Atsushi Yamashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atsushi Yamashita has a total of 309 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Asama
The University of Tokyo
84 shared publications - Qi An
The University of Tokyo
33 shared publications Toru Kaneko
20 shared publications- Yusuke Tamura
Department of Robotics, Tohoku University, Sendai 980-8579, Japan
15 shared publications - Jun Younes Louhi Kasahara
Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan
13 shared publications - Yonghoon Ji
Graduate School of Advanced Science and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa 923-1292, Japan
10 shared publications
Latest Publications
- Open Access
- 27 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (47) , 475007
A high-precision measurement method for dynamic cable winding gaps in multi-layer winding winches based on machine vision
High-precision online detection of cable winding gaps in tethered balloon winches is critical to ensuring the safe and stable operation of tethered systems. To address perspective distortion caused by the cylindrical drum surface, spurious edge interference from cable twisted texture and insufficient measurement accuracy under dynamic multi-layer winding conditions, this paper proposes a vision-based cable gap measurement method combining multi-layer geometric modelling with local directional dispersion (LoDD) enhancement. A recursive projection model of wave-like curves for multi-layer cables is constructed, which compensates for perspective errors from curved-surface depth variations through layer-by-layer object-distance correction. A Devernay-LoDD sub-pixel edge detection algorithm is proposed, which jointly suppresses texture spurious edges using gradient peak confidence and geometric direction confidence. Combined with dynamic region-of-interest localisation, exponentially weighted guided filtering and RANSAC line fitting, a complete measurement pipeline is established. A visual detection system is built for experimental verification. The results show that the standard deviation for static repeated measurements is less than 0.004 mm, with a maximum absolute error of 0.0159 mm. Under the strong texture condition of the second layer, the mean absolute error is reduced by 56.4% compared with the traditional Devernay algorithm. Three-layer dynamic winding tests yield an average relative error of approximately 5.09%, with absolute errors below 0.10 mm for most measurement points. The geometric model has a layer-by-layer recursive property and can in principle be extended to more winding layers, meeting the demand for high-precision online detection of cable winding gaps in tethered balloon winches.
- 27 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (47) , 475007
Open AccessA high-precision measurement method for dynamic cable winding gaps in multi-layer winding winches based on machine vision
High-precision online detection of cable winding gaps in tethered balloon winches is critical to ensuring the safe and stable operation of tethered systems. To address perspective distortion caused by the cylindrical drum surface, spurious edge interference from cable twisted texture and insufficient measurement accuracy under dynamic multi-layer winding conditions, this paper proposes a vision-based cable gap measurement method combining multi-layer geometric modelling with local directional dispersion (LoDD) enhancement. A recursive projection model of wave-like curves for multi-layer cables is constructed, which compensates for perspective errors from curved-surface depth variations through layer-by-layer object-distance correction. A Devernay-LoDD sub-pixel edge detection algorithm is proposed, which jointly suppresses texture spurious edges using gradient peak confidence and geometric direction confidence. Combined with dynamic region-of-interest localisation, exponentially weighted guided filtering and RANSAC line fitting, a complete measurement pipeline is established. A visual detection system is built for experimental verification. The results show that the standard deviation for static repeated measurements is less than 0.004 mm, with a maximum absolute error of 0.0159 mm. Under the strong texture condition of the second layer, the mean absolute error is reduced by 56.4% compared with the traditional Devernay algorithm. Three-layer dynamic winding tests yield an average relative error of approximately 5.09%, with absolute errors below 0.10 mm for most measurement points. The geometric model has a layer-by-layer recursive property and can in principle be extended to more winding layers, meeting the demand for high-precision online detection of cable winding gaps in tethered balloon winches.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 13006-13007
Corrections to “CubeDVO: Cubemap-Spherical Deep Visual Odometry for a Monocular 360-Degree Camera”
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 13006-13007
Corrections to “CubeDVO: Cubemap-Spherical Deep Visual Odometry for a Monocular 360-Degree Camera”
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 12703-12710
SpatioDenoiser: Position-Guided Denoising via Spatial Audio Memory for Anomalous Sound Detection in Mobile Robots
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 12703-12710
SpatioDenoiser: Position-Guided Denoising via Spatial Audio Memory for Anomalous Sound Detection in Mobile Robots
- Open Access
- 22 October 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (5) , 056031
Bio-inspired open ligamentous knee joint with extended pitch and yaw range of motion
This study presents a bio-inspired open knee joint for biofidelic robots with an anatomically correct range of motion. Bio-inspired joints contribute to robot performance and understanding living organisms by providing dynamic motion data as the real-world physical twin. The proposed joint structure features the integration of the open joint and ligamentous constraint. In particular, the spherical envelope of the condyles contributes to the rotation other than pitch rotation. By applying a bio-inspired ligament arrangement, the developed knee joint performed pitch and yaw motion. The relationship between the ligament length and joint orientation was derived by forward kinematics and the ligament wrapping. The arrangement of the bio-inspired collateral ligaments was determined with the iterative calculation method considering the object wrapping, which predicted the yaw range of motion. Verification of the proposed approach includes the evaluation of the range of motion on the robotic knee joint equipped with the motor-driven tendons. The robot validation tests include the rotational motions around the pitch and yaw axes. The tests showed that the proposed joint structure can be a relevant approach for replicating the range of motion of a human knee joint. Future work includes the motion control of the joint system and integration into a real robot.
- 22 October 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (5) , 056031
Open AccessBio-inspired open ligamentous knee joint with extended pitch and yaw range of motion
This study presents a bio-inspired open knee joint for biofidelic robots with an anatomically correct range of motion. Bio-inspired joints contribute to robot performance and understanding living organisms by providing dynamic motion data as the real-world physical twin. The proposed joint structure features the integration of the open joint and ligamentous constraint. In particular, the spherical envelope of the condyles contributes to the rotation other than pitch rotation. By applying a bio-inspired ligament arrangement, the developed knee joint performed pitch and yaw motion. The relationship between the ligament length and joint orientation was derived by forward kinematics and the ligament wrapping. The arrangement of the bio-inspired collateral ligaments was determined with the iterative calculation method considering the object wrapping, which predicted the yaw range of motion. Verification of the proposed approach includes the evaluation of the range of motion on the robotic knee joint equipped with the motor-driven tendons. The robot validation tests include the rotational motions around the pitch and yaw axes. The tests showed that the proposed joint structure can be a relevant approach for replicating the range of motion of a human knee joint. Future work includes the motion control of the joint system and integration into a real robot.
- Open Access
- 7 October 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (5) , 056013
Dislocation analysis on bio-inspired open hip joint with active-and-passive stabilizers
This study presents a simulator framework to replicate joint dislocation that can be used to evaluate the contributions of various joint stabilizers. Compared to conventional axial joint configurations, biologically inspired open joints allow for a large range of motion with fewer rotational components and no singularities. Despite these advantages, open joints have few practical applications due to joint dislocation. To facilitate the development of bio-inspired open joints, our study evaluates the performance of biomimetic joint stabilizers involving (1) the muscle actuators as the active stabilizer, and (2) the skeletal socket and the ligaments as the passive stabilizers. Those stabilizers exert appropriate constraint forces during joint motion to prevent dislocation. The convex decomposition of the skeletal socket enabled the simulation of the dislocation behavior. The kinematic simulation determines the ligaments’ maximum length depending on the desired joint motion. The designed ligaments were suggested to prevent excessive dislocation in the simulation even when the motor output was off. The comparative simulation analysis also indicated that socket depth, active stabilizer, and passive stabilizer had different contributions for dislocation prevention and recovery. Future work includes the experimental verification of the proposed open hip joint architecture.
- 7 October 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (5) , 056013
Open AccessDislocation analysis on bio-inspired open hip joint with active-and-passive stabilizers
This study presents a simulator framework to replicate joint dislocation that can be used to evaluate the contributions of various joint stabilizers. Compared to conventional axial joint configurations, biologically inspired open joints allow for a large range of motion with fewer rotational components and no singularities. Despite these advantages, open joints have few practical applications due to joint dislocation. To facilitate the development of bio-inspired open joints, our study evaluates the performance of biomimetic joint stabilizers involving (1) the muscle actuators as the active stabilizer, and (2) the skeletal socket and the ligaments as the passive stabilizers. Those stabilizers exert appropriate constraint forces during joint motion to prevent dislocation. The convex decomposition of the skeletal socket enabled the simulation of the dislocation behavior. The kinematic simulation determines the ligaments’ maximum length depending on the desired joint motion. The designed ligaments were suggested to prevent excessive dislocation in the simulation even when the motor output was off. The comparative simulation analysis also indicated that socket depth, active stabilizer, and passive stabilizer had different contributions for dislocation prevention and recovery. Future work includes the experimental verification of the proposed open hip joint architecture.
- Open Access
Learning Selective Acoustic Signaling for Social Robot Navigation in Heterogeneous Crowds
Active acoustic signaling can improve robot navigation in crowds, but methods based on a cooperative-response assumption may generate unnecessary signals near static pedestrians and misjudge signaling effectiveness when non-cooperative pedestrians approach. This study proposes heterogeneous interactive crowd navigation with acoustic signaling, a selective acoustic-signaling method for heterogeneous crowds. The proposed method models dynamic cooperative pedestrians, static non-responsive pedestrians, and approaching non-cooperative chasers. A differentiated reinforcement-learning social reward suppresses ineffective signaling in static-only neighborhoods, while a second training stage introduces non-cooperative chasers controlled by a standard optimal reciprocal collision avoidance policy with fixed parameters to improve motion avoidance when signaling cannot alter chaser motion. Experiments in corridor and square-hall environments used 500 test episodes per setting. The differentiated reward reduced total signaling rates by 41.2% and 47.0%, respectively, and reduced static-condition signaling rates to 0%, while largely preserving dynamic-condition signaling and navigation time. In complete heterogeneous scenarios, the proposed method achieved success rates of 0.94 and 0.91, collision rates of 0.02 and 0.04, and catch rates of 0.08 and 0.12. These results indicate improved signaling selectivity and navigation performance under the evaluated controlled simulation conditions involving predefined cooperative and non-responsive pedestrian behaviors.
Open AccessLearning Selective Acoustic Signaling for Social Robot Navigation in Heterogeneous Crowds
Active acoustic signaling can improve robot navigation in crowds, but methods based on a cooperative-response assumption may generate unnecessary signals near static pedestrians and misjudge signaling effectiveness when non-cooperative pedestrians approach. This study proposes heterogeneous interactive crowd navigation with acoustic signaling, a selective acoustic-signaling method for heterogeneous crowds. The proposed method models dynamic cooperative pedestrians, static non-responsive pedestrians, and approaching non-cooperative chasers. A differentiated reinforcement-learning social reward suppresses ineffective signaling in static-only neighborhoods, while a second training stage introduces non-cooperative chasers controlled by a standard optimal reciprocal collision avoidance policy with fixed parameters to improve motion avoidance when signaling cannot alter chaser motion. Experiments in corridor and square-hall environments used 500 test episodes per setting. The differentiated reward reduced total signaling rates by 41.2% and 47.0%, respectively, and reduced static-condition signaling rates to 0%, while largely preserving dynamic-condition signaling and navigation time. In complete heterogeneous scenarios, the proposed method achieved success rates of 0.94 and 0.91, collision rates of 0.02 and 0.04, and catch rates of 0.08 and 0.12. These results indicate improved signaling selectivity and navigation performance under the evaluated controlled simulation conditions involving predefined cooperative and non-responsive pedestrian behaviors.
- Open Access
- 5 September 2026
- Published by Fuji Technology Press Ltd. in International Journal of Automation Technology
- Vol. 20 (5) , 491-502
Moving Object Detection from Moving Camera Using Focus of Expansion Likelihood and Segmentation
Separating moving and static objects from a moving camera viewpoint is essential for 3D reconstruction, autonomous navigation, and scene understanding in robotics. Existing approaches often rely primarily on optical flow, which struggles to detect moving objects in complex, structured scenes involving camera motion. To address this limitation, we propose Focus of Expansion Likelihood and Segmentation (FoELS), a method based on the core idea of integrating both optical flow and texture information. FoELS computes the focus of expansion (FoE) from optical flow and derives an initial motion likelihood from the outliers of the FoE computation. This likelihood is then fused with a segmentation-based prior to estimate the final moving probability. The method effectively handles challenges including complex structured scenes, rotational camera motion, and parallel motion. Comprehensive evaluations on the DAVIS 2016 and FBMS-59 datasets, along with real-world traffic videos including parallel, cross-direction, opposite-direction, and crowded scenes, demonstrate its effectiveness and state-of-the-art performance.
- 5 September 2026
- Published by Fuji Technology Press Ltd. in International Journal of Automation Technology
- Vol. 20 (5) , 491-502
Open AccessMoving Object Detection from Moving Camera Using Focus of Expansion Likelihood and Segmentation
Separating moving and static objects from a moving camera viewpoint is essential for 3D reconstruction, autonomous navigation, and scene understanding in robotics. Existing approaches often rely primarily on optical flow, which struggles to detect moving objects in complex, structured scenes involving camera motion. To address this limitation, we propose Focus of Expansion Likelihood and Segmentation (FoELS), a method based on the core idea of integrating both optical flow and texture information. FoELS computes the focus of expansion (FoE) from optical flow and derives an initial motion likelihood from the outliers of the FoE computation. This likelihood is then fused with a segmentation-based prior to estimate the final moving probability. The method effectively handles challenges including complex structured scenes, rotational camera motion, and parallel motion. Comprehensive evaluations on the DAVIS 2016 and FBMS-59 datasets, along with real-world traffic videos including parallel, cross-direction, opposite-direction, and crowded scenes, demonstrate its effectiveness and state-of-the-art performance.
- 2 September 2026
- Published by Springer Nature
- p. 359-370
Estimation of Radiation Source Distribution in High-Dose 3D Space Using Nondirectional Detector with Attenuation by Lightweight Shield
- 2 September 2026
- Published by Springer Nature
- p. 359-370
Estimation of Radiation Source Distribution in High-Dose 3D Space Using Nondirectional Detector with Attenuation by Lightweight Shield
- Open Access
- 24 August 2026
- Published by Springer Nature in Experimental Brain Research
- Vol. 244 (9) , 182
Levodopa-induced alterations in vertical center of mass and muscle synergy structure during Parkinsonian gait
Parkinson’s disease (PD) is a neurodegenerative disorder characterized by gait impairments that affect the regulation of whole-body movement, which can be quantified through metrics such as vertical center of mass (vCoM). In healthy gait, vCoM oscillations contribute to metabolic efficiency by facilitating the exchange between kinetic and potential energy; however, this mechanism is often disrupted in PD. Although levodopa improves motor impairments, its impact on vCoM and neuromuscular control remains poorly understood. This study investigated levodopa effects on vCoM and neuromuscular coordination in fifteen patients with PD (Hoehn & Yahr 2–3) during PD OFF (before levodopa) and PD ON (after levodopa) and compared to nine healthy older adults (HOA). Kinematic and electromyography data were collected during an overground walk to quantify vCoM and muscle synergies. Here we show that levodopa significantly increased maximum vCoM displacement (p = 0.002), with PD OFF showing significantly reduced displacement compared to HOA (p < 0.001) while PD ON did not differ significantly, indicating a shift in vCoM displacement towards healthy patterns. Temporal patterns of muscle synergies showed that PD OFF exhibited prolonged activation duration and slower slope-to-peak in Synergy 2 (push-off) compared to HOA while spatial patterns of Synergy 2 showed an increase in gastrocnemius muscle contribution in PD ON compared to PD OFF (p = 0.002). Together these findings demonstrate that levodopa might partially restore whole-body gait mechanics through a unique reorganization of muscle synergy structure, pointing to a possible functional link between neuromuscular coordination and gait dynamics in PD.
- 24 August 2026
- Published by Springer Nature in Experimental Brain Research
- Vol. 244 (9) , 182
Open AccessLevodopa-induced alterations in vertical center of mass and muscle synergy structure during Parkinsonian gait
Parkinson’s disease (PD) is a neurodegenerative disorder characterized by gait impairments that affect the regulation of whole-body movement, which can be quantified through metrics such as vertical center of mass (vCoM). In healthy gait, vCoM oscillations contribute to metabolic efficiency by facilitating the exchange between kinetic and potential energy; however, this mechanism is often disrupted in PD. Although levodopa improves motor impairments, its impact on vCoM and neuromuscular control remains poorly understood. This study investigated levodopa effects on vCoM and neuromuscular coordination in fifteen patients with PD (Hoehn & Yahr 2–3) during PD OFF (before levodopa) and PD ON (after levodopa) and compared to nine healthy older adults (HOA). Kinematic and electromyography data were collected during an overground walk to quantify vCoM and muscle synergies. Here we show that levodopa significantly increased maximum vCoM displacement (p = 0.002), with PD OFF showing significantly reduced displacement compared to HOA (p < 0.001) while PD ON did not differ significantly, indicating a shift in vCoM displacement towards healthy patterns. Temporal patterns of muscle synergies showed that PD OFF exhibited prolonged activation duration and slower slope-to-peak in Synergy 2 (push-off) compared to HOA while spatial patterns of Synergy 2 showed an increase in gastrocnemius muscle contribution in PD ON compared to PD OFF (p = 0.002). Together these findings demonstrate that levodopa might partially restore whole-body gait mechanics through a unique reorganization of muscle synergy structure, pointing to a possible functional link between neuromuscular coordination and gait dynamics in PD.
- 20 April 2026
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 38 (2) , 672-684
Soil-Adaptive Autonomous Excavation: Bulking Factor-Based Soil Density Estimation and Excavation Path Optimization with a Genetic Algorithm
In this study, we present a novel autonomous excavation method that achieves high efficiency under varying soil conditions. This method consists of two main steps, including first estimating the density of the soil and then generating an optimal excavation path based on the estimated density. The proposed method estimates soil density by taking advantage of the bulking phenomenon, which refers to an increase in the volume of excavated soil. This estimation relies solely on 3D point-cloud data obtained before and after excavation. Using the estimated soil density, an optimal excavation path is generated by applying a genetic algorithm in a physics simulator that replicates both the hydraulic excavator and the target ground. The algorithm explores a range of paths over multiple generations to find one that maximizes efficiency. The effectiveness of the proposed method was verified through simulations and field experiments. In particular, field experiments conducted in soft soil showed that the proposed method improved excavation efficiency by 27.7% compared with a baseline method using fixed parameters.
- 20 April 2026
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 38 (2) , 672-684
Soil-Adaptive Autonomous Excavation: Bulking Factor-Based Soil Density Estimation and Excavation Path Optimization with a Genetic Algorithm
In this study, we present a novel autonomous excavation method that achieves high efficiency under varying soil conditions. This method consists of two main steps, including first estimating the density of the soil and then generating an optimal excavation path based on the estimated density. The proposed method estimates soil density by taking advantage of the bulking phenomenon, which refers to an increase in the volume of excavated soil. This estimation relies solely on 3D point-cloud data obtained before and after excavation. Using the estimated soil density, an optimal excavation path is generated by applying a genetic algorithm in a physics simulator that replicates both the hydraulic excavator and the target ground. The algorithm explores a range of paths over multiple generations to find one that maximizes efficiency. The effectiveness of the proposed method was verified through simulations and field experiments. In particular, field experiments conducted in soft soil showed that the proposed method improved excavation efficiency by 27.7% compared with a baseline method using fixed parameters.