Giovanni Costi
Giovanni Costi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Di Domenico
CUNA, Corso Galileo Ferraris 61, 10128 Torino, Italy
1 shared publication - Barouch Giechaskiel
European Commission, Joint Research Centre, 21027 Ispra, Italy
1 shared publication - Francesco Di Tanno
Horiba, via Giovani Batista Feroggio 30, 10128 Torino, TO, Italy
1 shared publication - Gisella Montabone
FCA—Product Engineering Sangone, strada del Drosso 145, 10135 Torino, TO, Italy
1 shared publication - Maria Vittoria Prati
Istituto Motori CNR
1 shared publication - Mario Sammarco
FCA—Powertrain Engineering Pomigliano, via ex-Aeroporto, 80038 Pomigliano d’Arco, NA, Italy
1 shared publication
Latest Publications
- Open Access
- 17 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2275
Inter-Laboratory Correlation Exercise with Portable Emissions Measurement Systems (PEMS) on Chassis Dynamometers
The recently introduced Real Driving Emissions (RDE) light-duty vehicle emissions regulation requires testing with Portable Emissions Measurement Systems (PEMS) during type approval and in-service conformity. The studies on the accuracy of PEMS today are limited. An inter-laboratory correlation exercise with PEMS took place in Italy in 2017. Eight laboratories measured exhaust emissions from a Golden Euro 6 gasoline vehicle with a Golden PEMS installed in it, along with the individual lab’s own PEMS, following the regulated laboratory method (bags from the dilution tunnel). The data of the exercise were used to estimate the repeatability and reproducibility of the methodology with PEMS. The statistical analysis estimated reproducibility of 2.9% (bags) to 5.5% (lab PEMS) for CO2, 20–25% for CO (all methods), 23–31% for NOx (all methods), and 29% (tunnel, Golden PEMS) to 39% (lab PEMS) for particle number. The mean differences of the PEMS to the regulated method were ±1.5 g/km (or ±1%) for CO2, x and 1 × 1011 particles/km (40%) for particle number. The results of this study confirm the satisfactory performance of PEMS and the permissible tolerances introduced in RDE regulation.
- 17 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2275
Open AccessInter-Laboratory Correlation Exercise with Portable Emissions Measurement Systems (PEMS) on Chassis Dynamometers
The recently introduced Real Driving Emissions (RDE) light-duty vehicle emissions regulation requires testing with Portable Emissions Measurement Systems (PEMS) during type approval and in-service conformity. The studies on the accuracy of PEMS today are limited. An inter-laboratory correlation exercise with PEMS took place in Italy in 2017. Eight laboratories measured exhaust emissions from a Golden Euro 6 gasoline vehicle with a Golden PEMS installed in it, along with the individual lab’s own PEMS, following the regulated laboratory method (bags from the dilution tunnel). The data of the exercise were used to estimate the repeatability and reproducibility of the methodology with PEMS. The statistical analysis estimated reproducibility of 2.9% (bags) to 5.5% (lab PEMS) for CO2, 20–25% for CO (all methods), 23–31% for NOx (all methods), and 29% (tunnel, Golden PEMS) to 39% (lab PEMS) for particle number. The mean differences of the PEMS to the regulated method were ±1.5 g/km (or ±1%) for CO2, x and 1 × 1011 particles/km (40%) for particle number. The results of this study confirm the satisfactory performance of PEMS and the permissible tolerances introduced in RDE regulation.