Guanyun Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guanyun Yan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Qiang Tian
State Key Laboratory of Environment-Friendly Energy Materials, School of Materials and Chemistry, Southwest University of Science and Technology, Mianyang 621010, China
3 shared publications - Bo Chen
Key Laboratory of Neutron Physics and Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621999, People's Republic of China
2 shared publications - Chaoqiang Huang
Key Laboratory of Neutron Physics and Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621999, People's Republic of China
2 shared publications - Guangai Sun
Institute of Nuclear Physics and Chemistry China Academy of Engineering Physics (CAEP) 621999 Mianyang P R China
2 shared publications - Liangfei Bai
Key Laboratory of Neutron Physics and Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621999, People's Republic of China
2 shared publications - László Almásy
Institute for Energy Security and Environmental Safety, HUN-REN Centre for Energy Research, Konkoly-Thege Miklós út 29-33, 1121 Budapest, Hungary
2 shared publications
Latest Publications
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1252-1260
Design of a three-detector system on LUOSHU: a small-angle neutron scattering instrument at China Mianyang Research Reactor
The LUOSHU small-angle neutron scattering instrument is one of the neutron scattering instruments under construction at the China Mianyang Research Reactor. Research interests in the fields of materials science, physics, chemistry and biology require that LUOSHU provide a wide range of measured scattering vector magnitudes (Q), a large dynamic Q range and high resolution. A movable and combined three-detector system that consists of a high-resolution position-sensitive 3He multi-tube rear detector and two L-shaped front detectors is designed in order to expand the Q range and dynamic Q. Analytical calculations validate that, with the three-detector system, LUOSHU can cover a Q range of four orders of magnitude. Also, the three-detector system will extend the dynamic Q range and provide simultaneous Q max/Q min higher than 800 in operation, satisfying the requirements of in situ experiments.
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1252-1260
Design of a three-detector system on LUOSHU: a small-angle neutron scattering instrument at China Mianyang Research Reactor
The LUOSHU small-angle neutron scattering instrument is one of the neutron scattering instruments under construction at the China Mianyang Research Reactor. Research interests in the fields of materials science, physics, chemistry and biology require that LUOSHU provide a wide range of measured scattering vector magnitudes (Q), a large dynamic Q range and high resolution. A movable and combined three-detector system that consists of a high-resolution position-sensitive 3He multi-tube rear detector and two L-shaped front detectors is designed in order to expand the Q range and dynamic Q. Analytical calculations validate that, with the three-detector system, LUOSHU can cover a Q range of four orders of magnitude. Also, the three-detector system will extend the dynamic Q range and provide simultaneous Q max/Q min higher than 800 in operation, satisfying the requirements of in situ experiments.
- 22 November 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (6) , 1662-1670
Calibration of the Suanni small-angle neutron scattering instrument at the China Mianyang Research Reactor
A series of calibration measurements have been performed on Suanni – the first small-angle neutron scattering spectrometer entering into routine user operation in China – aiming to characterize instrument performance and to provide a reference for user experiments. Various calibration standards were used to verify the precise association of the scattering intensity I with the scattering vector magnitude q at short and medium sample–detector distances. The measurements recorded for silver behenate powder revealed a slight shift of the neutron wavelength (λ) at the sample position as compared to the nominal λ calculated by the selector constant. The deviation was more significant with λ > 0.8 nm owing to the shape of the incoming neutron spectrum incident on the selector. The measured dead time for the entire detection system is 2.7 µs, as determined by measurements with varying fluxes. A protonated/deuterated polystyrene blend was employed as the primary standard to calibrate the secondary standard H2O. The instrument covers an effective q range between 0.013 and 5 nm−1, as demonstrated by scattering curves obtained from a monodisperse poly(methyl methacrylate) nanoparticle suspension and a glassy carbon plate.
- 22 November 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (6) , 1662-1670
Calibration of the Suanni small-angle neutron scattering instrument at the China Mianyang Research Reactor
A series of calibration measurements have been performed on Suanni – the first small-angle neutron scattering spectrometer entering into routine user operation in China – aiming to characterize instrument performance and to provide a reference for user experiments. Various calibration standards were used to verify the precise association of the scattering intensity I with the scattering vector magnitude q at short and medium sample–detector distances. The measurements recorded for silver behenate powder revealed a slight shift of the neutron wavelength (λ) at the sample position as compared to the nominal λ calculated by the selector constant. The deviation was more significant with λ > 0.8 nm owing to the shape of the incoming neutron spectrum incident on the selector. The measured dead time for the entire detection system is 2.7 µs, as determined by measurements with varying fluxes. A protonated/deuterated polystyrene blend was employed as the primary standard to calibrate the secondary standard H2O. The instrument covers an effective q range between 0.013 and 5 nm−1, as demonstrated by scattering curves obtained from a monodisperse poly(methyl methacrylate) nanoparticle suspension and a glassy carbon plate.
- Open Access
Microstructure Changes in Polyester Polyurethane upon Thermal and Humid Aging
The microstructure of compression molded Estane 5703 films exposed to 11%, 45%, and 80% relative humidity and 70 °C for 1 and 2 months has been studied by small-angle neutron scattering (SANS), Fourier transform infrared spectroscopy (FTIR), gel permeation chromatography (GPC), and differential scanning calorimetry (DSC). Scattering data indicated increase of the interdomain distance and domain size with a higher humidity and longer aging time. GPC data showed a progressive shortening of polyurethane chains with increasing humidity and aging time. The shortening of the polyurethane chains caused a drop of the glass transition temperature of soft segments, and promoted crystallization of the soft segments during long-time storage of the aged samples at room temperature. FTIR showed a substantial increase in the number of inter-urethane H-bonds in the aged samples. This correlates with the increase of the hard domain size and the degree of phase separation as measured by SANS. The data collected reveals that the reduced steric hindrance caused by hydrolysis of ester links in polybutylene adipate residues promotes the organization of hard segments into domains, leading to the increase of domain size and distance, as well as phase segregation in aged Estane. These findings provide insight into the effects of humidity and thermal aging on the microstructure of aged polyester urethane from molecular to nanoscale level.
Open AccessMicrostructure Changes in Polyester Polyurethane upon Thermal and Humid Aging
The microstructure of compression molded Estane 5703 films exposed to 11%, 45%, and 80% relative humidity and 70 °C for 1 and 2 months has been studied by small-angle neutron scattering (SANS), Fourier transform infrared spectroscopy (FTIR), gel permeation chromatography (GPC), and differential scanning calorimetry (DSC). Scattering data indicated increase of the interdomain distance and domain size with a higher humidity and longer aging time. GPC data showed a progressive shortening of polyurethane chains with increasing humidity and aging time. The shortening of the polyurethane chains caused a drop of the glass transition temperature of soft segments, and promoted crystallization of the soft segments during long-time storage of the aged samples at room temperature. FTIR showed a substantial increase in the number of inter-urethane H-bonds in the aged samples. This correlates with the increase of the hard domain size and the degree of phase separation as measured by SANS. The data collected reveals that the reduced steric hindrance caused by hydrolysis of ester links in polybutylene adipate residues promotes the organization of hard segments into domains, leading to the increase of domain size and distance, as well as phase segregation in aged Estane. These findings provide insight into the effects of humidity and thermal aging on the microstructure of aged polyester urethane from molecular to nanoscale level.