Nadine Spahr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nadine Spahr has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Schenk
Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
2 shared publications Nasreddin Abolmaali
Department of Radiology, Städtisches Klinikum Dresden, Dresden, Germany
1 shared publication- Nasreddin Abolmaali
Department of Radiology, Städtisches Klinikum Dresden-Friedrichstadt, Friedrichstraße 41, Dresden, 01067, Germany
1 shared publication - Philipp Schilling
Ressort TuW, Abt. MIT, FB Strahlenphysik, Städtisches Klinikum Dresden-Friedrichstadt, Friedrichstraße 41, Dresden, 01067, Germany
1 shared publication Ron Kikinis
Fraunhofer Institute for Medical Image Computing, MEVIS, Lübeck, Germany
1 shared publicationSmita Thoduka
Department of Radiology, Städtisches Klinikum Dresden, Dresden, Germany
1 shared publication
Latest Publications
- Open Access
- 22 October 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (2) , 215-225
Multimodal image registration for liver radioembolization planning and patient assessment
Purpose Multimodal imaging plays a key role in patient assessment and treatment planning in liver radioembolization. It will reach its full potential for convenient use in combination with deformable image registration methods. A registration framework is proposed for multimodal liver image registration of multi-phase CT, contrast-enhanced late-phase T1, T2, and DWI MRI sequences. Methods A chain of four pair-wise image registrations based on a variational registration framework using normalized gradient fields as distance measure and curvature regularization is introduced. A total of 103 cases of 35 patients was evaluated based on anatomical landmarks and deformation characteristics. Results Good anatomical correspondence and physical plausibility of the deformation fields were attained. The global mean landmark errors vary from 3.20 to 5.36 mm, strongly influenced by low resolved images in z-direction. Moderate volume changes are indicated by mean minimum and maximum Jacobian determinants of 0.44 up to 1.88. No deformation foldings were detected. The mean average divergence of the deformation fields range from 0.08 to 0.16 and the mean harmonic energies vary from 0.08 to 0.58. Conclusion The proposed registration solutions enable the combined use of information from multimodal imaging and provide an excellent basis for patient assessment and primary planning for liver radioembolization.
- 22 October 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (2) , 215-225
Open AccessMultimodal image registration for liver radioembolization planning and patient assessment
Purpose Multimodal imaging plays a key role in patient assessment and treatment planning in liver radioembolization. It will reach its full potential for convenient use in combination with deformable image registration methods. A registration framework is proposed for multimodal liver image registration of multi-phase CT, contrast-enhanced late-phase T1, T2, and DWI MRI sequences. Methods A chain of four pair-wise image registrations based on a variational registration framework using normalized gradient fields as distance measure and curvature regularization is introduced. A total of 103 cases of 35 patients was evaluated based on anatomical landmarks and deformation characteristics. Results Good anatomical correspondence and physical plausibility of the deformation fields were attained. The global mean landmark errors vary from 3.20 to 5.36 mm, strongly influenced by low resolved images in z-direction. Moderate volume changes are indicated by mean minimum and maximum Jacobian determinants of 0.44 up to 1.88. No deformation foldings were detected. The mean average divergence of the deformation fields range from 0.08 to 0.16 and the mean harmonic energies vary from 0.08 to 0.58. Conclusion The proposed registration solutions enable the combined use of information from multimodal imaging and provide an excellent basis for patient assessment and primary planning for liver radioembolization.
- Open Access
- 31 October 2017
- Published by Springer Nature in EJNMMI Physics
- Vol. 4 (1) , 25
Predictive SIRT dosimetry based on a territorial model
In the planning of selective internal radiation therapy (SIRT) for liver cancer treatment, one major aspect is to determine the prescribed activity and to estimate the resulting absorbed dose inside normal liver and tumor tissue. An optimized partition model for SIRT dosimetry based on arterial liver territories is proposed. This model is dedicated to characterize the variability of dose within the whole liver. For an arbitrary partition, the generalized absorbed dose is derived from the classical partition model. This enables to consider normal liver partitions for each arterial perfusion supply area and one partition for each tumor for activity and dose calculation. The proposed method excludes a margin of 11 mm emitting range around tumor volumes from normal liver to investigate the impact on activity calculation. Activity and dose calculation was performed for five patients using the body-surface-area (BSA) method, the classical and territorial partition model. The territorial model reaches smaller normal liver doses and significant higher tumor doses compared to the classical partition model. The exclusion of a small region around tumors has a significant impact on mean liver dose. Determined tumor activities for the proposed method are higher in all patients when limited by normal liver dose. Activity calculation based on BSA achieves in all cases the lowest amount. The territorial model provides a more local and patient-individual dose distribution in normal liver taking into account arterial supply areas. This proposed arterial liver territory-based partition model may be used for SPECT-independent activity calculation and dose prediction under the condition of an artery-based simulation for particle distribution.
- 31 October 2017
- Published by Springer Nature in EJNMMI Physics
- Vol. 4 (1) , 25
Open AccessPredictive SIRT dosimetry based on a territorial model
In the planning of selective internal radiation therapy (SIRT) for liver cancer treatment, one major aspect is to determine the prescribed activity and to estimate the resulting absorbed dose inside normal liver and tumor tissue. An optimized partition model for SIRT dosimetry based on arterial liver territories is proposed. This model is dedicated to characterize the variability of dose within the whole liver. For an arbitrary partition, the generalized absorbed dose is derived from the classical partition model. This enables to consider normal liver partitions for each arterial perfusion supply area and one partition for each tumor for activity and dose calculation. The proposed method excludes a margin of 11 mm emitting range around tumor volumes from normal liver to investigate the impact on activity calculation. Activity and dose calculation was performed for five patients using the body-surface-area (BSA) method, the classical and territorial partition model. The territorial model reaches smaller normal liver doses and significant higher tumor doses compared to the classical partition model. The exclusion of a small region around tumors has a significant impact on mean liver dose. Determined tumor activities for the proposed method are higher in all patients when limited by normal liver dose. Activity calculation based on BSA achieves in all cases the lowest amount. The territorial model provides a more local and patient-individual dose distribution in normal liver taking into account arterial supply areas. This proposed arterial liver territory-based partition model may be used for SPECT-independent activity calculation and dose prediction under the condition of an artery-based simulation for particle distribution.