HBHyunkyung Ban

Hyunkyung Ban

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hyunkyung Ban has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characteristics of Indoor PM2.5 Concentration in Gers Using Coal Stoves in Ulaanbaatar, Mongolia

    by Miyoung Lim, Sainnyambuu Myagmarchuluun, Hyunkyung Ban, Yunhyung Hwang, Chimedsuren Ochir, Delgerzul Lodoisamba, Kiyoung Lee

    Coal combustion in ger areas is the main source of ambient air pollution in Ulaanbaatar (Mongolia). This study determined the characteristics of indoor PM2.5 concentrations in gers using coal stoves during winter. The study population consisted of 60 gers in the Chingeltei district of Ulaanbaatar. The indoor particle number concentration (PNC) in each ger was measured using a Dylos DC1700 particle counter for 24 h in January and February 2016. The PNC by Dylos was converted into the mass concentration using a calibration equation developed using a collocated real-time light scattering monitor adjusted by gravimetric measurement. The average 24 h PM2.5 concentration was 203.9 ± 195.1 μg/m3 in gers with traditional stoves (n = 29) and 257.5 ± 204.4 μg/m3 in those with improved stoves (n = 31). In the daily profile, concentrations were lower at night, increased in the early morning, and peaked up to noon. The temperature in gers was slightly higher than that recommended in winter. Many development-assistance programs have supported the installation of improved energy-efficient stoves. Better control measures are needed to improve the indoor air quality of gers.


  • Temporal Variation of Indoor Air Quality in Daycare Centers

    by Yoonjee Kim, Sewon Lee, Hyunkyung Ban, Sangmin Cha, Geunbae Kim, Kiyoung Lee

    Temporal Variation of Indoor Air Quality in Daycare Centers Indoor;time variation;real-time data;daycare;particulate matter;carbon dioxide; Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.


  • Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors

    by Boram Lee, Daeyeop Lee, Hyunkyung Ban, Sewon Lee, KyooSang Kim, Kiyoung Lee

    Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors Overall comfort;thermal comfort;noise;illumination;carbon dioxide; Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.