IAIbrahim Ahmad

Ibrahim Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ibrahim Ahmad has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Ghaeth Fandi

    Department of Electrical Power Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, Prague 6, 166 27 Prague, Czech Republic

    4 shared publications
  • Josef Tlusty

    Department of Electrical Power Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 166 27 Prague 6, Czech Republic

    4 shared publications
  • Zdenek Muller

    Department of Electrical Power Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 166 27 Prague 6, Czech Republic

    4 shared publications
  • Famous Oghomwen Igbinovia

    Department of Electrical Power Engineering, Faculty of Electrical Engineering , Czech Technical University in Prague , Czech Republic

    3 shared publications
  • Vladimír Krepl

    Department of Economics, Faculty of Economics and Management, Czech University of Life Sciences Prague, Kamýcká 129, Suchdol, 165 00 Prague, Czech Republic

    2 shared publications
  • Soliman Fandie

    Chercheur Associé au Laboratoire ICAR, UMR 5191, CNRS, Université Lumière Lyon 2, ENS de Lyon, 15, Parvis René Descartes BP 7000, CEDEX 07, 69342 Lyon, France

    1 shared publication

Latest Publications

  • Open Access

    Voltage Quality and Power Factor Improvement in Smart Grids Using Controlled DG Units

    by Ibrahim Ahmad, Ghaeth Fandi, Zdenek Muller, Josef Tlusty

    The increased penetration of renewable energy sources in the electrical grid, due to the rapid increase of power demand and the need of diverse energy sources, has made distributed generation (DG) units an essential part of the modern electrical grid. The integration of many DG units in smart grids requires control and coordination between them, and the grid to maximize the benefits of the DG units. Smart grids and modern electronic devices require high standards of power quality, especially voltage quality. In this paper, a new methodology is presented to improve the voltage quality and power factor in smart grids. This method depends on using voltage variation and admittance values as inputs of a controller that controls the reactive power generation in all DG units. The results show that the controller is efficient in improving the voltage quality and power factor. Real data from an electrical network have been used in the simulation model in MATLAB Simulink to test the new approach.


  • Open Access

    Modeling and Simulation of the Anticipated Effects of the Synchronous Condenser on an Electric-Power Network with Participating Wind Plants

    by Famous O. Igbinovia, Ghaeth Fandi, Ibrahim Ahmad, Zdenek Muller, Josef Tlusty

    Installing a synchronous condenser (SC) onto an electricity grid can assist in the areas of reactive power needs, short-circuit strength, and, consequently, system inertia and guarantees better dynamic voltage recovery. This paper summarizes the practical potential of the synchronous condenser coordinated in an electric-power network with participating wind plants to supply reactive power compensation and injection of active power at their point of common coupling; it provides a systematic assessment method for simulating and analyzing the anticipated effects of the synchronous condenser on a power network with participating wind plants. A 33-kV power line has been used as a case study. The results indicate that the effect of the adopted synchronous condenser solution model in the MATLAB/Simulink environment provides reactive power, enhances voltage stability, and minimizes power losses, while the wind power plants provide active power support with given practical grid rules.


  • Open Access

    Design of an Emergency Energy System for a City Assisted by Renewable Energy, Case Study: Latakia, Syria

    by Ghaeth Fandi, Vladimír Krepl, Ibrahim Ahmad, Famous O. Igbinovia, Tatiana Ivanova, Soliman Fandie, Zdenek Muller, Josef Tlusty

    Electrical energy is one of the most important daily needs. Shortage of energy can be very dangerous for any society. This can affect the standard of living and quality of life of the people and even endanger the lives of those in hospitals, and so forth. Developed countries do not face such risks in general because they have well organized electrical systems and high energy security. The developing countries are faced daily with electric system collapses, especially in the case of wars, where many parts of the electrical grid in the country can be damaged and fuel transmission lines for generators cut off. Urban areas in developing countries should have a strategic plan to deal with any unexpected occurrence of energy shortages using any available renewable energy sources. City of Latakia is located in the region which has been suffering from the consequences of war for more than six years. The fact that a high number of migrants from other cities have come to Latakia along with a lack of fuel makes the energy shortage in the city worse. An emergency system could use the cheapest available renewable energy sources in addition to few big portable generators to provide an acceptable energy supply for the most needed requirements of daily life.


  • Open Access

    Voltage Regulation and Power Loss Minimization in Radial Distribution Systems via Reactive Power Injection and Distributed Generation Unit Placement

    by Ghaeth Fandi, Ibrahim Ahmad, Famous O. Igbinovia, Zdenek Muller, Josef Tlusty, Vladimir Krepl

    Distributed Generation (DG) has become an essential part of the smart grids due to the widespread integration of renewable energy sources. Reactive power compensation is still one of most important research topics in smart grids. DG units can be used for reactive power compensation purposes, therefore we can improve the voltage profile and minimize power losses in order to improve the power quality. In this paper two methods will be used to accomplish the mentioned tasks; the first technique depends on the reactive power demand change of the proposed network loads, whereas the second technique uses an algorithm to control DG units according to the measured voltage values in the feeders to generate the needed reactive power. Both methods were applied to different scenarios of DG unit positions and different reactive power values of loads. The chosen DG unit is made up of a Type-4 wind farm which could be used as a general unit where it is able to control reactive power generation in a wider range separately from active power. The simulation results show that using these two methods, the voltage profile could be improved, power losses reduced and the power factor increased according to the placement of DG units.