Esmée J. Grobbee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Esmée J. Grobbee has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Manon C. W. Spaander
Department of Gastroenterology and Hepatology Erasmus University Medical Center Rotterdam The Netherlands
5 shared publications - Ernst J. Kuipers
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
4 shared publications - Iris Lansdorp-Vogelaar
Department of Public Health Erasmus University Medical Center Rotterdam The Netherlands
3 shared publications - Eline Schreuders
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
2 shared publications - Evelien Dekker
Department of Gastroenterology and Hepatology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands
2 shared publications Manon van der Vlugt
Cancer Center Amsterdam, Department of Gastroenterology and Hepatology, Academic Medical Centre Amsterdam, Amsterdam, the Netherlands
2 shared publications
Latest Publications
- Open Access
- 1 April 2020
- Published by Wiley in United European Gastroenterology Journal
- Vol. 8 (3) , 293-302
First steps towards combining faecal immunochemical testing with the gut microbiome in colorectal cancer screening
Objectives: Many countries use faecal immunochemical testing (FIT) to screen for colorectal cancer. There is increasing evidence that faecal microbiota play a crucial role in colorectal cancer carcinogenesis. We assessed the possibility of measuring faecal microbial features in FIT as potential future biomarkers in colorectal cancer screening.Methods: Bacterial stability over time and the possibility of bacterial contamination were evaluated using quantitative polymerase chain reaction analysis. Positive FIT samples (n = 200) of an average‐risk screening cohort were subsequently analysed for universal 16S, and bacteria. Escherichia coli (E. coli), Fusobacterium nucleatum (F. nucleatum), Bacteroidetes and Faecalibacterium prausnitzii (F. prausnitzii) by qPCR. The results were compared with colonoscopy findings.Results: Faecal microbiota in FIT were stably measured up to six days for E. coli (p = 0.53), F. nucleatum (p = 0.30), Bacteroidetes (p = 0.05) and F. prausnitzii (p = 0.62). Overall presence of bacterial contamination in FIT controls was low. Total bacterial load (i.e. 16S) was significantly higher in patients with colorectal cancer and high‐grade dysplasia (p = 0.006). For the individual bacteria tested, no association was found with colonic lesions.Conclusions: These results show that the faecal microbial content can be measured in FIT samples and remains stable for six days. Total bacterial load was higher in colorectal cancer and high‐grade dysplasia. These results pave the way for further research to determine the potential role of microbiota assessment in FIT screening.
- 1 April 2020
- Published by Wiley in United European Gastroenterology Journal
- Vol. 8 (3) , 293-302
Open AccessFirst steps towards combining faecal immunochemical testing with the gut microbiome in colorectal cancer screening
Objectives: Many countries use faecal immunochemical testing (FIT) to screen for colorectal cancer. There is increasing evidence that faecal microbiota play a crucial role in colorectal cancer carcinogenesis. We assessed the possibility of measuring faecal microbial features in FIT as potential future biomarkers in colorectal cancer screening.Methods: Bacterial stability over time and the possibility of bacterial contamination were evaluated using quantitative polymerase chain reaction analysis. Positive FIT samples (n = 200) of an average‐risk screening cohort were subsequently analysed for universal 16S, and bacteria. Escherichia coli (E. coli), Fusobacterium nucleatum (F. nucleatum), Bacteroidetes and Faecalibacterium prausnitzii (F. prausnitzii) by qPCR. The results were compared with colonoscopy findings.Results: Faecal microbiota in FIT were stably measured up to six days for E. coli (p = 0.53), F. nucleatum (p = 0.30), Bacteroidetes (p = 0.05) and F. prausnitzii (p = 0.62). Overall presence of bacterial contamination in FIT controls was low. Total bacterial load (i.e. 16S) was significantly higher in patients with colorectal cancer and high‐grade dysplasia (p = 0.006). For the individual bacteria tested, no association was found with colonic lesions.Conclusions: These results show that the faecal microbial content can be measured in FIT samples and remains stable for six days. Total bacterial load was higher in colorectal cancer and high‐grade dysplasia. These results pave the way for further research to determine the potential role of microbiota assessment in FIT screening.
- 1 August 2018
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 16 (8) , 1237-1243.e2
Risk of Oral and Upper Gastrointestinal Cancers in Persons With Positive Results From a Fecal Immunochemical Test in a Colorectal Cancer Screening Program
- 1 August 2018
- Published by Elsevier in Clinical Gastroenterology and Hepatology
- Vol. 16 (8) , 1237-1243.e2
Risk of Oral and Upper Gastrointestinal Cancers in Persons With Positive Results From a Fecal Immunochemical Test in a Colorectal Cancer Screening Program
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S755
Mo1696 Adherence to Colorectal Cancer Screening: 4 Rounds of Fecal Immunochemical Test (FIT) Based Screening
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S755
Mo1696 Adherence to Colorectal Cancer Screening: 4 Rounds of Fecal Immunochemical Test (FIT) Based Screening
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S45-S46
177 Fecal Hemoglobin Concentration of a Negative FIT Predicts Risk of Future Advanced Neoplasia: A Long-Term Follow-Up Study of Population-Based FIT Screenees
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S45-S46
177 Fecal Hemoglobin Concentration of a Negative FIT Predicts Risk of Future Advanced Neoplasia: A Long-Term Follow-Up Study of Population-Based FIT Screenees
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S751
Mo1688 Four Rounds of Two-Sample Fecal Immunochemical Occult Blood Test Screening
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S751
Mo1688 Four Rounds of Two-Sample Fecal Immunochemical Occult Blood Test Screening