Gabriel Alves Mendonca has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Experimental Evaluation of an In-Wheel Flux-Switching Machine for Light Vehicle Application

    by Gabriel A. Mendonça, Diogo P. V. Galo, Luís Carlos M. Sales, Braz J. Cardoso Filho, Thales A. C. Maia

    Restrictive regulations regarding emissions and fossil fuel consumption lead to the electric vehicle being an alternative to replace conventional internal combustion engine vehicles. The pure electric powertrain technology and the charging infrastructure are still immature in some markets, where increasing the overall vehicle efficiency by energy harvesting means can be a more viable solution. This paper presents the design and experimental validation of an in-wheel flux-switching machine for regenerative braking in a light passenger vehicle. Later, the energy can be used for fuel handling and reforming, performance enhancement, increasing efficiency, and reducing emissions. Feasibility and technological challenges are also discussed. The Maxwell–Fourier method and a novel steady-state equivalent circuit presented in this paper are used for geometry sensitivity analysis and optimization routine.


  • Open Access

    Magnetic Field Analytical Solution for Non-homogeneous Permeability in Retaining Sleeve of a High-Speed Permanent-Magnet Machine

    by Gabriel A. Mendonça, Thales A. C. Maia, Braz J. Cardoso Filho

    This work presents a novel solution for magnetic field calculation in two-dimensional problems in which one region is defined with space-varying magnetic parameter. The proposed solution extends the well-established Maxwell–Fourier method for calculating magnetic fields in surface-mounted cylindrical high-speed permanent-magnet machines. This contribution is effective to evaluate more realistic magnetic parameters, where measurements of a high-speed permanent-magnet generator prototype indicate saturation in the retaining sleeve due to pole-to-pole leakage flux. The saturation profile is a function of mechanical angle and can be modeled with the aid of a space-varying relative permeability, expressed in terms of a Fourier series. As an example, the presented solution has been applied to a surface-mounted PM machine at no-load condition. Magnetic field calculations show that a simple saturation profile, with low order space-varying permeability in the retaining sleeve significantly affects the magnetic flux density distribution in the air-gap. The analytical solution is confronted with finite-element method, which confirms validity of the proposed methodology.


  • Mission Critical Analysis and Design of IGBT-Based Power Converters Applied to Mine Hoist Systems

    by Victor de Nazareth Ferreira, Gabriel Alves Mendonca, Anderson Vagner Rocha, Robson Silva Resende, Braz de Jesus Cardoso Filho

    Mine hoist systems play a vital role in gold ore transportation. They are the connection between the underground mine and the beneficiation plant. As a result, any hoist system interruption compromises the production. In this paper, it is proposed a mission critical analysis and design methodology for power converters in order to achieve proper reliability of the hoist drive system. Since the failure of power devices is responsible for a significant portion of the total downtime of power converters, a detailed study of the insulated gate bipolar transistor (IGBT) power modules lifetime is carried out. The three level neutral-point-clamped and Active Neutral Point Clamped (ANPC) IGBT-based topologies are considered for this application. The recently presented Fault-Tolerant (FT)-ANPC converter is proposed as a higher reliability solution leading to longer power modules and drive system lifetimes. All the studies are based on practical operating data from a 900-m deep shaft hoist system operating in a gold mine in southeastern Brazil.


  • Medium voltage IGBT-based converters in mine hoist systems

    by Victor N. Ferreira, Gabriel A. Mendonca, Anderson V. Rocha, Robson S. Resende, Braz J. Cardoso Filho

    In underground mining industry, mineral transportation from lower levels to the surface is critical, thus demanding thorough equipment selection. The dc motor driven hoist dominated these applications, providing superior controllability. However, due to its increasing popularity, ac drive systems replaced dc application, including in mine hoisting. The high power ratings typical of these systems imply the use of medium voltage adjustable speed drive (MV-ASD), offering high power density, excellent efficiency and high reliability. This paper discusses two commonly used medium voltage topologies, namely the Three-Level Neutral-Point-Clamped and Active Neutral- Point-Clamped Voltage-Source Converter (3L-NPC and 3LANPC VSC). These topologies are compared to a recently proposed Fault-Tolerant realization of 3L-ANPC (FT-ANPC VSC). The hoist load cycle, which is severe in terms of thermal cycling profile, is used to evaluate the lifetime in power modules for all three topologies.