Mariya Petrova Bivolarova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mariya Petrova Bivolarova has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Arsen Krikor Melikov
Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark
10 shared publications - Mizuho Akimoto
Advanced Collaborative Research Organization for Smart Society (ACROSS), Waseda University
4 shared publications - Pawel Wargocki
Technical University of Denmark
4 shared publications - Xiaojun Fan
Berkeley Education Alliance for Research in Singapore
4 shared publications - Chandra Sekhar
Department of the Built Environment, National University of Singapore, Singapore
3 shared publications - Chenxi Liao
Research Group Building Physics, Construction, and Climate Control, Department of Architecture and Urban Planning, Ghent University, Belgium
3 shared publications
Latest Publications
- Open Access
- 20 June 2025
- Published by Elsevier in Building and Environment
- Vol. 282
Performance of a prototype of the push-pull type personalized air curtain (PPAC) aimed to reduce respiratory infection risks
- 20 June 2025
- Published by Elsevier in Building and Environment
- Vol. 282
Open AccessPerformance of a prototype of the push-pull type personalized air curtain (PPAC) aimed to reduce respiratory infection risks
- Open Access
- 6 June 2025
- Published by Elsevier in Building and Environment
- Vol. 282
Definition and performance of acoustic personalised environmental control systems (acoustic PECS): A systematic review
- 6 June 2025
- Published by Elsevier in Building and Environment
- Vol. 282
Open AccessDefinition and performance of acoustic personalised environmental control systems (acoustic PECS): A systematic review
- Open Access
- 26 April 2025
- Published by Elsevier in Building and Environment
- Vol. 279
Effect of bedding on total thermal insulation in different sleeping postures measured with thermal manikin and modelled with JOS-3
- 26 April 2025
- Published by Elsevier in Building and Environment
- Vol. 279
Open AccessEffect of bedding on total thermal insulation in different sleeping postures measured with thermal manikin and modelled with JOS-3
- Open Access
- 28 September 2022
- Published by Elsevier in Building and Environment
- Vol. 225, 109630
A field intervention study of the effects of window and door opening on bedroom IAQ, sleep quality, and next-day cognitive performance
- 28 September 2022
- Published by Elsevier in Building and Environment
- Vol. 225, 109630
Open AccessA field intervention study of the effects of window and door opening on bedroom IAQ, sleep quality, and next-day cognitive performance
- 2 September 2022
- Published by Elsevier in Building and Environment
- Vol. 224
A cross-sectional field study of bedroom ventilation and sleep quality in Denmark during the heating season
- 2 September 2022
- Published by Elsevier in Building and Environment
- Vol. 224
A cross-sectional field study of bedroom ventilation and sleep quality in Denmark during the heating season
- 8 February 2022
- Published by Elsevier in Building and Environment
- Vol. 213
Towards enabling accurate measurements of CO2 exposure indoors
- 8 February 2022
- Published by Elsevier in Building and Environment
- Vol. 213
Towards enabling accurate measurements of CO2 exposure indoors
- Open Access
- 1 February 2022
- Published by Elsevier in Building and Environment
- Vol. 209
The effects of ventilation and temperature on sleep quality and next-day work performance: pilot measurements in a climate chamber
- 1 February 2022
- Published by Elsevier in Building and Environment
- Vol. 209
Open AccessThe effects of ventilation and temperature on sleep quality and next-day work performance: pilot measurements in a climate chamber
- 1 December 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 798, 149209
A survey of bedroom ventilation types and the subjective sleep quality associated with them in Danish housing
- 1 December 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 798, 149209
A survey of bedroom ventilation types and the subjective sleep quality associated with them in Danish housing
- Open Access
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Passive control of the bed micro-environment by using naturally ventilated mattress
Proper sleep is of a big importance considering that people spend one third of their lives sleeping. Thermal conditions and indoor air quality have an impact on sleep and thus must be optimized and controlled to enhance sleep quality. However, changing the thermal environment in the whole bedroom is not efficient, because of unnecessary use of energy and slow response of the HVAC system. Control of the bed microclimate is a quick and efficient way to obtain optimal conditions. Passive methods of control may, in a simple and inexpensive way, create comfortable and beneficial conditions for sleep. The performance of a porous mattress from highly-breathable material was investigated to validate the hypothesis that the natural ventilation it generates improves thermal and humidity conditions in bed. A simple method using a wet cloth was used to simulate sweating on the surface of a thermal manikin resembling a person in bed. The results showed promising effect of the breathable material on improving thermal and humidity conditions in bed, especially when it was used without textile cover. However, the mattress together with its original textile cover did not provide any significant ventilation effect, neither on humidity conditions in the bed, nor on cooling of the manikin’s body.
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Open AccessPassive control of the bed micro-environment by using naturally ventilated mattress
Proper sleep is of a big importance considering that people spend one third of their lives sleeping. Thermal conditions and indoor air quality have an impact on sleep and thus must be optimized and controlled to enhance sleep quality. However, changing the thermal environment in the whole bedroom is not efficient, because of unnecessary use of energy and slow response of the HVAC system. Control of the bed microclimate is a quick and efficient way to obtain optimal conditions. Passive methods of control may, in a simple and inexpensive way, create comfortable and beneficial conditions for sleep. The performance of a porous mattress from highly-breathable material was investigated to validate the hypothesis that the natural ventilation it generates improves thermal and humidity conditions in bed. A simple method using a wet cloth was used to simulate sweating on the surface of a thermal manikin resembling a person in bed. The results showed promising effect of the breathable material on improving thermal and humidity conditions in bed, especially when it was used without textile cover. However, the mattress together with its original textile cover did not provide any significant ventilation effect, neither on humidity conditions in the bed, nor on cooling of the manikin’s body.
- Open Access
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Impact of room airflow interaction on metabolic CO2 exposure
CFD simulations were performed to investigate occupants’ exposure to metabolic CO2 in a room with mechanical ventilation. A meeting room occupied by six adult people performing sedentary activity was simulated. Five of the six occupants were simulated to exhale air with realistic CO2 content, while one occupant was inhaling, i.e. the exposed occupant. Both exhalation and inhalation were simulated with constant flow rates. Two air distribution patterns were considered, mixing and displacement air distribution, each was combined with chilled ceiling, as summer conditions were simulated. For both air distribution patterns, the influence of solar gain of 200 W, which was simulated as heated vertical surface (window), and the distance between the occupants facing each other were studied. The simulation results revealed the importance of buoyancy flows generated by heated vertical surfaces for the pollution distribution. It was found out that compared to the case without solar heat gain, the presence of solar gain increased the inhaled CO2 level by 26.9 % in the case of displacement ventilation, while it reduced the exposure by 4.5 % when the outdoor air was distributed by mixing ventilation. The distance between the occupants facing each other did not affect considerably the exposure.
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Open AccessImpact of room airflow interaction on metabolic CO2 exposure
CFD simulations were performed to investigate occupants’ exposure to metabolic CO2 in a room with mechanical ventilation. A meeting room occupied by six adult people performing sedentary activity was simulated. Five of the six occupants were simulated to exhale air with realistic CO2 content, while one occupant was inhaling, i.e. the exposed occupant. Both exhalation and inhalation were simulated with constant flow rates. Two air distribution patterns were considered, mixing and displacement air distribution, each was combined with chilled ceiling, as summer conditions were simulated. For both air distribution patterns, the influence of solar gain of 200 W, which was simulated as heated vertical surface (window), and the distance between the occupants facing each other were studied. The simulation results revealed the importance of buoyancy flows generated by heated vertical surfaces for the pollution distribution. It was found out that compared to the case without solar heat gain, the presence of solar gain increased the inhaled CO2 level by 26.9 % in the case of displacement ventilation, while it reduced the exposure by 4.5 % when the outdoor air was distributed by mixing ventilation. The distance between the occupants facing each other did not affect considerably the exposure.