DZDezhong Zhao

Dezhong Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dezhong Zhao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Kang Cui

    Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi’an, P.R. China

    3 shared publications
  • Qichao Jin

    Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi’an, P.R. China

    3 shared publications
  • Wenhu Wang

    Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi’an, P.R. China

    3 shared publications
  • Jinhua Zhou

    Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi’an, P.R. China

    2 shared publications
  • Kunyang Lin

    The Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi’an 710072, China

    1 shared publication
  • Rui-Song Jiang

    1 shared publication

Latest Publications

  • Open Access

    Measurement point sampling method for inspection of parts with free-form surfaces

    by Dezhong Zhao, Wenhu Wang, Jinhua Zhou, Ruisong Jiang, Kang Cui, Qichao Jin

    Parts must be measured to evaluate the manufacturing accuracy in order to check whether their dimension is in expected tolerance. In engineering, parts with free-form surfaces are generally measured by high-precision coordinate-measuring machines. The measurement accuracy is usually improved by increasing the density of measurement points, which is time-consuming and costly. In this article, a novel sampling method of measurement points for free-form surface inspection is proposed. First, surface inspection is simplified into the inspection of a number of section curves of the surface. Second, B-spline curves constructed with an iterative method are employed to approximate these section curves. Subsequently, data points necessary to construct the B-spline curves are taken as the measurement points. Finally, the proposed method is compared with other two sampling methods. The results indicate that the proposed method greatly reduced the number of measurement points without decreasing the precision of surface modeling.


  • Open Access

    Dimensional Deviation Estimation for Parts with Free-Form Surfaces

    by Dezhong Zhao, Wenhu Wang, Jinhua Zhou, Kang Cui, Qichao Jin

    Dimensional deviation is a prerequisite for improving the manufacturing process of parts with free-form surfaces, for example, the reverse adjustment of the die cavity of turbine blade. Influenced by random noise of the manufacturing process, dimensional variation is inevitable for batch parts. Therefore, it may cause unacceptable error to estimate batch parts dimensional deviation by a single sample. Meanwhile, the optimum sample size for estimating dimensional deviation is difficult to determine. To overcome this problem, a practical method for estimating of dimensional deviation of parts with free-form surface is proposed. Firstly, displacements of the discrete points on part surface are employed to represent dimensional error of the part. Estimating dimensional deviation of parts is actually to estimate the simultaneous confidence intervals of the discrete point displacements. Secondly, Bonferroni simultaneous confidence intervals are adopted to estimate the confidence intervals of the part dimensional deviation. Moreover, the accuracy of the estimation will be continuously improved by increasing samples. Consequently, a practical dimensional deviation estimation method is presented. Finally, a compressor blade is adopted to illustrate the proposed method. The percentage of estimation error of the blade dimensional deviation that is less than 0.05mm, which is the estimation error limit, of all the 100 times sampling experiments is 99%, exceeding the given confidence level of 95%, while the percentage of the existing method is below the confidence level, only 87%.


  • Open Access

    Evaluation of Residual Stress Distribution and Relaxation on In Situ TiB2/7050 Al Composites

    by Kunyang Lin, Wenhu Wang, Ruisong Jiang, Yifeng Xiong, Dezhong Zhao

    Interior residual stresses induced by quenching may cause distortion during subsequent machining processes. Hence, various strategies have been employed to relieve the interior residual stress, such as stretching, post treatment, and other techniques. In this study, the stress distribution inside TiB2/7050 Al composite extrusions was investigated and the effects of different methods on relieving the quenching-induced stress were compared. Firstly, three TiB2/7050 Al composite extrusions were treated by stretching, stretching and heat treatment, and stretching and cold treatment processes, respectively. Then, the multiple-cut contour method was employed to assess the residual stresses in the three workpieces. Experimental results indicate that the interior stress of TiB2/7050 Al composite extrusions after stretching ranges from −89 MPa to +55 MPa, which is larger than that in 7050 aluminum alloy, which ranges from −25 Pa to +25 MPa. The heat treatment performs better than the cold treatment to reduce the post-stretching residual stress, with a reduction of 23.2–46.4% compared to 11.3–40.8%, respectively. From the stress map, it is found that the stress distribution after the heat treatment is more uniform compared with that after the cold treatment.


  • Effect of Injection Processing Parameters on Residual Stress for Compressor Experimental Blade Using FEM and RSM

    by Dezhong Zhao, Wenhu Wang, Ruisong Jiang, Kang Cui, Qichao Jin

    Injection molding-induced residual stresses have strong influence on molding precision for compressor experimental blade used on LSRC (Low Speed Research Compressor). In this paper, finite element model (FEM) and response surface methodology (RSM) are employed to reveal the effect of processing parameters on residual stress for injection molding of compressor experimental blade. First, the influence of processing parameters such as melt temperature, mold temperature on the residual stress of blade was studied based on factorial experiment. Then, the rules of influence of the main processing parameters and their interactions on injection residual stress of blade was analyed based on RSM . The results show that the packing time and melt temperature are the principle factors for controlling injection residual stress of compressor experimental blade . In addition, the packing time and melt temperature has strong interaction effect on the residual stress of blade.