David Grunwald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Grunwald has a total of 398 co-authors. Here are the top co-authors by number of shared publications:
- Roland Nitschke
Signalling Research Centres CIBSS and BIOSS, University of Freiburg, Freiburg, Germany
12 shared publications - Glyn Nelson
Bioimaging Unit, Newcastle University, Newcastle upon Tyne, UK
11 shared publications - Caterina Strambio-De-Castillia
Program in Molecular Medicine, University of Massachusetts Chan Medical School, Worcester, USA
10 shared publications - Nathalie Gaudreault
Allen Institute for Cell Science, Seattle, USA
10 shared publications - Judith Lacoste
MIA Cellavie Inc. 29 , Montreal
8 shared publications - Mathias Hammer
RNA Therapeutics Institute, University of Massachusetts Chan Medical School 20 , Worcester, MA
8 shared publications
Latest Publications
- 25 February 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (3)
Better reporting is better science: Community-defined minimal reporting requirements for light microscopy
Incomplete reporting of microscopy methods undermines transparency, reproducibility, and data reuse. Despite recent initiatives, comprehensive, broadly endorsed, and accessible reporting guidelines are still lacking. Here, we present a bare minimal microscopy reporting requirements checklist that integrates human- and machine-readable input to provide clear, actionable guidance for researchers, reviewers, and publishers and to advance community standards in microscopy.
- 25 February 2026
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 225 (3)
Better reporting is better science: Community-defined minimal reporting requirements for light microscopy
Incomplete reporting of microscopy methods undermines transparency, reproducibility, and data reuse. Despite recent initiatives, comprehensive, broadly endorsed, and accessible reporting guidelines are still lacking. Here, we present a bare minimal microscopy reporting requirements checklist that integrates human- and machine-readable input to provide clear, actionable guidance for researchers, reviewers, and publishers and to advance community standards in microscopy.
- Open Access
High-throughput quantification of huntingtin mRNA expression and aggregation in mouse brain using automated RNAscope imaging
Huntington’s disease (HD) is a repeat-associated neurodegenerative disorder traditionally characterized by toxic protein pathology resulting from expanded CAG repeats in the huntingtin (HTT) gene. In recent years, however, studies have identified repeat expansion–driven RNA pathology as an additional and potentially independent contributor to disease. In particular, mutant HTT transcripts containing expanded CAG repeats accumulate in the nucleus and form discrete RNA clusters, a feature shared with several other repeat-associated disorders. While protein aggregation and its downstream consequences have been extensively studied, our current understanding of the composition, organization, and dynamics of these nuclear mRNA clusters remains limited. Progress in this area has been constrained in part by the lack of robust methods to detect and quantify expanded HTT transcripts at single-molecule resolution within intact tissue. As a result, the contribution of RNA clustering to disease mechanisms, its relationship to repeat length, and its interaction with other pathological features of HD remain poorly defined. Here we present a high-throughput RNAscope™ pipeline that combines automated confocal imaging with rigorous microscope characterization to quantify both single mRNA molecules and multi-transcript clusters in fixed mouse brain tissue. Using 3D Gaussian point-spread function (PSF) fitting calibrated on 200 nm fluorescent beads and pointilistic image features from tissue data, we establish per-slide intensity thresholds from negative controls and normalize experimental signals to single-molecule reference intensities. The critical validation of our approach operates at two scales: for single molecules, the linear relationship between spot size and intensity (r 2 > 0.90) reflects variable probe binding along transcripts; for clusters, the linear scaling between cluster volume and mRNA content (R 2 > 0.98) confirms uniform probe accessibility and enables quantitative conversion of fluorescence intensity to absolute mRNA counts. Applied to HttQ111+/− knock-in mice across multiple ages, we analyzed thousands of fields of view (FOVs), detecting >900,000 single mRNA molecules and segmenting >1.9 million mRNA clusters using two probes targeting mouse huntingtin (Htt): one detecting the spliced transcript that uses early cryptic polyadenylation sites in intron 1 (HTT1a), and one detecting full-length Htt (fl-HTT). Our analysis reveals considerable heterogeneity in mRNA accumulation: 16-63% of Q111 FOVs are classified as “extreme” (exceeding the 95th percentile of wildtype clustered mRNA levels), with striatum showing higher prevalence than cortex for both probes (HTT1a: 63% striatum, 31% cortex; fl-HTT: 44% striatum, 16%cortex). Extreme FOVs are characterized by elevated cluster numbers (2-6× more clusters per nucleus) and higher cluster density (1.3-1.7× more mRNA per µm 3 ). Cluster localization shows nuclear bias (∼68%) in normal FOVs, but extreme FOVs exhibit a shift toward cytoplasmic localization, particularly for fl-HTT (48% nuclear vs 68% in normal FOVs), though the interpretation of this shift requires further investigation. Despite the large dataset at the cellular level, our study included only 11 mice (9 Q111, 2 wildtype), and this limited sample size precluded robust statistical inference at the animal level. Nevertheless, these quantitative metrics provide a framework for investigating disease mechanisms and evaluating therapeutic interventions using RNAscope in future studies with larger cohorts.
Open AccessHigh-throughput quantification of huntingtin mRNA expression and aggregation in mouse brain using automated RNAscope imaging
Huntington’s disease (HD) is a repeat-associated neurodegenerative disorder traditionally characterized by toxic protein pathology resulting from expanded CAG repeats in the huntingtin (HTT) gene. In recent years, however, studies have identified repeat expansion–driven RNA pathology as an additional and potentially independent contributor to disease. In particular, mutant HTT transcripts containing expanded CAG repeats accumulate in the nucleus and form discrete RNA clusters, a feature shared with several other repeat-associated disorders. While protein aggregation and its downstream consequences have been extensively studied, our current understanding of the composition, organization, and dynamics of these nuclear mRNA clusters remains limited. Progress in this area has been constrained in part by the lack of robust methods to detect and quantify expanded HTT transcripts at single-molecule resolution within intact tissue. As a result, the contribution of RNA clustering to disease mechanisms, its relationship to repeat length, and its interaction with other pathological features of HD remain poorly defined. Here we present a high-throughput RNAscope™ pipeline that combines automated confocal imaging with rigorous microscope characterization to quantify both single mRNA molecules and multi-transcript clusters in fixed mouse brain tissue. Using 3D Gaussian point-spread function (PSF) fitting calibrated on 200 nm fluorescent beads and pointilistic image features from tissue data, we establish per-slide intensity thresholds from negative controls and normalize experimental signals to single-molecule reference intensities. The critical validation of our approach operates at two scales: for single molecules, the linear relationship between spot size and intensity (r 2 > 0.90) reflects variable probe binding along transcripts; for clusters, the linear scaling between cluster volume and mRNA content (R 2 > 0.98) confirms uniform probe accessibility and enables quantitative conversion of fluorescence intensity to absolute mRNA counts. Applied to HttQ111+/− knock-in mice across multiple ages, we analyzed thousands of fields of view (FOVs), detecting >900,000 single mRNA molecules and segmenting >1.9 million mRNA clusters using two probes targeting mouse huntingtin (Htt): one detecting the spliced transcript that uses early cryptic polyadenylation sites in intron 1 (HTT1a), and one detecting full-length Htt (fl-HTT). Our analysis reveals considerable heterogeneity in mRNA accumulation: 16-63% of Q111 FOVs are classified as “extreme” (exceeding the 95th percentile of wildtype clustered mRNA levels), with striatum showing higher prevalence than cortex for both probes (HTT1a: 63% striatum, 31% cortex; fl-HTT: 44% striatum, 16%cortex). Extreme FOVs are characterized by elevated cluster numbers (2-6× more clusters per nucleus) and higher cluster density (1.3-1.7× more mRNA per µm 3 ). Cluster localization shows nuclear bias (∼68%) in normal FOVs, but extreme FOVs exhibit a shift toward cytoplasmic localization, particularly for fl-HTT (48% nuclear vs 68% in normal FOVs), though the interpretation of this shift requires further investigation. Despite the large dataset at the cellular level, our study included only 11 mice (9 Q111, 2 wildtype), and this limited sample size precluded robust statistical inference at the animal level. Nevertheless, these quantitative metrics provide a framework for investigating disease mechanisms and evaluating therapeutic interventions using RNAscope in future studies with larger cohorts.
- Open Access
- 21 March 2025
- Published by University of Western Ontario, Western Libraries in Journal of Open Hardware
- Vol. 9 (1)
CubEd: a 3D printable fluorescence cube microscope optimized for classroom and teaching use.
“When all you have is a hammer, everything is a nail” diametrically opposes the “right tool for the job” mentality. After observing graduate students in the biological sciences often adopting the former approach towards fluorescence light microscopy – using religiously the closest available microscope rather than the most suitable on campus – we endeavored to shift mentality towards the latter through teaching how the tools work. We further observed that these students often lack an understanding of optics. To instill a practical knowledge of optics as applied in fluorescence microscopy, we set about to create an educational experience that linked theory and practice. As part of this effort, we provided students an opportunity to construct fluorescence microscopes in an open-ended, stepwise fashion with built-in features, such as the ability to track the beam along the beam path. As a result, we developed the CubEd, an easy-to-use, inexpensive, and extensible optics system that may lead students to a better understanding of how fluorescence microscopy works, and, as a result, will enable them to better design their own experiments in the future. This requires replacing expensive, closed system, boxed commercial microscopes with a modular, open frame system that allows direct access to the optics. Based on an early iteration of the UC2 microscope, the CubEd was conceived. It is an open-source microscope of modular design that balances cost, ease-of-use, flexibility of design, and extensibility.
- 21 March 2025
- Published by University of Western Ontario, Western Libraries in Journal of Open Hardware
- Vol. 9 (1)
Open AccessCubEd: a 3D printable fluorescence cube microscope optimized for classroom and teaching use.
“When all you have is a hammer, everything is a nail” diametrically opposes the “right tool for the job” mentality. After observing graduate students in the biological sciences often adopting the former approach towards fluorescence light microscopy – using religiously the closest available microscope rather than the most suitable on campus – we endeavored to shift mentality towards the latter through teaching how the tools work. We further observed that these students often lack an understanding of optics. To instill a practical knowledge of optics as applied in fluorescence microscopy, we set about to create an educational experience that linked theory and practice. As part of this effort, we provided students an opportunity to construct fluorescence microscopes in an open-ended, stepwise fashion with built-in features, such as the ability to track the beam along the beam path. As a result, we developed the CubEd, an easy-to-use, inexpensive, and extensible optics system that may lead students to a better understanding of how fluorescence microscopy works, and, as a result, will enable them to better design their own experiments in the future. This requires replacing expensive, closed system, boxed commercial microscopes with a modular, open frame system that allows direct access to the optics. Based on an early iteration of the UC2 microscope, the CubEd was conceived. It is an open-source microscope of modular design that balances cost, ease-of-use, flexibility of design, and extensibility.
- 11 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 12630-12646
MetaMax: an objective-sized instrument for advanced light microscope characterization and performance metadata collection
MetaMax is a device designed to replace the objective lens in light microscopes and provide a wide range of performance metadata that characterize microscope hardware behavior. MetaMax includes a large-area photodiode that is referenced against calibrated power meters to measure excitation light power and source stability; a broadband LED to quantify detector system responsivity and signal-dependent noise; a spectrometer to identify excitation wavelengths; an adjustable iris to simulate an objective’s back aperture; and a quadrant photodiode to assess beam alignment and aperture overfill. MetaMax enables users to collect performance metadata for quality control, image provenance, and comprehensive acquisition parameter delineation. It simplifies access to performance data that typically requires expert knowledge and expensive equipment to obtain, lowering the access barrier for users. Such performance data is crucial metadata for improving the reliability and reproducibility of microscopy images. The MetaMax aims to facilitate collaboration through data reusability and promote a more rigorous, transparent approach to scientific inquiry using light microscopy techniques. This work presents a detailed evaluation and comparison of several MetaMax prototypes.
- 11 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 12630-12646
MetaMax: an objective-sized instrument for advanced light microscope characterization and performance metadata collection
MetaMax is a device designed to replace the objective lens in light microscopes and provide a wide range of performance metadata that characterize microscope hardware behavior. MetaMax includes a large-area photodiode that is referenced against calibrated power meters to measure excitation light power and source stability; a broadband LED to quantify detector system responsivity and signal-dependent noise; a spectrometer to identify excitation wavelengths; an adjustable iris to simulate an objective’s back aperture; and a quadrant photodiode to assess beam alignment and aperture overfill. MetaMax enables users to collect performance metadata for quality control, image provenance, and comprehensive acquisition parameter delineation. It simplifies access to performance data that typically requires expert knowledge and expensive equipment to obtain, lowering the access barrier for users. Such performance data is crucial metadata for improving the reliability and reproducibility of microscopy images. The MetaMax aims to facilitate collaboration through data reusability and promote a more rigorous, transparent approach to scientific inquiry using light microscopy techniques. This work presents a detailed evaluation and comparison of several MetaMax prototypes.
- Open Access
- 8 September 2024
- Published by Springer Nature
3. Data Generation - Systems with an Area Detector v1
This protocol describes the measurement procedure to produce dark and inhomogeneously illuminated images with a light microscope system equipped with area detectors. The protocol can be followed according to the three different aims of microscope characterization described in the introduction of the protocol collection "Characterization of the Photon Conversion Factor, Noise, and Dynamic Range of Light Microscope Detection Systems". The protocol uses the microscope slide for inhomogeneous illumination described in protocol 2 and generates data which can be analyzed with protocol 5, to obtain the photon conversion factor, readnoise, and dynamic range of the detection system.
- 8 September 2024
- Published by Springer Nature
Open Access3. Data Generation - Systems with an Area Detector v1
This protocol describes the measurement procedure to produce dark and inhomogeneously illuminated images with a light microscope system equipped with area detectors. The protocol can be followed according to the three different aims of microscope characterization described in the introduction of the protocol collection "Characterization of the Photon Conversion Factor, Noise, and Dynamic Range of Light Microscope Detection Systems". The protocol uses the microscope slide for inhomogeneous illumination described in protocol 2 and generates data which can be analyzed with protocol 5, to obtain the photon conversion factor, readnoise, and dynamic range of the detection system.
- Open Access
- 8 September 2024
- Published by Springer Nature
Characterization of the Photon Conversion Factor, Noise, and Dynamic Range of Light Microscope Detection Systems v1
The protocols in this collection describe how to measure and analyze the photon conversation factor (PCF photo-electrons/count), readnoise, and dynamic range of a light microscopy detection system; which can either be a point detector or an area detector, using an in-homogeneous detector illumination scheme (as opposed to uniform illumination). The collection includes protocols on how to prepare a suitable sample for the acquisition, how to acquire data, as well as a respective analysis protocol. There are three aims a detection system can be characterized for, briefly: Aim 1 - experiment QC: Characterize the microscope performance using detection settings that match the experiment. Aim 2 - instrument QC.: Monitoring of microscope performance over time for service purposes, to maintain image quality constant and at high level. Aim 3 - system characterization: Full characterization of detection path performance under the range of settings applied by users. For a more detailed description refer to protocol 1. Introduction - Background and Aims. This protocol collection represents the collective experience of over 100 imaging scientists and industry experts. Measurements made by our working group with these protocols will be available in a public database. Please note, that this is an evolving document, to be versioned and updated, based on community feedback and new data.
- 8 September 2024
- Published by Springer Nature
Open AccessCharacterization of the Photon Conversion Factor, Noise, and Dynamic Range of Light Microscope Detection Systems v1
The protocols in this collection describe how to measure and analyze the photon conversation factor (PCF photo-electrons/count), readnoise, and dynamic range of a light microscopy detection system; which can either be a point detector or an area detector, using an in-homogeneous detector illumination scheme (as opposed to uniform illumination). The collection includes protocols on how to prepare a suitable sample for the acquisition, how to acquire data, as well as a respective analysis protocol. There are three aims a detection system can be characterized for, briefly: Aim 1 - experiment QC: Characterize the microscope performance using detection settings that match the experiment. Aim 2 - instrument QC.: Monitoring of microscope performance over time for service purposes, to maintain image quality constant and at high level. Aim 3 - system characterization: Full characterization of detection path performance under the range of settings applied by users. For a more detailed description refer to protocol 1. Introduction - Background and Aims. This protocol collection represents the collective experience of over 100 imaging scientists and industry experts. Measurements made by our working group with these protocols will be available in a public database. Please note, that this is an evolving document, to be versioned and updated, based on community feedback and new data.
- Open Access
- 8 September 2024
- Published by Springer Nature
1. Introduction - Background and Aims v1
This protocol is the introduction to the protocols collection "Characterization of the Photon Conversion Factor, Dark Noise, and Dynamic Range of Light Microscope Detection Systems". Here we describe in more detail the mission statement of QUAREP-LiMi Working Group 2, different aims of detection system characterization, a short guide to the protocols in the collection, and detection system basic theory underlying the protocols in this collection.
- 8 September 2024
- Published by Springer Nature
Open Access1. Introduction - Background and Aims v1
This protocol is the introduction to the protocols collection "Characterization of the Photon Conversion Factor, Dark Noise, and Dynamic Range of Light Microscope Detection Systems". Here we describe in more detail the mission statement of QUAREP-LiMi Working Group 2, different aims of detection system characterization, a short guide to the protocols in the collection, and detection system basic theory underlying the protocols in this collection.
- Open Access
- 8 September 2024
- Published by Springer Nature
2. Sample Preparation - An Easy-to-Prepare Sample Slide v1
This protocol describes how to create a high dynamic range fluorescent sample using basic office and microscopy lab tools. The protocol is based on the usage of the ink of a fluorescent text marker to create a thin fluorescent layer on a microscope cover glass (Olevsko et al., 2021). The result is a carrier with a thin, homogeneous fluorescent film with abrupt edges and a thickness in the order of a few micrometers. This type of sample can be used to make images with a smooth gradient going from maximum intensity to background, as described in the protocols for determination of a detector’s photon conversion factor.
- 8 September 2024
- Published by Springer Nature
Open Access2. Sample Preparation - An Easy-to-Prepare Sample Slide v1
This protocol describes how to create a high dynamic range fluorescent sample using basic office and microscopy lab tools. The protocol is based on the usage of the ink of a fluorescent text marker to create a thin fluorescent layer on a microscope cover glass (Olevsko et al., 2021). The result is a carrier with a thin, homogeneous fluorescent film with abrupt edges and a thickness in the order of a few micrometers. This type of sample can be used to make images with a smooth gradient going from maximum intensity to background, as described in the protocols for determination of a detector’s photon conversion factor.
- Open Access
- 27 May 2024
- Published by Springer Nature
Refractive index adjusted imaging medium: Iodixanol (RI ~ 1.4) - Yeast v1
This protocol describes the steps to prepare imaging medium for Saccharomyces cerevisiae with adjusted refractive index. This medium is optimized for fluorescence imaging by the reduction of auto-fluorescence through an abundance of Adenine [1] and the repression of of the Met-promoted pp7- CP expression [2].
- 27 May 2024
- Published by Springer Nature
Open AccessRefractive index adjusted imaging medium: Iodixanol (RI ~ 1.4) - Yeast v1
This protocol describes the steps to prepare imaging medium for Saccharomyces cerevisiae with adjusted refractive index. This medium is optimized for fluorescence imaging by the reduction of auto-fluorescence through an abundance of Adenine [1] and the repression of of the Met-promoted pp7- CP expression [2].
- Open Access
- 19 January 2024
- Published by Springer Nature
Illumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.
- 19 January 2024
- Published by Springer Nature
Open AccessIllumination Power, Stability, and Linearity Measurements for Confocal, Widefield and Multiphoton Microscopes v1
To obtain accurate, reproducible, and interpretable data when conducting imaging experiments, it is critical to consider external factors affecting data acquisition at various steps of the experimental workflow. Illumination power and stability represent two critical factors, especially when comparing fluorescence intensities between images during a time-lapse experiment or experiments performed at different times or on different microscopes. The fluorescence signal can be generated by different types of light sources. These light sources and their coupling elements (e.g., fibers) can display varying performances over time as they age, move, or as environmental conditions change. Unfortunately, microscope users can often only set illumination power as a percentage of its maximal output and may, therefore, not be aware of potential performance changes. It is important to recognize that a set percentage will not always yield the same illumination power in Watts at the objective over the course of an experiment, not to mention between days or systems. This means that selecting for example 10% output may lead to different experimental results over time or even between two microscopes of the same model. In addition to illumination stability, working within the linear range of the illumination power allows to adjust accurately the illumination power absolute value (in mW) using a fraction (or %) of its maximal value through the imaging software. If you are responsible for system maintenance, routinely measuring the illumination power, stability, and linearity over time can help you detect issues that affect the integrity of the system and thus the reproducibility of an experiment. This protocol describes how to measure the stability and linearity of the illumination power using calibrated external power sensors. This protocol is intended for confocal systems (raster scanning and spinning disks), Multi-photon systems (used for 2P- or 3P-imaging, SHG-imaging, etc.), and widefield systems. It represents the collective experience of over 50 imaging scientists.