HXHao Xie

Hao Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hao Xie has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 无监督掩码循环对抗网络实现细胞虚拟染色

    by Jun-Hao Lin, Yun-Fei Zhang, Shao-Wei Chen, Guo-Xun Zhang, Hao Xie

    The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。

  • Patterned Line-illumination Mesoscopy with a moving slit for Enhancing Background Suppression in Cortex-wide Mouse Brain Imaging

    by Chaowei Zhuang, Yi Yang, Hao Xie

    Wide-field mesoscopy provides the capabilities of cortex-wide field of view (FOV), cellular resolution and high frame rate for neuronal imaging in the mouse brain. However, inherent background fluorescence degrades the image quality and hinders neuronal signal extraction. To address this problem, we first introduce a cortex-wide, high-resolution line-illumination mesoscope with a moving slit designed for in vivo mouse brain imaging. This system achieves a 6.6×6.6-mm FOV, micro scale cellular resolution, a high frame rate of 10 Hz, as well as the background rejection ability. Furthermore, we integrated patterned illumination into the system to enhance the background suppression. Experimental results show that the proposed system successfully captures neurodynamics in the living mouse brain. Compared to conventional wide-field mesoscopes, the cortex-wide patterned line-illumination mesoscope (PLIM) achieves a 3-fold increase in signal-to-background ratio (SBR). With patterned illumination integrated, the SBR enhancement further reaches 4.5-fold.

  • Open Access

    Optimizing femtosecond laser fabricating strategy of Nitinol hypotube for vascular interventional surgery

    by Yunfeng Song, Zhiwei Yang, Tiangang Xu, Hao Xie, Depeng Wang, Lan Chen, Xusan Yang

    Guidewires and catheters are essential in minimally invasive procedures, particularly in accessing targets within the vascular system for neuron surgery. Femtosecond lasers can precisely cut nickel-titanium micro tubes, known as Nitinol hypotubes, serving as the heads of micro guidewires while protecting their core tips. The quality and geometry of these hypotubes depend on the focus of the laser cutting system. We evaluated the cutting efficiency and quality of Nitinol hypotubes using objective lenses with three numerical apertures (NA). Quantitative analysis indicated that higher NA objectives yield better surface quality, resulting in lower debris. Additionally, cutting with high NA objectives produced significantly lower arithmetic mean surface roughness and enhanced mechanical properties. Using a two-temperature model, we simulated the interaction between femtosecond lasers and Nitinol, showing that higher NA objectives increase electron temperatures, thus improving material removal efficiency. This study also tested the optimized Nitinol hypotube prformance in simulations of invasive neuron surgery.

  • A miniaturized mesoscope for the large-scale single-neuron-resolved imaging of neuronal activity in freely behaving mice

    by Yuanlong Zhang, Lekang Yuan, Qiyu Zhu, Jiamin Wu, Tobias Nöbauer, Rujin Zhang, Guihua Xiao, Mingrui Wang, Hao Xie, Zengcai Guo, et al.

    Exploring the relationship between neuronal dynamics and ethologically relevant behaviour involves recording neuronal-population activity using technologies that are compatible with unrestricted animal behaviour. However, head-mounted microscopes that accommodate weight limits to allow for free animal behaviour typically compromise field of view, resolution or depth range, and are susceptible to movement-induced artefacts. Here we report a miniaturized head-mounted fluorescent mesoscope that we systematically optimized for calcium imaging at single-neuron resolution, for increased fields of view and depth of field, and for robustness against motion-generated artefacts. Weighing less than 2.5 g, the mesoscope enabled recordings of neuronal-population activity at up to 16 Hz, with 4 μm resolution over 300 μm depth-of-field across a field of view of 3.6 × 3.6 mm2 in the cortex of freely moving mice. We used the mesoscope to record large-scale neuronal-population activity in socially interacting mice during free exploration and during fear-conditioning experiments, and to investigate neurovascular coupling across multiple cortical regions.


  • Open Access

    Selective illumination on line-scanning confocal mesoscope enhances background rejection in cortex-wide mouse brain imaging

    by Hao Xie

    Confocal microscope has optical sectioning that is accessible for structural and dynamic imaging in in vivo mouse brain. With the requirement of brain-wide field-of-view (FOV) in many neuroscience researches, existing confocal microscope fails to fulfill the requirement. Here, we proposed the brain-wide, high resolution line-scan confocal mesoscope (LSCM) for in vivo mouse imaging, achieving 6.6-mm-FOV, 3.2-μm-resolution and video-rate acquisition. To further enhance the background rejection ability, we introduced the selective illumination method into our system. We demonstrated that the proposed technique is s able to image the neurodynamics in in vivo mouse brain. Comparing to the LSCM and wide-field mesoscope, our selective illumination line-scan confocal mesoscope improves more than 25% and 3 times background rejection ability, respectively.

  • Top Cited Papers

    Improved green and red GRAB sensors for monitoring spatiotemporal serotonin release in vivo

    by Fei Deng, Jinxia Wan, Guochuan Li, Hui Dong, Xiju Xia, Yipan Wang, Xuelin Li, Chaowei Zhuang, Yu Zheng, Laixin Liu, et al.

    The serotonergic system plays important roles in both physiological and pathological processes, and is a therapeutic target for many psychiatric disorders. Although several genetically encoded GFP-based serotonin (5-HT) sensors were recently developed, their sensitivities and spectral profiles are relatively limited. To overcome these limitations, we optimized green fluorescent G-protein-coupled receptor (GPCR)-activation-based 5-HT (GRAB5-HT) sensors and developed a red fluorescent GRAB5-HT sensor. These sensors exhibit excellent cell surface trafficking and high specificity, sensitivity and spatiotemporal resolution, making them suitable for monitoring 5-HT dynamics in vivo. Besides recording subcortical 5-HT release in freely moving mice, we observed both uniform and gradient 5-HT release in the mouse dorsal cortex with mesoscopic imaging. Finally, we performed dual-color imaging and observed seizure-induced waves of 5-HT release throughout the cortex following calcium and endocannabinoid waves. In summary, these 5-HT sensors can offer valuable insights regarding the serotonergic system in both health and disease.


  • Open Access

    Multifocal fluorescence video-rate imaging of centimetre-wide arbitrarily shaped brain surfaces at micrometric resolution

    by Hao Xie, Xiaofei Han, Guihua Xiao, Hanyun Xu, Yuanlong Zhang, Guoxun Zhang, Qingwei Li, Jing He, Dan Zhu, Xinguang Yu, et al.

    Fluorescence microscopy allows for the high-throughput imaging of cellular activity across brain areas in mammals. However, capturing rapid cellular dynamics across the curved cortical surface is challenging, owing to trade-offs in image resolution, speed, field of view and depth of field. Here we report a technique for wide-field fluorescence imaging that leverages selective illumination and the integration of focal areas at different depths via a spinning disc with varying thickness to enable video-rate imaging of previously reconstructed centimetre-scale arbitrarily shaped surfaces at micrometre-scale resolution and at a depth of field of millimetres. By implementing the technique in a microscope capable of acquiring images at 1.68 billion pixels per second and resolving 16.8 billion voxels per second, we recorded neural activities and the trajectories of neutrophils in real time on curved cortical surfaces in live mice. The technique can be integrated into many microscopes and macroscopes, in both reflective and fluorescence modes, for the study of multiscale cellular interactions on arbitrarily shaped surfaces.


  • Extract latent features of single-particle trajectories with historical experience learning

    by Yongyu Zhang, Feng Ge, Xijian Lin, Jianfeng Xue, Yuxin Song, Hao Xie, Yan He


  • Open Access

    Monitoring norepinephrine release in vivo using next-generation GRAB NE sensors

    by Jiesi Feng, Hui Dong, Julieta Lischinsky, Jingheng Zhou, Fei Deng, Chaowei Zhuang, Xiaolei Miao, Huan Wang, Hao Xie, Guohong Cui, et al.

    Summary: Norepinephrine (NE) is an essential biogenic monoamine neurotransmitter, yet researches using prototype NE sensors were limited by their low sensitivities. Here, we developed next-generation versions of GPCR activation-based NE sensors (GRAB NE2m and GRAB NE2h ) with a superior response, high sensitivity and selectivity to NE both in vitro and in vivo . Notably, these sensors can detect NE release triggered by either optogenetic or behavioral stimuli in freely moving mice, producing robust signals in the locus coeruleus and hypothalamus. With the development of a novel transgenic mouse line, we recorded both NE release and calcium dynamics with dual-color fiber photometry throughout the sleep-wake cycle; moreover, dual-color mesoscopic imaging revealed cell type‒specific spatiotemporal dynamics of NE and calcium during sensory processing and locomotion. Thus, these new GRAB NE sensors are valuable tools for monitoring the precise spatiotemporal release of NE in vivo , providing new insights into the physiological and pathophysiological roles of NE.


  • Open Access

    Dual-color GRAB sensors for monitoring spatiotemporal serotonin release in vivo

    by Fei Deng, Jinxia Wan, Guochuan Li, Hui Dong, Xiju Xia, Yipan Wang, Xuelin Li, Chaowei Zhuang, Yu Zheng, Laixin Liu, et al.

    The serotonergic system plays important roles in both physiological and pathological processes, and is a widely used therapeutic target for many psychiatric disorders. Although several genetically encoded GFP-based serotonin (5-HT) sensors were recently developed, their sensitivities and spectral profiles are relatively limited. To overcome these limitations, we optimized green fluorescent G-protein-coupled receptor (GPCR)-activation-based 5-HT (GRAB 5-HT ) sensors and developed a new red fluorescent GRAB 5-HT sensor. These sensors have excellent cell surface trafficking, high specificity, sensitivity, and spatiotemporal resolution, making them suitable for monitoring 5-HT dynamics in vivo . Besides recording subcortical 5-HT release in freely moving mice, we observed both uniform and gradient 5-HT release in the mouse dorsal cortex with mesoscopic imaging. Finally, we performed dual-color imaging and observed seizure-induced waves of 5-HT release throughout the cortex following calcium and endocannabinoid waves. In summary, these 5-HT sensors can offer valuable insights regarding the serotonergic system in both physiological and pathological states.