Mototaka Arakawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mototaka Arakawa has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
- Yuji Ohashi
New Industry Creation Hatchery Center (NICHe), Tohoku University, Sendai, Japan
43 shared publications Jun-Ichi Kushibiki
Tohoku University, Graduate School of Engineering, Sendai, Japan
42 shared publications- Hiroshi Kanai
Graduate School of Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
18 shared publications Hiroshi Kanai
Graduate School of Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
14 shared publications- Shohei Mori
Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
14 shared publications Kazuto Kobayashi
Division of Research and Development, Honda Electronics Co. Ltd., Toyohashi, Aichi, 441-3193, Japan
12 shared publications
Latest Publications
- 27 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (7) , 07SP30
Measurement method for sound speed and attenuation of blood vessel tissue using acoustic microscope with a high-frequency range probe
Acoustic microscopy can noninvasively measure acoustic properties, such as sound speed, density, and the attenuation coefficient of tissue sections or cells. The speed of sound can be estimated using a pulse-spectrum method; however, it may not be calculated accurately for samples with high attenuation. Moreover, a method for calculating the attenuation coefficient was proposed by Rohrbach et al., but the estimation error was large. Therefore, we propose a method for calculating the sound speed of a sample with high attenuation more accurately by correcting for the attenuation effect and attenuation coefficient. To achieve this, the acoustic impedance of the sample is estimated in advance. Numerical calculations of the normalized and interference spectra based on the results of both the conventional and proposed methods were performed to validate the proposed method.
- 27 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (7) , 07SP30
Measurement method for sound speed and attenuation of blood vessel tissue using acoustic microscope with a high-frequency range probe
Acoustic microscopy can noninvasively measure acoustic properties, such as sound speed, density, and the attenuation coefficient of tissue sections or cells. The speed of sound can be estimated using a pulse-spectrum method; however, it may not be calculated accurately for samples with high attenuation. Moreover, a method for calculating the attenuation coefficient was proposed by Rohrbach et al., but the estimation error was large. Therefore, we propose a method for calculating the sound speed of a sample with high attenuation more accurately by correcting for the attenuation effect and attenuation coefficient. To achieve this, the acoustic impedance of the sample is estimated in advance. Numerical calculations of the normalized and interference spectra based on the results of both the conventional and proposed methods were performed to validate the proposed method.
- Open Access
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47 (2) , 197-201
Optimization of focal-region width to estimate the size of red blood cell aggregates using ultrasound backscatter characteristics
We previously proposed a noninvasive and quantitative method for estimating the aggregate size of red blood cells (RBCs) based on ultrasound backscatter characteristics. In this study, we improved the estimation accuracy by appropriately setting the focal-region width of the ultrasound beam used to calculate the reference scattering power spectra. Phantom experiments using blood-mimicking particles demonstrated that a wider focal region yielded an estimate closer to the true value and reduced the root-mean-square error (RMSE) of the spectral fitting compared with the conventional width. This result indicates that an appropriate focal-region size enhances the accuracy of RBC aggregate size estimation.
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47 (2) , 197-201
Open AccessOptimization of focal-region width to estimate the size of red blood cell aggregates using ultrasound backscatter characteristics
We previously proposed a noninvasive and quantitative method for estimating the aggregate size of red blood cells (RBCs) based on ultrasound backscatter characteristics. In this study, we improved the estimation accuracy by appropriately setting the focal-region width of the ultrasound beam used to calculate the reference scattering power spectra. Phantom experiments using blood-mimicking particles demonstrated that a wider focal region yielded an estimate closer to the true value and reduced the root-mean-square error (RMSE) of the spectral fitting compared with the conventional width. This result indicates that an appropriate focal-region size enhances the accuracy of RBC aggregate size estimation.
- 24 February 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (4) , 048002
Thoracic spine imaging method for epidural anesthesia using steering-transmitted ultrasound: in vivo study
This study aimed to improve the visualization of the thoracic spine gap during epidural anesthesia using steering-transmitted ultrasound beams. Previously, we introduced a beamforming method that used amplitude characteristics to distinguish ultrasound reflections from scattering. Here, a correction factor was added to further emphasize bone echoes, and the method was applied to in vivo measurements of three healthy participants. The results showed improved contrast between the bone and gap regions compared to conventional B-mode imaging and our previous method.
- 24 February 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (4) , 048002
Thoracic spine imaging method for epidural anesthesia using steering-transmitted ultrasound: in vivo study
This study aimed to improve the visualization of the thoracic spine gap during epidural anesthesia using steering-transmitted ultrasound beams. Previously, we introduced a beamforming method that used amplitude characteristics to distinguish ultrasound reflections from scattering. Here, a correction factor was added to further emphasize bone echoes, and the method was applied to in vivo measurements of three healthy participants. The results showed improved contrast between the bone and gap regions compared to conventional B-mode imaging and our previous method.
- 22 January 2026
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 53 (3) , 259-266
Phantom experiment for thoracic spine gap delineation using steering-transmitted ultrasound to assist epidural anesthesia
Epidural anesthesia under real-time ultrasound guidance has been studied to enhance puncture safety. However, in the thoracic spine, where the anatomy is complex and the interlaminar space is narrow, improved image quality is necessary. Because imaging quality is degraded in bones that are greatly tilted relative to the probe, we aimed to improve the imaging quality by steering the transmitted ultrasonic beam. We investigated a method to improve bone visibility by selecting appropriate transmit steering angles and receiving aperture ranges for each of the two bones forming the interlaminar space, and by compensating for the directivity of the receiving elements. The proposed method emphasized the delineation of a bone phantom near the gap corresponding to the puncture site. Furthermore, when comparing the contrast ratio in the region of interest of the bone and gap areas, the proposed method showed an improvement of 24.2 dB on the left side and 4.2 dB on the right side compared to the conventional B-mode image. The proposed method was confirmed to emphasize the bones and is expected to improve the image quality of the thoracic spine gap.
- 22 January 2026
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 53 (3) , 259-266
Phantom experiment for thoracic spine gap delineation using steering-transmitted ultrasound to assist epidural anesthesia
Epidural anesthesia under real-time ultrasound guidance has been studied to enhance puncture safety. However, in the thoracic spine, where the anatomy is complex and the interlaminar space is narrow, improved image quality is necessary. Because imaging quality is degraded in bones that are greatly tilted relative to the probe, we aimed to improve the imaging quality by steering the transmitted ultrasonic beam. We investigated a method to improve bone visibility by selecting appropriate transmit steering angles and receiving aperture ranges for each of the two bones forming the interlaminar space, and by compensating for the directivity of the receiving elements. The proposed method emphasized the delineation of a bone phantom near the gap corresponding to the puncture site. Furthermore, when comparing the contrast ratio in the region of interest of the bone and gap areas, the proposed method showed an improvement of 24.2 dB on the left side and 4.2 dB on the right side compared to the conventional B-mode image. The proposed method was confirmed to emphasize the bones and is expected to improve the image quality of the thoracic spine gap.
- 1 April 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (4) , 04SP39
Precise estimation of elastic modulus of radial artery using blood pressure and vessel wall strain measured by ultrasound and photoplethysmography
In an earlier study, we investigated methods for estimating the elastic modulus of blood vessel walls for early diagnosis of atherosclerosis. Because the pulse pressure varies from beat to beat, in the present study, we proposed a method for estimating the elastic modulus of the vessel walls that simultaneously measures the pulse pressure and vessel wall strain due to the pulse pressure; this method estimates the systolic and diastolic blood pressures from the vessel diameter and pulse wave velocity. Consequently, changes in vessel wall strain in response to beat-by-beat pulse pressure variation were measured. In the elastic modulus estimation, the maximum deviation among consecutive beats was reduced, and the reproducibility of elastic modulus estimation was improved. Hence, we conclude that simultaneous measurement of vessel wall strain and pulse pressure is effective in improving the reliability of elastic modulus estimation.
- 1 April 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (4) , 04SP39
Precise estimation of elastic modulus of radial artery using blood pressure and vessel wall strain measured by ultrasound and photoplethysmography
In an earlier study, we investigated methods for estimating the elastic modulus of blood vessel walls for early diagnosis of atherosclerosis. Because the pulse pressure varies from beat to beat, in the present study, we proposed a method for estimating the elastic modulus of the vessel walls that simultaneously measures the pulse pressure and vessel wall strain due to the pulse pressure; this method estimates the systolic and diastolic blood pressures from the vessel diameter and pulse wave velocity. Consequently, changes in vessel wall strain in response to beat-by-beat pulse pressure variation were measured. In the elastic modulus estimation, the maximum deviation among consecutive beats was reduced, and the reproducibility of elastic modulus estimation was improved. Hence, we conclude that simultaneous measurement of vessel wall strain and pulse pressure is effective in improving the reliability of elastic modulus estimation.
- Open Access
- 3 June 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (6) , 06SP11
Estimation of red blood cell aggregation size using power spectrum considering density of red blood cells in focal region
We have studied a noninvasive and quantitative method for measuring the aggregate size of red blood cells (RBCs). In our previous study, the scattering power spectrum obtained from the vascular lumen was fitted to the reference scattering spectra calculated from the scattering spectrum of a single-sphere scatterer. In this paper, we propose a method for calculating the reference scattering spectra by summing the scattering spectra for numerous scatterers in the ultrasound focal region. By applying this method to the size estimation of microparticles simulating RBC aggregates, the estimated sizes are found to be close to the true values. In in vivo measurements, the estimated sizes at rest are equivalent to the size of a single sphere with the same volume as an RBC, and those during avascularization are larger than those at rest, which is reasonable. The proposed method has the potential to accurately estimate the size of RBC aggregates.
- 3 June 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (6) , 06SP11
Open AccessEstimation of red blood cell aggregation size using power spectrum considering density of red blood cells in focal region
We have studied a noninvasive and quantitative method for measuring the aggregate size of red blood cells (RBCs). In our previous study, the scattering power spectrum obtained from the vascular lumen was fitted to the reference scattering spectra calculated from the scattering spectrum of a single-sphere scatterer. In this paper, we propose a method for calculating the reference scattering spectra by summing the scattering spectra for numerous scatterers in the ultrasound focal region. By applying this method to the size estimation of microparticles simulating RBC aggregates, the estimated sizes are found to be close to the true values. In in vivo measurements, the estimated sizes at rest are equivalent to the size of a single sphere with the same volume as an RBC, and those during avascularization are larger than those at rest, which is reasonable. The proposed method has the potential to accurately estimate the size of RBC aggregates.
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP03
Appropriate indicator of modeling error for threshold-based model selection in statistics-based ultrasound tissue characterization
Analysis of the envelope statistics of ultrasound echo signals contributes to quantitative tissue characterization in medical ultrasound. Many probability distribution model functions have been studied, and the model function that should be used for tissue characterization depends on the type of disease, even in the same organ. Thus, an appropriate model selection is important for an accurate diagnosis. In this study, we aimed to select a model using threshold processing for modeling errors instead of a simple selection by minimizing the modeling error. For this purpose, we compared several indicators of modeling errors using random number simulations, ultrasonic simulation, and phantom experiment. The results validated that the Mahalanobis distance of moments is an appropriate indicator because it enables the use of a constant threshold value, regardless of the type of model function and data length.
- 1 May 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (5) , 05SP03
Appropriate indicator of modeling error for threshold-based model selection in statistics-based ultrasound tissue characterization
Analysis of the envelope statistics of ultrasound echo signals contributes to quantitative tissue characterization in medical ultrasound. Many probability distribution model functions have been studied, and the model function that should be used for tissue characterization depends on the type of disease, even in the same organ. Thus, an appropriate model selection is important for an accurate diagnosis. In this study, we aimed to select a model using threshold processing for modeling errors instead of a simple selection by minimizing the modeling error. For this purpose, we compared several indicators of modeling errors using random number simulations, ultrasonic simulation, and phantom experiment. The results validated that the Mahalanobis distance of moments is an appropriate indicator because it enables the use of a constant threshold value, regardless of the type of model function and data length.
- 1 April 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (4) , 048003
Method for measuring time waveforms of minute sinusoidal displacements using continuous waves with a network analyzer
This study proposes a method for precise measurement of time waveforms of minute sinusoidal displacements using continuous waves. The technique involves measuring the S-parameter of ultrasonic waves reflected from an object undergoing sinusoidal vibration with a network analyzer. When the sinusoidal displacement is not sufficiently small, second-order side peaks emerge in its inverse Fourier transform, alongside the main and first-order side peaks. This method, which incorporates second-order side peaks previously overlooked, enhances the accuracy of measurements. It facilitates precise measurement of sinusoidal displacements ranging from 0.3 to 50 μm at frequencies between 10 and 300 Hz.
- 1 April 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (4) , 048003
Method for measuring time waveforms of minute sinusoidal displacements using continuous waves with a network analyzer
This study proposes a method for precise measurement of time waveforms of minute sinusoidal displacements using continuous waves. The technique involves measuring the S-parameter of ultrasonic waves reflected from an object undergoing sinusoidal vibration with a network analyzer. When the sinusoidal displacement is not sufficiently small, second-order side peaks emerge in its inverse Fourier transform, alongside the main and first-order side peaks. This method, which incorporates second-order side peaks previously overlooked, enhances the accuracy of measurements. It facilitates precise measurement of sinusoidal displacements ranging from 0.3 to 50 μm at frequencies between 10 and 300 Hz.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Publisher’s Note: “A novel ultrasonic method for measuring minute sinusoidal displacement by network analyzer” [Rev. Sci. Instrum. 95, 025105 (2024)]
This article was originally published online on 12 February 2024 with typesetting errors. In the fourth line of the abstract, “on” was changed to “to.” In the e
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Publisher’s Note: “A novel ultrasonic method for measuring minute sinusoidal displacement by network analyzer” [Rev. Sci. Instrum. 95, 025105 (2024)]
This article was originally published online on 12 February 2024 with typesetting errors. In the fourth line of the abstract, “on” was changed to “to.” In the e
- Open Access
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
A novel ultrasonic method for measuring minute sinusoidal displacement by network analyzer
We developed a method for generating continuous sinusoidal displacements of an object to estimate viscoelastic parameters. However, the amplitude of the displacement caused by the ultrasonic excitation force under safe guidelines was small (a few micrometers), and it was difficult to stably measure the displacement. Therefore, to stably measure the amplitude of sinusoidal displacement as small as the order of micrometers, we proposed a novel method using a network analyzer. Ultrasonic waves were irradiated using an ultrasonic transducer to an object vibrating sinusoidally. The S parameter of the first reflected wave received from the surface of the object was measured using a network analyzer. The S parameter and the inverse Fourier transform were formulated theoretically, and the amplitude of the sinusoidal displacement of the object was estimated from the amplitude characteristics of the inverse Fourier-transformed signal. The proposed method was applied to measure sinusoidal displacements on the order of micrometers from 10 to 300 Hz on an object using a water tank experiment. The obtained sinusoidal displacement agreed well with the reference values measured using a laser displacement meter. The proposed method can accurately measure minute sinusoidal displacements that occur on an object.
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Open AccessA novel ultrasonic method for measuring minute sinusoidal displacement by network analyzer
We developed a method for generating continuous sinusoidal displacements of an object to estimate viscoelastic parameters. However, the amplitude of the displacement caused by the ultrasonic excitation force under safe guidelines was small (a few micrometers), and it was difficult to stably measure the displacement. Therefore, to stably measure the amplitude of sinusoidal displacement as small as the order of micrometers, we proposed a novel method using a network analyzer. Ultrasonic waves were irradiated using an ultrasonic transducer to an object vibrating sinusoidally. The S parameter of the first reflected wave received from the surface of the object was measured using a network analyzer. The S parameter and the inverse Fourier transform were formulated theoretically, and the amplitude of the sinusoidal displacement of the object was estimated from the amplitude characteristics of the inverse Fourier-transformed signal. The proposed method was applied to measure sinusoidal displacements on the order of micrometers from 10 to 300 Hz on an object using a water tank experiment. The obtained sinusoidal displacement agreed well with the reference values measured using a laser displacement meter. The proposed method can accurately measure minute sinusoidal displacements that occur on an object.