Weihong Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weihong Qiu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Junyan Cao
Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, Sun Yat-sen University, Guangzhou, China
2 shared publications - Zhaocong Chen
Department of Rehabilitation Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Sun Yat-sen University, Guangzhou, China
2 shared publications Guorong Qiu
A Department of Rehabilitation Medicine , The Third Affiliated Hospital of Sun Yat-sen University , Guangzhou , China
1 shared publication- Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
1 shared publication Hongli Guan
A Department of Rehabilitation Medicine , The Third Affiliated Hospital of Sun Yat-sen University , Guangzhou , China
1 shared publicationHuixiang Wu
A Department of Rehabilitation Medicine , The Third Affiliated Hospital of Sun Yat-sen University , Guangzhou , China
1 shared publication
Latest Publications
- Open Access
- 5 February 2022
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 19 (1) , 1-11
Reliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients
Background: To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. Methods: Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis. Results: The intra- (0.791 95% CI 0.432–0.932) and interobserver (0.751 95% CI 0.382–0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = − 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%. Conclusion: 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity.
- 5 February 2022
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 19 (1) , 1-11
Open AccessReliability and diagnostic accuracy of corrected slack angle derived from 2D-SWE in quantitating muscle spasticity of stroke patients
Background: To explore the feasibility of corrected slack angle acquired from two-dimensional shear wave elastography (2D-SWE) for quantitating the spasticity of medial gastrocnemius (MG) in stroke patients. Methods: Consecutive stroke patients with spastic MG and matched healthy controls were recruited. Intra- and interobserver reliability of 2D-SWE measurement were evaluated, and the correlation between corrected slack angle and modified Ashworth scale (MAS) score was examined. The corrected slack angle before and after botulinum toxin A (BoNT-A) injection was compared and its diagnostic performance in classifying the severity of spasticity were assessed with receiver operating characteristic (ROC) curve analysis. Results: The intra- (0.791 95% CI 0.432–0.932) and interobserver (0.751 95% CI 0.382–0.916) reliability of slack angle acquired with 2D-SWE were good. Significant correlation was found between corrected slack angle and MAS score (R = − 0.849, p < 0.001). The corrected slack angle increased after BoNT-A injection. The cutoff value of MAS ≥ 3 had the highest sensitivity (100%) and specificity (93.33%). The positive predictive value (PPV) for classification of MAS ≥ 1+ and the negative predictive value (NPV) for classification of MAS ≥ 3 were greater than 90%. Conclusion: 2D-SWE was a reliable method to quantitate the post-stroke spasticity. The corrected slack angle had advantage in classifying the severity of spasticity, especially in early identification of mild spasticity and confirmation of severe spasticity.
- Open Access
- 4 January 2022
- Published by Springer Nature in BMC Psychiatry
- Vol. 22 (1) , 1-10
The association between serum albumin and depression in chronic liver disease may differ by liver histology
Background: There are conflicting results regarding the association between chronic liver disease (CLD) and depression and the underlying biological mechanisms are lack of investigation. To address the impact of depression and its effects on the management of CLD, its biological marker is critical to be identified. The present study explored the association between serum albumin and depression in CLD patients and whether the association varied in different liver histological stages. Methods: Based on the United States National Health and Nutrition Examination Survey 2017–2018, the data of serum albumin and depressive symptoms from 627 participants with CLD were used. Depression symptoms were assessed with the nine-item Patient Health Questionnaire (PHQ-9). We used multivariate linear regression to evaluate the association between serum albumin and PHQ-9 scores. Stratified analysis was performed according to the liver histology examined by vibration controlled transient elastography. Results: Serum albumin level was inversely associated with PHQ-9 scores in the multivariate regression model after adjusting for mainly potential confounders (β = − 1.113, 95% CI: − 2.065 to − 0.162, P = 0.0221). In the subgroup analysis stratified by gender, controlled attenuation parameter (CAP) and liver stiffness measurement (LSM), the inverse association remained significant in female (β = − 2.002, 95% CI: − 3.515 to − 0.489, P = 0.0100), patients with CAP < 274 dB/m (β = − 2.215, 95% CI: − 3.621 to − 0.808, P = 0.0023) and patients with LSM ≥8.2 kPa (β = − 4.074, 95% CI: − 6.237 to − 1.911, P = 0.0003). Moreover, the association was much stronger when the serum albumin was higher than 3.4 g/dL among patients with LSM ≥8.2 kPa (β = − 4.835, 95% CI: − 7.137 to − 2.533, P < 0.0001). Conclusion: Our study revealed an inverse association between serum albumin and depression in CLD patients and this association differed according to liver histological changes. Serum albumin could be a warning marker for depressive symptoms in CLD patients. It is essential for taking corresponding intervention strategies.
- 4 January 2022
- Published by Springer Nature in BMC Psychiatry
- Vol. 22 (1) , 1-10
Open AccessThe association between serum albumin and depression in chronic liver disease may differ by liver histology
Background: There are conflicting results regarding the association between chronic liver disease (CLD) and depression and the underlying biological mechanisms are lack of investigation. To address the impact of depression and its effects on the management of CLD, its biological marker is critical to be identified. The present study explored the association between serum albumin and depression in CLD patients and whether the association varied in different liver histological stages. Methods: Based on the United States National Health and Nutrition Examination Survey 2017–2018, the data of serum albumin and depressive symptoms from 627 participants with CLD were used. Depression symptoms were assessed with the nine-item Patient Health Questionnaire (PHQ-9). We used multivariate linear regression to evaluate the association between serum albumin and PHQ-9 scores. Stratified analysis was performed according to the liver histology examined by vibration controlled transient elastography. Results: Serum albumin level was inversely associated with PHQ-9 scores in the multivariate regression model after adjusting for mainly potential confounders (β = − 1.113, 95% CI: − 2.065 to − 0.162, P = 0.0221). In the subgroup analysis stratified by gender, controlled attenuation parameter (CAP) and liver stiffness measurement (LSM), the inverse association remained significant in female (β = − 2.002, 95% CI: − 3.515 to − 0.489, P = 0.0100), patients with CAP < 274 dB/m (β = − 2.215, 95% CI: − 3.621 to − 0.808, P = 0.0023) and patients with LSM ≥8.2 kPa (β = − 4.074, 95% CI: − 6.237 to − 1.911, P = 0.0003). Moreover, the association was much stronger when the serum albumin was higher than 3.4 g/dL among patients with LSM ≥8.2 kPa (β = − 4.835, 95% CI: − 7.137 to − 2.533, P < 0.0001). Conclusion: Our study revealed an inverse association between serum albumin and depression in CLD patients and this association differed according to liver histological changes. Serum albumin could be a warning marker for depressive symptoms in CLD patients. It is essential for taking corresponding intervention strategies.
- 19 November 2018
- Published by Taylor & Francis in Topics in Stroke Rehabilitation
- Vol. 26 (2) , 106-112
Psychometric properties of the Chinese-version Stroke and Aphasia Quality of Life Scale 39-generic version (SAQOL-39g)
Background and purpose: Aphasia is a common outcome of stroke affecting one-third of the post-stroke population in China. While the quality of life (QOL) may be affected, care is often inadequately guided due to lack of validated measure for Chinese population with stroke-induced aphasia. This study aimed to develop a Chinese-version of the Stroke and Aphasia Quality of Life-39 generic version (SAQOL-39g) and evaluate its feasibility, reliability, and validity in Chinese patients with stroke-induced aphasia. Methods: The process of translation and adaptation suggested by WHO was used to develop the Chinese-version of SAQOL-39. We evaluated the feasibility, reliability, and validity of the scale in 84 aphasia patients and their proxies by assessing the internal consistency of the test items, test–retest consistency, and the structural validity of data. Results: The self-report and the proxy-report form were completed within 21.4 and 13.3 min on average, respectively. Physical, communication, and psychological subdomains were extracted as three common factors. The Cronbach’s alpha coefficients of overall domain and subdomains for both forms ranged from 0.879 to 0.950, indicating high internal consistency. The intraclass correlation coefficients ranged from 0.804 to 0.987 for overall domain and subdomains of the forms. No significant difference was found between two forms. Conclusions: The Chinese-version SAQOL-39g has excellent reliability, validity, and feasibility for measuring the QOL of Chinese post-stroke aphasia patients. The consistency between self-report and proxy-report forms was good, implying that the proxy-report form can be used to assess the QOL of post-stroke aphasia patients.
- 19 November 2018
- Published by Taylor & Francis in Topics in Stroke Rehabilitation
- Vol. 26 (2) , 106-112
Psychometric properties of the Chinese-version Stroke and Aphasia Quality of Life Scale 39-generic version (SAQOL-39g)
Background and purpose: Aphasia is a common outcome of stroke affecting one-third of the post-stroke population in China. While the quality of life (QOL) may be affected, care is often inadequately guided due to lack of validated measure for Chinese population with stroke-induced aphasia. This study aimed to develop a Chinese-version of the Stroke and Aphasia Quality of Life-39 generic version (SAQOL-39g) and evaluate its feasibility, reliability, and validity in Chinese patients with stroke-induced aphasia. Methods: The process of translation and adaptation suggested by WHO was used to develop the Chinese-version of SAQOL-39. We evaluated the feasibility, reliability, and validity of the scale in 84 aphasia patients and their proxies by assessing the internal consistency of the test items, test–retest consistency, and the structural validity of data. Results: The self-report and the proxy-report form were completed within 21.4 and 13.3 min on average, respectively. Physical, communication, and psychological subdomains were extracted as three common factors. The Cronbach’s alpha coefficients of overall domain and subdomains for both forms ranged from 0.879 to 0.950, indicating high internal consistency. The intraclass correlation coefficients ranged from 0.804 to 0.987 for overall domain and subdomains of the forms. No significant difference was found between two forms. Conclusions: The Chinese-version SAQOL-39g has excellent reliability, validity, and feasibility for measuring the QOL of Chinese post-stroke aphasia patients. The consistency between self-report and proxy-report forms was good, implying that the proxy-report form can be used to assess the QOL of post-stroke aphasia patients.