Latest Publications

  • Open Access

    Surface condensation risk evaluation in light steel framing walls using ISO 13788:2012

    by Paula Daniela Martins, Adriano Pinto Gomes, Carmem Miranda Lage

    In recent years, Light Steel Framing (LSF) system has been increasing in Brazil. Despite numerous advantages when compared with the conventional construction system, such as the agility of the construction process, when inadequately designed, buildings can have their hygrothermal behavior penalized. Pathologies, such as surface condensation, can lead to degradation of the building envelope, and compromise indoor air quality. Thus, the objective of this paper is to evaluate the risk of surface condensation in a specific type of LSF system envelope, in an artificially conditioned environment, in bioclimatic zones 1 and 2 of Brazil. The evaluation uses the methodology described in the ISO 13788 (2012) standard. The methodology employed in this study consists of the conduction of computational simulations of a vertical enclosure within the LSF system using the THERM software. The evaluated configuration presented a risk of surface condensation in both regions. Among the strategies to reduce the effects of thermal bridges and the consequent risk of condensation in the panels, the one that presented the best results is the application of EPS thermal break strips.

  • Open Access

    Avaliação do comportamento térmico e acústico de contêineres utilizados como edificações no canteiro de obras

    by Luiza Duarte de Freitas, Thomás Miranda Guzella Oliveira, Adriano Pinto Gomes, Rovadávia Aline de Jesus Ribas, Carmem Miranda Lage, Clécio Magalhães Do Vale

    No Brasil, a tecnologia do contêiner como sistema de construção possui o uso preservado em canteiros de obras, como escritórios, almoxarifado e estocagem de materiais e ferramentas. No entanto, observam-se poucos trabalhos de abordagens experimentais focadas na análise do comportamento térmico e acústico de contêineres usados como edificações. Desse modo, o objetivo deste trabalho é avaliar o comportamento térmico e acústico de contêineres utilizados como área de apoio em canteiros de obra, realizando medições das variáveis térmicas e acústicas in loco. Por meio de uma pesquisa empírica, foram analisados três contêineres de 20 pés (dimensões externas de 2,438 m de largura × 2,591 m de altura × 6,058 m de comprimento), situados na zona bioclimática 3, adaptados como escritório, com banheiro e depósito de materiais, no canteiro de obras. As variáveis térmicas “temperatura do ar” e “temperatura superficial dos fechamentos verticais” e os níveis de pressão sonora internos e externos foram obtidos por meio de medições in loco baseadas em normas nacionais. Os resultados obtidos permitem concluir que, em relação ao desempenho térmico, o uso de revestimento interno com camada de lã de vidro nas paredes e na cobertura implica em uma variação significativa entre a temperatura máxima interna e a externa. Mas vale ressaltar que, em condições de infiltração de ar na edificação, essa estratégia não é capaz de garantir desempenho térmico adequado para a zona bioclimática 3, sendo necessário algum tipo de sistema de condicionamento artificial. Já a composição dos fechamentos com camada isolante proporciona qualidade acústica ao ambiente, mantendo os níveis de pressão sonora abaixo de valores limites especificados pelas normas nacionais.


  • Open Access

    Simulação termoenergética e lumínica de fachadas com brises no clima tropical

    by Luma de Souza Dias, Henor Artur de Souza, Adriano Pinto Gomes, Lucas Fonseca Caetano, Bruno Henrique Lourenço Camargos, Arlindo Tribess

    O uso da luz natural em edificações é uma importante estratégia de projeto pois minimiza o consumo de energia com iluminação elétrica e proporciona maior qualidade visual para seus usuários. Porém, essa estratégia pode resultar em ganhos térmicos excessivos e ofuscamento, causando desconforto térmico em ambientes de trabalho. No intuito de buscar uma combinação entre qualidade visual e bom desempenho termoenergético e lumínico, analisa-se nesse estudo a influência do tipo de brise soleil e tipo de vidro, aplicados a uma edificação comercial com fachada envidraçada, localizada em regiões de clima tropical. Inclui-se na análise a edificação sem o uso do brise soleil, como referência. São realizadas simulações computacionais com os programas Daysim e EnergyPlus considerando-se a fachada oeste da edificação. Ao considerar o parâmetro tipo de vidro, os modelos que apresentam melhor comportamento são aqueles com vidro comum. Comparando-se os resultados entre os tipos de brises percebe-se que os modelos com brise vertical possuem valores mais elevados de taxa de radiação solar do que os modelos com brise horizontal, trazendo benefícios de maior luz natural ao ambiente. Os resultados, considerando-se as horas de conforto do usuário, indicam que o modelo de brise horizontal com vidro laminado na cor verde apresenta-se como o mais adequado, visto que possui o menor consumo de energia e mais horas de conforto. Ressalta-se, como contribuição do presente trabalho, a obtenção de modelos de brises mais adequados para projetos de brises aplicados em fachadas envidraçadas em regiões de clima tropical.


  • Open Access

    Análise do desempenho térmico da escola municipal do projeto de reassentamento de Bento Rodrigues, Mariana-MG

    by Adriano Pinto Gomes, Raissa Martins da Silva Araujo, Rovadavia Aline de Jesus Ribas, Carmem Miranda Lage

    The study of the thermal behavior of buildings has shown itself to be increasingly important in the search for a thermally balanced environment, favoring the comfort of users and, consequently, greater performance in the activities to be developed on site. The objective of this work is to evaluate the thermal performance of the Escola Municipal de Bento Rodrigues. It also seeks to analyze design strategies that impact the thermal performance of the building, in order to support decisions in the execution of the work and in future constructions in the region. The evaluation procedure adopted in this work is based on computer simulations in the EnergyPlus program, adopting as evaluation criteria the guidelines of standard NBR 15575. The results referring to the internal temperatures, generated by the simulations in the EnergyPlus program, demonstrated that the classrooms of the Escola Municipal de Bento Rodrigues present, in general, an adequate thermal performance. In the computational simulations of the parametric analyses, it was found that, considering Bioclimatic Zone 3, the opening of the rooms must be oriented to the north or to the south; the natural ventilation of the rooms is an important condition in the removal of excess heat from the environment; the characteristics of the closures indicated by the NBR 15575 standard provide adequate thermal performance; and the choice of floor finish does not generate significant changes in the building's thermal behavior.


  • Computer simulation of moisture transfer in walls: impacts on the thermal performance of buildings

    by Mariana Tonini de Araújo, Henor Artur de Souza, Adriano Pinto Gomes

    In order to reduce electricity consumption in buildings, it is imperative to improve their thermal performance. Due to the many variables involved in thermal processes computer simulation is a consolidated method for thermal analysis. However, in many energy efficiency analyses calculus of heat conduction through the dwelling envelope does not consider moisture transportation and storage. The objective of this work was to evaluate the impacts of moisture transfer in walls on the thermal performance of naturally ventilated and artificially conditioned buildings using EnergyPlus computer simulation. This research contributed to the literature by showing the difference in thermal zone air humidity, temperature and annual energy demand (i.e. electricity consumption) when moisture effects are considered in walls. Buildings were composed of masonry and solid concrete envelopes and three numerical models were simulated: Conduction Transfer Function Model (CTF), Effective Moisture Penetration Depth Model (EMPD) and Combined Heat and Moisture Transfer Model (HAMT). The CTF model does not consider moisture effects. Results found a higher relative air humidity for the studied thermal zone by applying the HAMT model in the numerical simulation, and the envelope porosity was proven to affect HAMT humidity results. Comparing the HAMT and EMPD models with the CTF model, the annual energy demanded for cooling presented a 21% reduction for the EMPD model in the masonry and 9% increase for the HAMT model in the solid concrete. This article shows the importance of an accurate EnergyPlus heat transfer model for simulating a whole building to check edification attendance of minimum comfort parameters and select envelope materials aiming the reduction of electricity consumption.


  • Open Access

    Naturally ventilated industrial sheds: an investigation about the influence of wind direction in flow rate efficiency in continuous roof vents

    by Bruno Henrique Lourenço Camargos, Henor DE Souza, Adriano Gomes, Artur Ladeira, Reinaldo Antonio dos Reis, Lidianne de Paula Pinto Mapa

    Natural ventilation portrays an effective technique for lowering the internal temperature, without spending electricity, and directly contributes to the renewal of indoor air by establishing a healthy environment for workers. Given this, it is usual to have air vent openings located at the top of the roof (continuous roof vents), in addition to those present on the facades of sheds. In naturally ventilated buildings, it is recommended to give due importance to the provision of these openings, since depending on the proposed arrangement, the wind may or may not help in the effectiveness of this strategy. In this work, it is evaluated via computer simulation (EnergyPlus, version 8.7.0), for the climatic conditions of the city of Belo Horizonte/Brazil, the influence of the wind direction in the flow rate of indoor air through the ridge vents, of the longitudinal and transversal type, present in industrial sheds endowed with an internal source of high-intensity heat release. The results obtained show that the flow rate has a symmetrical behavior in the openings of the longitudinal continuous roof vent, that is, when an opening is with the maximum outflow of the internal air, the opening opposite the predominant wind direction is acting as an entry point for the air external. The transverse continuous roof vents are more sensitive about the wind direction since they are positioned perpendicular to the building. The best result found is for the wind situation occurring parallel to the shed, obtaining a reduction in the internal temperature of up to 1°C, an increase in the rate of air changes per hour, in the internal environment, at 1acph, and an increase of up to 10,7% in the volume of air infiltrated into the shed.


  • Open Access

    Influência de paredes verdes no desempenho térmico de habitações sociais

    by Luana Resende de Sousa, Henor Artur de Souza, Adriano Pinto Gomes

    A utilização da vegetação como elemento de fachada ainda compreende uma prática bastante incipiente, mas tem se popularizado devido à promessa de melhoria no desempenho térmico das edificações, além de representar uma alternativa de ampliação da biodiversidade no ambiente urbano. Neste trabalho investiga-se a influência das paredes verdes, no contexto climático brasileiro, sobre o desempenho térmico de edifícios habitacionais de interesse social. Como metodologia, utiliza-se a simulação do comportamento termoenergético de um edifício habitacional multifamiliar, por meio d­o programa EnergyPlus, incluindo-se o modelo HAMT que leva em conta o processo de transferência de umidade através da envoltória, para três zonas bioclimáticas previstas na norma NBR 15.220-2005, clima extremo para inverno (ZB1), clima extremo de verão (ZB8) e para um clima considerado como intermediário (ZB3). Os resultados obtidos demonstram uma diferença na temperatura interna dos ambientes, decorrente dos dois arranjos de fachada analisados: com e sem vegetação. O uso da parede verde proporcionou uma redução na temperatura interna de até 2,8 °C no verão e um aumento de até 1,4 °C no inverno. Observa-se que a vegetação na fachada ajudou a manter a temperatura interna mais baixa durante o dia e amena durante a noite. Logo, as paredes verdes podem representar uma solução sustentável e de baixo custo a ser implantada às edificações, visando melhorar seu desempenho térmico.


  • Open Access

    Analysis of the influence of soil in the thermal performance of subterranean rooms in a ground-level building in Sao Paulo, Brazil, via EnergyPlus

    by Bruna Cristina Resende, Henor Artur de Souza, Adriano Pinto Gomes

    Among the several factors that interfere with the thermal performance of buildings, soil temperature is not always considered in thermal performance evaluations. However, soil temperature is a factor that influences the result of heat exchanges in the environment, especially in ground-level buildings. Thus, it is necessary to evaluate this influence due to the interaction of the soil with the building. In addition, due to the three-dimensional and transient character of the heat exchange processes involving the ground, the numerical approach becomes an important tool in the thermal performance analysis of buildings. In this respect, the software EnergyPlus emerges as an alternative to obtain such results, especially through the Basement preprocessor. Results suggest that, when the soil effect is considered in thermal analyses, the internal temperature of subterranean rooms increases up to 8.9% in the summer and decreases to 5.4% in winter. These results were obtained when compared to the initial situation, where soil influence had been neglected. Such results provide an indication of the importance of considering the soil influence on the thermal performance analyses where an accurate assessment is requested.


  • Open Access

    Residência em contêiner: comparativo de estratégias para a melhoria do desempenho térmico

    by Françoíse Santana Viana, Henor Artur de Souza, Adriano Pinto Gomes

    A construção civil passa atualmente por desafios em construir de forma mais econômica e ambientalmente correta. Neste trabalho visa-se conhecer melhor o equipamento não convencional utilizado para edificações, o contêiner, avaliando seu desempenho térmico. O contêiner é escolhido como objeto de estudo pois é um módulo que pode ser adaptado para diversos tipos de climas, terrenos e construções. E como no Brasil sua utilização na construção é recente, torna-se necessário uma análise para entender como adaptá-lo de forma eficiente. Neste estudo, a avaliação do desempenho térmico do contêiner é feita via simulação numérica utilizando o programa Energyplus, analisando o impacto da ventilação natural e da massa térmica dos fechamentos no comportamento térmico da edificação. São consideradas as condições climáticas para as zonas bioclimáticas 2, 3 e 8, que englobam o litoral brasileiro, previstas na norma NBR 15.220-2005, observando também os requisitos mínimos da norma NBR 15.575-2013. Para o estudo, projetou-se uma casa com dois módulos de contêiner, totalizando uma área de 29,57 m². Os resultados obtidos mostram a necessidade de adaptações para que o contêiner possua habitabilidade em todas as zonas bioclimáticas analisadas. Constata-se que o uso de isolamento térmico nos fechamentos verticais, de uma cobertura termicamente eficiente, de uma fundação adequada e de cores com tons mais claros no fechamento externo proporcionam um melhor desempenho térmico à edificação, para os climas analisados.