigger: Toward Audio-Driven Image Capture for Human Memory Enhancement in All-Day Energy-Efficient Smart Glasses
All-day smart glasses are likely to emerge as platforms capable of continuous contextual sensing, uniquely positioning them for unprecedented assistance in our daily lives. Integrating the multi-modal AI agents required for human memory enhancement while performing continuous sensing, however, presents a major energy efficiency challenge for all-day usage. Achieving this balance requires intelligent, context-aware sensor management. Our approach, EgoTrigger, leverages audio cues from the microphone to selectively activate power-intensive cameras, enabling efficient sensing while preserving substantial utility for human memory enhancement. EgoTrigger uses a lightweight audio model (YAMNet) and a custom classification head to trigger image capture from hand-object interaction (HOI) audio cues, such as the sound of a drawer opening or a medication bottle being opened. In addition to evaluating on the QA-Ego4D dataset, we introduce and evaluate on the Human Memory Enhancement Question-Answer (HME-QA) dataset. Our dataset contains 340 human-annotated first-person QA pairs from full-length Ego4D videos that were curated to ensure that they contained audio, focusing on HOI moments critical for contextual understanding and memory. Our results show EgoTrigger can use 54% fewer frames on average, significantly saving energy in both power-hungry sensing components (e.g., cameras) and downstream operations (e.g., wireless transmission), while achieving comparable performance on datasets for an episodic memory task. We believe this context-aware triggering strategy represents a promising direction for enabling energy-efficient, functional smart glasses capable of all-day use — supporting applications like helping users recall where they placed their keys or information about their routine activities (e.g., taking medications).
- Open Access
EgoTrigger: Toward Audio-Driven Image Capture for Human Memory Enhancement in All-Day Energy-Efficient Smart Glasses
All-day smart glasses are likely to emerge as platforms capable of continuous contextual sensing, uniquely positioning them for unprecedented assistance in our daily lives. Integrating the multi-modal AI agents required for human memory enhancement while performing continuous sensing, however, presents a major energy efficiency challenge for all-day usage. Achieving this balance requires intelligent, context-aware sensor management. Our approach, EgoTrigger, leverages audio cues from the microphone to selectively activate power-intensive cameras, enabling efficient sensing while preserving substantial utility for human memory enhancement. EgoTrigger uses a lightweight audio model (YAMNet) and a custom classification head to trigger image capture from hand-object interaction (HOI) audio cues, such as the sound of a drawer opening or a medication bottle being opened. In addition to evaluating on the QA-Ego4D dataset, we introduce and evaluate on the Human Memory Enhancement Question-Answer (HME-QA) dataset. Our dataset contains 340 human-annotated first-person QA pairs from full-length Ego4D videos that were curated to ensure that they contained audio, focusing on HOI moments critical for contextual understanding and memory. Our results show EgoTrigger can use 54% fewer frames on average, significantly saving energy in both power-hungry sensing components (e.g., cameras) and downstream operations (e.g., wireless transmission), while achieving comparable performance on datasets for an episodic memory task. We believe this context-aware triggering strategy represents a promising direction for enabling energy-efficient, functional smart glasses capable of all-day use -- supporting applications like helping users recall where they placed their keys or information about their routine activities (e.g., taking medications).
Open AccessEgoTrigger: Toward Audio-Driven Image Capture for Human Memory Enhancement in All-Day Energy-Efficient Smart Glasses
All-day smart glasses are likely to emerge as platforms capable of continuous contextual sensing, uniquely positioning them for unprecedented assistance in our daily lives. Integrating the multi-modal AI agents required for human memory enhancement while performing continuous sensing, however, presents a major energy efficiency challenge for all-day usage. Achieving this balance requires intelligent, context-aware sensor management. Our approach, EgoTrigger, leverages audio cues from the microphone to selectively activate power-intensive cameras, enabling efficient sensing while preserving substantial utility for human memory enhancement. EgoTrigger uses a lightweight audio model (YAMNet) and a custom classification head to trigger image capture from hand-object interaction (HOI) audio cues, such as the sound of a drawer opening or a medication bottle being opened. In addition to evaluating on the QA-Ego4D dataset, we introduce and evaluate on the Human Memory Enhancement Question-Answer (HME-QA) dataset. Our dataset contains 340 human-annotated first-person QA pairs from full-length Ego4D videos that were curated to ensure that they contained audio, focusing on HOI moments critical for contextual understanding and memory. Our results show EgoTrigger can use 54% fewer frames on average, significantly saving energy in both power-hungry sensing components (e.g., cameras) and downstream operations (e.g., wireless transmission), while achieving comparable performance on datasets for an episodic memory task. We believe this context-aware triggering strategy represents a promising direction for enabling energy-efficient, functional smart glasses capable of all-day use -- supporting applications like helping users recall where they placed their keys or information about their routine activities (e.g., taking medications).
- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (7) , 1887-1898
Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace
The seismocardiogram (SCG) measures the movement of the chest wall in response to underlying cardiovascular events. Though this signal contains clinically-relevant information, its morphology is both patient-specific and highly transient. In light of recent work suggesting the existence of population-level patterns in SCG signals, the objective of this study is to develop a method which harnesses these patterns to enable robust signal processing despite morphological variability. Specifically, we introduce seismocardiogram generative factor encoding (SGFE), which models the SCG waveform as a stochastic sample from a low-dimensional subspace defined by a unified set of generative factors. We then demonstrate that during dynamic processes such as exercise-recovery, learned factors correlate strongly with known generative factors including aortic opening (AO) and closing (AC), following consistent trajectories in subspace despite morphological differences. Furthermore, we found that changes in sensor location affect the perceived underlying dynamic process in predictable ways, thereby enabling algorithmic compensation for sensor misplacement during generative factor inference. Mapping these trajectories to AO and AC yielded ${R^{2}}$ values from 0.81—0.90 for AO and 0.72—0.83 for AC respectively across five sensor positions. Identification of consistent behavior of SCG signals in low dimensions corroborates the existence of population-level patterns in these signals; SGFE may also serve as a harbinger for processing methods that are abstracted from the time domain, which may ultimately improve the feasibility of SCG utilization in ambulatory and outpatient settings.- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (7) , 1887-1898
Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace
The seismocardiogram (SCG) measures the movement of the chest wall in response to underlying cardiovascular events. Though this signal contains clinically-relevant information, its morphology is both patient-specific and highly transient. In light of recent work suggesting the existence of population-level patterns in SCG signals, the objective of this study is to develop a method which harnesses these patterns to enable robust signal processing despite morphological variability. Specifically, we introduce seismocardiogram generative factor encoding (SGFE), which models the SCG waveform as a stochastic sample from a low-dimensional subspace defined by a unified set of generative factors. We then demonstrate that during dynamic processes such as exercise-recovery, learned factors correlate strongly with known generative factors including aortic opening (AO) and closing (AC), following consistent trajectories in subspace despite morphological differences. Furthermore, we found that changes in sensor location affect the perceived underlying dynamic process in predictable ways, thereby enabling algorithmic compensation for sensor misplacement during generative factor inference. Mapping these trajectories to AO and AC yielded ${R^{2}}$ values from 0.81—0.90 for AO and 0.72—0.83 for AC respectively across five sensor positions. Identification of consistent behavior of SCG signals in low dimensions corroborates the existence of population-level patterns in these signals; SGFE may also serve as a harbinger for processing methods that are abstracted from the time domain, which may ultimately improve the feasibility of SCG utilization in ambulatory and outpatient settings.- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (7) , 1899-1906
Detecting Suspected Pump Thrombosis in Left Ventricular Assist Devices via Acoustic Analysis
Objective: Left ventricular assist devices (LVADs) fail in up to 10% of patients due to the development of pump thrombosis. Remote monitoring of patients with LVADs can enable early detection and, subsequently, treatment and prevention of pump thrombosis. We assessed whether acoustical signals measured on the chest of patients with LVADs, combined with machine learning algorithms, can be used for detecting pump thrombosis. Methods: 13 centrifugal pump (HVAD) recipients were enrolled in the study. When hospitalized for suspected pump thrombosis, clinical data and acoustical recordings were obtained at admission, prior to and after administration of thrombolytic therapy, and every 24 hours until laboratory and pump parameters normalized. First, we selected the most important features among our feature set using LDH-based correlation analysis. Then using these features, we trained a logistic regression model and determined our decision threshold to differentiate between thrombosis and non-thrombosis episodes. Results: Accuracy, sensitivity and precision were calculated to be 88.9%, 90.9% and 83.3%, respectively. When tested on the post-thrombolysis data, our algorithm suggested possible pump abnormalities that were not identified by the reference pump power or biomarker abnormalities. Significance: We showed that the acoustical signatures of LVADs can be an index of mechanical deterioration and, when combined with machine learning algorithms, provide clinical decision support regarding the presence of pump thrombosis.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (7) , 1899-1906
Detecting Suspected Pump Thrombosis in Left Ventricular Assist Devices via Acoustic Analysis
Objective: Left ventricular assist devices (LVADs) fail in up to 10% of patients due to the development of pump thrombosis. Remote monitoring of patients with LVADs can enable early detection and, subsequently, treatment and prevention of pump thrombosis. We assessed whether acoustical signals measured on the chest of patients with LVADs, combined with machine learning algorithms, can be used for detecting pump thrombosis. Methods: 13 centrifugal pump (HVAD) recipients were enrolled in the study. When hospitalized for suspected pump thrombosis, clinical data and acoustical recordings were obtained at admission, prior to and after administration of thrombolytic therapy, and every 24 hours until laboratory and pump parameters normalized. First, we selected the most important features among our feature set using LDH-based correlation analysis. Then using these features, we trained a logistic regression model and determined our decision threshold to differentiate between thrombosis and non-thrombosis episodes. Results: Accuracy, sensitivity and precision were calculated to be 88.9%, 90.9% and 83.3%, respectively. When tested on the post-thrombolysis data, our algorithm suggested possible pump abnormalities that were not identified by the reference pump power or biomarker abnormalities. Significance: We showed that the acoustical signatures of LVADs can be an index of mechanical deterioration and, when combined with machine learning algorithms, provide clinical decision support regarding the presence of pump thrombosis.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (6) , 2365-2374
Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation
Objective: Systolic time intervals, such as the pre-ejection period (PEP), are important parameters for assessing cardiac contractility that can be measured non-invasively using seismocardiography (SCG). Recent studies have shown that specific points on accelerometer- and gyroscope-based SCG signals can be used for PEP estimation. However, the complex morphology and inter-subject variation of the SCG signal can make this assumption very challenging and increase the root mean squared error (RMSE) when these techniques are used to develop a global model. Methods: In this study, we compared gyroscope- and accelerometer-based SCG signals, individually and in combination, for estimating PEP to show the efficacy of these sensors in capturing valuable information regarding cardiovascular health. We extracted general time-domain features from all the axes of these sensors and developed global models using various regression techniques. Results: In single-axis comparison of gyroscope and accelerometer, angular velocity signal around head to foot axis from the gyroscope provided the lowest RMSE of 12.63 ± 0.49 ms across all subjects. The best estimate of PEP, with a RMSE of 11.46 ± 0.32 ms across all subjects, was achieved by combining features from the gyroscope and accelerometer. Our global model showed 30% lower RMSE when compared to algorithms used in recent literature. Conclusion: Gyroscopes can provide better PEP estimation compared to accelerometers located on the mid-sternum. Global PEP estimation models can be improved by combining general time domain features from both sensors. Significance: This work can be used to develop a low-cost wearable heart-monitoring device and to generate a universal estimation model for systolic time intervals using a single- or multiple-sensor fusion.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 23 (6) , 2365-2374
Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation
Objective: Systolic time intervals, such as the pre-ejection period (PEP), are important parameters for assessing cardiac contractility that can be measured non-invasively using seismocardiography (SCG). Recent studies have shown that specific points on accelerometer- and gyroscope-based SCG signals can be used for PEP estimation. However, the complex morphology and inter-subject variation of the SCG signal can make this assumption very challenging and increase the root mean squared error (RMSE) when these techniques are used to develop a global model. Methods: In this study, we compared gyroscope- and accelerometer-based SCG signals, individually and in combination, for estimating PEP to show the efficacy of these sensors in capturing valuable information regarding cardiovascular health. We extracted general time-domain features from all the axes of these sensors and developed global models using various regression techniques. Results: In single-axis comparison of gyroscope and accelerometer, angular velocity signal around head to foot axis from the gyroscope provided the lowest RMSE of 12.63 ± 0.49 ms across all subjects. The best estimate of PEP, with a RMSE of 11.46 ± 0.32 ms across all subjects, was achieved by combining features from the gyroscope and accelerometer. Our global model showed 30% lower RMSE when compared to algorithms used in recent literature. Conclusion: Gyroscopes can provide better PEP estimation compared to accelerometers located on the mid-sternum. Global PEP estimation models can be improved by combining general time domain features from both sensors. Significance: This work can be used to develop a low-cost wearable heart-monitoring device and to generate a universal estimation model for systolic time intervals using a single- or multiple-sensor fusion.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (5) , 1296-1309
A Globalized Model for Mapping Wearable Seismocardiogram Signals to Whole-Body Ballistocardiogram Signals Based on Deep Learning
The ballistocardiography (BCG) signal is a measurement of the vibrations of the center of mass of the body due to the cardiac cycle and can be used for noninvasive hemodynamic monitoring. The seismocardiography (SCG) signals measure the local vibrations of the chest wall due to the cardiac cycle. While BCG is a more well known modality, it requires the use of a modified bathroom scale or a force plate and cannot be measured in a wearable setting, whereas SCG signals can be measured using wearable accelerometers placed on the sternum. In this work we explore the idea of finding a mapping between zero mean and unit $\ell_2$ -norm SCG and BCG signal segments such that, the BCG signal can be acquired using wearable accelerometers (without retaining amplitude information). We use neural networks to find such a mapping and make use of the recently introduced UNet architecture. We trained our models on 26 healthy subjects and tested them on 10 subjects. Our results show that we can estimate the aforementioned segments of the BCG signal with a median Pearson correlation coefficient of 0.71 and a median absolute deviation (MAD) of 0.17. Furthermore, our model can estimate the R-I, R-J and R-K timing intervals with median absolute errors (and MAD) of 10.00 (8.90), 6.00 (5.93) and 8.00 (5.93), respectively. We show that using all three axis of the SCG accelerometer produces the best results while the head-to-foot SCG signal produces the best results when a single SCG axis is used.- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (5) , 1296-1309
A Globalized Model for Mapping Wearable Seismocardiogram Signals to Whole-Body Ballistocardiogram Signals Based on Deep Learning
The ballistocardiography (BCG) signal is a measurement of the vibrations of the center of mass of the body due to the cardiac cycle and can be used for noninvasive hemodynamic monitoring. The seismocardiography (SCG) signals measure the local vibrations of the chest wall due to the cardiac cycle. While BCG is a more well known modality, it requires the use of a modified bathroom scale or a force plate and cannot be measured in a wearable setting, whereas SCG signals can be measured using wearable accelerometers placed on the sternum. In this work we explore the idea of finding a mapping between zero mean and unit $\ell_2$ -norm SCG and BCG signal segments such that, the BCG signal can be acquired using wearable accelerometers (without retaining amplitude information). We use neural networks to find such a mapping and make use of the recently introduced UNet architecture. We trained our models on 26 healthy subjects and tested them on 10 subjects. Our results show that we can estimate the aforementioned segments of the BCG signal with a median Pearson correlation coefficient of 0.71 and a median absolute deviation (MAD) of 0.17. Furthermore, our model can estimate the R-I, R-J and R-K timing intervals with median absolute errors (and MAD) of 10.00 (8.90), 6.00 (5.93) and 8.00 (5.93), respectively. We show that using all three axis of the SCG accelerometer produces the best results while the head-to-foot SCG signal produces the best results when a single SCG axis is used.- 26 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (4) , 1080-1092
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
The seismocardiogram (SCG) is a noninvasively-obtained cardiovascular bio-signal that has gained traction in recent years, however is limited by its susceptibility to noise and motion artifacts. Because of this, signal quality must be assured before data are used to inform clinical care. Common methods of signal quality assurance include signal classification or assignment of a numerical quality index. Such tasks are difficult with SCG because there is no accepted standard for signal morphology. In this paper, we propose a unified method of quality indexing and classification that uses multi-subject-based methods to overcome this challenge. Dynamic-time feature matching is introduced as a novel method of obtaining the distance between a signal and reference template, with this metric, the signal quality index (SQI) is defined as a function of the inverse distance between the SCG and a large set of template signals. We demonstrate that this method is able to stratify SCG signals on held-out subjects based on their level of motion-artifact corruption. This method is extended, using the SQI as a feature for classification by ensembled quadratic discriminant analysis. Classification is validated by demonstrating, for the first time, both detection and localization of SCG sensor misplacement, achieving an F1 score of 0.83 on held-out subjects. This paper may provide a necessary step toward automating the analysis of SCG signals, addressing many of the key limitations and concerns precluding the method from being widely used in clinical and physiological sensing applications.
- 26 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (4) , 1080-1092
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
The seismocardiogram (SCG) is a noninvasively-obtained cardiovascular bio-signal that has gained traction in recent years, however is limited by its susceptibility to noise and motion artifacts. Because of this, signal quality must be assured before data are used to inform clinical care. Common methods of signal quality assurance include signal classification or assignment of a numerical quality index. Such tasks are difficult with SCG because there is no accepted standard for signal morphology. In this paper, we propose a unified method of quality indexing and classification that uses multi-subject-based methods to overcome this challenge. Dynamic-time feature matching is introduced as a novel method of obtaining the distance between a signal and reference template, with this metric, the signal quality index (SQI) is defined as a function of the inverse distance between the SCG and a large set of template signals. We demonstrate that this method is able to stratify SCG signals on held-out subjects based on their level of motion-artifact corruption. This method is extended, using the SQI as a feature for classification by ensembled quadratic discriminant analysis. Classification is validated by demonstrating, for the first time, both detection and localization of SCG sensor misplacement, achieving an F1 score of 0.83 on held-out subjects. This paper may provide a necessary step toward automating the analysis of SCG signals, addressing many of the key limitations and concerns precluding the method from being widely used in clinical and physiological sensing applications.
- 10 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (4) , 1019-1029
Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy
Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. Results: We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). Conclusion: The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. Significance: This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.
- 10 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (4) , 1019-1029
Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy
Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. Results: We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). Conclusion: The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. Significance: This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.
- 17 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (20) , 9324-9331
A Deep Neural Network-Based Permanent Magnet Localization for Tongue Tracking
- 17 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (20) , 9324-9331
A Deep Neural Network-Based Permanent Magnet Localization for Tongue Tracking
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8522-8531
Fusing Near-Infrared Spectroscopy With Wearable Hemodynamic Measurements Improves Classification of Mental Stress
Human-computer interaction technology, and the automatic classification of a person's mental state, are of interest to multiple industries. In this paper, the fusion of sensing modalities that monitor the oxygenation of the human prefrontal cortex (PFC) and cardiovascular physiology was evaluated to differentiate between rest, mental arithmetic, and N-back memory tasks. A flexible headband to measure near-infrared spectroscopy (NIRS) for quantifying PFC oxygenation, and forehead photo-plethysmography for assessing peripheral cardiovascular activity was designed. Physiological signals such as the electrocardiogram and seismocardiogram were collected, along with the measurements obtained using the headband. The setup was tested and validated with a total of 16 human subjects performing a series of arithmetic and N-back memory tasks. Features extracted were related to cardiac and peripheral sympathetic activity, vasomotor tone, pulse wave propagation, and oxygenation. Machine learning techniques were utilized to classify rest, arithmetic, and N-back tasks, using leave-one-subject-out cross validation. Macro-averaged accuracy of 85%, precision of 84%, recall rate of 83%, and F1 score of 80% were obtained from the classification of the three states. Statistical analyses on the subject-based results demonstrate that the fusion of NIRS and peripheral cardiovascular sensing significantly improves the accuracy, precision, recall, and F1 scores, compared to using NIRS sensing alone. Moreover, the fusion significantly improves the precision compared to peripheral cardiovascular sensing alone. The results of this paper can be used in the future to design a multi-modal wearable sensing system for classifying mental state for applications such as acute stress detection.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8522-8531
Fusing Near-Infrared Spectroscopy With Wearable Hemodynamic Measurements Improves Classification of Mental Stress
Human-computer interaction technology, and the automatic classification of a person's mental state, are of interest to multiple industries. In this paper, the fusion of sensing modalities that monitor the oxygenation of the human prefrontal cortex (PFC) and cardiovascular physiology was evaluated to differentiate between rest, mental arithmetic, and N-back memory tasks. A flexible headband to measure near-infrared spectroscopy (NIRS) for quantifying PFC oxygenation, and forehead photo-plethysmography for assessing peripheral cardiovascular activity was designed. Physiological signals such as the electrocardiogram and seismocardiogram were collected, along with the measurements obtained using the headband. The setup was tested and validated with a total of 16 human subjects performing a series of arithmetic and N-back memory tasks. Features extracted were related to cardiac and peripheral sympathetic activity, vasomotor tone, pulse wave propagation, and oxygenation. Machine learning techniques were utilized to classify rest, arithmetic, and N-back tasks, using leave-one-subject-out cross validation. Macro-averaged accuracy of 85%, precision of 84%, recall rate of 83%, and F1 score of 80% were obtained from the classification of the three states. Statistical analyses on the subject-based results demonstrate that the fusion of NIRS and peripheral cardiovascular sensing significantly improves the accuracy, precision, recall, and F1 scores, compared to using NIRS sensing alone. Moreover, the fusion significantly improves the precision compared to peripheral cardiovascular sensing alone. The results of this paper can be used in the future to design a multi-modal wearable sensing system for classifying mental state for applications such as acute stress detection.