Andreas Chwala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas Chwala has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Ronny Stolz
Leibniz Institute of Photonic Technology
6 shared publications - Matthias Schmelz
Leibniz-Institute of Photonic Technologies, Jena, Germany
2 shared publications Vyacheslav Zakosarenko
Quantum Systems, Leibniz Institute of Photonic Technology, Jena, Thüringen, GERMANY
2 shared publicationsA. Krüger
Supracon AG, An der Lehmgrube 11, Jena D-07751, Germany
1 shared publicationAndré Krüger
Supracon AG, Jena, Germany
1 shared publication- Des Fitzgerald
Cardiff University
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 11 February 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (2) , 024034
Integrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
We present a portable optically pumped magnetometer instrument for ultrasensitive measurements within the Earth’s magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift dispersed mode. It is connected to a compact, battery-driven electronics module by a flexible cable. We briefly review the working principles of the device and detail the realization of both the sensor head and electronics. We show shielded and unshielded measurements within a static magnetic field amplitude of , demonstrating a noise level of the sensor system down to and a sensor bandwidth of several 100 Hz. In a detailed analysis of sensor noise, we reveal the system to be limited by technical sources with straightforward strategies for further improvement toward its fundamental noise limit of . We assess the parameters defining the sensor bandwidth by theoretical modeling based on the Bloch equations. Finally, we compare our sensors’ performance to a commercial superconducting quantum interference device system in a measurement environment typical for geomagnetic observatory practice and geomagnetic prospection.- 11 February 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (2) , 024034
Top Cited PapersOpen AccessIntegrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
We present a portable optically pumped magnetometer instrument for ultrasensitive measurements within the Earth’s magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift dispersed mode. It is connected to a compact, battery-driven electronics module by a flexible cable. We briefly review the working principles of the device and detail the realization of both the sensor head and electronics. We show shielded and unshielded measurements within a static magnetic field amplitude of , demonstrating a noise level of the sensor system down to and a sensor bandwidth of several 100 Hz. In a detailed analysis of sensor noise, we reveal the system to be limited by technical sources with straightforward strategies for further improvement toward its fundamental noise limit of . We assess the parameters defining the sensor bandwidth by theoretical modeling based on the Bloch equations. Finally, we compare our sensors’ performance to a commercial superconducting quantum interference device system in a measurement environment typical for geomagnetic observatory practice and geomagnetic prospection. - 10 March 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (4) , 045015
Magnetic background field-tolerant SQIF-based current sensors
We report on the development of magnetic background field-tolerant superconducting quantum interference filter (SQIF) based on low-capacitance sub-micrometer sized cross-type Josephson junctions either as current sensing amplifiers—even on chip—for advanced superconducting quantum interference device (SQUID) readout circuits or as magnetic field sensor in flux transformer configuration especially for geophysical measurement systems. Their very small parasitic magnetic sensitive areas enable them to operate in the Earth magnetic field and allow for magnetically unshielded cool-down. The careful consideration of magnetic sensitive areas inside each SQUID in the SQIF in all three dimensions result in developed SQIFs with 28 SQUIDs in series exhibiting large voltage swing and transfer function of more than 2 mV and 500 V A − 1 , respectively. We report on the electrical parameters and field stability as well as on the noise performance of the devices under investigation. SQIFs and devices with additional on-chip flux-transformers show input referred current noise levels of 5.9 and 1.1 pA H z − 1 / 2 , respectively. We furthermore demonstrate their potential as SQIF-based magnetometers using them in addition with thin-film pickup loops resulting in a white magnetic field noise of 1.6 f T H z − 1 / 2 . The implemented SQIFs are thus highly compatible with state-of-the-art single SQUID-devices offering beneficial features such as a unique working point, making them excellent suited for implementation of e.g. geophysical instruments.
- 10 March 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (4) , 045015
Magnetic background field-tolerant SQIF-based current sensors
We report on the development of magnetic background field-tolerant superconducting quantum interference filter (SQIF) based on low-capacitance sub-micrometer sized cross-type Josephson junctions either as current sensing amplifiers—even on chip—for advanced superconducting quantum interference device (SQUID) readout circuits or as magnetic field sensor in flux transformer configuration especially for geophysical measurement systems. Their very small parasitic magnetic sensitive areas enable them to operate in the Earth magnetic field and allow for magnetically unshielded cool-down. The careful consideration of magnetic sensitive areas inside each SQUID in the SQIF in all three dimensions result in developed SQIFs with 28 SQUIDs in series exhibiting large voltage swing and transfer function of more than 2 mV and 500 V A − 1 , respectively. We report on the electrical parameters and field stability as well as on the noise performance of the devices under investigation. SQIFs and devices with additional on-chip flux-transformers show input referred current noise levels of 5.9 and 1.1 pA H z − 1 / 2 , respectively. We furthermore demonstrate their potential as SQIF-based magnetometers using them in addition with thin-film pickup loops resulting in a white magnetic field noise of 1.6 f T H z − 1 / 2 . The implemented SQIFs are thus highly compatible with state-of-the-art single SQUID-devices offering beneficial features such as a unique working point, making them excellent suited for implementation of e.g. geophysical instruments.
- 7 January 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (2) , 024003
Underwater operation of a full tensor SQUID gradiometer system
For the first time a mobile underwater full tensor magnetic gradiometer (FTMG) system based on low- T c superconducting quantum interference devices (SQUIDs) has been deployed in order to scan the sea floor for magnetized targets. The application is mainly focused on waste deposits and unexploded ordnance (UXO), but could also include shallow geological features as well as archaeological remains. The main methods for detection and localisation of underwater UXO and waste deposits are side sonar scanning and magnetic mapping. While modern sonar scanners can achieve a very high spatial resolution and long detection range, they still have problems detecting targets under cover—for magnetic sensors a layer of non-magnetic sand or ooze does usually not have an effect on the signal apart from an increased distance. In this paper we discuss the setup of the mobile underwater FTMG SQUID system, its challenges and main performance features. It also illustrates its detection and localization capabilities in tests on known magnetic targets.
- 7 January 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (2) , 024003
Underwater operation of a full tensor SQUID gradiometer system
For the first time a mobile underwater full tensor magnetic gradiometer (FTMG) system based on low- T c superconducting quantum interference devices (SQUIDs) has been deployed in order to scan the sea floor for magnetized targets. The application is mainly focused on waste deposits and unexploded ordnance (UXO), but could also include shallow geological features as well as archaeological remains. The main methods for detection and localisation of underwater UXO and waste deposits are side sonar scanning and magnetic mapping. While modern sonar scanners can achieve a very high spatial resolution and long detection range, they still have problems detecting targets under cover—for magnetic sensors a layer of non-magnetic sand or ooze does usually not have an effect on the signal apart from an increased distance. In this paper we discuss the setup of the mobile underwater FTMG SQUID system, its challenges and main performance features. It also illustrates its detection and localization capabilities in tests on known magnetic targets.
- 28 September 2018
- Published by Society of Exploration Geophysicists in Geophysics
- Vol. 83 (6) , E371-E383
Capability of low-temperature SQUID for transient electromagnetics under anthropogenic noise conditions
Transient electromagnetics (TEM) is a well-established method for mineral, groundwater, and geothermal exploration. Superconducting quantum interference device (SQUID)-based magnetic-field receivers used for TEM have quantitative advantages and higher sensitivity compared with commonly used induction coils. Special applications are deep soundings with target depths >1 km and settings with conductive overburden. However, SQUIDs have rarely been applied for TEM measurements in environments with significant anthropogenic noise. We compared a low-temperature SQUID with a commercially available induction coil in an area affected by anthropogenic noise. We acquired four fixed-loop data sets with totally 61 receiver stations close to Bad Frankenhausen, Germany. The high sensitivity of the SQUID enables low noise levels, which lead to longer high-quality transient data compared with the induction coil. The effect of anthropogenic and natural noise sources is more critical for the coil than for the SQUID data. In the vicinity of the transmitter loop, systematic distortion of the coil signals occurs at early times, most probably caused by sferic interferences. We have developed 1D inversion results of both receivers that matched well in general. However, the SQUID-based models were more consistent and showed greater depths of investigation. This led to a superior resolution of deeper layers and even enabled a potential detection of thin conducting targets at up to a 500 m depth. Moreover, we find that the SQUID data inversion revealed multidimensional effects within the conductive overburden. In this regard, we applied forward modeling to analyze systematic differences between inversion results of SQUID and coil data. We determine that low-temperature SQUIDs have the potential to significantly improve the reliability of subsurface models in suburban environments. Nevertheless, we recommend combined application of both types of receivers.
- 28 September 2018
- Published by Society of Exploration Geophysicists in Geophysics
- Vol. 83 (6) , E371-E383
Capability of low-temperature SQUID for transient electromagnetics under anthropogenic noise conditions
Transient electromagnetics (TEM) is a well-established method for mineral, groundwater, and geothermal exploration. Superconducting quantum interference device (SQUID)-based magnetic-field receivers used for TEM have quantitative advantages and higher sensitivity compared with commonly used induction coils. Special applications are deep soundings with target depths >1 km and settings with conductive overburden. However, SQUIDs have rarely been applied for TEM measurements in environments with significant anthropogenic noise. We compared a low-temperature SQUID with a commercially available induction coil in an area affected by anthropogenic noise. We acquired four fixed-loop data sets with totally 61 receiver stations close to Bad Frankenhausen, Germany. The high sensitivity of the SQUID enables low noise levels, which lead to longer high-quality transient data compared with the induction coil. The effect of anthropogenic and natural noise sources is more critical for the coil than for the SQUID data. In the vicinity of the transmitter loop, systematic distortion of the coil signals occurs at early times, most probably caused by sferic interferences. We have developed 1D inversion results of both receivers that matched well in general. However, the SQUID-based models were more consistent and showed greater depths of investigation. This led to a superior resolution of deeper layers and even enabled a potential detection of thin conducting targets at up to a 500 m depth. Moreover, we find that the SQUID data inversion revealed multidimensional effects within the conductive overburden. In this regard, we applied forward modeling to analyze systematic differences between inversion results of SQUID and coil data. We determine that low-temperature SQUIDs have the potential to significantly improve the reliability of subsurface models in suburban environments. Nevertheless, we recommend combined application of both types of receivers.
- 27 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (7) , 1-5
Advanced HTS DC SQUIDs with Step-Edge Josephson Junctions for Geophysical Applications
For ground-based electromagnetic methods in geophysics dc superconducting quantum interference devices based on high-temperature superconductors are well suited as magnetic field sensors. Therefore, we introduce in this paper an advanced fabrication technology for high-temperature superconducting dc SQUIDs based on step-edge Josephson junctions. The dc SQUIDs are prepared on structured magnesium-oxide substrates. A trilayer of YBa 2 Cu 3 O 7-x /SrTiO 3 /YBa 2 Cu 3 O 7-x is deposited by pulsed laser deposition and structured with ion beam etching. The galvanometer-type design consists of four different dc SQUIDs directly coupled to a pickup loop. They exhibit large I c R n products and a voltage swing of more than 30 μV. The magnetic field noise amounts to about 20 fT/Hz 1/2 and 35 fT/Hz 1/2 for the white noise region as well as 25 fT/Hz 1/2 and 100 fT/Hz 1/2 at 100 Hz for ac-bias and dc-bias SQUID electronics, respectively. The advanced fabrication process thus enables to produce HTS dc SQUIDs intended for the use in geophysical applications with high throughput.
- 27 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (7) , 1-5
Advanced HTS DC SQUIDs with Step-Edge Josephson Junctions for Geophysical Applications
For ground-based electromagnetic methods in geophysics dc superconducting quantum interference devices based on high-temperature superconductors are well suited as magnetic field sensors. Therefore, we introduce in this paper an advanced fabrication technology for high-temperature superconducting dc SQUIDs based on step-edge Josephson junctions. The dc SQUIDs are prepared on structured magnesium-oxide substrates. A trilayer of YBa 2 Cu 3 O 7-x /SrTiO 3 /YBa 2 Cu 3 O 7-x is deposited by pulsed laser deposition and structured with ion beam etching. The galvanometer-type design consists of four different dc SQUIDs directly coupled to a pickup loop. They exhibit large I c R n products and a voltage swing of more than 30 μV. The magnetic field noise amounts to about 20 fT/Hz 1/2 and 35 fT/Hz 1/2 for the white noise region as well as 25 fT/Hz 1/2 and 100 fT/Hz 1/2 at 100 Hz for ac-bias and dc-bias SQUID electronics, respectively. The advanced fabrication process thus enables to produce HTS dc SQUIDs intended for the use in geophysical applications with high throughput.
- Open Access
- 1 December 2010
- Published by Taylor & Francis in ASEG Extended Abstracts
- Vol. 2010 (1) , 1-4
Compensation of the full magnetic tensor gradient signal
In recent developments a full tensor magnetic gradient system has been deployed in South Africa. The instrument is made by IPHT (Institute of Photonic Technology, Jena, Germany) and flown by helico...
- 1 December 2010
- Published by Taylor & Francis in ASEG Extended Abstracts
- Vol. 2010 (1) , 1-4
Open AccessCompensation of the full magnetic tensor gradient signal
In recent developments a full tensor magnetic gradient system has been deployed in South Africa. The instrument is made by IPHT (Institute of Photonic Technology, Jena, Germany) and flown by helico...