OSOlivier Sèbe

Olivier Sèbe

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Olivier Sèbe has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Separation of Source, Site, and Path Effects Based on Elastic Radiative Transfer Theory, Part 2: Generalized Inversion of Source and Site Parameters and Application to Metropolitan France

    by Grégoire Heller, Olivier Sèbe, Ludovic Margerin, Paola Traversa, Marie Calvet, Jessie Mayor

    Magnitudes of small earthquakes are subject to large uncertainties due to high-frequency (>1 Hz) propagation effects. Reliable estimates of magnitudes and source properties are essential for hazard assessment. To address this, we developed a two-step inversion procedure to separate source, attenuation, and site properties. First, path effects are extracted from data envelopes in the 0.375–24 Hz band for each source–station pair, as detailed in the companion article (Heller et al., 2026). Second, source and site amplification spectra are separated using a generalized inversion algorithm, with site amplification adjusted on reference stations exhibiting approximately flat horizontal-to-vertical (H/V) ratios. From the source spectra, we infer the moment magnitude Mw, corner frequency fc, apparent stress σapp, and stress drop Δσ. We apply the inversion procedure to approximately 21,000 waveforms recorded by the European Plate Observing System - France and Commissariat à l’Énergie Atomique et aux Énergies Alternatives stations at hypocentral distances less than 250 km, for earthquakes of magnitude ML 2.0–5.9. The magnitudes Mw deduced from 1279 source spectra are in strong agreement with the unified Euro-Mediterranean catalog. The comparison with the SI-Hex catalog illustrates the impact of attenuation variations across France on source parameter estimation. We also highlight the role of the inversion strategy. In the generalized inversion, σapp moderately increases with seismic moment M0, with a scaling exponent of 0.24 ± 0.08, without regional differences. In contrast, a single-event (SE) inversion scheme yields spatial variations of σapp with a systematically higher level in western France. This regional difference is caused by a regional site effect that is not considered in a SE separation scheme. The choice of reference for site amplification also matters. Using all stations for reference instead of stations with approximately flat H/V ratios, magnitudes are overestimated by 0.1–0.2 units and σapp increases more rapidly with M0. These results show the importance of properly accounting for attenuation and site effects when estimating source parameters.


  • Open Access

    Separation of Source, Site, and Path Effects Based on Elastic Radiative Transfer Theory. Part 1: Mapping of Scattering and Absorption Properties and Application to Metropolitan France

    by Grégoire Heller, Ludovic Margerin, Olivier Sèbe, Paola Traversa, Marie Calvet, Jessie Mayor

    We present the first 2D scattering and absorption maps of Metropolitan France in the 0.375–24 Hz frequency band. To obtain these maps, we use a hybrid linearized inversion/grid-search scheme to adjust the scattering and absorption quality factors, and the product of site amplification and source energy for each seismogram envelope separately. To compute seismogram envelopes and their partial derivatives, we perform Monte Carlo simulations of elastic radiative transfer, taking into account scattering anisotropy, coupling between P and S waves, as well as partial trapping of energy in the crust. Next, scattering and absorption parameters are mapped in a ray tomographic manner, using a least-squares algorithm with second-order Tikhonov regularization. We apply the mapping procedure to around 21,000 waveforms recorded by European Plate Observing System–France and Commissariat à l’Énergie Atomique et aux Énergies Alternatives stations at hypocentral distances less than 250 km, for earthquakes with local magnitudes ML ranging from 2.0 to 5.9. Attenuation maps show strong spatial and frequency variations. Spatial variations can reach a factor 3 for scattering and 2 for absorption compared with the average attenuation in France. Although scattering dominates absorption at low frequency (<1 Hz), the opposite occurs at higher frequency. Strong scattering anomalies can be associated with recent sedimentary basins (Quaternary and late Cenozoic) at low frequency, and a few Mesozoic basins or deep sedimentary basins at higher frequency. Absorption is strongest in the western Pyrenees and the French Alps, with a frequency-dependent pattern for the latter. Absorption is also strong at low frequency in the northern basins and Ardennes massif. By contrast, old Variscan units show low scattering attenuation especially at low frequency, and the Armorican massif is consistently the least absorbing region. Such spatial and frequency-dependent attenuation variations likely contribute to the strong variability of ground motions in France, making our model of attenuation of interest for future seismic hazard studies.


  • Open Access

    Magnitude and source spectra estimation using an elastic radiative transfer modelling of seismic wave-field attenuations: application to a French dataset.

    by Grégoire Heller, Olivier Sèbe, Ludovic Margerin, Paola Traversa, Marie Calvet, Jessie Mayor

    Accurate magnitude estimates and reliable propagation models are essential for seismic hazard assessment. Unfortunately, the magnitudes of small earthquakes remain subject to significant uncertainties, primarily due to complex high-frequency propagation effects. Similarly, spatial variations in attenuation properties are crucial for refining ground motion models and reducing epistemic uncertainties in seismic hazard assessment. This study proposes (1) to map attenuation properties (scattering and absorption) in Metropolitan France using the radiative transfer theory of elastic waves, and (2) to simultaneously estimate source and site spectra through a generalized inversion. The recovered source spectra provide access to the moment magnitude Mw, corner frequency fc, and apparent stress σapp.We apply the entire inversion procedure to approximately 21,000 recordings from the EPOS-FR and CEA databases, including events with local magnitudes ML ranging from 2.0 to 5.9, and stations with hypocentral distances of less than 250 km. The estimated attenuation maps reveal strong spatial and frequency-dependent variations. Scattering dominates absorption at low frequencies (< 1 Hz), while absorption prevails at high frequencies. Strong scattering anomalies are concentrated in recent sedimentary basins at low frequencies and in deformed regions or deep sedimentary basins at medium and high frequencies. Conversely, Variscan units exhibit low scattering attenuation, especially at low frequencies. Absorption is highest in the French Alps and the western Pyrenees and lowest in the Armorican Massif. Concurrently, a catalog of 1,279 Mw magnitudes and 577 site terms is established for Metropolitan France. The obtained magnitudes are consistent with those in the unified Euro-Mediterranean catalog. Its comparison with the SI-Hex catalog highlights the importance for correcting the attenuation variations before extracting source parameters and especially the magnitude. The analysis of the apparent stress σapp reveals a moderate increase with the seismic moment M0 (scaling exponent of 0.24±0.08), without any marked regional trend. Finally, we emphasize the importance of rigorously correcting for site effects, using reference stations on bedrock and of ensuring inter-event connectivity during the generalized inversion process through the existence of common stations across event records. The next step is to integrate this approach and related results in CEA seismic alert operational framework.

  • Open Access

    Observation of the microseismic peak from Distributed Acoustic Sensing (DAS) measurements at the LSBB underground Laboratory

    by Olivier Sèbe, Camille Jestin, Amaury Vallage, Stéphane Gaffet, Daniel Boyer, Alain Cavaillou, Jean-Baptiste Decitre, Charly Lallemand, Vincent Lanticq, Olivier Rousseau

    Thanks to its ability to provide dense strain rate measurements along Optical Fiber (OF) cable, the Distributed Acoustic Sensing (DAS) technique spreads over different seismic and geophysical domains. They range from exploration geophysics (Mestayer et al. 2011, Daley et al. 2013), to underground structure imaging (e.g. Ajo-Franklin et al. 2019, Cheng et al. 2021) or seismic activity and background noise monitoring (Jousset et al 2018, Nayak et al. 2021). Beyond the advantage of its dense spatial sampling and given a better understanding of its instrument response (e.g. Lindsey et al. 2020), the detection performance of these new DAS measurements also depends on its ability to precisely characterize the amplitude and phase of the seismic background noise in different environments. According to recent offshore seismic noise studies (Ugalde et al. 2021, Lior et al. 2021, Guerin et al 2022), we propose a study based on DAS recordings of the seismic background noise in an on-land quiet environment. In 2020, a temporary seismic experiment PREMISE (PREliminary MIga Seismic Experiment) was carried out on the site of the underground low noise Laboratory (LSBB, Laboratoire Souterrain Bas Bruit) at Rustrel, France, in order to study the 3D seismic wave field properties in a pretty well-known underground geological structure. During this experiment, we deployed several kilometers of different OF in the LSBB galleries in order to create a multidirectional DAS array with a total fiber length of 10.5km and several ground-coupling conditions. We reprocessed two hours of “raw” DAS data, recorded with a FEBUS A1-R instrument, with different acquisition parameters to find the best configuration for enhancing the DAS measurement Signal to Noise Ratio. The power spectral density (PSD) of these reprocessed strain time-series reveals a peak in the background noise frequency range [0.08-0.25Hz] for gauge lengths of 90m and 150m. Independently, an estimation of the local strain field has been derived by a geodetic analysis (Spudich et al 1995) of the records from the LSBB broadband seismometers antenna. The comparison of the DAS and seismometers array-derived strain PSD shows a very good agreement with the secondary microseism peak in terms of frequency band, amplitude, and the wave field polarization, especially for DAS strain records processed with gauge-length of several tens of meters.

  • Open Access

    Uncertainty assessment of the array derived rotation measurements

    by Roxanne Rusch, Olivier Sèbe, Stéphane Gaffet, Jean-Baptiste Decitre, Charly Lallemand, Daniel Boyer, Alain Cavaillou, François Schindele

    Analyzing the rotational motions of the seismic wavefield is useful for a multitude of applications ranging from the wavefield decomposition to geological structure estimation or source inversion (Igel et al. 2015, Sollberger et al. 2020). Despite the recent progress in performance (Bernauer et al. 2018), portable rotation sensors are not yet able to measure the seismic background noise in quiet environment. Parallel to the construction of high performance observatory sensors (Igel et al. 2021), several experimentations have shown that seismic rotation motions can be derived from the recordings of classical three translational component (3C) seismometers when arranged in a dense seismic array (Spudich et al. 1995, Suryanto et al. 2006) . Even if these Array Derived Rotation (ADR) measurements can theoretically estimate the seismic rotation background noise, the accuracy of this kind of indirect measurements can be strongly affected by the quality and the variability in the sensors response or installation conditions across the seismic array (Donner et al. 2017). This work proposes to quantify, as a function of the array aperture and wavefield properties (frequency and wavelength), the uncertainty of the ADR measurements due to uncertainty or lack of detailed knowledge in the precise locations of sensors, orientations and instrumental response, along with the effects of some incoherent disturbing noises across the seismic sensor array. This approach has been applied to the ADR measurements performed with the (3C) dense seismic array deployed at the Low Noise Inter-Disciplinary Underground Science & Technology laboratory (LSBB), Rustrel, France. This analysis shows that a particular attention has to be paid, beyond the standard practices accepted for most seismic arrays, concerning the sensors’ setting up in order to reach uncertainty lower than 10% on the derived rotation measurements.

  • Open Access

    Rotation, Strain, and Translation Sensors Performance Tests with Active Seismic Sources

    by Felix Bernauer, Kathrin Behnen, Joachim Wassermann, Sven Egdorf, Heiner Igel, Stefanie Donner, Klaus Stammler, Mathias Hoffmann, Pascal Edme, David Sollberger, et al.

    Interest in measuring displacement gradients, such as rotation and strain, is growing in many areas of geophysical research. This results in an urgent demand for reliable and field-deployable instruments measuring these quantities. In order to further establish a high-quality standard for rotation and strain measurements in seismology, we organized a comparative sensor test experiment that took place in November 2019 at the Geophysical Observatory of the Ludwig-Maximilians University Munich in Fürstenfeldbruck, Germany. More than 24 different sensors, including three-component and single-component broadband rotational seismometers, six-component strong-motion sensors and Rotaphone systems, as well as the large ring laser gyroscopes ROMY and a Distributed Acoustic Sensing system, were involved in addition to 14 classical broadband seismometers and a 160 channel, 4.5 Hz geophone chain. The experiment consisted of two parts: during the first part, the sensors were co-located in a huddle test recording self-noise and signals from small, nearby explosions. In a second part, the sensors were distributed into the field in various array configurations recording seismic signals that were generated by small amounts of explosive and a Vibroseis truck. This paper presents details on the experimental setup and a first sensor performance comparison focusing on sensor self-noise, signal-to-noise ratios, and waveform similarities for the rotation rate sensors. Most of the sensors show a high level of coherency and waveform similarity within a narrow frequency range between 10 Hz and 20 Hz for recordings from a nearby explosion signal. Sensor as well as experiment design are critically accessed revealing the great need for reliable reference sensors.


  • Spectral Factorization of the Source Time Function of an Earthquake from Coda Waves, Application to the 2003 Rambervillers, France, Earthquake

    by Olivier Sèbe, Jocelyn Guilbert, Pierre‐Yves Bard

    In a previous work, a spectral factorization algorithm of the seismic coda wavefield was implemented to extract the underwater source time function (STF) of the Kursk’s explosion from a single regional record (Sèbe et al., 2005). The purpose of this study is to apply this approach to natural earthquake events, on the example of a moderate‐size event (⁠Mw 4.9) in northeastern France. The main difficulty of such an adjustment lies in the reliability of the minimum phase assumption required by the spectral factorization algorithm. An investigation of the phase properties of earthquake STF indicates that classical single‐patch models such as the Brune model fulfill the minimum phase condition, whereas multiple patch models probably do not. Nevertheless, it is shown that minimum phase wavelets (MPWs) provide reliable information on the actual STF properties such as the duration, seismic moment, and even the actual time history. A statistical study on the time‐domain differences between 20,000 arbitrary finite duration wavelets and their minimum phase equivalent supports an a priori minimum phase criterion based on the time–frequency spread of the recovered STF: the lower the latter, the smaller the time‐domain discrepancy between the estimated MPW and the unknown actual one. The seismic coda spectral factorization algorithm has then been applied to a moderate‐size earthquake Mw 4.9 that occurred near Rambervillers (northeastern France, 22 February 2003). The stability of the retrieved STF from different, distant rock site stations, the correct estimation of the moment magnitude, and the successful comparison with STF obtained by the empirical Green’s function deconvolution approach demonstrate the reliability and the robustness of the method as well as the usefulness of the proposed minimum phase criterion.


  • Moderate Earthquake Teleseismic Depth Estimations: New Methods and Use of the Comprehensive Nuclear-Test-Ban Treaty Organization Network Data

    by J. Letort, J. Vergoz, J. Guilbert, F. Cotton, O. Sebe, Y. Cano

    We investigate the possibility to estimate the depths of earthquakes of moderate magnitude (3.5>Mmb 3.6 Ardèche earthquake (France, 3 August 2011). In the case of the Po Plain earthquake (Italy, 27 January 2012), this provides another example of the great interest in teleseismic analysis, where the detection of the Moho reflected phase (pmP) shows without doubt an upper‐mantle event. Finally, the Murcia event (Spain, 11 May 2011) shows the limits of these methods for very shallow events (<4–5 km). We show that these new depth determinations improve our ability to understand the geologic processes, as they provide complementary information on the source and are not affected by lateral crustal heterogeneities.