Hong-Zeng Yu
Research Subjects
Hong-Zeng Yu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Ditch
FM Global, Research Division, Norwood, USA
1 shared publication John L. De Ris
FM Global, 1151 Boston-Providence Turnpike, NorwoodMA 02062, USA
1 shared publicationMatthew Daelhousen
FM Global
1 shared publicationRobert Kasiski
FM Global
1 shared publicationXin Liu
TianJin fire research institute
1 shared publication
Latest Publications
- 7 August 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (6) , 3355-3374
Water Mist Extinguishment of Mechanically-Ventilated Vertical Duct Fires
- 7 August 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (6) , 3355-3374
Water Mist Extinguishment of Mechanically-Ventilated Vertical Duct Fires
- 1 December 2021
- Published by Springer Nature in Fire Technology
- Vol. 58 (3) , 1333-1362
Water Mist Extinguishment of Horizontal Exhaust Duct Fires
- 1 December 2021
- Published by Springer Nature in Fire Technology
- Vol. 58 (3) , 1333-1362
Water Mist Extinguishment of Horizontal Exhaust Duct Fires
- 19 May 2020
- Published by Springer Nature in Fire Technology
- Vol. 57 (1) , 163-187
The Ceiling Height Limits for Water Mist Protection of Two Solid Combustible Fire Hazards in Open Environment
- 19 May 2020
- Published by Springer Nature in Fire Technology
- Vol. 57 (1) , 163-187
The Ceiling Height Limits for Water Mist Protection of Two Solid Combustible Fire Hazards in Open Environment
- 14 November 2018
- Published by Springer Nature in Fire Technology
- Vol. 55 (1) , 343-361
An Efficacy Evaluation of Water Mist Protection Against Solid Combustible Fires in Open Environment
- 14 November 2018
- Published by Springer Nature in Fire Technology
- Vol. 55 (1) , 343-361
An Efficacy Evaluation of Water Mist Protection Against Solid Combustible Fires in Open Environment
- 12 January 2016
- Published by Springer Nature in Fire Technology
- Vol. 52 (6) , 2143-2157
Investigation of Fire Extinguishment in Large Facilities based on Physical Scaling, Modeling and Testing
- 12 January 2016
- Published by Springer Nature in Fire Technology
- Vol. 52 (6) , 2143-2157
Investigation of Fire Extinguishment in Large Facilities based on Physical Scaling, Modeling and Testing
- 19 August 2014
- Published by Springer Nature in Fire Technology
- Vol. 51 (4) , 923-950
Characterization of Twin-Fluid (Water Mist and Inert Gas) Fire Extinguishing Systems by Testing and Modeling
- 19 August 2014
- Published by Springer Nature in Fire Technology
- Vol. 51 (4) , 923-950
Characterization of Twin-Fluid (Water Mist and Inert Gas) Fire Extinguishing Systems by Testing and Modeling
- 21 June 2013
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 23 (3) , 157-176
Physical scaling of water mist protection for ignitable liquid cut-off rooms
Based on the Froude-modeling scaling approach, water mist protection for a 7.47 × 7.47 × 7.47-m cut-off room where ignitable liquids are used was projected from the previously determined extinguishing requirement for heptane pool fires in a ½-scale enclosure and then verified with full-scale testing. The full-scale building occupancy was required to accommodate cut-off room door openings ranging from 1.86 × 3.73 m high up to 3.73 × 3.73 m. The fire challenge was a heptane spill fire cascading from the top of a 1.83-m dia. by 2.74-m high steel tank at a spill rate of 37.9 L/min. Two off-the-shelf nozzles were selected as candidates for the full-scale building to approximate the scaled-up water mist spray requirement. At a discharge pressure of 90 bar, one nozzle discharged 28 L/min, with a spray angle of 100° and a volume-median droplet dia. of 115 µm; the other discharged 24.4 L/min, with a 180° spray angle and median dia. of 96 µm. Nine nozzles were arranged at the ceiling level in a 3 × 3 matrix with a spacing of 1.86 × 1.86 m. Before the two candidate protection schemes were challenged with the spill fire, scaled-up heptane pool fires were used to ensure that the fire extinguishing propensity was consistent with that observed in the ½-scale enclosure. The pool fire tests showed that the nozzle with the smaller spray angle provided better fire extinguishing performance, which was later confirmed in the spill fire tests. The protection scheme with the smaller spray angle could extinguish the spill fire for door openings up to 3.05 × 3.05 m. For larger openings, two additional downward water mist sprays were required in the door opening to expedite fire extinguishment by reducing ventilation through the door opening. Water mist protection could provide adequate cooling to fuel tanks as long as such protection could extinguish the fire. Overall, the investigation demonstrated that physical scaling is a useful tool to provide an engineering estimate of water mist protection requirements.
- 21 June 2013
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 23 (3) , 157-176
Physical scaling of water mist protection for ignitable liquid cut-off rooms
Based on the Froude-modeling scaling approach, water mist protection for a 7.47 × 7.47 × 7.47-m cut-off room where ignitable liquids are used was projected from the previously determined extinguishing requirement for heptane pool fires in a ½-scale enclosure and then verified with full-scale testing. The full-scale building occupancy was required to accommodate cut-off room door openings ranging from 1.86 × 3.73 m high up to 3.73 × 3.73 m. The fire challenge was a heptane spill fire cascading from the top of a 1.83-m dia. by 2.74-m high steel tank at a spill rate of 37.9 L/min. Two off-the-shelf nozzles were selected as candidates for the full-scale building to approximate the scaled-up water mist spray requirement. At a discharge pressure of 90 bar, one nozzle discharged 28 L/min, with a spray angle of 100° and a volume-median droplet dia. of 115 µm; the other discharged 24.4 L/min, with a 180° spray angle and median dia. of 96 µm. Nine nozzles were arranged at the ceiling level in a 3 × 3 matrix with a spacing of 1.86 × 1.86 m. Before the two candidate protection schemes were challenged with the spill fire, scaled-up heptane pool fires were used to ensure that the fire extinguishing propensity was consistent with that observed in the ½-scale enclosure. The pool fire tests showed that the nozzle with the smaller spray angle provided better fire extinguishing performance, which was later confirmed in the spill fire tests. The protection scheme with the smaller spray angle could extinguish the spill fire for door openings up to 3.05 × 3.05 m. For larger openings, two additional downward water mist sprays were required in the door opening to expedite fire extinguishment by reducing ventilation through the door opening. Water mist protection could provide adequate cooling to fuel tanks as long as such protection could extinguish the fire. Overall, the investigation demonstrated that physical scaling is a useful tool to provide an engineering estimate of water mist protection requirements.
- 1 November 2009
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 19 (4) , 275-289
The Skip-resistant Sprinkler Concept -- Theoretical Evaluation
This article presents a model for the response time of a sprinkler designed to reduce the skipping phenomenon experienced during large-scale fires. The model guides the design of a cylindrical shield intended to reduce drop impingement from nearby operating sprinklers. Several designs are experimentally tested and shown to reduce likely skipping when compared to the same sprinkler without a shield. The model is validated using a laboratory Plunge Tunnel apparatus to measure the effect of the shield on the thermal sensitivity of the sprinkler and its ability to intercept water drops. This work successfully demonstrates that shielding can decrease the response time of a sprinkler in drop-laden gas flow without causing a substantial increase in response time when exposed to a dry-gas flow. This is the first of two articles on the skip-resistant sprinkler concept. The following article evaluates the performance of the shield in actual fires.
- 1 November 2009
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 19 (4) , 275-289
The Skip-resistant Sprinkler Concept -- Theoretical Evaluation
This article presents a model for the response time of a sprinkler designed to reduce the skipping phenomenon experienced during large-scale fires. The model guides the design of a cylindrical shield intended to reduce drop impingement from nearby operating sprinklers. Several designs are experimentally tested and shown to reduce likely skipping when compared to the same sprinkler without a shield. The model is validated using a laboratory Plunge Tunnel apparatus to measure the effect of the shield on the thermal sensitivity of the sprinkler and its ability to intercept water drops. This work successfully demonstrates that shielding can decrease the response time of a sprinkler in drop-laden gas flow without causing a substantial increase in response time when exposed to a dry-gas flow. This is the first of two articles on the skip-resistant sprinkler concept. The following article evaluates the performance of the shield in actual fires.