Yiyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yiyu Li has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Jiaojie Chen
National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China
2 shared publications - Jun Jiang
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China
2 shared publications Ahmed Elsheikh
1 shared publicationBangXun Mao
1 shared publicationChangChang He
1 shared publicationChenHao Zhao
1 shared publication
Latest Publications
- Open Access
Array-Patterned Micro-Structures in Spectacle Lenses Designed for Myopia Control via Image Blur
Using micro-structure components in spectacle lenses has enabled myopia progression control in children and teenagers. However, the optical design of these spectacle lenses has never been discussed, leading to a lack of correct understanding of the underlying optical treatment principles. In this work, array-patterned hexagonal lenslets with two powers of opposite signs were proposed to construct a lenslet array-integrated (LARI) spectacle lens developed for an ongoing, randomized, controlled clinical trial and to support the optical approach to myopia control leveraging retinal image blur. We found that the phase modulation induced by the micro-structures of the lenslet array contributes to the increase in RMS wavefront aberrations, leading to image blur, further inspiring the novel array-patterned micro-structure design with high-order phase elements (HOPEs). The optical performance of both LARI and HOPE spectacle lenses was investigated by simulation and experiment.
Open AccessArray-Patterned Micro-Structures in Spectacle Lenses Designed for Myopia Control via Image Blur
Using micro-structure components in spectacle lenses has enabled myopia progression control in children and teenagers. However, the optical design of these spectacle lenses has never been discussed, leading to a lack of correct understanding of the underlying optical treatment principles. In this work, array-patterned hexagonal lenslets with two powers of opposite signs were proposed to construct a lenslet array-integrated (LARI) spectacle lens developed for an ongoing, randomized, controlled clinical trial and to support the optical approach to myopia control leveraging retinal image blur. We found that the phase modulation induced by the micro-structures of the lenslet array contributes to the increase in RMS wavefront aberrations, leading to image blur, further inspiring the novel array-patterned micro-structure design with high-order phase elements (HOPEs). The optical performance of both LARI and HOPE spectacle lenses was investigated by simulation and experiment.
- Open Access
- 21 June 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 890294
Normative Data and Determinants of Macular, Disc, and Peripapillary Vascular Density in Healthy Myopic Children Using Optical Coherence Tomography Angiography
Objective: To establish a normative database for the vascular density (VD) in macular, disc, and peripapillary regions in healthy myopic children and to evaluate associated ocular features with optical coherence tomography angiography (OCTA).Methods: This was an observational, prospective and cross-sectional study. 776 Chinese healthy myopic children (375 boys and 401 girls) were enrolled, mean (±SD) age 9.84 ± 1.98 (range 6–16) years. En-face angiogram OCTA was performed on 6 mm × 6 mm retinal and 4.5 mm × 4.5 mm disc regions. VD measurements in the macular retina were segmented into the four regions: superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC). Correlations between macular, disc, and peripapillary VD and possible influencing factors [age, gender, axial length (AL), spherical equivalent refraction (SER), right/left eye, and signal strength index (SSI)] were assessed by Pearson’s correlation and multivariate regression analysis.Results: For macular scans, the corrected VD in the ICP region was (48.25 ± 4.24)% for the whole macular retina. The macular ICP VD in most sections was lower than the SCP, DCP, and CC (all P < 0.001). The corrected VD in CC was (72.96 ± 4.42)% for the whole macular retina. The macular CC VD in every section was all higher than the SCP, ICP, and DCP (all P < 0.001). The size of foveal avascular zone (FAZ) and foveal VD 300 (FD-300) was 0.28 mm2± 0.10 mm2 and (58.43 ± 4.17)% respectively. For disc scans, the corrected VD was (58.04 ± 2.73)% for the whole disc area. Both AL and SER were strongly correlated with ICP, DCP, and CC VD in all regions (all P < 0.01). Larger SSI was correlated with a lower VD in the SCP and ICP, and a higher VD in DCP and CC (all P < 0.01).Conclusion: Vascular density values provide large scale normative data on macular, disc, and peripapillary vascular parameters in a large sample of healthy myopic children with OCTA measured in the four different retinal plexuses and regions. The VD in different regions had various influencing factors; mainly a close correlation with AL and SSI.
- 21 June 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 890294
Open AccessNormative Data and Determinants of Macular, Disc, and Peripapillary Vascular Density in Healthy Myopic Children Using Optical Coherence Tomography Angiography
Objective: To establish a normative database for the vascular density (VD) in macular, disc, and peripapillary regions in healthy myopic children and to evaluate associated ocular features with optical coherence tomography angiography (OCTA).Methods: This was an observational, prospective and cross-sectional study. 776 Chinese healthy myopic children (375 boys and 401 girls) were enrolled, mean (±SD) age 9.84 ± 1.98 (range 6–16) years. En-face angiogram OCTA was performed on 6 mm × 6 mm retinal and 4.5 mm × 4.5 mm disc regions. VD measurements in the macular retina were segmented into the four regions: superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC). Correlations between macular, disc, and peripapillary VD and possible influencing factors [age, gender, axial length (AL), spherical equivalent refraction (SER), right/left eye, and signal strength index (SSI)] were assessed by Pearson’s correlation and multivariate regression analysis.Results: For macular scans, the corrected VD in the ICP region was (48.25 ± 4.24)% for the whole macular retina. The macular ICP VD in most sections was lower than the SCP, DCP, and CC (all P < 0.001). The corrected VD in CC was (72.96 ± 4.42)% for the whole macular retina. The macular CC VD in every section was all higher than the SCP, ICP, and DCP (all P < 0.001). The size of foveal avascular zone (FAZ) and foveal VD 300 (FD-300) was 0.28 mm2± 0.10 mm2 and (58.43 ± 4.17)% respectively. For disc scans, the corrected VD was (58.04 ± 2.73)% for the whole disc area. Both AL and SER were strongly correlated with ICP, DCP, and CC VD in all regions (all P < 0.01). Larger SSI was correlated with a lower VD in the SCP and ICP, and a higher VD in DCP and CC (all P < 0.01).Conclusion: Vascular density values provide large scale normative data on macular, disc, and peripapillary vascular parameters in a large sample of healthy myopic children with OCTA measured in the four different retinal plexuses and regions. The VD in different regions had various influencing factors; mainly a close correlation with AL and SSI.
- Open Access
- 23 January 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (2) , 253-267
Ray-mapping based calculation of the intra-corneal wavefront and corneal ablation profile for ocular aberration corrections
We propose a ray-mapping based algorithm for the tissue ablation calculation to produce an optimum freeform anterior corneal surface that is responsible for the correction of ocular aberrations. With knowledge of the measured ocular wavefront and the anterior corneal surface, the numerical ray tracing method is used to calculate the intra-corneal wavefront and to generate the optimal corneal ablation profile determined by the accurate ray-mapping between the intra-corneal wavefront and the target ocular wavefront. This method is compared with the conventional wavefront-guided based algorithm for the ametropic eye models in theory, providing superior performance both in the aberration-free correction and the aberration selective correction.
- 23 January 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (2) , 253-267
Open AccessRay-mapping based calculation of the intra-corneal wavefront and corneal ablation profile for ocular aberration corrections
We propose a ray-mapping based algorithm for the tissue ablation calculation to produce an optimum freeform anterior corneal surface that is responsible for the correction of ocular aberrations. With knowledge of the measured ocular wavefront and the anterior corneal surface, the numerical ray tracing method is used to calculate the intra-corneal wavefront and to generate the optimal corneal ablation profile determined by the accurate ray-mapping between the intra-corneal wavefront and the target ocular wavefront. This method is compared with the conventional wavefront-guided based algorithm for the ametropic eye models in theory, providing superior performance both in the aberration-free correction and the aberration selective correction.
- Open Access
- 15 March 2018
- Published by Springer Nature in Eye and Vision
- Vol. 5 (1) , 1-11
Influence of overnight orthokeratology lens fitting decentration on corneal topography reshaping
This retrospective study was designed to investigate the sole influence of orthokeratology (OK) lens fitting decentration on the Zernike coefficients of the reshaped anterior corneal surface. This study comprised a review of 106 right eyes and measurements of corneal topography both before OK and at 1-month follow-up visit. A routine was designed to calculate local corneal surface astigmatism and assist the determination of OK lens fitting decentration from pupil center. The pupil-centered corneal Zernike coefficients of baseline (PCCB) and post-treatment (PCCP) were calculated. Meanwhile, the OK-lens-centered corneal Zernike coefficients of post-treatment (OCCP) were also calculated and considered as the presumptive ideal fitting group without decentration. Relationships between lens fitting decentration and the change of Zernike coefficients including (PCCP − PCCB) and (PCCP − OCCP) were analyzed. Patients with a mean age of 11 ± 2.36 years old had an average spherical equivalent refractive error of −3.52 ± 1.06 D before OK. One month after treatment, OK lens fitting decentration from pupil center was 0.68 ± 0.35 mm. RMS of 3rd-order (P < 0.05), RMS of 4th-order (P < 0.001) and RMS of total high order (P < 0.001) corneal Zernike coefficients were increased in PCCP by comparing with OCCP, which was solely caused by lens fitting decentration. Nevertheless, no significant difference was observed in $$ {C}_2^0 $$ (P > 0.05). For the high order corneal Zernike coefficients in (PCCP – OCCP), radial distance of decentration was correlated with $$ {C}_3^{-1} $$ (r = −0.296, P < 0.05), $$ {C}_3^1 $$ (r = −0.396, P < 0.001), and $$ {C}_4^0 $$ (r = 0.449, P < 0.001), horizontal decentration was significantly correlated with $$ {C}_3^1 $$ (r = 0.901, P < 0.001) and $$ {C}_5^1 $$ (r = 0.340, P < 0.001), and vertical decentration was significantly correlated with $$ {C}_3^{-1} $$ (r = 0.904, P < 0.001). OK lens fitting decentration within 1.5 mm hardly influenced the change of corneal spherical power for myopia correction, but significantly induced additional corneal high order Zernike coefficients including $$ {C}_3^{-1} $$ , $$ {C}_3^1 $$ , $$ {C}_4^0 $$ , and $$ {C}_5^1 $$ .- 15 March 2018
- Published by Springer Nature in Eye and Vision
- Vol. 5 (1) , 1-11
Open AccessInfluence of overnight orthokeratology lens fitting decentration on corneal topography reshaping
This retrospective study was designed to investigate the sole influence of orthokeratology (OK) lens fitting decentration on the Zernike coefficients of the reshaped anterior corneal surface. This study comprised a review of 106 right eyes and measurements of corneal topography both before OK and at 1-month follow-up visit. A routine was designed to calculate local corneal surface astigmatism and assist the determination of OK lens fitting decentration from pupil center. The pupil-centered corneal Zernike coefficients of baseline (PCCB) and post-treatment (PCCP) were calculated. Meanwhile, the OK-lens-centered corneal Zernike coefficients of post-treatment (OCCP) were also calculated and considered as the presumptive ideal fitting group without decentration. Relationships between lens fitting decentration and the change of Zernike coefficients including (PCCP − PCCB) and (PCCP − OCCP) were analyzed. Patients with a mean age of 11 ± 2.36 years old had an average spherical equivalent refractive error of −3.52 ± 1.06 D before OK. One month after treatment, OK lens fitting decentration from pupil center was 0.68 ± 0.35 mm. RMS of 3rd-order (P < 0.05), RMS of 4th-order (P < 0.001) and RMS of total high order (P < 0.001) corneal Zernike coefficients were increased in PCCP by comparing with OCCP, which was solely caused by lens fitting decentration. Nevertheless, no significant difference was observed in $$ {C}_2^0 $$ (P > 0.05). For the high order corneal Zernike coefficients in (PCCP – OCCP), radial distance of decentration was correlated with $$ {C}_3^{-1} $$ (r = −0.296, P < 0.05), $$ {C}_3^1 $$ (r = −0.396, P < 0.001), and $$ {C}_4^0 $$ (r = 0.449, P < 0.001), horizontal decentration was significantly correlated with $$ {C}_3^1 $$ (r = 0.901, P < 0.001) and $$ {C}_5^1 $$ (r = 0.340, P < 0.001), and vertical decentration was significantly correlated with $$ {C}_3^{-1} $$ (r = 0.904, P < 0.001). OK lens fitting decentration within 1.5 mm hardly influenced the change of corneal spherical power for myopia correction, but significantly induced additional corneal high order Zernike coefficients including $$ {C}_3^{-1} $$ , $$ {C}_3^1 $$ , $$ {C}_4^0 $$ , and $$ {C}_5^1 $$ . - 1 January 2018
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 16 (11) , 113302
Customized design and efficient machining of astigmatism-minimized progressive addition lens
Astigmatism is inevitable and inherent to progressive addition lenses (PALs), which are typically distributed in the lateral areas on both sides of the progressive corridor. In this study, we took into account the spectacle frame for the customized freeform PAL design with the variational-difference numerical approach. The PAL surface with minimized astigmatism, approximately equal to 84% of the added power, was numerically resolved without expending the zone for clear vision. We validated our approach by experimentally demonstrating the procedure from tool path generation to surface power measurement, thus providing an efficient solution to the personalization of astigmatism-minimized PAL design and manufacture.
- 1 January 2018
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 16 (11) , 113302
Customized design and efficient machining of astigmatism-minimized progressive addition lens
Astigmatism is inevitable and inherent to progressive addition lenses (PALs), which are typically distributed in the lateral areas on both sides of the progressive corridor. In this study, we took into account the spectacle frame for the customized freeform PAL design with the variational-difference numerical approach. The PAL surface with minimized astigmatism, approximately equal to 84% of the added power, was numerically resolved without expending the zone for clear vision. We validated our approach by experimentally demonstrating the procedure from tool path generation to surface power measurement, thus providing an efficient solution to the personalization of astigmatism-minimized PAL design and manufacture.