Lingxiao Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lingxiao Yang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Stephen A. Boppart
University of Illinois Urbana-Champaign
12 shared publications - Janet E. Sorrells
Department of Electrical & Systems Engineering, Washington University in St. Louis, St. Louis, MO 63130, USA
10 shared publications - Rishyashring R. Iyer
Department of Physics, University of California, San Diego, La Jolla, USA
10 shared publications - Darold R. Spillman
Univ. of Illinois (United States)
5 shared publications Eric J. Chaney
University of Illinois Urbana-Champaign
5 shared publications- Carlos A. Renteria
University of Illinois Urbana-Champaign
4 shared publications
Latest Publications
- 10 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 4010-4013
Polarimetric coherent anti-Stokes Raman scattering microscopy of collagen
We demonstrate polarimetric coherent anti-Stokes Raman scattering (PCARS) microscopy for quantitative analysis of collagen orientation. Using polarization-modulated excitation and cross-polarized detection, we extract both chemical and orientational information from intact tissues. We introduce two complementary analyses: the CARS peak polarization ratio (PPR) and Fourier domain polarimetric analysis, providing a robust characterization of collagen organization. This method enables rapid, label-free imaging of a collagen structure with molecular specificity, offering what we believe to be new capabilities for studying collagen remodeling in biological processes.
- 10 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 4010-4013
Polarimetric coherent anti-Stokes Raman scattering microscopy of collagen
We demonstrate polarimetric coherent anti-Stokes Raman scattering (PCARS) microscopy for quantitative analysis of collagen orientation. Using polarization-modulated excitation and cross-polarized detection, we extract both chemical and orientational information from intact tissues. We introduce two complementary analyses: the CARS peak polarization ratio (PPR) and Fourier domain polarimetric analysis, providing a robust characterization of collagen organization. This method enables rapid, label-free imaging of a collagen structure with molecular specificity, offering what we believe to be new capabilities for studying collagen remodeling in biological processes.
- 19 September 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (9) , 1352-1367
Exploring the structure, metabolism, and biochemistry of the neuronal microenvironment label-free using fast simultaneous multimodal optical microscopy
The technologies to examine the neuronal microenvironment label free remain critically underexplored. There is a gap in our knowledge of underlying metabolic, biochemical, and electrophysiological mechanisms behind several neurological processes at a cellular level, which can be traced to the lack of versatile and high-throughput tools to investigate neural networks. In this paper, four label-free contrasts were explored as mechanisms to study neuronal activity, namely, scattering, birefringence, autofluorescence from metabolic cofactors and molecules, and local biochemistry. To overcome challenges of observing neuronal activity spanning three orders of magnitude in space and time, microscopes had to be developed to simultaneously capture these contrasts quickly, with high resolution, and over a large FOV. We developed versatile autofluorescence lifetime, multiharmonic generation, polarization-sensitive interferometry, and Raman imaging in epi-detection (VAMPIRE) microscopy to simultaneously observe multiple facets of neuronal structure and dynamics. The accelerated computational-imaging-driven acquisition speeds, the utilization of a single light source to evoke all contrasts, the simultaneous acquisition that provides an otherwise impossible multimodal dynamic imaging capability, and the real-time processing of the data enable VAMPIRE microscopy as a powerful imaging platform for neurophotonics and beyond.
- 19 September 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (9) , 1352-1367
Exploring the structure, metabolism, and biochemistry of the neuronal microenvironment label-free using fast simultaneous multimodal optical microscopy
The technologies to examine the neuronal microenvironment label free remain critically underexplored. There is a gap in our knowledge of underlying metabolic, biochemical, and electrophysiological mechanisms behind several neurological processes at a cellular level, which can be traced to the lack of versatile and high-throughput tools to investigate neural networks. In this paper, four label-free contrasts were explored as mechanisms to study neuronal activity, namely, scattering, birefringence, autofluorescence from metabolic cofactors and molecules, and local biochemistry. To overcome challenges of observing neuronal activity spanning three orders of magnitude in space and time, microscopes had to be developed to simultaneously capture these contrasts quickly, with high resolution, and over a large FOV. We developed versatile autofluorescence lifetime, multiharmonic generation, polarization-sensitive interferometry, and Raman imaging in epi-detection (VAMPIRE) microscopy to simultaneously observe multiple facets of neuronal structure and dynamics. The accelerated computational-imaging-driven acquisition speeds, the utilization of a single light source to evoke all contrasts, the simultaneous acquisition that provides an otherwise impossible multimodal dynamic imaging capability, and the real-time processing of the data enable VAMPIRE microscopy as a powerful imaging platform for neurophotonics and beyond.
- Open Access
- 1 July 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (7) , 076114
Dispersion mismatch correction for evident chromatic anomaly in low coherence interferometry
The applications of ultrafast optics to biomedical microscopy have expanded rapidly in recent years, including interferometric techniques like optical coherence tomography and microscopy (OCT/OCM). The advances of ultra-high resolution OCT and the inclusion of OCT/OCM in multimodal systems combined with multiphoton microscopy have marked a transition from using pseudo-continuous broadband sources, such as superluminescent diodes, to ultrafast supercontinuum optical sources. We report anomalies in the dispersion profiles of low-coherence ultrafast pulses through long and non-identical arms of a Michelson interferometer that are well beyond group delay or third-order dispersions. This chromatic anomaly worsens the observed axial resolution and causes fringe artifacts in the reconstructed tomograms in OCT/OCM using traditional algorithms. We present DISpersion COmpensation Techniques for Evident Chromatic Anomalies (DISCOTECA) as a universal solution to address the problem of chromatic dispersion mismatch in interferometry, especially with ultrafast sources. First, we demonstrate the origin of these artifacts through the self-phase modulation of ultrafast pulses due to focusing elements in the beam path. Next, we present three solution paradigms for DISCOTECA: optical, optoelectronic, and computational, along with quantitative comparisons to traditional methods to highlight the improvements to the dynamic range and axial profile. We explain the piecewise reconstruction of the phase mismatch between the arms of the spectral-domain interferometer using a modified short-term Fourier transform algorithm inspired by spectroscopic OCT. Finally, we present a decision-making guide for evaluating the utility of DISCOTECA in interferometry and for the artifact-free reconstruction of OCT images using an ultrafast supercontinuum source for biomedical applications.
- 1 July 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (7) , 076114
Open AccessDispersion mismatch correction for evident chromatic anomaly in low coherence interferometry
The applications of ultrafast optics to biomedical microscopy have expanded rapidly in recent years, including interferometric techniques like optical coherence tomography and microscopy (OCT/OCM). The advances of ultra-high resolution OCT and the inclusion of OCT/OCM in multimodal systems combined with multiphoton microscopy have marked a transition from using pseudo-continuous broadband sources, such as superluminescent diodes, to ultrafast supercontinuum optical sources. We report anomalies in the dispersion profiles of low-coherence ultrafast pulses through long and non-identical arms of a Michelson interferometer that are well beyond group delay or third-order dispersions. This chromatic anomaly worsens the observed axial resolution and causes fringe artifacts in the reconstructed tomograms in OCT/OCM using traditional algorithms. We present DISpersion COmpensation Techniques for Evident Chromatic Anomalies (DISCOTECA) as a universal solution to address the problem of chromatic dispersion mismatch in interferometry, especially with ultrafast sources. First, we demonstrate the origin of these artifacts through the self-phase modulation of ultrafast pulses due to focusing elements in the beam path. Next, we present three solution paradigms for DISCOTECA: optical, optoelectronic, and computational, along with quantitative comparisons to traditional methods to highlight the improvements to the dynamic range and axial profile. We explain the piecewise reconstruction of the phase mismatch between the arms of the spectral-domain interferometer using a modified short-term Fourier transform algorithm inspired by spectroscopic OCT. Finally, we present a decision-making guide for evaluating the utility of DISCOTECA in interferometry and for the artifact-free reconstruction of OCT images using an ultrafast supercontinuum source for biomedical applications.
- 1 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (9) , 2513-2516
Programmable hyperspectral coherent anti-Stokes Raman scattering microscopy
Hyperspectral coherent Raman scattering microscopy provides a significant improvement in acquisition time compared to spontaneous Raman scattering yet still suffers from the time required to sweep through individual wavenumbers. To address this, we present the use of a pulse shaper with a 2D spatial light modulator for phase- and amplitude-based shaping of the Stokes beam to create programmable spectrally tailored excitation envelopes. This enables collection of useful spectral information in a more rapid and efficient manner.
- 1 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (9) , 2513-2516
Programmable hyperspectral coherent anti-Stokes Raman scattering microscopy
Hyperspectral coherent Raman scattering microscopy provides a significant improvement in acquisition time compared to spontaneous Raman scattering yet still suffers from the time required to sweep through individual wavenumbers. To address this, we present the use of a pulse shaper with a 2D spatial light modulator for phase- and amplitude-based shaping of the Stokes beam to create programmable spectrally tailored excitation envelopes. This enables collection of useful spectral information in a more rapid and efficient manner.
- 13 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (7) , 11474-11490
Temporally optimized and spectrally shaped hyperspectral coherent anti-Stokes Raman scattering microscopy
Coherent anti-Stokes Raman scattering (CARS) microscopy offers label-free chemical contrasts based on molecular vibrations. Hyperspectral CARS (HS-CARS) microscopy enables comprehensive microscale chemical characterization of biological samples. Various HS-CARS methods have been developed with individual advantages and disadvantages. We present what we believe to be a new temporally optimized and spectrally shaped (TOSS) HS-CARS method to overcome the limitations of existing techniques by providing precise control of the spatial and temporal profiles of the excitation beams for efficient and accurate measurements. This method uniquely uses Fourier transform pulse shaping based on a two-dimensional spatial light modulator to control the phase and amplitude of the excitation beams. TOSS-HS-CARS achieves fast, stable, and flexible acquisition, minimizes photodamage, and is highly adaptable to a multimodal multiphoton imaging system.
- 13 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (7) , 11474-11490
Temporally optimized and spectrally shaped hyperspectral coherent anti-Stokes Raman scattering microscopy
Coherent anti-Stokes Raman scattering (CARS) microscopy offers label-free chemical contrasts based on molecular vibrations. Hyperspectral CARS (HS-CARS) microscopy enables comprehensive microscale chemical characterization of biological samples. Various HS-CARS methods have been developed with individual advantages and disadvantages. We present what we believe to be a new temporally optimized and spectrally shaped (TOSS) HS-CARS method to overcome the limitations of existing techniques by providing precise control of the spatial and temporal profiles of the excitation beams for efficient and accurate measurements. This method uniquely uses Fourier transform pulse shaping based on a two-dimensional spatial light modulator to control the phase and amplitude of the excitation beams. TOSS-HS-CARS achieves fast, stable, and flexible acquisition, minimizes photodamage, and is highly adaptable to a multimodal multiphoton imaging system.
- 4 March 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (4) , 2048-2062
Analog multiplexing of a laser clock and computational photon counting for fast fluorescence lifetime imaging microscopy
The dynamic range and fluctuations of fluorescence intensities and lifetimes in biological samples are large, demanding fast, precise, and versatile techniques. Among the high-speed fluorescence lifetime imaging microscopy (FLIM) techniques, directly sampling the output of analog single-photon detectors at GHz rates combined with computational photon counting can handle a larger range of photon rates. Traditionally, the laser clock is not sampled explicitly in fast FLIM; rather the detection is synchronized to the laser clock so that the excitation pulse train can be inferred from the cumulative photon statistics of several pixels. This has two disadvantages for sparse or weakly fluorescent samples: inconsistencies in inferring the laser clock within a frame and inaccuracies in aligning the decay curves from different frames for averaging. The data throughput is also very inefficient in systems with repetition rates much larger than the fluorescence lifetime due to significant silent regions where no photons are expected. We present a method for registering the photon arrival times to the excitation using time-domain multiplexing for fast FLIM. The laser clock is multiplexed with photocurrents into the silent region. Our technique does not add to the existing data bottleneck, has the sub-nanosecond dead time of computational photon counting based fast FLIM, works with various detectors, lasers, and electronics, and eliminates the errors in lifetime estimation in photon-starved conditions. We demonstrate this concept on two multiphoton setups of different laser repetition rates for single and multichannel FLIM multiplexed into a single digitizer channel for real-time imaging of biological samples.
- 4 March 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (4) , 2048-2062
Analog multiplexing of a laser clock and computational photon counting for fast fluorescence lifetime imaging microscopy
The dynamic range and fluctuations of fluorescence intensities and lifetimes in biological samples are large, demanding fast, precise, and versatile techniques. Among the high-speed fluorescence lifetime imaging microscopy (FLIM) techniques, directly sampling the output of analog single-photon detectors at GHz rates combined with computational photon counting can handle a larger range of photon rates. Traditionally, the laser clock is not sampled explicitly in fast FLIM; rather the detection is synchronized to the laser clock so that the excitation pulse train can be inferred from the cumulative photon statistics of several pixels. This has two disadvantages for sparse or weakly fluorescent samples: inconsistencies in inferring the laser clock within a frame and inaccuracies in aligning the decay curves from different frames for averaging. The data throughput is also very inefficient in systems with repetition rates much larger than the fluorescence lifetime due to significant silent regions where no photons are expected. We present a method for registering the photon arrival times to the excitation using time-domain multiplexing for fast FLIM. The laser clock is multiplexed with photocurrents into the silent region. Our technique does not add to the existing data bottleneck, has the sub-nanosecond dead time of computational photon counting based fast FLIM, works with various detectors, lasers, and electronics, and eliminates the errors in lifetime estimation in photon-starved conditions. We demonstrate this concept on two multiphoton setups of different laser repetition rates for single and multichannel FLIM multiplexed into a single digitizer channel for real-time imaging of biological samples.
- 25 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (2) , 155-165
Label-free multimodal polarization-sensitive optical microscope for multiparametric quantitative characterization of collagen
Collagen is an essential component of biological tissues with a variety of subtypes. To be able to capture these subtypes, fully exploit the polarization-sensitive light-collagen interactions, and provide comprehensive information of collagen, we integrated polarization-sensitive second-harmonic generation (PSHG) microscopy, polarization-sensitive optical coherence microscopy (PSOCM), and two-photon fluorescence lifetime imaging microscopy into a single-source multimodal system in a simultaneous and spatially co-registered configuration. PSOCM information is used in the PSHG numerical model to enable accurate PSHG analysis of unsectioned fresh tissue. This polarization-sensitive multimodal system provides quantitative multiparametric characterization of collagen and facilitates the fundamental understanding of collagen in the unperturbed tissue microenvironment, which can enable future studies into the role of collagen in various diseases.
- 25 January 2024
- Published by Optica Publishing Group in Optica
- Vol. 11 (2) , 155-165
Label-free multimodal polarization-sensitive optical microscope for multiparametric quantitative characterization of collagen
Collagen is an essential component of biological tissues with a variety of subtypes. To be able to capture these subtypes, fully exploit the polarization-sensitive light-collagen interactions, and provide comprehensive information of collagen, we integrated polarization-sensitive second-harmonic generation (PSHG) microscopy, polarization-sensitive optical coherence microscopy (PSOCM), and two-photon fluorescence lifetime imaging microscopy into a single-source multimodal system in a simultaneous and spatially co-registered configuration. PSOCM information is used in the PSHG numerical model to enable accurate PSHG analysis of unsectioned fresh tissue. This polarization-sensitive multimodal system provides quantitative multiparametric characterization of collagen and facilitates the fundamental understanding of collagen in the unperturbed tissue microenvironment, which can enable future studies into the role of collagen in various diseases.
- Open Access
- 24 June 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (9) , e202200105
Tracking the binding of multi‐functional fluorescent tags for Alzheimer's disease using quantitative multiphoton microscopy
A recent theranostic approach to address Alzheimer's disease (AD) utilizes multifunctional targets that both tag and negate the toxicity of AD biomarkers. These compounds, which emit fluorescence with both an activation and a spectral shift in the presence of Aβ, were previously characterized with traditional fluorescence imaging for binary characterization. However, these multifunctional compounds have broad and dynamic emission spectra that are dependent on factors such as the local environment, presence of Aβ deposits, etc. Since quantitative multiphoton microscopy is sensitive to the binding dynamics of molecules, we characterized the performance of two such compounds, LS‐4 and ZY‐12‐OMe, using Simultaneous Label‐free Autofluorescence Multi‐harmonic (SLAM) microscopy and Fast Optical Coherence, Autofluorescence Lifetime imaging and Second harmonic generation (FOCALS) microscopy. This study shows that the combination of quantitative multiphoton imaging with multifunctional tags for AD offers new insights into the interaction of these tags with AD biomarkers and the theranostic mechanisms.
- 24 June 2022
- Published by Wiley in Journal of Biophotonics
- Vol. 15 (9) , e202200105
Open AccessTracking the binding of multi‐functional fluorescent tags for Alzheimer's disease using quantitative multiphoton microscopy
A recent theranostic approach to address Alzheimer's disease (AD) utilizes multifunctional targets that both tag and negate the toxicity of AD biomarkers. These compounds, which emit fluorescence with both an activation and a spectral shift in the presence of Aβ, were previously characterized with traditional fluorescence imaging for binary characterization. However, these multifunctional compounds have broad and dynamic emission spectra that are dependent on factors such as the local environment, presence of Aβ deposits, etc. Since quantitative multiphoton microscopy is sensitive to the binding dynamics of molecules, we characterized the performance of two such compounds, LS‐4 and ZY‐12‐OMe, using Simultaneous Label‐free Autofluorescence Multi‐harmonic (SLAM) microscopy and Fast Optical Coherence, Autofluorescence Lifetime imaging and Second harmonic generation (FOCALS) microscopy. This study shows that the combination of quantitative multiphoton imaging with multifunctional tags for AD offers new insights into the interaction of these tags with AD biomarkers and the theranostic mechanisms.
- Open Access
- 28 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056504-18
Label-free multimodal nonlinear optical imaging of needle biopsy cores for intraoperative cancer diagnosis
Cancer is the second leading cause of death in the United States1 and developing new technologies and methods for cancer diagnosis has been a major research field in biomedicine. For the diagnosis of cancer, especially in liver, lung, breast, prostate, and soft tissue tumors,2 it is a standard clinical practice to acquire and evaluate needle biopsy (NB) specimens before deciding on the treatment plan, such as the need for chemotherapy, radiation therapy, and/or surgical procedures.2 NB procedures include fine-needle aspiration, which often uses syringes to collect fluids for cytological evaluation, and core-needle biopsy, which collects tissue cores from suspicious regions.2 – 5 This study will focus on the collection and evaluation of NB core specimens, but the technologies and methods presented here could similarly be used to assess the cytologic content from fine-needle aspirations. NB core specimens are commonly fixed right after the acquisition and go through standard histological procedures including sectioning and staining.2 Although histopathology is the gold standard for cancer diagnosis, this conventional evaluation method often takes a day or more to generate the results.6,7 The time-consuming histological evaluation has become more of a concerning factor when the NB sampling is inadequate or non-diagnostic, which means the histology results of NB specimens fail to provide any diagnostic information, such as the presence of cancer cells. In this case, additional specimens are required, which further delays the diagnostic decisions.2,8 Therefore, there is a critical need to have a rapid screening and evaluation method of NB cores right after extraction and at the point-of-procedure.
- 28 May 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (05) , 056504-18
Open AccessLabel-free multimodal nonlinear optical imaging of needle biopsy cores for intraoperative cancer diagnosis
Cancer is the second leading cause of death in the United States1 and developing new technologies and methods for cancer diagnosis has been a major research field in biomedicine. For the diagnosis of cancer, especially in liver, lung, breast, prostate, and soft tissue tumors,2 it is a standard clinical practice to acquire and evaluate needle biopsy (NB) specimens before deciding on the treatment plan, such as the need for chemotherapy, radiation therapy, and/or surgical procedures.2 NB procedures include fine-needle aspiration, which often uses syringes to collect fluids for cytological evaluation, and core-needle biopsy, which collects tissue cores from suspicious regions.2 – 5 This study will focus on the collection and evaluation of NB core specimens, but the technologies and methods presented here could similarly be used to assess the cytologic content from fine-needle aspirations. NB core specimens are commonly fixed right after the acquisition and go through standard histological procedures including sectioning and staining.2 Although histopathology is the gold standard for cancer diagnosis, this conventional evaluation method often takes a day or more to generate the results.6,7 The time-consuming histological evaluation has become more of a concerning factor when the NB sampling is inadequate or non-diagnostic, which means the histology results of NB specimens fail to provide any diagnostic information, such as the presence of cancer cells. In this case, additional specimens are required, which further delays the diagnostic decisions.2,8 Therefore, there is a critical need to have a rapid screening and evaluation method of NB cores right after extraction and at the point-of-procedure.
- 29 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (23) , 37759-37775
Single-photon peak event detection (SPEED): a computational method for fast photon counting in fluorescence lifetime imaging microscopy
Fluorescence lifetime imaging microscopy (FLIM) characterizes samples by examining the temporal properties of fluorescence emission, providing useful contrast within samples based on the local physical and biochemical environment of fluorophores. Despite this, FLIM applications have been limited in scope by either poor accuracy or long acquisition times. Here, we present a method for computational single-photon counting of directly sampled time-domain FLIM data that is capable of accurate fluorescence lifetime and intensity measurements while acquiring over 160 Mega-counts-per-second with sub-nanosecond time resolution between consecutive photon counts. We demonstrate that our novel method of Single-photon PEak Event Detection (SPEED) is more accurate than direct pulse sampling and faster than established photon counting FLIM methods. We further show that SPEED can be implemented for imaging and quantifying samples that benefit from higher -throughput and -dynamic range imaging with real-time GPU-accelerated processing and use this capability to examine the NAD(P)H-related metabolic dynamics of apoptosis in human breast cancer cells. Computational methods for photon counting such as SPEED open up more opportunities for fast and accurate FLIM imaging and additionally provide a basis for future innovation into alternative FLIM techniques.
- 29 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (23) , 37759-37775
Single-photon peak event detection (SPEED): a computational method for fast photon counting in fluorescence lifetime imaging microscopy
Fluorescence lifetime imaging microscopy (FLIM) characterizes samples by examining the temporal properties of fluorescence emission, providing useful contrast within samples based on the local physical and biochemical environment of fluorophores. Despite this, FLIM applications have been limited in scope by either poor accuracy or long acquisition times. Here, we present a method for computational single-photon counting of directly sampled time-domain FLIM data that is capable of accurate fluorescence lifetime and intensity measurements while acquiring over 160 Mega-counts-per-second with sub-nanosecond time resolution between consecutive photon counts. We demonstrate that our novel method of Single-photon PEak Event Detection (SPEED) is more accurate than direct pulse sampling and faster than established photon counting FLIM methods. We further show that SPEED can be implemented for imaging and quantifying samples that benefit from higher -throughput and -dynamic range imaging with real-time GPU-accelerated processing and use this capability to examine the NAD(P)H-related metabolic dynamics of apoptosis in human breast cancer cells. Computational methods for photon counting such as SPEED open up more opportunities for fast and accurate FLIM imaging and additionally provide a basis for future innovation into alternative FLIM techniques.