Krzysztof Maksymiuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Krzysztof Maksymiuk has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Agata Michalska
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
65 shared publications - Justyna Kalisz
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
15 shared publications Agata Michalska
Faculty of Chemistry, University of Warsaw, Warsaw, Poland
13 shared publicationsAnna Kisiel
Faculty of Chemistry, University of Warsaw, Warsaw, Poland
13 shared publicationsEmilia Stelmach
9 shared publicationsEwa Jaworska
Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
8 shared publications
Latest Publications
- 5 November 2026
- Published by Wiley in Electroanalysis
- Vol. 38 (11)
New Analytical Possibilities of Ion‐Selective Electrodes in Self‐Powered Bipolar Electrode Arrangement
All‐solid‐state potentiometric ion‐selective electrodes (ISEs) with plastic membranes are attractive analytical tools; however, their analytical parameters cannot be easily tuned by instrumental control. On the other hand, implementation of ISEs into bipolar electrode systems, working in self‐powered mode, opens new attractive analytical possibilities which are proposed and described in the present work. One of the tested options are bipolar electrode systems composed of connected cation‐ and anion‐selective electrodes. This setup results in a linear dependence of the current flowing across the bipolar system on the logarithm of electrolyte concentration. The signal magnitude, the slope of the calibration plot, and the detection limit can be modified by the change of the membrane thickness or its composition. An important advantage of this approach is that the reference electrode is not required. Additionally, by appropriately tailoring the composition of the bipolar electrode system, an analytically beneficial linear dependence of the current directly on ion concentration in a selected range can be achieved, including the physiological range of potassium ionsare concentration. In another application mode, as shown experimentally and confirmed by model calculations, bypassing a potentiometric sensor by another ISE can be effectively used for detection limit lowering of the sensor.
- 5 November 2026
- Published by Wiley in Electroanalysis
- Vol. 38 (11)
New Analytical Possibilities of Ion‐Selective Electrodes in Self‐Powered Bipolar Electrode Arrangement
All‐solid‐state potentiometric ion‐selective electrodes (ISEs) with plastic membranes are attractive analytical tools; however, their analytical parameters cannot be easily tuned by instrumental control. On the other hand, implementation of ISEs into bipolar electrode systems, working in self‐powered mode, opens new attractive analytical possibilities which are proposed and described in the present work. One of the tested options are bipolar electrode systems composed of connected cation‐ and anion‐selective electrodes. This setup results in a linear dependence of the current flowing across the bipolar system on the logarithm of electrolyte concentration. The signal magnitude, the slope of the calibration plot, and the detection limit can be modified by the change of the membrane thickness or its composition. An important advantage of this approach is that the reference electrode is not required. Additionally, by appropriately tailoring the composition of the bipolar electrode system, an analytically beneficial linear dependence of the current directly on ion concentration in a selected range can be achieved, including the physiological range of potassium ionsare concentration. In another application mode, as shown experimentally and confirmed by model calculations, bypassing a potentiometric sensor by another ISE can be effectively used for detection limit lowering of the sensor.
- Open Access
Balancing Selectivity and Cross-Sensitivity in Smart Tongue Sensing—Multimode, Multiplexed Optical Sensor Arrays for Dietary Supplement Classification
Achieving both universality and robustness in smart sensing remains a central yet unresolved challenge. Herein, we move beyond the conventional dichotomy of selective versus cross-sensitive sensors by demonstrating their synergistic integration within differential sensing architectures. Optical micro- and nanoparticle-based sensors—both selective (UW) and cross-sensitive (WUT)—were rationally combined to construct information-rich sensing arrays. Performance enhancement was explored considering three complementary strategies: the reduction of inter-sensor redundancy, the exploitation of full spectral fingerprints and multimode optical readout. Across independent datasets, log F analysis uncovered pronounced context-dependent chemosensitive particle behavior, enabling the identification of task-specific leading nanostructures while confirming metric robustness. Full-spectrum chemometric modeling delivered consistently high classification accuracy without overfitting, where SVM-DA excelled in resolving complex multiclass problems. Collectively, this work establishes a generalizable framework for engineering adaptive, high-dimensional sensing platforms, advancing the design of next-generation smart analytical systems, including smart noses and smart tongues.
Open AccessBalancing Selectivity and Cross-Sensitivity in Smart Tongue Sensing—Multimode, Multiplexed Optical Sensor Arrays for Dietary Supplement Classification
Achieving both universality and robustness in smart sensing remains a central yet unresolved challenge. Herein, we move beyond the conventional dichotomy of selective versus cross-sensitive sensors by demonstrating their synergistic integration within differential sensing architectures. Optical micro- and nanoparticle-based sensors—both selective (UW) and cross-sensitive (WUT)—were rationally combined to construct information-rich sensing arrays. Performance enhancement was explored considering three complementary strategies: the reduction of inter-sensor redundancy, the exploitation of full spectral fingerprints and multimode optical readout. Across independent datasets, log F analysis uncovered pronounced context-dependent chemosensitive particle behavior, enabling the identification of task-specific leading nanostructures while confirming metric robustness. Full-spectrum chemometric modeling delivered consistently high classification accuracy without overfitting, where SVM-DA excelled in resolving complex multiclass problems. Collectively, this work establishes a generalizable framework for engineering adaptive, high-dimensional sensing platforms, advancing the design of next-generation smart analytical systems, including smart noses and smart tongues.
- Open Access
- 8 September 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 469
Porphyrin optical transducer for ion-selective optodes operating in highly acidic range
- 8 September 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 469
Open AccessPorphyrin optical transducer for ion-selective optodes operating in highly acidic range
- Open Access
- 19 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (34) , 24662-24668
All-3D Printed Microelectrodes
In this work, microelectrodes were prepared entirely by the fused deposition modeling 3D printing method. The obtained systems were characterized with good reproducibility in terms of electrode area and electrochemical performance typical for microelectrodes. Application of 3D-printed microelectrodes in voltammetric pH sensing, postmodification with redox-active, pH-dependent reagent syringaldazine, highlights the effect of electrode housing materials. It is clearly shown that application of poly(lactic acid), the most common polymer used for preparation of electrochemical sensors using the 3D printing approach, results in local stabilization of the pH close to the microelectrode. This effect results from spontaneous hydrolysis of poly(lactic acid) and formation of products locally buffering pH or partially blocking the electrode active surface. Thus, to prepare miniature pH voltammetric sensors, a glycol-modified polyethylene terephthalate filament was used to prepare microelectrode housing. The obtained microelectrode sensors were characterized with a linear Nernstian dependence of the redox peak positions on pH within the range from 9 to 3.
- 19 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (34) , 24662-24668
Open AccessAll-3D Printed Microelectrodes
In this work, microelectrodes were prepared entirely by the fused deposition modeling 3D printing method. The obtained systems were characterized with good reproducibility in terms of electrode area and electrochemical performance typical for microelectrodes. Application of 3D-printed microelectrodes in voltammetric pH sensing, postmodification with redox-active, pH-dependent reagent syringaldazine, highlights the effect of electrode housing materials. It is clearly shown that application of poly(lactic acid), the most common polymer used for preparation of electrochemical sensors using the 3D printing approach, results in local stabilization of the pH close to the microelectrode. This effect results from spontaneous hydrolysis of poly(lactic acid) and formation of products locally buffering pH or partially blocking the electrode active surface. Thus, to prepare miniature pH voltammetric sensors, a glycol-modified polyethylene terephthalate filament was used to prepare microelectrode housing. The obtained microelectrode sensors were characterized with a linear Nernstian dependence of the redox peak positions on pH within the range from 9 to 3.
- Open Access
- 18 August 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (64) , 15953-15956
Electrospun nanofibers meet paper: a planar system for voltammetric ion sensing
Chromatographic paper and electrospun PVC nanofibers stabilise aqueous and organic phases, paving the way for point-of-care sensing using ITIES (ion transfer voltammetry at the interface of two immiscible electrolytes).
- 18 August 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (64) , 15953-15956
Open AccessElectrospun nanofibers meet paper: a planar system for voltammetric ion sensing
Chromatographic paper and electrospun PVC nanofibers stabilise aqueous and organic phases, paving the way for point-of-care sensing using ITIES (ion transfer voltammetry at the interface of two immiscible electrolytes).
- Open Access
- 11 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (11) , 18234-18240
Potentiometric Bipolar Batteries for Ion Sensing. 3D Printed Comb Sensors
We propose a concept leading to pronounced sensitivity increase of potentiometric analysis based on application of potentiometric bipolar batteries. The system is composed of an array of individual cells; each of them is comprising an ion-selective electrode (ISE) and a reference silver/silver chloride electrode. The cells are connected in series in the absence of additional wiring but form closed bipolar electrode systems composed of ISE and the reference electrode of the neighboring cell. Advantageously, the cell arrays are produced by a 3D printing method using biodegradable polylactide filaments. Potentiometric studies were carried out on model examples of potassium ISEs, supplemented by results obtained also for calcium-ISES to compare the role of the analyte ion charge. It was found that the recorded slope of linear dependence of the voltage on logarithm of potassium and calcium ions activity corresponds to the Nernstian value multiplied by the number of cells. The selectivity of the proposed system with potassium-ISE is high and equal to that of a single electrode. This approach was found applicable for real samples within physiological range of potassium ions concentration; moreover, due to enhanced sensitivity, a linear dependence of the voltage directly on potassium ions concentration in physiological range was obtained, with concentration resolution error smaller than 1%.
- 11 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (11) , 18234-18240
Open AccessPotentiometric Bipolar Batteries for Ion Sensing. 3D Printed Comb Sensors
We propose a concept leading to pronounced sensitivity increase of potentiometric analysis based on application of potentiometric bipolar batteries. The system is composed of an array of individual cells; each of them is comprising an ion-selective electrode (ISE) and a reference silver/silver chloride electrode. The cells are connected in series in the absence of additional wiring but form closed bipolar electrode systems composed of ISE and the reference electrode of the neighboring cell. Advantageously, the cell arrays are produced by a 3D printing method using biodegradable polylactide filaments. Potentiometric studies were carried out on model examples of potassium ISEs, supplemented by results obtained also for calcium-ISES to compare the role of the analyte ion charge. It was found that the recorded slope of linear dependence of the voltage on logarithm of potassium and calcium ions activity corresponds to the Nernstian value multiplied by the number of cells. The selectivity of the proposed system with potassium-ISE is high and equal to that of a single electrode. This approach was found applicable for real samples within physiological range of potassium ions concentration; moreover, due to enhanced sensitivity, a linear dependence of the voltage directly on potassium ions concentration in physiological range was obtained, with concentration resolution error smaller than 1%.
- Open Access
- 29 January 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (4) , 543-551
Applicability of a bipolar electrode arrangement involving ion-selective electrodes in vertical farming, with the self-controlled supply of macro- and microcomponents
All-solid-state potentiometric ion-selective electrodes (ISEs) with plastic membranes are attractive analytical tools due to the simplicity of the apparatus and their ease of use. The implementation of ISEs into a bipolar electrode system working in self-powered mode would open new and attractive possibilities, far beyond typical analytical purposes. In the present work, the applicability of such systems for vertical farming, e.g., in hydroponics, is evaluated as a proof of concept. This approach can be used for long-term monitoring of the concentration of electrolytes (macrocomponents, e.g., potassium or chloride ions) in solutions. Another innovative application proposed herein utilizes the properties of the bipolar electrode system to allow for self-adjustment of the concentrations of components via spontaneous charge transfer processes occurring at both poles of the bipolar electrode. We demonstrate that a self-powered bipolar electrode system composed of an active metal (zinc) and an ISE can be applied for the controlled release of minute amounts of microelements, in this case, zinc ions. The ion flux is selectively controlled by a chemical stimulus, namely, the composition and concentration of a neutral electrolyte (macrocomponents), as well as the properties of the bipolar electrode system.
- 29 January 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (4) , 543-551
Open AccessApplicability of a bipolar electrode arrangement involving ion-selective electrodes in vertical farming, with the self-controlled supply of macro- and microcomponents
All-solid-state potentiometric ion-selective electrodes (ISEs) with plastic membranes are attractive analytical tools due to the simplicity of the apparatus and their ease of use. The implementation of ISEs into a bipolar electrode system working in self-powered mode would open new and attractive possibilities, far beyond typical analytical purposes. In the present work, the applicability of such systems for vertical farming, e.g., in hydroponics, is evaluated as a proof of concept. This approach can be used for long-term monitoring of the concentration of electrolytes (macrocomponents, e.g., potassium or chloride ions) in solutions. Another innovative application proposed herein utilizes the properties of the bipolar electrode system to allow for self-adjustment of the concentrations of components via spontaneous charge transfer processes occurring at both poles of the bipolar electrode. We demonstrate that a self-powered bipolar electrode system composed of an active metal (zinc) and an ISE can be applied for the controlled release of minute amounts of microelements, in this case, zinc ions. The ion flux is selectively controlled by a chemical stimulus, namely, the composition and concentration of a neutral electrolyte (macrocomponents), as well as the properties of the bipolar electrode system.