Kevin Prieur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin Prieur has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Durox
Laboratoire EM2C, CNRS, CentraleSupélec, Université Paris-Saclay , 3, rue Joliot Curie, Gif-sur-Yvette cedex 91192, France
2 shared publications - Guillaume Vignat
Mechanical Engineering Department, Stanford University 1 , 440 Escondido Mall, Stanford, California 94305
2 shared publications - Sébastien Candel
Laboratoire EM2C, CNRS, CentraleSupélec, Université Paris-Saclay , 3, rue Joliot Curie, Gif-sur-Yvette cedex 91192, France
2 shared publications - Bénédicte Cuenot
CERFACS, 42 Avenue Gaspard Coriolis, Toulouse Cedex 1 31057, France
1 shared publication - Eleonore Riber
CERFACS, 42 Avenue Gaspard Coriolis, Toulouse, Cédex 01 31057, Occitanie, France
1 shared publication - Félix Collin-Bastiani
Safran Aircraft Engines 3 , Rond-point René Ravaud, F-77550 Moissy-Cramayel
1 shared publication
Latest Publications
- 21 January 2021
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (2)
Large-Eddy Simulation of Flame Dynamics During the Ignition of a Swirling Injector Unit and Comparison With Experiments
During the ignition of a swirled single-injector combustor, two phases have been identified experimentally. In the first, the flame penetrates the injection unit, while in the second, the flame lifts off after a substantial delay before stabilizing at a distance from the injector. This transient phenomenon is investigated using Large Eddy Simulations based on an Euler–Lagrange description of the liquid spray, an energy deposition model to mimic ignition, and the thickened flame combustion model. It is shown that the initial penetration of the flame in the injector unit is linked with the positive pressure excursion induced by the rapid volumetric expansion of burnt gases. This sudden expansion is itself due to the fast increase in heat release rate that occurs during the initiation of the process. The corresponding positive and negative pressure disturbances induce a rapid reduction of the mass flow rate through the injector, followed by an acceleration of the flow and a return to the nominal value. It is also shown that the flame root disappears after another delay, which results in the flame edge lifting and stabilization at a distance from the injector exhaust corresponding to steady operation of the device. The relatively long delay time before this liftoff takes place is found to correspond to the residence time of the cooled burnt gases in the vicinity of the chamber walls, which are ultimately entrained by the internal recirculation zone and quench the lower flame foot.
- 21 January 2021
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (2)
Large-Eddy Simulation of Flame Dynamics During the Ignition of a Swirling Injector Unit and Comparison With Experiments
During the ignition of a swirled single-injector combustor, two phases have been identified experimentally. In the first, the flame penetrates the injection unit, while in the second, the flame lifts off after a substantial delay before stabilizing at a distance from the injector. This transient phenomenon is investigated using Large Eddy Simulations based on an Euler–Lagrange description of the liquid spray, an energy deposition model to mimic ignition, and the thickened flame combustion model. It is shown that the initial penetration of the flame in the injector unit is linked with the positive pressure excursion induced by the rapid volumetric expansion of burnt gases. This sudden expansion is itself due to the fast increase in heat release rate that occurs during the initiation of the process. The corresponding positive and negative pressure disturbances induce a rapid reduction of the mass flow rate through the injector, followed by an acceleration of the flow and a return to the nominal value. It is also shown that the flame root disappears after another delay, which results in the flame edge lifting and stabilization at a distance from the injector exhaust corresponding to steady operation of the device. The relatively long delay time before this liftoff takes place is found to correspond to the residence time of the cooled burnt gases in the vicinity of the chamber walls, which are ultimately entrained by the internal recirculation zone and quench the lower flame foot.
- 9 January 2019
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (6)
Flame and Spray Dynamics During the Light-Round Process in an Annular System Equipped With Multiple Swirl Spray Injectors
A successful ignition in an annular multi-injector combustor follows a sequence of steps. The first injector is ignited; two arch-shaped flame branches nearly perpendicular to the combustor backplane form; they propagate, igniting each injection unit; they merge. In this paper, characterization of the propagation phase is performed in an annular combustor with spray flames fed with liquid n-hepane. The velocity and the direction of the arch-like flame branch are investigated. Near the backplane, the flame is moving in a purely azimuthal direction. Higher up in the chamber, it is also moving in the axial direction due to the volumetric expansion of the burnt gases. Time-resolved particle image velocimetry (PIV) measurements are used to investigate the evaporating fuel droplets dynamics. A new result is that, during the light-round, the incoming flame front pushes the fuel droplets in the azimuthal direction well before its leading point. This leads to a decrease in the local droplet concentration and local mixture composition over not yet lit injectors. For the first time, the behavior of an individual injector ignited by the passing flame front is examined. The swirling flame structure formed by each injection unit evolves in time. From the ignition of an individual injector to the stabilization of its flame in its final shape, approximately 50 ms elapse. After the passage of the traveling flame, the newly ignited flame flashbacks into the injector during a few milliseconds, for example, 5 ms for the conditions that are tested. This could be detrimental to the service life of the unit. Then, the flame exits from the injection unit, and its external branch detaches under the action of cooled burnt gases in the outer recirculation zone (ORZ).
- 9 January 2019
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (6)
Flame and Spray Dynamics During the Light-Round Process in an Annular System Equipped With Multiple Swirl Spray Injectors
A successful ignition in an annular multi-injector combustor follows a sequence of steps. The first injector is ignited; two arch-shaped flame branches nearly perpendicular to the combustor backplane form; they propagate, igniting each injection unit; they merge. In this paper, characterization of the propagation phase is performed in an annular combustor with spray flames fed with liquid n-hepane. The velocity and the direction of the arch-like flame branch are investigated. Near the backplane, the flame is moving in a purely azimuthal direction. Higher up in the chamber, it is also moving in the axial direction due to the volumetric expansion of the burnt gases. Time-resolved particle image velocimetry (PIV) measurements are used to investigate the evaporating fuel droplets dynamics. A new result is that, during the light-round, the incoming flame front pushes the fuel droplets in the azimuthal direction well before its leading point. This leads to a decrease in the local droplet concentration and local mixture composition over not yet lit injectors. For the first time, the behavior of an individual injector ignited by the passing flame front is examined. The swirling flame structure formed by each injection unit evolves in time. From the ignition of an individual injector to the stabilization of its flame in its final shape, approximately 50 ms elapse. After the passage of the traveling flame, the newly ignited flame flashbacks into the injector during a few milliseconds, for example, 5 ms for the conditions that are tested. This could be detrimental to the service life of the unit. Then, the flame exits from the injection unit, and its external branch detaches under the action of cooled burnt gases in the outer recirculation zone (ORZ).