KDKaria R. Dibert

Karia R. Dibert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karia R. Dibert has a total of 207 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SPT-3G D1: a measurement of secondary cosmic microwave background anisotropy power

    by P. Chaubal, N. Huang, C.L. Reichardt, A.J. Anderson, B. Ansarinejad, M. Archipley, L. Balkenhol, D.R. Barron, K. Benabed, A.N. Bender, et al.

    We report new measurements of millimeter-wave temperature power spectra in the angular multipole range 1700 ≤ ℓ ≤ 11,000 (wavelengths 13 ' ≳ λ ≳ 2 ' ). We use two years of data in three observing bands centered near 95, 150, and 220 GHz from the SPT-3G receiver on the South Pole Telescope that cover a 1646 deg 2 region of the Southern sky. Using the measured power spectra, we present constraints on the thermal and kinematic Sunyaev-Zel'dovich (SZ) effects, radio galaxies, and cosmic infrared background (CIB). We find that inferred SZ powers are dependent on the detailed modeling of the thermal SZ-CIB correlation, and to a lesser extent on the assumed angular dependence of the SZ spectra. We report constraints for simulation-based model templates as well as fits where the angular dependencies of the SZ and CIB power spectra are allowed to vary. In the latter case at ℓ = 3000, we find thermal SZ power at 143 GHz of D 3000 tSZ = 4.98 ± 0.35 μ K 2 and kinematic SZ power of D 3000 kSZ = 1.98 ± 0.87 μ K 2 . We use the measured kinematic SZ power to estimate the duration of reionization, noting that the reionization inferences are sensitive to the model choices and assumed level of homogeneous kinematic SZ power from the late-time universe. We find a 95% limit on the duration from an ionization fraction of 25% to 75% of Δ 50 z re < 4.2 based on a semi-analytic model, or a limit on the duration from an ionization fraction of 5% to 95% of Δ 90 z re < 7.0 based on the AMBER simulations.

  • An On-Sky Atmospheric Calibration of SPT-SLIM

    by Karia Dibert, Michel Adamic, Adam Anderson, Peter Barry, Bradford Benson, Chris Benson, Elyssa Brooks, John Carlstrom, Tom Cecil, Clarence Chang, et al.


  • Spectral characterization and performance of SPT-SLIM on-chip filterbank spectrometers

    by C. S. Benson, K. Fichman, M. Adamic, A. J. Anderson, P. S. Barry, B. A. Benson, E. Brooks, J. E. Carlstrom, T. Cecil, C. L. Chang, et al.

    The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) experiment is a pathfinder for demonstrating the use of on-chip spectrometers for millimeter (mm) Line Intensity Mapping (LIM). We present spectral bandpass measurements of the SPT-SLIM spectrometer channels made on site using a Fourier Transform Spectrometer during the first deployment of SPT-SLIM in the 2024-2025 Austral summer season. We note the effect of FTS systematics on measurements of on-chip filterbank spectrometer resolutions and demonstrate a technique for measuring the narrow band passes of the SPT-SLIM filterbanks that improves beyond the intrinsic resolution of a Fourier Transform Spectrometer.


  • Design and Performance of the SPT-SLIM Receiver Cryostat

    by M. R. Young, M. Adamic, A. J. Anderson, P. S. Barry, B. A. Benson, C. S. Benson, E. Brooks, J. E. Carlstrom, T. Cecil, C. L. Chang, et al.

    The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic duty cycle above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.


  • Open Access

    Automated analysis of the visual properties of superconducting detectors

    by K.R. Ferguson, A.N. Bender, N. Whitehorn, P.S. Barry, T.W. Cecil, K.R. Dibert, E.S. Martsen

    The testing and quality assurance of cryogenic superconducting detectors is a time- and labor-intensive process. As experiments deploy increasingly larger arrays of detectors, new methods are needed for performing this testing quickly. Here, we propose a process for flagging under-performing detector wafers before they are ever tested cryogenically. Detectors are imaged under an optical microscope, and computer vision techniques are used to analyze the images, searching for visual defects and other predictors of poor performance. Pipeline performance is verified via a suite of images with simulated defects, yielding a detection accuracy of 98.6%. Lastly, results from running the pipeline on prototype microwave kinetic inductance detectors from the planned SPT-3G+ experiment are presented.

  • Development of an MKID Frequency-to-Pixel LED Mapper for SPT-3G+

    by E. S. Martsen, P. S. Barry, B. A. Benson, K. R. Dibert, K. N. Fichman, T. Natoli, M. Rouble, C. Yu

    SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34 000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.


  • Low-Loss Si-Based Dielectrics for High Frequency Components of Superconducting Detectors

    by M. Lisovenko, Z. Pan, P. S. Barry, T. Cecil, C. L. Chang, K. R. Dibert, R. Gualtieri, J. Li, V. Novosad, G. Wang, et al.

    Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.


  • Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

    by T. Cecil, C. Albert, A. J. Anderson, P. S. Barry, B. Benson, C. Cotter, C. Chang, M. Dobbs, K. Dibert, R. Gualtieri, et al.

    Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an $R$ = $\lambda / \Delta \lambda = 300$ on-chip superconducting filter-bank spectrometer covering the 120–180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.


  • Open Access

    Characterization of MKIDs for CMB observation at 220 GHz with the South Pole Telescope

    by Karia R. Dibert, Peter S. Barry, Adam J. Anderson, Bradford A. Benson, Thomas Cecil, Clarence L. Chang, Kyra N. Fichman, Kirit Karkare, Juliang Li, Tyler Natoli, et al.

    We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_i = 4.8 \times 10^5$, aluminum inductor transition temperature $T_c = 1.19$ K, and kinetic inductance fraction $α_k = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $η\sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5\% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$ for both detector orientations.

  • Open Access

    Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

    by J. Li, P. S. Barry, T. Cecil, C. L. Chang, K. Dibert, R. Gualtieri, M. Lisovenko, Z. Pan, V. Yefremenko, G. Wang, et al.

    We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 μm^{3} by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time τqp approaches a constant value at low temperature.