Matthias Koegl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matthias Koegl has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Lars Zigan
Institut für Thermodynamik, Professur für Energiewandlung, Fakultät für Luft- und Raumfahrttechnik, Universität der Bundeswehr München (UniBw M), D-85577 Neubiberg, Germany
7 shared publications - Stefan Will
Lehrstuhl für Technische Thermodynamik (LTT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
4 shared publications Kevin Baderschneider
Lehrstuhl für Technische Thermodynamik (LTT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2 shared publications- Kevin Baderschneider
Lehrstuhl für Technische Thermodynamik (LTT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany
2 shared publications Yogeshwar Nath Mishra
Lehrstuhl für Technische Thermodynamik (LTT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2 shared publications- Ajeth Yoganantham
Lehrstuhl für Technische Thermodynamik, FAU Erlangen-Nürnberg, 91058 Erlangen, Germany
1 shared publication
Latest Publications
- Open Access
Fluorescence Spectroscopy for Studying Evaporating Droplets Using the Dye Eosin-Y
Laser-induced fluorescence (LIF) spectroscopy using dyes is frequently applied for characterization of liquids and two-phase flows. The technique is utilized e.g., for mixing studies, thermometry, or droplet sizing. One major application of the LIF technique combined with Mie-scattering is the planar measurement of droplet sizes in spray systems. However, its uncertainty is determined, among others, by varying dye concentration and temperature changes occurring during mixing and droplet evaporation. Systematic experimental investigations are necessary to determine the influence of dye enrichment effects on the LIF-signal of single droplets. For these investigations, the fluorescence dye Eosin-Y is dissolved in water and ethanol, which are typical solvents and working fluids in bio-medical applications and power engineering. A photo-physical characterization of the mixtures under various conditions was conducted using a spectrometric LIF setup and a micro cell. For ethanol, a small temperature dependency of the Eosin-Y LIF signal is observed up to 373 K. Photo-dissociation of Eosin-Y is negligible for solution in ethanol while it is distinct in water. The LIF signals of the single droplets are studied with an acoustic levitator. Effects of droplet evaporation, droplet deformation and varying dye concentration on the LIF-signal are studied. The single droplet measurements revealed a complex change of the fluorescence signal with reduced droplet size. This is due to droplet deformations leading to variations in the internal illumination field as well as dye enrichment during evaporation.
Open AccessFluorescence Spectroscopy for Studying Evaporating Droplets Using the Dye Eosin-Y
Laser-induced fluorescence (LIF) spectroscopy using dyes is frequently applied for characterization of liquids and two-phase flows. The technique is utilized e.g., for mixing studies, thermometry, or droplet sizing. One major application of the LIF technique combined with Mie-scattering is the planar measurement of droplet sizes in spray systems. However, its uncertainty is determined, among others, by varying dye concentration and temperature changes occurring during mixing and droplet evaporation. Systematic experimental investigations are necessary to determine the influence of dye enrichment effects on the LIF-signal of single droplets. For these investigations, the fluorescence dye Eosin-Y is dissolved in water and ethanol, which are typical solvents and working fluids in bio-medical applications and power engineering. A photo-physical characterization of the mixtures under various conditions was conducted using a spectrometric LIF setup and a micro cell. For ethanol, a small temperature dependency of the Eosin-Y LIF signal is observed up to 373 K. Photo-dissociation of Eosin-Y is negligible for solution in ethanol while it is distinct in water. The LIF signals of the single droplets are studied with an acoustic levitator. Effects of droplet evaporation, droplet deformation and varying dye concentration on the LIF-signal are studied. The single droplet measurements revealed a complex change of the fluorescence signal with reduced droplet size. This is due to droplet deformations leading to variations in the internal illumination field as well as dye enrichment during evaporation.
- Open Access
A Novel Approach for Measurement of Composition and Temperature of N-Decane/Butanol Blends Using Two-Color Laser-Induced Fluorescence of Nile Red
In this work, the possibility of using a two-color LIF (laser-induced fluorescence) approach for fuel composition and temperature measurements using nile red dissolved in n-decane/butanol blends is investigated. The studies were conducted in a specially designed micro cell enabling the detection of the spectral LIF intensities over a wide range of temperatures (283–423 K) and butanol concentrations (0–100 vol.%) in mixtures with n-decane. Furthermore, absorption spectra were analyzed for these fuel mixtures. At constant temperature, the absorption and LIF signals exhibit a large spectral shift toward higher wavelengths with increasing butanol concentration. Based on this fact, a two-color detection approach is proposed that enables the determination of the butanol concentration. This is reasonable when temperature changes and evaporation effects accompanied with dye enrichment can be neglected. For n-decane, no spectral shift and broadening of the spectrum are observed for various temperatures. However, for butanol admixture, two-color thermometry is possible as long as the dye and butanol concentrations are kept constant. For example, the LIF spectrum shows a distinct broadening for B20 (i.e., 80 vol.% n-decane, 20 vol.% butanol) and a shift of the peak toward lower wavelengths of about 40 nm for temperature variations of 140 K.
Open AccessA Novel Approach for Measurement of Composition and Temperature of N-Decane/Butanol Blends Using Two-Color Laser-Induced Fluorescence of Nile Red
In this work, the possibility of using a two-color LIF (laser-induced fluorescence) approach for fuel composition and temperature measurements using nile red dissolved in n-decane/butanol blends is investigated. The studies were conducted in a specially designed micro cell enabling the detection of the spectral LIF intensities over a wide range of temperatures (283–423 K) and butanol concentrations (0–100 vol.%) in mixtures with n-decane. Furthermore, absorption spectra were analyzed for these fuel mixtures. At constant temperature, the absorption and LIF signals exhibit a large spectral shift toward higher wavelengths with increasing butanol concentration. Based on this fact, a two-color detection approach is proposed that enables the determination of the butanol concentration. This is reasonable when temperature changes and evaporation effects accompanied with dye enrichment can be neglected. For n-decane, no spectral shift and broadening of the spectrum are observed for various temperatures. However, for butanol admixture, two-color thermometry is possible as long as the dye and butanol concentrations are kept constant. For example, the LIF spectrum shows a distinct broadening for B20 (i.e., 80 vol.% n-decane, 20 vol.% butanol) and a shift of the peak toward lower wavelengths of about 40 nm for temperature variations of 140 K.
- Open Access
- 9 September 2020
- Published by Springer Nature in Experiments in Fluids
- Vol. 61 (10) , 1-20
Planar droplet sizing for studying the influence of ethanol admixture on the spray structure of gasoline sprays
A novel planar droplet sizing (PDS) technique based on laser-induced fluorescence (LIF) and Mie-scattering is utilized for the characterization of the spray structure under gasoline direct-injection spark-ignition (DISI) conditions. Fuel effects on the spray structure and cyclic variations are studied for a gasoline surrogate fuel (Toliso, consisting of 65 vol.% isooctane and 35 vol.% toluene) and the gasoline-ethanol blend E20 (20 vol.% ethanol admixture). Sauter mean diameter (SMD) results are compared with those from phase-Doppler anemometry (PDA) measurements showing good agreement especially at early points in time (up to 1.2 ms after start of injection). The liquid spray propagation and SMD are very similar for both fuels indicating similar atomization behavior. Both investigated fuels show comparable cyclic variations of the spray shape. A larger width and slightly larger droplet sizes are observed for the E20 spray when stronger evaporation occurs (at 2 ms). At these later points in time, the PDS-measured droplet sizes differ from the PDA-results. Here the limitation of the PDS-technique becomes obvious as a partial evaporation of the droplets may lead to large systematic errors. A numerical simulation of single droplets is provided for clarification of issues of droplet evaporation in PDS. Graphic
- 9 September 2020
- Published by Springer Nature in Experiments in Fluids
- Vol. 61 (10) , 1-20
Open AccessPlanar droplet sizing for studying the influence of ethanol admixture on the spray structure of gasoline sprays
A novel planar droplet sizing (PDS) technique based on laser-induced fluorescence (LIF) and Mie-scattering is utilized for the characterization of the spray structure under gasoline direct-injection spark-ignition (DISI) conditions. Fuel effects on the spray structure and cyclic variations are studied for a gasoline surrogate fuel (Toliso, consisting of 65 vol.% isooctane and 35 vol.% toluene) and the gasoline-ethanol blend E20 (20 vol.% ethanol admixture). Sauter mean diameter (SMD) results are compared with those from phase-Doppler anemometry (PDA) measurements showing good agreement especially at early points in time (up to 1.2 ms after start of injection). The liquid spray propagation and SMD are very similar for both fuels indicating similar atomization behavior. Both investigated fuels show comparable cyclic variations of the spray shape. A larger width and slightly larger droplet sizes are observed for the E20 spray when stronger evaporation occurs (at 2 ms). At these later points in time, the PDS-measured droplet sizes differ from the PDA-results. Here the limitation of the PDS-technique becomes obvious as a partial evaporation of the droplets may lead to large systematic errors. A numerical simulation of single droplets is provided for clarification of issues of droplet evaporation in PDS. Graphic
- Open Access
Investigation of Five Organic Dyes in Ethanol and Butanol for Two-Color Laser-Induced Fluorescence Ratio Thermometry
In this article, we compare absorption and temperature-dependent fluorescence spectra of five organic dyes for 2c-LIF (two-color laser-induced fluorescence) thermometry in ethanol and butanol. The dyes fluorescein, eosin Y, rhodamine B, rhodamine 6G, and sulforhodamine 101 individually mixed in ethanol and butanol were studied at liquid temperatures of 25–65 °C. The self-absorption spectral bands are analyzed along with intensity ratios and the respective sensitivities for one-dye and two-dye 2c-LIF thermometry are deduced. For one-dye 2c-LIF, rhodamine B showed the highest sensitivity of 2.93%/°C and 2.89%/°C in ethanol and butanol, respectively. Sulforhodamine 101 and rhodamine 6G showed the least sensitivities of 0.51%/°C and 1.24%/°C in ethanol and butanol, respectively. For two-dye 2c-LIF, rhodamine B/sulforhodamine 101 exhibited the highest temperature sensitivities of 2.39%/°C and 2.54%/°C in ethanol and butanol, respectively. The dye pair eosin Y/sulforhodamine 101 showed the least sensitivities of 0.15%/°C and 0.27%/°C in ethanol and butanol, respectively.
Open AccessInvestigation of Five Organic Dyes in Ethanol and Butanol for Two-Color Laser-Induced Fluorescence Ratio Thermometry
In this article, we compare absorption and temperature-dependent fluorescence spectra of five organic dyes for 2c-LIF (two-color laser-induced fluorescence) thermometry in ethanol and butanol. The dyes fluorescein, eosin Y, rhodamine B, rhodamine 6G, and sulforhodamine 101 individually mixed in ethanol and butanol were studied at liquid temperatures of 25–65 °C. The self-absorption spectral bands are analyzed along with intensity ratios and the respective sensitivities for one-dye and two-dye 2c-LIF thermometry are deduced. For one-dye 2c-LIF, rhodamine B showed the highest sensitivity of 2.93%/°C and 2.89%/°C in ethanol and butanol, respectively. Sulforhodamine 101 and rhodamine 6G showed the least sensitivities of 0.51%/°C and 1.24%/°C in ethanol and butanol, respectively. For two-dye 2c-LIF, rhodamine B/sulforhodamine 101 exhibited the highest temperature sensitivities of 2.39%/°C and 2.54%/°C in ethanol and butanol, respectively. The dye pair eosin Y/sulforhodamine 101 showed the least sensitivities of 0.15%/°C and 0.27%/°C in ethanol and butanol, respectively.
- Open Access
- 15 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4900
Analysis of the LIF/Mie Ratio from Individual Droplets for Planar Droplet Sizing: Application to Gasoline Fuels and Their Mixtures with Ethanol
In this work, the possibility of using planar droplet sizing (PDS) based on laser-induced fluorescence (LIF) and Mie scattering was investigated within the framework of measuring the droplet Sauter mean diameter (SMD) of direct-injection spark-ignition (DISI) spray systems. For this purpose, LIF and Mie signals of monodisperse fuel droplets produced by a droplet generator were studied at engine relevant diameters (20–50 µm). The surrogate gasoline fuel Toliso (consisting of 65 vol. % isooctane, 35 vol. % toluene) and the biofuel blend E20 (consisting of 80 vol. % Toliso, 20 vol. % ethanol) were used and which were doped with the fluorescence dye “nile red”. The effects of ethanol admixture, dye concentration, laser power, and temperature variation on the LIF/Mie ratio were studied simultaneously at both macroscopic and microscopic scale. The deduced calibration curves of the LIF and Mie signals of both fuels showed volumetric and surface dependent behaviors, respectively, in accordance with the assumptions in the literature. The existence of glare points and morphology-dependent resonances (MDRs) lead to slightly higher LIF and Mie exponents of E20 in comparison to Toliso. In principle, these calibration curves enable the determination of the SMD from LIF/Mie ratio images of transient fuel sprays.
- 15 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4900
Open AccessAnalysis of the LIF/Mie Ratio from Individual Droplets for Planar Droplet Sizing: Application to Gasoline Fuels and Their Mixtures with Ethanol
In this work, the possibility of using planar droplet sizing (PDS) based on laser-induced fluorescence (LIF) and Mie scattering was investigated within the framework of measuring the droplet Sauter mean diameter (SMD) of direct-injection spark-ignition (DISI) spray systems. For this purpose, LIF and Mie signals of monodisperse fuel droplets produced by a droplet generator were studied at engine relevant diameters (20–50 µm). The surrogate gasoline fuel Toliso (consisting of 65 vol. % isooctane, 35 vol. % toluene) and the biofuel blend E20 (consisting of 80 vol. % Toliso, 20 vol. % ethanol) were used and which were doped with the fluorescence dye “nile red”. The effects of ethanol admixture, dye concentration, laser power, and temperature variation on the LIF/Mie ratio were studied simultaneously at both macroscopic and microscopic scale. The deduced calibration curves of the LIF and Mie signals of both fuels showed volumetric and surface dependent behaviors, respectively, in accordance with the assumptions in the literature. The existence of glare points and morphology-dependent resonances (MDRs) lead to slightly higher LIF and Mie exponents of E20 in comparison to Toliso. In principle, these calibration curves enable the determination of the SMD from LIF/Mie ratio images of transient fuel sprays.
- Open Access
Characterization of Nile Red as a Tracer for Laser-Induced Fluorescence Spectroscopy of Gasoline and Kerosene and Their Mixture with Biofuels
Suitable fluorescence tracers (“dyes”) are needed for the planar measurement of droplet sizes by using a combination of laser-induced fluorescence (LIF) and Mie scattering. Currently, no suitable tracers have been characterized for application in planar droplet sizing in gasoline and kerosene fuels, as well as biofuel blends. One promising tracer is nile red, which belongs to the fluorophore group. For its utilization for droplet size measurements, preliminary characterization of the fluorescence of the respective fuel tracer mixtures are mandatory. For this purpose, the fluorescence and absorption behavior of nile red dissolved in the surrogate fuels Toliso and Jet A-1 as well as in biofuel blends was investigated. The fluorescence signal for nile red that was dissolved in the two base fuels Toliso and Jet A-1 showed a linear behavior as a function of dye concentration. The temperature effect on spectral absorption and emission of nile red was investigated in a specially designed test cell. An ethanol admixture to Toliso led to a spectral shift towards higher wavelengths. The absorption and emission bands were shifted towards lower wavelengths with increasing temperature for all fuels. Both absorption and fluorescence decreased with increasing temperature for all fuels, except for E20, which showed an increased fluorescence signal with increasing temperature. Jet A-1 and its blends with hydroprocessed esters and fatty acids (HEFA) and farnesane did not exhibit explicit variations in spectral absorption or emission, but these blends showed a more distinct temperature dependence compared to the Toliso-ethanol-blends. The effect of photo-dissociation of the LIF signal of the fuel tracer mixtures was studied, and all fuel mixtures besides Toliso showed a more or less distinct decay in the fluorescence signal with time. In summary, all investigated fuel-tracer mixtures are suitable for LIF/Mie ratio droplet sizing in combination with nile red at moderate temperatures and low evaporation cooling rates.
Open AccessCharacterization of Nile Red as a Tracer for Laser-Induced Fluorescence Spectroscopy of Gasoline and Kerosene and Their Mixture with Biofuels
Suitable fluorescence tracers (“dyes”) are needed for the planar measurement of droplet sizes by using a combination of laser-induced fluorescence (LIF) and Mie scattering. Currently, no suitable tracers have been characterized for application in planar droplet sizing in gasoline and kerosene fuels, as well as biofuel blends. One promising tracer is nile red, which belongs to the fluorophore group. For its utilization for droplet size measurements, preliminary characterization of the fluorescence of the respective fuel tracer mixtures are mandatory. For this purpose, the fluorescence and absorption behavior of nile red dissolved in the surrogate fuels Toliso and Jet A-1 as well as in biofuel blends was investigated. The fluorescence signal for nile red that was dissolved in the two base fuels Toliso and Jet A-1 showed a linear behavior as a function of dye concentration. The temperature effect on spectral absorption and emission of nile red was investigated in a specially designed test cell. An ethanol admixture to Toliso led to a spectral shift towards higher wavelengths. The absorption and emission bands were shifted towards lower wavelengths with increasing temperature for all fuels. Both absorption and fluorescence decreased with increasing temperature for all fuels, except for E20, which showed an increased fluorescence signal with increasing temperature. Jet A-1 and its blends with hydroprocessed esters and fatty acids (HEFA) and farnesane did not exhibit explicit variations in spectral absorption or emission, but these blends showed a more distinct temperature dependence compared to the Toliso-ethanol-blends. The effect of photo-dissociation of the LIF signal of the fuel tracer mixtures was studied, and all fuel mixtures besides Toliso showed a more or less distinct decay in the fluorescence signal with time. In summary, all investigated fuel-tracer mixtures are suitable for LIF/Mie ratio droplet sizing in combination with nile red at moderate temperatures and low evaporation cooling rates.
- Open Access
Investigation of Soot Formation in a Novel Diesel Fuel Burner
In the present work, a novel burner capable of complete pre-vaporization and stationary combustion of diesel fuel in a laminar diffusion flame has been developed to investigate the effect of the chemical composition of diesel fuel on soot formation. For the characterization of soot formation during diesel combustion we performed a comprehensive morphological characterization of the soot and determined its concentration by coupling elastic light scattering (ELS) and laser-induced incandescence (LII) measurements. With ELS, radii of gyration of aggregates were measured within a point-wise measurement volume, LII was employed in an imaging approach for a 2D-analysis of the soot volume fraction. We carried out LII and ELS measurements at different positions in the flame for two different fuel types, revealing the effects of small modifications of the fuel composition on soot emission during diesel combustion.
Open AccessInvestigation of Soot Formation in a Novel Diesel Fuel Burner
In the present work, a novel burner capable of complete pre-vaporization and stationary combustion of diesel fuel in a laminar diffusion flame has been developed to investigate the effect of the chemical composition of diesel fuel on soot formation. For the characterization of soot formation during diesel combustion we performed a comprehensive morphological characterization of the soot and determined its concentration by coupling elastic light scattering (ELS) and laser-induced incandescence (LII) measurements. With ELS, radii of gyration of aggregates were measured within a point-wise measurement volume, LII was employed in an imaging approach for a 2D-analysis of the soot volume fraction. We carried out LII and ELS measurements at different positions in the flame for two different fuel types, revealing the effects of small modifications of the fuel composition on soot emission during diesel combustion.
- Open Access
- 16 November 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (24) , 31750-31766
Analysis of LIF and Mie signals from single micrometric droplets for instantaneous droplet sizing in sprays
Planar droplet sizing (PDS) is a technique relying on the assumption that laser-induced fluorescence (LIF) and Mie scattering optical signals from spherical droplets depend on their volume and surface area, respectively. In this article, we verify the validity of this assumption by experimentally analyzing the light intensity of the LIF and Mie optical signals from micrometric droplets as a function of their diameter. The size of the droplets is controlled using a new flow-focusing monodisperse droplet generator capable of producing droplets of the desired size in the range of 21 µm to 60 µm. Ethanol droplets doped with eosin dye and excited at 532 nm are considered in this study, and the individual droplets were imaged simultaneously at microscopic and macroscopic scale. The effects of laser power, dye concentration, and temperature variation are systematically studied as a function of LIF/Mie ratio in the whole range of droplet sizes. Finally, a calibration curve at tracer concentration of 0.5 vol% is deduced and used to extract the droplet Sauter mean diameter (SMD) from instantaneous images of a transient ethanol spray. This droplet size mapping is done using structured laser illumination planar imaging (SLIPI), in order to suppress the artifacts induced by multiple light scattering.
- 16 November 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (24) , 31750-31766
Open AccessAnalysis of LIF and Mie signals from single micrometric droplets for instantaneous droplet sizing in sprays
Planar droplet sizing (PDS) is a technique relying on the assumption that laser-induced fluorescence (LIF) and Mie scattering optical signals from spherical droplets depend on their volume and surface area, respectively. In this article, we verify the validity of this assumption by experimentally analyzing the light intensity of the LIF and Mie optical signals from micrometric droplets as a function of their diameter. The size of the droplets is controlled using a new flow-focusing monodisperse droplet generator capable of producing droplets of the desired size in the range of 21 µm to 60 µm. Ethanol droplets doped with eosin dye and excited at 532 nm are considered in this study, and the individual droplets were imaged simultaneously at microscopic and macroscopic scale. The effects of laser power, dye concentration, and temperature variation are systematically studied as a function of LIF/Mie ratio in the whole range of droplet sizes. Finally, a calibration curve at tracer concentration of 0.5 vol% is deduced and used to extract the droplet Sauter mean diameter (SMD) from instantaneous images of a transient ethanol spray. This droplet size mapping is done using structured laser illumination planar imaging (SLIPI), in order to suppress the artifacts induced by multiple light scattering.