Wensheng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wensheng Lu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Baofeng Huang
College of Civil Engineering Shanghai Normal University Shanghai China
4 shared publications - Kaoshan Dai
Sichuan University
2 shared publications - Liyu Xie
Department of Disaster Mitigation for Structures, Tongji University, Shanghai, China
2 shared publications Selim Günay
Department of Civil and Environmental Engineering University of California, Berkeley Berkeley California USA
2 shared publications- Baijie Zhu
Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, P. R. China
1 shared publication - Bo Fu
School of Civil Engineering, Chang’an University, Xi’an, China
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by China Science Publishing & Media Ltd. in Journal of Engineering Studies
- Vol. 17 (5) , 576-589
Life-friendliness in Engineering and Life-education for Engineers
工程作为人类文明演进的物化载体,与自然界中的各类生命形态存在密切联系。如何更好地建立起生命友好的特性,为人类提供安全、绿色、人性化、可持续的功能服务,同时尽量避免和减少对动植物等的伤害和不利影响,是工程理论、技术和文化发展的重要课题。为此,需要逐步建立完善工程生命友好的理论和实践体系,将生命友好的理念全方位融入工程建设的各个方面和工程全生命周期的各个阶段,助力维护人与自然和谐共生。工程师是工程生命友好特性的设计者和实现者,应该对生命具有深切的认识、敏锐的感知力和温暖的爱心,这也是工程师卓越品质的关键要素。本文提出工程师生命教育的体系架构,以推动工程师面向生命友好需求的专业技术能力与人文素养的提升。
- 1 October 2025
- Published by China Science Publishing & Media Ltd. in Journal of Engineering Studies
- Vol. 17 (5) , 576-589
Open AccessLife-friendliness in Engineering and Life-education for Engineers
工程作为人类文明演进的物化载体,与自然界中的各类生命形态存在密切联系。如何更好地建立起生命友好的特性,为人类提供安全、绿色、人性化、可持续的功能服务,同时尽量避免和减少对动植物等的伤害和不利影响,是工程理论、技术和文化发展的重要课题。为此,需要逐步建立完善工程生命友好的理论和实践体系,将生命友好的理念全方位融入工程建设的各个方面和工程全生命周期的各个阶段,助力维护人与自然和谐共生。工程师是工程生命友好特性的设计者和实现者,应该对生命具有深切的认识、敏锐的感知力和温暖的爱心,这也是工程师卓越品质的关键要素。本文提出工程师生命教育的体系架构,以推动工程师面向生命友好需求的专业技术能力与人文素养的提升。
- 21 June 2023
- Published by Elsevier in Structures
- Vol. 55, 718-726
Frequency calculation method and wind-induced dynamic response of cable net façades considering the façade stiffness
- 21 June 2023
- Published by Elsevier in Structures
- Vol. 55, 718-726
Frequency calculation method and wind-induced dynamic response of cable net façades considering the façade stiffness
- 14 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 16672-16682
Passive Accelerometer Using Unstressed Patch Antenna Interrogated by FMCW Radar
Conventional accelerometers rely on cables or batteries to transmit power and data, which has raised the possibility of failure and maintenance complications. However, antenna-based acceleration sensors can achieve wireless and passive sensing, while the cycling stress inside the vibration member will significantly influence the durability of the sensor in practical utilization. Based on the patch antenna with an overlapping sub-patch, this study proposes an unstressed passive wireless accelerometer with a frequency-modulated-continuous-wave dynamic access. The sensing antenna of the proposed accelerometer is not affected by inertial forces, which effectively improves its usability and endurance for structural monitoring. A COMSOL-based simulation is conducted to verify the workability of the accelerometer’s sensing node. The practical viability of the sensing node and wireless interrogation system is investigated via experiments. Furthermore, the shifts of the resonant frequency of the antenna sensor triggered by the change in total radiation length due to inertial forces are collected to obtain acceleration. Subsequently, the obtained results are compared to the theoretical value, with an average testing range error of 4.3%. Accordingly, this design provides a promising alternative for engineering requirements such as modal parameter identification owning to its simple construction, optimal accuracy, and durability.
- 14 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (15) , 16672-16682
Passive Accelerometer Using Unstressed Patch Antenna Interrogated by FMCW Radar
Conventional accelerometers rely on cables or batteries to transmit power and data, which has raised the possibility of failure and maintenance complications. However, antenna-based acceleration sensors can achieve wireless and passive sensing, while the cycling stress inside the vibration member will significantly influence the durability of the sensor in practical utilization. Based on the patch antenna with an overlapping sub-patch, this study proposes an unstressed passive wireless accelerometer with a frequency-modulated-continuous-wave dynamic access. The sensing antenna of the proposed accelerometer is not affected by inertial forces, which effectively improves its usability and endurance for structural monitoring. A COMSOL-based simulation is conducted to verify the workability of the accelerometer’s sensing node. The practical viability of the sensing node and wireless interrogation system is investigated via experiments. Furthermore, the shifts of the resonant frequency of the antenna sensor triggered by the change in total radiation length due to inertial forces are collected to obtain acceleration. Subsequently, the obtained results are compared to the theoretical value, with an average testing range error of 4.3%. Accordingly, this design provides a promising alternative for engineering requirements such as modal parameter identification owning to its simple construction, optimal accuracy, and durability.
- Open Access
Shaking Table Test of a Base-Isolated Frame Structure under Near-Fault Ground Motions
A five-story moment frame structural model with a base isolation system was tested on a shaking table. The isolation system comprised both linear natural rubber bearing (LNR) and nonlinear viscous dampers (NLVDs). Seven ground motions were employed: including three far-fault (FF) and four near-fault (NF) earthquake ground motions. The performance of the isolation system was evaluated by measuring the displacement and base shear of the isolation bearings. Furthermore, the axial force and displacement of the NLVDs were measured. The evolution of the fundamental dynamic frequency of the frame during the test was also determined. During strong earthquakes, NF ground motions caused larger story drifts and floor accelerations of the superstructure than FF ground motions. The displacement and base shear of the isolation base was very large when the isolated structure was subjected to Kobe_TAK000 and ChiChi_TCU102/278 pulse-like NF ground motions. Furthermore, the LNR s experienced tension and uplift when the PGA of input earthquake ground motions was larger than 0.80 g. Although the NLVDs performed very well in combination with the LNRs, the severe responses of the isolation bearings were caused by NF ground motion with a pulse period Tp neighboring the fundamental period of the isolated structure.
Open AccessShaking Table Test of a Base-Isolated Frame Structure under Near-Fault Ground Motions
A five-story moment frame structural model with a base isolation system was tested on a shaking table. The isolation system comprised both linear natural rubber bearing (LNR) and nonlinear viscous dampers (NLVDs). Seven ground motions were employed: including three far-fault (FF) and four near-fault (NF) earthquake ground motions. The performance of the isolation system was evaluated by measuring the displacement and base shear of the isolation bearings. Furthermore, the axial force and displacement of the NLVDs were measured. The evolution of the fundamental dynamic frequency of the frame during the test was also determined. During strong earthquakes, NF ground motions caused larger story drifts and floor accelerations of the superstructure than FF ground motions. The displacement and base shear of the isolation base was very large when the isolated structure was subjected to Kobe_TAK000 and ChiChi_TCU102/278 pulse-like NF ground motions. Furthermore, the LNR s experienced tension and uplift when the PGA of input earthquake ground motions was larger than 0.80 g. Although the NLVDs performed very well in combination with the LNRs, the severe responses of the isolation bearings were caused by NF ground motion with a pulse period Tp neighboring the fundamental period of the isolated structure.
- 29 May 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (11) , 3015-3040
Free‐rocking tests of a freestanding object with variation of center of gravity
Freestanding nonstructural objects are very common in various infrastructure systems, but their dynamic properties with variations in the center of gravity (CG) are not yet fully understood. To investigate the dynamic properties of a freestanding object as its CG is varied, a steel frame model was fabricated using movable steel plates. Two scenarios, with varying and fixed CG, were considered in the free rocking tests. The experimental rotation responses generally matched the analytical responses in the initial cycles, and the discrepancy increased as the height of the CG (hcg) increased. The magnitude of the quarter period exhibited a similar trend. When the CG was fixed, the resulting magnitude of the quarter period varied slightly with hcg, indicating that the CG is one of the primary parameters affecting the quarter period. When the CG was varied, the experimental energy reduction factor was generally larger than the analytical results computed using the methods suggested in the literature, and it was scattered around the fixed CG value. The magnitude of the damping ratio was also scattered as the quarter cycle number increased, and it slightly decreased as hcg increased. An equivalent rectangular rigid block model with an equivalent height (heq) was employed to compute the geometric and dynamic parameters of the steel frame. The accuracy of this measure was investigated in terms of the quarter period and energy reduction factor. This work is beneficial for understanding the rocking behavior of freestanding objects.
- 29 May 2021
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (11) , 3015-3040
Free‐rocking tests of a freestanding object with variation of center of gravity
Freestanding nonstructural objects are very common in various infrastructure systems, but their dynamic properties with variations in the center of gravity (CG) are not yet fully understood. To investigate the dynamic properties of a freestanding object as its CG is varied, a steel frame model was fabricated using movable steel plates. Two scenarios, with varying and fixed CG, were considered in the free rocking tests. The experimental rotation responses generally matched the analytical responses in the initial cycles, and the discrepancy increased as the height of the CG (hcg) increased. The magnitude of the quarter period exhibited a similar trend. When the CG was fixed, the resulting magnitude of the quarter period varied slightly with hcg, indicating that the CG is one of the primary parameters affecting the quarter period. When the CG was varied, the experimental energy reduction factor was generally larger than the analytical results computed using the methods suggested in the literature, and it was scattered around the fixed CG value. The magnitude of the damping ratio was also scattered as the quarter cycle number increased, and it slightly decreased as hcg increased. An equivalent rectangular rigid block model with an equivalent height (heq) was employed to compute the geometric and dynamic parameters of the steel frame. The accuracy of this measure was investigated in terms of the quarter period and energy reduction factor. This work is beneficial for understanding the rocking behavior of freestanding objects.
- 27 October 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 267, 120967
Experimental investigation of the uniaxial compressive behavior of thin building granite
- 27 October 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 267, 120967
Experimental investigation of the uniaxial compressive behavior of thin building granite
- Open Access
- 29 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (19) , 6863
Experimental Investigation of the Multi-Physical Properties of an Energy Efficient Translucent Concrete Panel for a Building Envelope
The multi-physical properties of the building envelope play a major role in the energy efficiency of buildings. Translucent concrete panels (TCPs) with various volumetric ratios of optical fibers (OFs) were cast. To understand the multi-physical properties of the TCP for the building envelope, compressive strength, thermal and light transmittance tests were carried out. The compressive strength test showed that TCP with light-weight mortar (LWM) has higher strength compared to that with normal-weight mortar (NWM), but it did not exhibit an apparent ductile behavior. The U-values of the plain panel were 4.25 and 5.45 W/(m2 K) for TCPs with the LWM and NWM, respectively. The existence of the OFs improved the thermal insulation property. The K-values of the LWM TCP were smaller than that of the common façade, which proved its excellent energy-efficient performance. The solar heat gain coefficients (G-values) of the two tested TCP types—LWM and NWM—were 0.198 and 0.242, respectively. The visible light transmission test showed that the light transmitted by the TCP was proportional to the density of the OFs in a matrix of concrete. The experimental light acceptance angle of the OF was close to the computational value (35 °C). Therefore, all the experimental results demonstrated that TCPs can improve the energy efficiency of buildings.
- 29 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (19) , 6863
Open AccessExperimental Investigation of the Multi-Physical Properties of an Energy Efficient Translucent Concrete Panel for a Building Envelope
The multi-physical properties of the building envelope play a major role in the energy efficiency of buildings. Translucent concrete panels (TCPs) with various volumetric ratios of optical fibers (OFs) were cast. To understand the multi-physical properties of the TCP for the building envelope, compressive strength, thermal and light transmittance tests were carried out. The compressive strength test showed that TCP with light-weight mortar (LWM) has higher strength compared to that with normal-weight mortar (NWM), but it did not exhibit an apparent ductile behavior. The U-values of the plain panel were 4.25 and 5.45 W/(m2 K) for TCPs with the LWM and NWM, respectively. The existence of the OFs improved the thermal insulation property. The K-values of the LWM TCP were smaller than that of the common façade, which proved its excellent energy-efficient performance. The solar heat gain coefficients (G-values) of the two tested TCP types—LWM and NWM—were 0.198 and 0.242, respectively. The visible light transmission test showed that the light transmitted by the TCP was proportional to the density of the OFs in a matrix of concrete. The experimental light acceptance angle of the OF was close to the computational value (35 °C). Therefore, all the experimental results demonstrated that TCPs can improve the energy efficiency of buildings.
- 24 September 2020
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (2) , 518-537
Mechanical model and seismic study of the roller guide–rail assembly in the counterweight system of elevators
Summary: The roller guide–rail assembly, consisting of the roller guide, rail, and rail brackets, are the guiding components of an elevator system and are important for the seismic analysis of the counterweight system. This paper focuses on the mechanical model of the roller guide–rail assembly. Observations of both the in‐plane and out‐of‐plane static tests of the roller guide–rail assembly show that the mechanical behaviors of the roller guide–rail assembly are performed based on the basic two‐spring model, which is a model of two springs in series respectively representing the roller guide and the rail–bracket assembly. In addition, the force–displacement relation of the model shows nonlinear elastic, and it is demonstrated that two parameters, namely, the pretightening force of helical spring and the retainer plate–rail clearance, significantly affect the mechanical model. A numerical parametric study is carried out and illustrated by an example of the counterweight system to evaluate the effects of the parameters on the seismic responses of the counterweight, including the maximum values of the rail stress and the displacement of the roller guide off rail. Results indicate that for the model without helical spring saturation, which is recommended to be used, the maximum values of the seismic responses are reduced at smaller retainer plate–rail clearance accompanied by slight change with different pretightening forces. The effects on the seismic responses have provided the insights on the selection of the proper values of the parameters, which can be used to instruct the elevator design.
- 24 September 2020
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 50 (2) , 518-537
Mechanical model and seismic study of the roller guide–rail assembly in the counterweight system of elevators
Summary: The roller guide–rail assembly, consisting of the roller guide, rail, and rail brackets, are the guiding components of an elevator system and are important for the seismic analysis of the counterweight system. This paper focuses on the mechanical model of the roller guide–rail assembly. Observations of both the in‐plane and out‐of‐plane static tests of the roller guide–rail assembly show that the mechanical behaviors of the roller guide–rail assembly are performed based on the basic two‐spring model, which is a model of two springs in series respectively representing the roller guide and the rail–bracket assembly. In addition, the force–displacement relation of the model shows nonlinear elastic, and it is demonstrated that two parameters, namely, the pretightening force of helical spring and the retainer plate–rail clearance, significantly affect the mechanical model. A numerical parametric study is carried out and illustrated by an example of the counterweight system to evaluate the effects of the parameters on the seismic responses of the counterweight, including the maximum values of the rail stress and the displacement of the roller guide off rail. Results indicate that for the model without helical spring saturation, which is recommended to be used, the maximum values of the seismic responses are reduced at smaller retainer plate–rail clearance accompanied by slight change with different pretightening forces. The effects on the seismic responses have provided the insights on the selection of the proper values of the parameters, which can be used to instruct the elevator design.
- 8 June 2020
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 29 (13)
Coordinative similitude method considering overturning effect for scale model testing of structures with rubber bearings
Summary: Generally, when a prototype is scaled down to a scale model, all parameters of the scale model should be designed to satisfy the similitude criteria. For a base‐isolated structure with rubber bearings, however, it is technically difficult to obtain small‐sized rubber bearings with the first shape factor satisfying the similitude criteria. This distortion affects the similitude ratio of the vertical stiffness of the bearings and, thus, influences the similitude ratio of the horizontal response of the structure because of the overturning effect. To solve this problem, a coordinative similitude method is proposed for scale model testing of structures with rubber bearings by adjusting configuration of the isolators to match the similitude ratio of the overturning stiffness of the isolation layer. A full‐scale and two 1/3 scaled bearings were designed and tested, and their similitude relations were evaluated. Test results of the model bearings were extrapolated to the OpenSEES model of a conventional model building and a coordinative building designed based on the conventional similitude method and the coordinative similitude method, respectively. A comparison between seismic responses of two model buildings against the prototype building indicates that the coordinative similitude method has significantly larger accuracy than the traditional similitude method.
- 8 June 2020
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 29 (13)
Coordinative similitude method considering overturning effect for scale model testing of structures with rubber bearings
Summary: Generally, when a prototype is scaled down to a scale model, all parameters of the scale model should be designed to satisfy the similitude criteria. For a base‐isolated structure with rubber bearings, however, it is technically difficult to obtain small‐sized rubber bearings with the first shape factor satisfying the similitude criteria. This distortion affects the similitude ratio of the vertical stiffness of the bearings and, thus, influences the similitude ratio of the horizontal response of the structure because of the overturning effect. To solve this problem, a coordinative similitude method is proposed for scale model testing of structures with rubber bearings by adjusting configuration of the isolators to match the similitude ratio of the overturning stiffness of the isolation layer. A full‐scale and two 1/3 scaled bearings were designed and tested, and their similitude relations were evaluated. Test results of the model bearings were extrapolated to the OpenSEES model of a conventional model building and a coordinative building designed based on the conventional similitude method and the coordinative similitude method, respectively. A comparison between seismic responses of two model buildings against the prototype building indicates that the coordinative similitude method has significantly larger accuracy than the traditional similitude method.
- 4 March 2020
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 29 (8)
Mechanism and optimum design of shared tuned mass damper for twin‐tower structures connected at the top by an isolated corridor
Summary: The concept of shared tuned mass damper (STMD) for twin towers linked by a sky corridor using flexible joints is proposed in this paper. The analytical expressions of the transform functions and random earthquake responses of the flexibly connected structures are derived using a three‐degrees‐of‐freedom model system. The seismic reduction mechanism of the STMD is revealed using comparative analysis between the structures with STMD and those connected using a viscoelastic damper. The effect of the nondimensional parameters such as the frequency ratio of the two primary structures, mass ratio, tuning frequency ratio of the corridor, and damping ratio of the passive control devices on the structural seismic response is investigated. Optimum parametric analysis is performed using the principle of minimizing the displacements of both towers, and the optimal parameter formulas are established. Numerical analysis is conducted to verify the control effectiveness of the connected multi‐degree‐of‐freedom system subjected to the El Centro earthquake ground motion. The results show that the earthquake responses of the towers can be effectively reduced if the parameters of the flexible connecting elements are appropriately selected for a certain corridor mass. Moreover, a remarkable seismic reduction effect can be achieved if the towers have similar dynamic properties.
- 4 March 2020
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 29 (8)
Mechanism and optimum design of shared tuned mass damper for twin‐tower structures connected at the top by an isolated corridor
Summary: The concept of shared tuned mass damper (STMD) for twin towers linked by a sky corridor using flexible joints is proposed in this paper. The analytical expressions of the transform functions and random earthquake responses of the flexibly connected structures are derived using a three‐degrees‐of‐freedom model system. The seismic reduction mechanism of the STMD is revealed using comparative analysis between the structures with STMD and those connected using a viscoelastic damper. The effect of the nondimensional parameters such as the frequency ratio of the two primary structures, mass ratio, tuning frequency ratio of the corridor, and damping ratio of the passive control devices on the structural seismic response is investigated. Optimum parametric analysis is performed using the principle of minimizing the displacements of both towers, and the optimal parameter formulas are established. Numerical analysis is conducted to verify the control effectiveness of the connected multi‐degree‐of‐freedom system subjected to the El Centro earthquake ground motion. The results show that the earthquake responses of the towers can be effectively reduced if the parameters of the flexible connecting elements are appropriately selected for a certain corridor mass. Moreover, a remarkable seismic reduction effect can be achieved if the towers have similar dynamic properties.