Hua Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hua Chen has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Leyi Cai
Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, No.109, XueYuan West Road, Luheng District, Wenzhou, Zhejiang Province, 325000, China
7 shared publications - Linzhen Xie
Department of Orthopedics, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
4 shared publications - Wenhao Zheng
Department of Orthopedics, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China
3 shared publications - Jinwu Wang
Department of Bone and Soft Tissue Tumors, Tianjin Medical University Cancer Institute and Hospital, Tianjin, P. R. China
2 shared publications - Qingqing Wang
Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China
2 shared publications - Te Wang
Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China
2 shared publications
Latest Publications
Surgical treatment of fracture-related infections of the calcaneus with relevant soft-tissue defects
- 1 January 2021
- Vol. 13 (6) , 7422-7424
An injectable liposome for sustained release of tanshinone IIA to the treatment of acute blunt muscle injury by augmenting autophagy and alleviating oxidative stress (vol 12, pg 4189, 2020)
[This corrects the article on p. 4189 in vol. 12, PMID: 32913497.].
- 1 January 2021
- Vol. 13 (6) , 7422-7424
An injectable liposome for sustained release of tanshinone IIA to the treatment of acute blunt muscle injury by augmenting autophagy and alleviating oxidative stress (vol 12, pg 4189, 2020)
[This corrects the article on p. 4189 in vol. 12, PMID: 32913497.].
- 1 November 2020
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 47 (6) , 1699-1712
Comparison of the feasibility of 3D printing technology in the treatment of pelvic fractures: a systematic review and meta-analysis of randomized controlled trials and prospective comparative studies
Purpose The objective of this meta-analysis was to assess the influence of 3D printing technology on the open reduction and internal fixation (ORIF) of pelvic fractures from current randomized controlled trials and prospective comparative studies. Methods In this meta-analysis, we conducted electronic searches of Pubmed, Embase, Cochrane library, Web of Science and CNKI up to February 2020. We collected clinical controlled trials using 3D printing-assisted surgery and traditional techniques to assist in pelvic fractures, evaluating the quality of the included studies and extracting data. The data of operation time, blood loss, follow-up function (Majeed function score), quality of fracture reduction (Matta score) and complications (infection, screw loosening, pelvic instability, venous thromboembolism, sacral nerve injury) were extracted. Stata 12.0 software was used for our meta-analysis. Results Five RCTs and 2 prospective comparative studies met our inclusion criteria with 174 patients in the 3D printing group and 174 patients in the conventional group. There were significant differences in operation time [SMD = − 2.03], intraoperative blood loss [SMD = − 1.66] and postoperative complications [RR = 0.17] between the 3D group and conventional group. And the excellent and good rate of pelvic fracture reduction in the 3D group [RR = 1.32], the excellent and good rate of pelvic function [RR = 1.29] was superior to the conventional group. Conclusions The 3D group showed shorter operation time, less intraoperative blood loss, less complications, better quality of fracture reduction and fast function recovery. Therefore, compared with conventional ORIF, ORIF assisted by 3D printing technology should be a more appropriate treatment of pelvic fractures.
- 1 November 2020
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 47 (6) , 1699-1712
Comparison of the feasibility of 3D printing technology in the treatment of pelvic fractures: a systematic review and meta-analysis of randomized controlled trials and prospective comparative studies
Purpose The objective of this meta-analysis was to assess the influence of 3D printing technology on the open reduction and internal fixation (ORIF) of pelvic fractures from current randomized controlled trials and prospective comparative studies. Methods In this meta-analysis, we conducted electronic searches of Pubmed, Embase, Cochrane library, Web of Science and CNKI up to February 2020. We collected clinical controlled trials using 3D printing-assisted surgery and traditional techniques to assist in pelvic fractures, evaluating the quality of the included studies and extracting data. The data of operation time, blood loss, follow-up function (Majeed function score), quality of fracture reduction (Matta score) and complications (infection, screw loosening, pelvic instability, venous thromboembolism, sacral nerve injury) were extracted. Stata 12.0 software was used for our meta-analysis. Results Five RCTs and 2 prospective comparative studies met our inclusion criteria with 174 patients in the 3D printing group and 174 patients in the conventional group. There were significant differences in operation time [SMD = − 2.03], intraoperative blood loss [SMD = − 1.66] and postoperative complications [RR = 0.17] between the 3D group and conventional group. And the excellent and good rate of pelvic fracture reduction in the 3D group [RR = 1.32], the excellent and good rate of pelvic function [RR = 1.29] was superior to the conventional group. Conclusions The 3D group showed shorter operation time, less intraoperative blood loss, less complications, better quality of fracture reduction and fast function recovery. Therefore, compared with conventional ORIF, ORIF assisted by 3D printing technology should be a more appropriate treatment of pelvic fractures.
- 7 April 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1110) , 20191030
Comparison of radiographs and CT features between posterior Pilon fracture and posterior malleolus fracture: a retrospective cohort study
Objectives: This study explored the morphological differences between posterior Pilon fracture and posterior malleolus fracture from radiographs and CT to provide detail for diagnosis and treatment of them. Methods: Radiographs and CT imaging data of 174 patients with distal posterior tibial fractures who were treated from January 2013 to January 2019 were retrospectively analyzed. Based on the operation and imaging examination, the fractures were classified into posterior Pilon fractures and posterior malleolus fractures. Radiographic parameters including the width, height, depth, α angle, β angle, γ angle, fragment area ratio 1 (FAR1), δ angle and fragment area ratio 2 (FAR2) of ankle mortise were measured. Results: There were 96 posterior Pilon fractures (Type I: 30, Type II: 22 and Type III: 44) and 78 posterior malleolus fractures (Type I: 40 and Type II: 38). The ankle depth, α angle, γ angle, FAR1 and FAR2 of posterior Pilon fractures were larger than these of posterior malleolus fractures (p < 0.05). In addition, FAR1 and FAR2 of Type II and Type III posterior Pilon fractures were significantly larger than these of Type I (p < 0.05). FAR1 and FAR2 of Type I posterior malleolus fractures were significantly smaller than these of Type II (p < 0.05). Conclusion: Radiographs combined with CT analysis is an effective method to accurately distinguish morphological features between posterior Pilon fracture and posterior malleolus fracture. Advances in knowledge: Radiographs combined with CT distinguished the fracture of posterior malleolus and posterior Pilon rapidly and accurately, instead of operation.
- 7 April 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1110) , 20191030
Comparison of radiographs and CT features between posterior Pilon fracture and posterior malleolus fracture: a retrospective cohort study
Objectives: This study explored the morphological differences between posterior Pilon fracture and posterior malleolus fracture from radiographs and CT to provide detail for diagnosis and treatment of them. Methods: Radiographs and CT imaging data of 174 patients with distal posterior tibial fractures who were treated from January 2013 to January 2019 were retrospectively analyzed. Based on the operation and imaging examination, the fractures were classified into posterior Pilon fractures and posterior malleolus fractures. Radiographic parameters including the width, height, depth, α angle, β angle, γ angle, fragment area ratio 1 (FAR1), δ angle and fragment area ratio 2 (FAR2) of ankle mortise were measured. Results: There were 96 posterior Pilon fractures (Type I: 30, Type II: 22 and Type III: 44) and 78 posterior malleolus fractures (Type I: 40 and Type II: 38). The ankle depth, α angle, γ angle, FAR1 and FAR2 of posterior Pilon fractures were larger than these of posterior malleolus fractures (p < 0.05). In addition, FAR1 and FAR2 of Type II and Type III posterior Pilon fractures were significantly larger than these of Type I (p < 0.05). FAR1 and FAR2 of Type I posterior malleolus fractures were significantly smaller than these of Type II (p < 0.05). Conclusion: Radiographs combined with CT analysis is an effective method to accurately distinguish morphological features between posterior Pilon fracture and posterior malleolus fracture. Advances in knowledge: Radiographs combined with CT distinguished the fracture of posterior malleolus and posterior Pilon rapidly and accurately, instead of operation.
- 1 April 2019
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 105 (2) , 307-316
Deltoid-split approach versus deltopectoral approach for proximal humerus fractures: A systematic review and meta-analysis
- 1 April 2019
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 105 (2) , 307-316
Deltoid-split approach versus deltopectoral approach for proximal humerus fractures: A systematic review and meta-analysis
- 1 December 2018
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 60, 137-140
Management of distal radius fracture: A comparison of actual and theoretical treatments
The objective of this study was to explore whether there were any differences between the theoretical operative treatment of distal radius fractures according to AAOS guideline on basis of measurement of radiographs and the treatment they actually received in our institution. From April 2015 to February 2018, a total of 693 patients with 697 fresh close adult distal radius fractures were evaluated retrospectively. Fractures were respectively grouped into categories by AAOS criterion and actually treatment. After gleaning demographic information and measuring radiographic items, all results were put into a database. Single factors analysis, Chi-square test and further logistic regression analysis were performed to determine correlations between actual and theoretical treatments. In all 240 fractures fulfilled at least one AAOS criterion for surgery, only 61 fractures actually received operation. And in the conservative group recommended by AAOS, 52 of 457 fractures actually were proceeded with surgery. There were slight correlation between AAOS guideline and actually operation (Phi = 0.181). From multivariable logistic regression analysis, Only one of three AAOS criterion was proved probable indicator of clinic treatment. Three factors, namely age, intra-articular step-off as well as with other fractures, were proved probable actually surgery indications (P < 0.05). AAOS surgery criteria of distal radius fractures were partially instructive, but not so precise predictors for actually operation. In the clinic, the choice of operative treatment correlated with multiple factors.
- 1 December 2018
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 60, 137-140
Management of distal radius fracture: A comparison of actual and theoretical treatments
The objective of this study was to explore whether there were any differences between the theoretical operative treatment of distal radius fractures according to AAOS guideline on basis of measurement of radiographs and the treatment they actually received in our institution. From April 2015 to February 2018, a total of 693 patients with 697 fresh close adult distal radius fractures were evaluated retrospectively. Fractures were respectively grouped into categories by AAOS criterion and actually treatment. After gleaning demographic information and measuring radiographic items, all results were put into a database. Single factors analysis, Chi-square test and further logistic regression analysis were performed to determine correlations between actual and theoretical treatments. In all 240 fractures fulfilled at least one AAOS criterion for surgery, only 61 fractures actually received operation. And in the conservative group recommended by AAOS, 52 of 457 fractures actually were proceeded with surgery. There were slight correlation between AAOS guideline and actually operation (Phi = 0.181). From multivariable logistic regression analysis, Only one of three AAOS criterion was proved probable indicator of clinic treatment. Three factors, namely age, intra-articular step-off as well as with other fractures, were proved probable actually surgery indications (P < 0.05). AAOS surgery criteria of distal radius fractures were partially instructive, but not so precise predictors for actually operation. In the clinic, the choice of operative treatment correlated with multiple factors.
- Open Access
- 1 December 2018
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 108, 280-287
Possible therapeutic potential of berberine in the treatment of STZ plus HFD-induced diabetic osteoporosis
- 1 December 2018
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 108, 280-287
Open AccessPossible therapeutic potential of berberine in the treatment of STZ plus HFD-induced diabetic osteoporosis
- 15 November 2018
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (3) , 293
Response to Letter to Editor RE: Comparison of the 2 Tight Rope Technique and Clavicular Hook Plate for the Treatment of Rockwood 3 Type III Acromioclavicular Joint Dislocation
(2018). Response to Letter to Editor RE: Comparison of the 2 Tight Rope Technique and Clavicular Hook Plate for the Treatment of Rockwood 3 Type III Acromioclavicular Joint Dislocation. Journal of Investigative Surgery. Ahead of Print.
- 15 November 2018
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (3) , 293
Response to Letter to Editor RE: Comparison of the 2 Tight Rope Technique and Clavicular Hook Plate for the Treatment of Rockwood 3 Type III Acromioclavicular Joint Dislocation
(2018). Response to Letter to Editor RE: Comparison of the 2 Tight Rope Technique and Clavicular Hook Plate for the Treatment of Rockwood 3 Type III Acromioclavicular Joint Dislocation. Journal of Investigative Surgery. Ahead of Print.
- 1 September 2018
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 57, 35-44
Three-dimensional printing assisted ORIF versus conventional ORIF for tibial plateau fractures: A systematic review and meta-analysis
The objective of this meta-analysis was to assess the influence of three dimensional printing technology on the open reduction and internal fixation (ORIF) of tibial plateau fractures from current randomized controlled trials and prospective comparative studies. The electronic literature database of Pubmed, Embase, and Cochrane library were searched in January 2018. The data operation time, intraoperative blood loss, follow-up knee function (Rasmussen score, HSS) and complications (including infection, screw loosening, knee stiffness, knee instability, posttraumatic osteoarthritis, VTE) were extracted. Stata 12.0 software was used for our meta-analysis. 11 RCTs and 6 prospective comparative studies met our inclusion criteria with 358 tibial plateau fractures patients in the 3D group and 378 patients in the routine ORIF group. The meta-analysis showed that there were significant differences in operation time, intraoperative blood loss and bony union time between the 3D group and conventional group. As for the complications and follow-up function recovery evaluated by the excellent and good rate based on HSS and Rasmussen score, no significant differences were found. The 3D group showed shorter operation time, less intraoperative blood loss and faster union time for patients with tibial plateau fractures. Therefore, compared with conventional ORIF, ORIF assisted by three-dimensional printing technology should be a more appropriate treatment of tibial plateau fractures. Further large-sample randomized controlled trials are needed in the future to confirm the superiority of three-dimensional printing assisted ORIF.
- 1 September 2018
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 57, 35-44
Three-dimensional printing assisted ORIF versus conventional ORIF for tibial plateau fractures: A systematic review and meta-analysis
The objective of this meta-analysis was to assess the influence of three dimensional printing technology on the open reduction and internal fixation (ORIF) of tibial plateau fractures from current randomized controlled trials and prospective comparative studies. The electronic literature database of Pubmed, Embase, and Cochrane library were searched in January 2018. The data operation time, intraoperative blood loss, follow-up knee function (Rasmussen score, HSS) and complications (including infection, screw loosening, knee stiffness, knee instability, posttraumatic osteoarthritis, VTE) were extracted. Stata 12.0 software was used for our meta-analysis. 11 RCTs and 6 prospective comparative studies met our inclusion criteria with 358 tibial plateau fractures patients in the 3D group and 378 patients in the routine ORIF group. The meta-analysis showed that there were significant differences in operation time, intraoperative blood loss and bony union time between the 3D group and conventional group. As for the complications and follow-up function recovery evaluated by the excellent and good rate based on HSS and Rasmussen score, no significant differences were found. The 3D group showed shorter operation time, less intraoperative blood loss and faster union time for patients with tibial plateau fractures. Therefore, compared with conventional ORIF, ORIF assisted by three-dimensional printing technology should be a more appropriate treatment of tibial plateau fractures. Further large-sample randomized controlled trials are needed in the future to confirm the superiority of three-dimensional printing assisted ORIF.
- 1 February 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (1) , 83-88
Application of 3D-printing technology in the treatment of humeral intercondylar fractures
- 1 February 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (1) , 83-88
Application of 3D-printing technology in the treatment of humeral intercondylar fractures