Mahdieh Gholami Mayani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mahdieh Gholami Mayani has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Dag Breiby
Norwegian University of Science and Technology
1 shared publication- Dag Werner Breiby
Department of Physics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
1 shared publication - Francisco Javier Herraiz-Martinez
Institute for Research in Technology (IIT), ICAI School of Engineering, Universidad Pontificia Comillas, Madrid, Spain
1 shared publication - Javier Matanza
Comillas Pontifical University
1 shared publication - Jonas Rudshaug
Norwegian Defence Estates Agency
1 shared publication - Kim Robert Tekseth
Norwegian Univ Sci & Technol NTNU, Dept Phys, Hgsk Ringen 5, N-7491 Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 10 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (2)
Mapping surface flaws on float glass through Fourier ptychographic quantitative phase imaging
Glass is increasingly used as a load-carrying construction material both in buildings and vehicles, and growing emphasis is consequently given to its safety properties. How the mechanical properties of glass relate to the inevitable presence of surface defects, and how these defects can be efficiently measured, are important scientific questions. We demonstrate that Fourier ptychographic microscopy can be used to detect, count, and topographically measure glass surface defects through the reconstructed quantitative phase images. We characterized several key parameters, including the length, width, orientation, eccentricity, and depth of the identified flaws and cross-validated our results with atomic force microscopy topography maps. The sign of the phase shift makes it feasible to discriminate surface flaws from impurities residing on the glass surface. The method is quantitative, scalable, and allows extended areas to be screened. The proposed technique has the potential to improve the understanding of surface flaws in glass and thereby contribute to better mechanical models for predicting glass failure and fracture under quasi-static and dynamic loading.
- 10 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (2)
Open AccessMapping surface flaws on float glass through Fourier ptychographic quantitative phase imaging
Glass is increasingly used as a load-carrying construction material both in buildings and vehicles, and growing emphasis is consequently given to its safety properties. How the mechanical properties of glass relate to the inevitable presence of surface defects, and how these defects can be efficiently measured, are important scientific questions. We demonstrate that Fourier ptychographic microscopy can be used to detect, count, and topographically measure glass surface defects through the reconstructed quantitative phase images. We characterized several key parameters, including the length, width, orientation, eccentricity, and depth of the identified flaws and cross-validated our results with atomic force microscopy topography maps. The sign of the phase shift makes it feasible to discriminate surface flaws from impurities residing on the glass surface. The method is quantitative, scalable, and allows extended areas to be screened. The proposed technique has the potential to improve the understanding of surface flaws in glass and thereby contribute to better mechanical models for predicting glass failure and fracture under quasi-static and dynamic loading.
- Open Access
- 4 April 2022
- Published by Wiley
Improved Resolution Fourier Ptychography Scheme Using Oil-Filled Dome-Shaped LED array
Utilizing angular-varied illumination in Fourier Ptychography (FP), the resolution of optical microscopes can be increased and the phase of the sample can also be recovered while maintaining a wide field-of-view. In this work, an FP microscopy imaging setup is demonstrated using a 10X 0.28NA objective lens and a dome-shaped LED array illuminator. By increasing the refractive index of the medium between the sample and light sources using oil filled dome, a synthetic system NA of 0.68 is achieved using only 37 LEDs. The measured resolution of 345 nm at a wavelength of 530 nm closely matches the theoretical prediction. Furthermore, the results of the oil-medium illumination are compared to free-space illumination. The oil immersion on the illumination side effectively enhances the illumination NA as compared to air and reduces the need for far off-axis LEDs. The result is high-resolution FP imaging with relatively fewer LEDs providing both short capture and reconstruction times.
- 4 April 2022
- Published by Wiley
Open AccessImproved Resolution Fourier Ptychography Scheme Using Oil-Filled Dome-Shaped LED array
Utilizing angular-varied illumination in Fourier Ptychography (FP), the resolution of optical microscopes can be increased and the phase of the sample can also be recovered while maintaining a wide field-of-view. In this work, an FP microscopy imaging setup is demonstrated using a 10X 0.28NA objective lens and a dome-shaped LED array illuminator. By increasing the refractive index of the medium between the sample and light sources using oil filled dome, a synthetic system NA of 0.68 is achieved using only 37 LEDs. The measured resolution of 345 nm at a wavelength of 530 nm closely matches the theoretical prediction. Furthermore, the results of the oil-medium illumination are compared to free-space illumination. The oil immersion on the illumination side effectively enhances the illumination NA as compared to air and reduces the need for far off-axis LEDs. The result is high-resolution FP imaging with relatively fewer LEDs providing both short capture and reconstruction times.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Resonator-Based Microwave Metamaterial Sensors for Instrumentation: Survey, Classification, and Performance Comparison
Metamaterials are widely used as sensors in a large range of applications due to their unusual properties not found in nature. This review’s purpose is to focus on recent metamaterial-based electromagnetic sensors, particularly on the structures that integrate the metamaterials in antenna or transmission lines for their further integration in measurement instruments. The approach followed in the review is to highlight sensitivity and quality factor (Q-factor) as they are crucial parameters in any sensor; the corpus of literature analyzed lead to the finding that the adoption of metamaterials are a key factor in successfully decreasing the size of the structures while maintaining a high Q-factor value and reducing losses. Additionally, a new metamaterial-based sensors’ taxonomy is proposed to classify them into three main categories: frequency-variation sensors, coupling-based sensors and differential sensors. A tabular comparison of the specifications of different sensors provides further insights into their different capabilities and will allow future researchers to efficiently find and compare their prototypes with state-of-the-art devices.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Resonator-Based Microwave Metamaterial Sensors for Instrumentation: Survey, Classification, and Performance Comparison
Metamaterials are widely used as sensors in a large range of applications due to their unusual properties not found in nature. This review’s purpose is to focus on recent metamaterial-based electromagnetic sensors, particularly on the structures that integrate the metamaterials in antenna or transmission lines for their further integration in measurement instruments. The approach followed in the review is to highlight sensitivity and quality factor (Q-factor) as they are crucial parameters in any sensor; the corpus of literature analyzed lead to the finding that the adoption of metamaterials are a key factor in successfully decreasing the size of the structures while maintaining a high Q-factor value and reducing losses. Additionally, a new metamaterial-based sensors’ taxonomy is proposed to classify them into three main categories: frequency-variation sensors, coupling-based sensors and differential sensors. A tabular comparison of the specifications of different sensors provides further insights into their different capabilities and will allow future researchers to efficiently find and compare their prototypes with state-of-the-art devices.
- 21 November 2018
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 11 (1) , 94-103
Time-domain analysis of a CRLH coupled-line coupler using the CN-FDTD method
In this study, the implicit Crank–Nicolson finite-difference time-domain (CN-FDTD) method is applied to discretize the governing telegrapher's equations of a composite right-/left-handed (CRLH) coupled-line coupler. The unconditionally stable CN-FDTD is compared with the conventional leap-frog (LF) FDTD method. The results obtained from the CN-FDTD scheme show up to 10 times increase in the temporal step size, reflecting in a dramatic decrease in processing time; in addition to having a good agreement with the LF method and the measurements.
- 21 November 2018
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 11 (1) , 94-103
Time-domain analysis of a CRLH coupled-line coupler using the CN-FDTD method
In this study, the implicit Crank–Nicolson finite-difference time-domain (CN-FDTD) method is applied to discretize the governing telegrapher's equations of a composite right-/left-handed (CRLH) coupled-line coupler. The unconditionally stable CN-FDTD is compared with the conventional leap-frog (LF) FDTD method. The results obtained from the CN-FDTD scheme show up to 10 times increase in the temporal step size, reflecting in a dramatic decrease in processing time; in addition to having a good agreement with the LF method and the measurements.