Francisco Garc&bldjia Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francisco Garc&bldjia Sánchez has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
- Aurora. Navas Diaz
Department of Analytical Chemistry, Faculty of Sciences, University of Málaga, Málaga, Spain
34 shared publications - Manuel Algarra
INAMAT2-Institute for Advanced Materials and Mathematics, Department of Science, Public University of Navarra, Campus of Arrosadía, 31006 Pamplona, Spain
16 shared publications - Jose Javier Laserna
UMALaserLab, Departamento de Química Analítica, Universidad de Málaga, Jiménez Fraud 4, 29010, Málaga, Spain
13 shared publications A. Navas
10 shared publicationsA. Navas Díaz
Department of Analytical Chemistry, Faculty of Sciences University of Malaga 2071‐Malaga Spain
9 shared publicationsAlfonso Aguilar
Department of Analytical Chemistry, Faculty of Science , University of Malaga , Malaga , Spain
8 shared publications
Latest Publications
- 1 February 2017
- Published by Elsevier in Chemosphere
- Vol. 168, 903-907
Enantiomeric fraction of styrene glycol as a biomarker of occupational risk exposure to styrene
- 1 February 2017
- Published by Elsevier in Chemosphere
- Vol. 168, 903-907
Enantiomeric fraction of styrene glycol as a biomarker of occupational risk exposure to styrene
- 3 January 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (10) , 1568-1579
Determination of Aristocularine Enantiomers by Dispersive Liquid–Liquid Microextraction and Chiral High-performance Liquid Chromatography
Here is reported a novel analytical approach for the extractive separation and determination of enantiomeric ratios of aristocularine in bovine serum albumin. The results demonstrate suitable analytical performances. The separation was performed by chiral high-performance liquid chromatography with a 5-µm column using a mobile phase of 1:1 n-hexane:ethanol at a flow rate of 0.7 mL min−1 with ultraviolet–visible absorption, circular dichroism, and polarimetric detection. The enantiomers were eluted at 13.2 and 15.6 min for (+) and (−)-aristocularine, with a resolution of 1.58 and a separation factor of 1.27. The analytical parameters for the dispersive liquid–liquid microextraction were optimized; under these conditions, the extraction recoveries were from 88.6% to 93.9% for a two-step extraction. The precision, reported as the percent relative standard deviation, had values from 2.9% to 3.2% for 0.5 µg mL−1 of analyte for five replicate measurements using ultraviolet–visible absorption and circular dichroism detection. The limits of detection were between 0.05 and 0.08 µg mL−1 with enrichment ratios up to a value of 12.
- 3 January 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 50 (10) , 1568-1579
Determination of Aristocularine Enantiomers by Dispersive Liquid–Liquid Microextraction and Chiral High-performance Liquid Chromatography
Here is reported a novel analytical approach for the extractive separation and determination of enantiomeric ratios of aristocularine in bovine serum albumin. The results demonstrate suitable analytical performances. The separation was performed by chiral high-performance liquid chromatography with a 5-µm column using a mobile phase of 1:1 n-hexane:ethanol at a flow rate of 0.7 mL min−1 with ultraviolet–visible absorption, circular dichroism, and polarimetric detection. The enantiomers were eluted at 13.2 and 15.6 min for (+) and (−)-aristocularine, with a resolution of 1.58 and a separation factor of 1.27. The analytical parameters for the dispersive liquid–liquid microextraction were optimized; under these conditions, the extraction recoveries were from 88.6% to 93.9% for a two-step extraction. The precision, reported as the percent relative standard deviation, had values from 2.9% to 3.2% for 0.5 µg mL−1 of analyte for five replicate measurements using ultraviolet–visible absorption and circular dichroism detection. The limits of detection were between 0.05 and 0.08 µg mL−1 with enrichment ratios up to a value of 12.
- 1 September 2015
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 42, 187-192
Fast stopped-flow enzymatic sensing of fenitrothion in grapes and orange juice
- 1 September 2015
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 42, 187-192
Fast stopped-flow enzymatic sensing of fenitrothion in grapes and orange juice
- Open Access
- 1 July 2015
- Published by Elsevier in Food Chemistry
- Vol. 178, 179-185
Enantioseparation of the fungicide imazalil in orange juice by chiral HPLC. Study on degradation rates and extractive/enrichment techniques
- 1 July 2015
- Published by Elsevier in Food Chemistry
- Vol. 178, 179-185
Open AccessEnantioseparation of the fungicide imazalil in orange juice by chiral HPLC. Study on degradation rates and extractive/enrichment techniques
- 3 February 2015
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (7) , 481-486
Time-Resolved Spectroscopy for Selective Determination of Fluorescent Diuretics
- 3 February 2015
- Published by Taylor & Francis in Spectroscopy Letters
- Vol. 48 (7) , 481-486
Time-Resolved Spectroscopy for Selective Determination of Fluorescent Diuretics
- 2 August 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (15) , 1863-1868
HPLC enantioseparation of alkaloid malacitanine using fluorimetric/polarimetric detection
This work reports two methods developed for the separation and determination of the enantiomers of the new alkaloid malacitanine (MLC) and the determination of the enantiomeric purity in mixtures. First, the isomers were separated using a Chirex 3020 (250 mm × 4.6 mm, 5 μm) chiral column with a mobile phase of cyclohexane–1,2‐dichloroethane–ethanol–trifluoroacetic acid (64:30:6:0.6, v/v/v/v) at a flow rate of 1 mL/min and fluorimetric detection. Obtained retention times were 12.4 and 15.9 min (+ and −) with a resolution Rs of 1.13. Relative standard deviations (RSDs) were 2.5 and 2.4% at the 0.5‐μg level (four determinations). Second, a nonenantioselective procedure for the determination of enantiomeric purity of MLC using a Lichrospher ® Si‐60 (250 mm × 5 mm, 5 μm) normal phase with a mobile phase of 100% ethanol at a flow rate of 0.9 mL/min coupled to two detectors in series, fluorimetric and polarimetric. RSD of 3.3% was obtained. Calculated enantiomeric purity by chiral chromatography gave 48.6% (−)‐MLC in the near racemic product. Using polarimetric signal of the nonseparated enantiomers and comparing the slopes of the calibration curves (enantiomers) from the racemic product gave 47.8% (−)‐MLC content. A study of accuracy of (−)‐MLC gave recoveries from 98.3 to 100.7%.
- 2 August 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (15) , 1863-1868
HPLC enantioseparation of alkaloid malacitanine using fluorimetric/polarimetric detection
This work reports two methods developed for the separation and determination of the enantiomers of the new alkaloid malacitanine (MLC) and the determination of the enantiomeric purity in mixtures. First, the isomers were separated using a Chirex 3020 (250 mm × 4.6 mm, 5 μm) chiral column with a mobile phase of cyclohexane–1,2‐dichloroethane–ethanol–trifluoroacetic acid (64:30:6:0.6, v/v/v/v) at a flow rate of 1 mL/min and fluorimetric detection. Obtained retention times were 12.4 and 15.9 min (+ and −) with a resolution Rs of 1.13. Relative standard deviations (RSDs) were 2.5 and 2.4% at the 0.5‐μg level (four determinations). Second, a nonenantioselective procedure for the determination of enantiomeric purity of MLC using a Lichrospher ® Si‐60 (250 mm × 5 mm, 5 μm) normal phase with a mobile phase of 100% ethanol at a flow rate of 0.9 mL/min coupled to two detectors in series, fluorimetric and polarimetric. RSD of 3.3% was obtained. Calculated enantiomeric purity by chiral chromatography gave 48.6% (−)‐MLC in the near racemic product. Using polarimetric signal of the nonseparated enantiomers and comparing the slopes of the calibration curves (enantiomers) from the racemic product gave 47.8% (−)‐MLC content. A study of accuracy of (−)‐MLC gave recoveries from 98.3 to 100.7%.
- 7 February 2012
- Published by Wiley in Biomedical Chromatography
- Vol. 26 (10) , 1241-1246
Determination of enantiomeric excess by chiral liquid chromatography without enantiomerically pure starting standards
A facile approach for the enantiomeric excess determination of enantiomeric mixtures without the necessity of pure enantiomer standards is presented. Promethazine and trimeprazine commercial nonracemic mixtures were used as cases study to probe the validity of the method. Chromatographic resolutions obtained with a chiral column AGP in reverse phase mode were 1.32–1.16 (promethazine) and 1.20–0.93 (trimeprazine) for the three detectors (circular dichroism, photometric and fluorimetric) in series. Results obtained showed that enantiomeric excess was 10.4, 8.71 and 8.58% for promethazine and 1.60, 1.23 and 1.80% for trimeprazine (medium values of 9.23 ± 1.01% and 1.54 ± 0.29%, respectively). Recovery assay over human serum samples, at three concentration levels, spiked with prometazine and submitted to solid‐phase extraction, gave values of 99.09–93.48% [S‐(−) enantiomer] and 98.51–91.89% [R‐(+)‐enantiomer]. Detection limits of promethazine enantiomers were between 0.02 µg (fluorimetric) and 1 µg (circular dichroism), and 0.02–1.1 µg for trimeprazine. Copyright © 2012 John Wiley & Sons, Ltd.
- 7 February 2012
- Published by Wiley in Biomedical Chromatography
- Vol. 26 (10) , 1241-1246
Determination of enantiomeric excess by chiral liquid chromatography without enantiomerically pure starting standards
A facile approach for the enantiomeric excess determination of enantiomeric mixtures without the necessity of pure enantiomer standards is presented. Promethazine and trimeprazine commercial nonracemic mixtures were used as cases study to probe the validity of the method. Chromatographic resolutions obtained with a chiral column AGP in reverse phase mode were 1.32–1.16 (promethazine) and 1.20–0.93 (trimeprazine) for the three detectors (circular dichroism, photometric and fluorimetric) in series. Results obtained showed that enantiomeric excess was 10.4, 8.71 and 8.58% for promethazine and 1.60, 1.23 and 1.80% for trimeprazine (medium values of 9.23 ± 1.01% and 1.54 ± 0.29%, respectively). Recovery assay over human serum samples, at three concentration levels, spiked with prometazine and submitted to solid‐phase extraction, gave values of 99.09–93.48% [S‐(−) enantiomer] and 98.51–91.89% [R‐(+)‐enantiomer]. Detection limits of promethazine enantiomers were between 0.02 µg (fluorimetric) and 1 µg (circular dichroism), and 0.02–1.1 µg for trimeprazine. Copyright © 2012 John Wiley & Sons, Ltd.
- 1 December 2011
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 83 (1) , 88-93
Time resolved spectroscopy of 2-(dimethylamine)fluorene. Solvent effects and photophysical behavior
- 1 December 2011
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 83 (1) , 88-93
Time resolved spectroscopy of 2-(dimethylamine)fluorene. Solvent effects and photophysical behavior