CLChad Lavender

Chad Lavender

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chad Lavender has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    No Significant Difference in Cost or Outcomes at 1‐Year Minimum Follow‐Up After Arthroscopic Partial Meniscectomy Comparing 1.9 mm Distal Chip‐on‐Tip Needlescope Versus 4 mm Glass Rod Lens Arthroscope: Both Treatments Are Highly Cost‐Effective

    by James H. Lubowitz, Chad Lavender

    Purpose: To evaluate cost, outcomes, and incremental cost‐effectiveness of arthroscopic partial meniscectomy comparing visualization using a 1.9 mm distal chip‐on‐tip needlescope versus a standard 4 mm glass rod lens arthroscope. Methods: We retrospectively reviewed prospectively collected data (from a larger randomized controlled trial) on patients having partial meniscectomy performed by 1 surgeon at 1 facility between February 2023 and February 2025. International Knee Documentation Committee and visual analog scale pain scores at 1‐year minimum follow‐up, costs, cost‐effectiveness (cost/quality‐adjusted life years [QALYs]), and incremental cost‐effectiveness ratio (cost of 1 additional year of life in perfect health) were collected. Sensitivity analyses were assessed for potential variations in cost or effectiveness. Results: Twenty‐four patients are included in each group; mean follow‐up is 26 months (range 12‐36). Comparing needle versus standard, mean age (years) is 50 versus 46.5 ( P = .19); percent male sex is 71 versus 46 ( P = .14); improvement in International Knee Documentation Committee is 58.7 versus 48.7 ( P = .24); improvement in visual analog scale is 5.4 versus 4.5 ( P = .55). Mean cost per case is $17,236.69 versus $16,994.00 ( P = .26). Cost‐effectiveness is $1177.32/QALY versus $1215.59/QALY. The incremental cost‐effectiveness ratio is $367.71. Sensitivity analysis shows that if the costs of needle decreased to equal the costs of standard, needle becomes cost‐neutral while providing superior outcomes (dominant), and if the effectiveness of standard arthroscopy increased to equal needle, needle becomes dominated (more expensive, effectiveness neutral). Conclusions: Arthroscopic partial meniscectomy comparing 1.9 mm distal chip‐on‐tip needlescope versus 4 mm glass rod lens arthroscope results in no significant differences in cost or outcomes at 1‐year minimum follow‐up. Both treatments are highly cost‐effective. Incremental cost‐effectiveness ratio for needlescope compared with arthroscope, $367.71, is more than 2 orders of magnitude lower than the willingness‐to‐pay threshold of $50,000/QALY. Level of Evidence: Level IV, economic: input data from Level III study and uncertainty as examined by univariate sensitivity analysis.

  • Open Access

    High Return to Activity and Low Rerupture Rates Following All‐Inside Quadriceps Tendon Anterior Cruciate Ligament Reconstruction With Bone Marrow Aspirate, Demineralized Bone Matrix, and Suture Tape Augmentation

    by Jake Peterson, Claire Soucier, Jonathan Groves, Andrew L. Schaver, Timothy E. Hewett, Ethan Hahn, James Nottingham, Dana S. Lycans, Chad D. Lavender

    Purpose: To evaluate clinical outcomes of anterior cruciate ligament reconstruction (ACLR) using a quadriceps tendon autograft (QTA) with adjunctive bone marrow aspirate concentrate, demineralized bone matrix, and suture tape augmentation. Methods: A retrospective review was conducted using a prospectively maintained registry of patients who underwent all‐inside ACLR with QTA, adjunctive bone marrow aspirate concentrate, demineralized bone matrix, and suture tape augmentation between July 2018 and October 2022 at a single institution. Patients with less than a 2‐year follow‐up were excluded. A telephone survey assessed return to preinjury activity level, and patient‐reported outcomes were collected, including the International Knee Documentation Committee subjective score, ACL Return to Sport after Injury score, and Visual Analog Scale for pain. Complications such as graft rerupture and total reoperations were also recorded. Results: One hundred twenty patients (81%) received QTA ACLR, with 98 (81.7%) completing ≥2‐year follow‐up (37 female, 61 male; mean age 19.4 years, range 15‐32). Mean follow‐up was 3.4 years (range, 2.0‐5.9). All patients were cleared for full activity at 6 months postoperatively. At the time of telephone follow‐up, 90 patients (91.8%) reported they had returned to their preinjury activity levels. In all 98 patients, mean International Knee Documentation Committee and ACL Return to Sport after Injury scores were 84.0 ± 7.3 and 93.4 ± 17.2, respectively. There were 3 graft reruptures (3.1%) and 9 contralateral ACL tears (9.2%). Conclusions: All‐inside ACLR with QTA, adjunctive bone marrow aspirate concentrate, demineralized bone matrix, and suture tape augmentation showed high rates of return to preinjury activity and low graft rerupture rates at a minimum of 2 years of follow‐up. Level of Evidence: Level IV, retrospective therapeutic case series.

  • Opioid use following partial meniscectomy with needle arthroscopy compared to standard knee arthroscopy: Results from a randomized multicenter trial

    by Chad D. Lavender, Ethan Hahn, Tyler H. Hwang, Andrew L. Schaver, Eliana S. LeMaster, James Nottingham, Timothy E. Hewett, Evan H. Argintar


  • Open Access

    Return to activity following ACL Reconstruction with the Fertilized ACL: A retrospective study.

    by Chad Lavender, Timothy Hewett, John Johnson, Richard Peluso, Tyag Patel, Shane Taylor

    Introduction The objective of this retrospective study is to evaluate outcomes in patients who underwent the fertilized anterior cruciate ligament (ACL) reconstruction procedure. We aim to investigate the return to previous level of activity, safety, and re-rupture rates of the ACL reconstruction augmented with bone marrow concentrate, demineralized bone matrix, autograft bone, and a suture tape (the fertilized ACL). Methods A comprehensive review of medical records was conducted for patients treated with the fertilized ACL (FACL). Medical records of all the patients who underwent reconstruction surgery between July 2018 and January 2021 were evaluated. The inclusion criteria for the study were patients with a defined ACL tear based on clinical examination and magnetic resonance imaging testing who received FACL reconstruction between July 2018 and January 2021. Exclusion criteria included revision ACL reconstruction, non FACL reconstruction, and patients that underwent the FACL reconstruction outside of the defined time period. Thirteen patients underwent reconstruction using a Graftlink allograft (Lifenet Virginia Beach, Va) and 38 using quadriceps autografts. All patients received the FACL reconstruction using bone marrow concentrate, demineralized bone matrix, autograft bone, and suture tape. A phone survey was conducted to obtain patient-reported outcome measures including return to previous level of activity, International Knee Documentation Committee (IKDC), ACL Return to Sport After Injury (ACL RSI), and Visual Analogue Scale (VAS) values. A chart review was conducted for complications and questions were asked during the phone survey regarding return to operating room, infections, and re-ruptures. Results Data analysis revealed 94% of the patients returned to their previous level of activity. The average IKDC and ACL RSI scores were 94% (SD, 9.0) and 92% (SD,15.3), respectively. The average VAS score was .9/10 (SD, 1.2). One patient required reoperation for pain at 1 year. No re-ruptures were observed. Conclusion This retrospective study sheds light on the FACL, which adds biology and an internal brace to an ACL reconstruction, as a reliable and safe option when performing an ACL reconstruction. Very low complication rates were seen in this consecutive series followed for a mean of 2 years. Patients had an extremely high level of return to previous level of sport/activity.


  • Partial meniscectomy using needle arthroscopy associated with significantly less pain and improved patient reported outcomes at two weeks after surgery: A comparison to standard knee arthroscopy

    by Andrew L. Schaver, Jonathan G. Lash, Micah L. MacAskill, Shane Taylor, Timothy E. Hewett, John J. Jasko, Evan H. Argintar, Chad D. Lavender


  • Open Access

    Rotator Cuff Repair Using a Needle Arthroscope Through a Dual‐Lumen Flexible Cannula

    by Chad Lavender, Shane Taylor, Micah Macaskill, Richard Peluso, Timothy Hewett, John Jasko

    The advent of arthroscopy in shoulder surgery has allowed for the development of minimally invasive techniques for the treatment of shoulder pathology. Further developments in needle arthroscopy have continued this trend toward less invasive shoulder surgery, allowing for decreased pain using smaller portals and decreased fluid irrigation through the shoulder joint during surgery. This technique describes a minimally invasive rotator cuff repair using a dual‐lumen cannula that provides both direct visualization and direct instrument access to the pathology. This new cannula has the potential to further refine and to simplify needle arthroscopic techniques about the shoulder. With judicious patient selection, needle arthroscopy is a viable option for the treatment of common shoulder pathology. Technique Video: video See video under supplementary data.


  • Open Access

    Excision of a Knee Cyclops Lesion Using a Needle Arthroscope

    by Chad Lavender, Shane Taylor, Baylor Blickenstaff, Micah Macaskill, Michael Baria

    After anterior cruciate ligament (ACL) reconstruction surgery, achieving full range of motion and strength of the postoperative knee is critical for optimal surgical outcomes. Abnormal tissue growth and scar formation in the postoperative knee can create a block to terminal extension of the knee. Cyclops lesions are areas of granulation tissue with neovascularization and fibrous tissue formation peripherally, most commonly at the anterolateral aspect of the tibial graft site after ACL reconstruction. When these lesions block terminal extension and cause mechanical symptoms, cyclops syndrome is diagnosed, and secondary knee arthroscopy is often performed to remove this tissue to allow for full range of motion. This Technical Note describes a minimally invasive approach with the NanoScope. The NanoScope allows for decreased postoperative pain and swelling with a likely quicker recovery back to normal postoperative therapy. Technique Video: video See video under supplementary data.


  • Open Access

    Nanoscopic Distal Clavicle Resection

    by Luis Filipe Senna, Chad Lavender

    Acromioclavicular joint pathology such as osteoarthritis has historically been treated with either an open or arthroscopic distal clavicle resection. Over the years the trend has been toward more minimally invasive treatment options with the arthroscope. In this article we highlight the use of the nanoscope to visualize the resection which can be performed through a small percutaneous incision. The advantages of this technique include the use of smaller portals, which should lead to improved earlier outcomes, and less iatrogenic damage to the shoulder. Technique Video: video See video under supplementary data.