Ahmed E. B. Abu-Elanien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ahmed E. B. Abu-Elanien has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
M. M. A. Salama
University of Waterloo
8 shared publications- Ahmed Mohammed Massoud
Department of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar
5 shared publications - Ayman Samy Abdel-Khalik
Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat 123, Oman
5 shared publications Shehab Ahmed
CEMSE Division, King Abdullah University of Science and Technology, Thuwal, Saudi Arabia
5 shared publicationsAhmed A. Elserougi
Electrical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt
3 shared publicationsM.M.A. Salama
3 shared publications
Latest Publications
- Open Access
- 12 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (5) , 3313-3324
High frequency-based protection algorithm for meshed MTDC systems
This research presents a high frequency-based algorithm for zonal protection of meshed Multi-Terminal high voltage Direct Current (MTDC) systems. Discrete wavelet transform (DWT) is used to capture high frequency current transients from one end of each line. The faulty line is identified by analyzing two distinct high frequency bands form the captured transients. The characteristics of these current transients during normal condition are different from faulty condition. A four-terminal meshed MTDC model is used to test the performance of the protection algorithm. Various faults with different fault scenarios were simulated using four-terminal meshed MTDC model. The simulation results showed success of the algorithm in identifying internal faults. Moreover, the high frequency algorithm showed robustness against other abnormal conditions such as AC faults and sudden change of wind power.
- 12 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (5) , 3313-3324
Open AccessHigh frequency-based protection algorithm for meshed MTDC systems
This research presents a high frequency-based algorithm for zonal protection of meshed Multi-Terminal high voltage Direct Current (MTDC) systems. Discrete wavelet transform (DWT) is used to capture high frequency current transients from one end of each line. The faulty line is identified by analyzing two distinct high frequency bands form the captured transients. The characteristics of these current transients during normal condition are different from faulty condition. A four-terminal meshed MTDC model is used to test the performance of the protection algorithm. Various faults with different fault scenarios were simulated using four-terminal meshed MTDC model. The simulation results showed success of the algorithm in identifying internal faults. Moreover, the high frequency algorithm showed robustness against other abnormal conditions such as AC faults and sudden change of wind power.
- Open Access
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 92661-92675
Multi-Terminal HVDC System With Offshore Wind Farms Under Anomalous Conditions: Stability Assessment
Droop control is widely adopted to control Multi-Terminal high-voltage Direct Current (MTDC) systems with offshore wind farms. During permanent faults, the faulty line should be isolated promptly to preserve a high reliability of the MTDC system. This paper examines the MTDC system performance following a faulty line outage. This study aims to identify the outage types that may lead to a complete loss of system voltage stability and the outages that may have a secondary effect on the system. Moreover, strategies for dealing with outages that may lead to a complete shutdown of the system are also presented. Furthermore, the ranges of droop gains’ values that can be employed following fault occurrence to preserve system transient stability are studied. Different scenarios are explored during faulty conditions such as surplus and sparsity of wind power, line overcurrent, outage of lines connected to wind farms, and outage of lines connected to AC grids to validate this study. MATLAB/Simulink platform has been employed to elucidate the presented concept.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 92661-92675
Open AccessMulti-Terminal HVDC System With Offshore Wind Farms Under Anomalous Conditions: Stability Assessment
Droop control is widely adopted to control Multi-Terminal high-voltage Direct Current (MTDC) systems with offshore wind farms. During permanent faults, the faulty line should be isolated promptly to preserve a high reliability of the MTDC system. This paper examines the MTDC system performance following a faulty line outage. This study aims to identify the outage types that may lead to a complete loss of system voltage stability and the outages that may have a secondary effect on the system. Moreover, strategies for dealing with outages that may lead to a complete shutdown of the system are also presented. Furthermore, the ranges of droop gains’ values that can be employed following fault occurrence to preserve system transient stability are studied. Different scenarios are explored during faulty conditions such as surplus and sparsity of wind power, line overcurrent, outage of lines connected to wind farms, and outage of lines connected to AC grids to validate this study. MATLAB/Simulink platform has been employed to elucidate the presented concept.
- 15 June 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (9-10) , 772-784
Design of Optimal Droop Control for Multi-Terminal High-Voltage Direct Current Systems During Line Outages
This article investigates the required modifications to droop control design for optimum operation of Multi-Terminal High-Voltage Direct Current (MTHVDC) systems during line and converter outages. A typical 6-bus MTHVDC system is used in this study. Different scenarios are considered during the design process such as different outage types, violation of power ratings of system components, and variability of wind power injected into the system. A variable droop control gains technique is proposed to ensure minimum power loss and maximum annual energy collection. The study is extended to investigate the effect of employing constant droop control gains calculated during rated conditions on the system performance. Moreover, the results of the constant and the proposed variable droop gain schemes are compared. Simulation results show the effectiveness of the proposed techniques for designing optimum droop gains during abnormal conditions. Additionally, general guidelines are presented for the implementation of the proposed techniques.
- 15 June 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (9-10) , 772-784
Design of Optimal Droop Control for Multi-Terminal High-Voltage Direct Current Systems During Line Outages
This article investigates the required modifications to droop control design for optimum operation of Multi-Terminal High-Voltage Direct Current (MTHVDC) systems during line and converter outages. A typical 6-bus MTHVDC system is used in this study. Different scenarios are considered during the design process such as different outage types, violation of power ratings of system components, and variability of wind power injected into the system. A variable droop control gains technique is proposed to ensure minimum power loss and maximum annual energy collection. The study is extended to investigate the effect of employing constant droop control gains calculated during rated conditions on the system performance. Moreover, the results of the constant and the proposed variable droop gain schemes are compared. Simulation results show the effectiveness of the proposed techniques for designing optimum droop gains during abnormal conditions. Additionally, general guidelines are presented for the implementation of the proposed techniques.
- 17 May 2019
- Published by Springer Nature in Electrical Engineering
- Vol. 101 (2) , 357-368
Evaluation of transformer health condition using reduced number of tests
- 17 May 2019
- Published by Springer Nature in Electrical Engineering
- Vol. 101 (2) , 357-368
Evaluation of transformer health condition using reduced number of tests
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1004-1009
An Artificial Neural Network Based Technique for Protection of HVDC Grids
This paper presents a reliable technique for protection of multi-terminal HVDC systems. The method relies on analyzing the current signals at one end in each section. The protection decision is taken by a feed forward artificial neural network (ANN). The inputs to the ANN are the energy contained in two different frequency bands of the spectrum of the current, and the rate of change of current signal following fault inception for both positive and negative poles (a total of six inputs). The energy indices and the rates of change of positive and negative poles' currents are calculated in a duration of 1 ms following fault inception. The technique is tested on a three-terminal HVDC system and the results where reliable.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1004-1009
An Artificial Neural Network Based Technique for Protection of HVDC Grids
This paper presents a reliable technique for protection of multi-terminal HVDC systems. The method relies on analyzing the current signals at one end in each section. The protection decision is taken by a feed forward artificial neural network (ANN). The inputs to the ANN are the energy contained in two different frequency bands of the spectrum of the current, and the rate of change of current signal following fault inception for both positive and negative poles (a total of six inputs). The energy indices and the rates of change of positive and negative poles' currents are calculated in a duration of 1 ms following fault inception. The technique is tested on a three-terminal HVDC system and the results where reliable.
- Open Access
- 1 December 2018
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 57 (4) , 3959-3967
Modern network reconfiguration techniques for service restoration in distribution systems: A step to a smarter grid
- 1 December 2018
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 57 (4) , 3959-3967
Open AccessModern network reconfiguration techniques for service restoration in distribution systems: A step to a smarter grid
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Protection of star connected multi-terminal HVDC systems with offshore wind farms
In this paper, a high speed protection technique is proposed for protection of star connected Multi-Terminal HVDC (MTHVDC) systems with offshore wind farms. The fault is detected using high frequency transients created in the current signals due to fault occurrence. In fault cases, the energy of the transients superimposed on current signals is high. Moreover, the faulty line incorporates more high frequency transients than the healthy lines. Therefore, faulted line can be identified by comparing Euclidean norms of the high frequency transients superimposed on line currents. The proposed technique is able to detect fault and identify faulted line in MTHVDC systems including overhead lines and underground cables. Moreover, the identification of faulted line is done in less than 0.1 ms, which means complete safety of converter semiconductor devices during fault. Simulation and relay design are done in MATLAB. Simulation results showed the robustness and reliability of the proposed algorithm.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Protection of star connected multi-terminal HVDC systems with offshore wind farms
In this paper, a high speed protection technique is proposed for protection of star connected Multi-Terminal HVDC (MTHVDC) systems with offshore wind farms. The fault is detected using high frequency transients created in the current signals due to fault occurrence. In fault cases, the energy of the transients superimposed on current signals is high. Moreover, the faulty line incorporates more high frequency transients than the healthy lines. Therefore, faulted line can be identified by comparing Euclidean norms of the high frequency transients superimposed on line currents. The proposed technique is able to detect fault and identify faulted line in MTHVDC systems including overhead lines and underground cables. Moreover, the identification of faulted line is done in less than 0.1 ms, which means complete safety of converter semiconductor devices during fault. Simulation and relay design are done in MATLAB. Simulation results showed the robustness and reliability of the proposed algorithm.
- 1 March 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 144, 41-51
A non-communication based protection algorithm for multi-terminal HVDC grids
- 1 March 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 144, 41-51
A non-communication based protection algorithm for multi-terminal HVDC grids
- 1 January 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 130, 78-88
A differential protection technique for multi-terminal HVDC
- 1 January 2016
- Published by Elsevier in Electric Power Systems Research
- Vol. 130, 78-88
A differential protection technique for multi-terminal HVDC
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A directional protection technique for MTDC networks
This paper suggests a new protection algorithm for a multi-terminal direct current (MTDC) networks. The current values and directions at each bus connecting more than one line are determined. The measured values of line currents are used to detect faulty conditions based on a specific threshold value. The faulted line is identified using the current direction through each line during a fault. For lines linking buses that connect multiple lines, simple communication system is required between the ends of these lines to identify an internal fault. The communication time is compensated due to the fast decision. Communication between buses is not required during normal conditions; therefore, the communication task is simplified. Simulation results show that the proposed algorithm is effective in protection of MTDC.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A directional protection technique for MTDC networks
This paper suggests a new protection algorithm for a multi-terminal direct current (MTDC) networks. The current values and directions at each bus connecting more than one line are determined. The measured values of line currents are used to detect faulty conditions based on a specific threshold value. The faulted line is identified using the current direction through each line during a fault. For lines linking buses that connect multiple lines, simple communication system is required between the ends of these lines to identify an internal fault. The communication time is compensated due to the fast decision. Communication between buses is not required during normal conditions; therefore, the communication task is simplified. Simulation results show that the proposed algorithm is effective in protection of MTDC.