Mohammad Javad Salehpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Javad Salehpour has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jin Wang
School of Computer & Communication Engineering Changsha University of Science & Technology Changsha China
2 shared publications- Jin Wang
School of Computer Science and Engineering, Hunan University of Science and Technology, Xiangtan, China
2 shared publications Omid Zarenia
Electrical Engineering Department University of Guilan Rasht Iran
2 shared publications- Seyyed Mohammad Hosseini Rostami
Shiraz University of Technology
2 shared publications - Behnam Rasouli
Electrical Engineering Department, University of Guilan, Rasht 4199613776, Iran
1 shared publication - Gwang-Jun Kim
Chonnam Natl Univ, Dept Comp Engn, Gwangju 61186, South Korea
1 shared publication
Latest Publications
- Open Access
- 8 October 2025
- Published by Elsevier in Energy Policy
- Vol. 208
AI-powered vehicle-to-home energy management for grid outage response: A pathway to policy-ready energy resilience
- 8 October 2025
- Published by Elsevier in Energy Policy
- Vol. 208
Open AccessAI-powered vehicle-to-home energy management for grid outage response: A pathway to policy-ready energy resilience
- 1 June 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (8) , e12925
Simultaneous components sizing and flight scheduling for an hybrid aerial vehicle as a multi‐energy mobile microgrid
- 1 June 2021
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (8) , e12925
Simultaneous components sizing and flight scheduling for an hybrid aerial vehicle as a multi‐energy mobile microgrid
- 16 April 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (7)
Convex multi‐objective optimization for a hybrid fuel cell power system of more electric aircraft
- 16 April 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 30 (7)
Convex multi‐objective optimization for a hybrid fuel cell power system of more electric aircraft
- Open Access
- 14 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4872
Optimal Day-Ahead Scheduling of a Smart Micro-Grid via a Probabilistic Model for Considering the Uncertainty of Electric Vehicles’ Load
This paper presents a new model based on the Monte Carlo simulation method for considering the uncertainty of electric vehicles’ charging station’s load in a day-ahead operation optimization of a smart micro-grid. In the proposed model, some uncertain effective factors on the electric vehicles’ charging station’s load including battery capacity, type of electric vehicles, state of charge, charging power level and response to energy price changes are considered. In addition, other uncertainties of operating parameters such as market price, photovoltaic generation and loads are also considered. Therefore, various stochastic scenarios are generated and involved in a cost minimization problem, which is formulated in the form of mixed-integer linear programming. Finally, the proposed model is simulated on a typical micro-grid with two 60 kW micro-turbines, a 60 kW photovoltaic unit and some loads. The results showed that by applying the proposed model for estimation of charging station load, the total operation cost decreased.
- 14 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (22) , 4872
Open AccessOptimal Day-Ahead Scheduling of a Smart Micro-Grid via a Probabilistic Model for Considering the Uncertainty of Electric Vehicles’ Load
This paper presents a new model based on the Monte Carlo simulation method for considering the uncertainty of electric vehicles’ charging station’s load in a day-ahead operation optimization of a smart micro-grid. In the proposed model, some uncertain effective factors on the electric vehicles’ charging station’s load including battery capacity, type of electric vehicles, state of charge, charging power level and response to energy price changes are considered. In addition, other uncertainties of operating parameters such as market price, photovoltaic generation and loads are also considered. Therefore, various stochastic scenarios are generated and involved in a cost minimization problem, which is formulated in the form of mixed-integer linear programming. Finally, the proposed model is simulated on a typical micro-grid with two 60 kW micro-turbines, a 60 kW photovoltaic unit and some loads. The results showed that by applying the proposed model for estimation of charging station load, the total operation cost decreased.
- Open Access
- 8 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3241
Effect of Load Priority Modeling on the Size of Fuel Cell as an Emergency Power Unit in a More-Electric Aircraft
The proton exchange membrane fuel cell as a green power source is a suitable replacement of the engine mounted generators in the emergency power unit of a more-electric aircraft. Most existing energy management methods for operation of fuel cells in the more-electric aircraft refer to the hydrogen consumption minimization. But due to the increasing number of electrical components and hence electrical demand in the aircraft, demand-side management should be considered in these methods. In order to determine the effect of demand-side management on the fuel cell operation and size, an efficient load priority model is presented and integrated into an optimization framework. The proposed optimization framework is formulated as mixed-integer quadratic programming using Karush–Kuhn–Tucker optimality condition and is solved by CPLEX optimization tool. The Boeing 787 electrical distribution system is considered as a single-bus case study to evaluate the performance of the proposed optimization framework. Numerical results show that the size of fuel cell as an emergency power unit resource depends on the type and importance of the system’s loads in different emergency conditions. Also, with an efficient priority model, both hydrogen consumption and load shedding can be decreased.
- 8 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3241
Open AccessEffect of Load Priority Modeling on the Size of Fuel Cell as an Emergency Power Unit in a More-Electric Aircraft
The proton exchange membrane fuel cell as a green power source is a suitable replacement of the engine mounted generators in the emergency power unit of a more-electric aircraft. Most existing energy management methods for operation of fuel cells in the more-electric aircraft refer to the hydrogen consumption minimization. But due to the increasing number of electrical components and hence electrical demand in the aircraft, demand-side management should be considered in these methods. In order to determine the effect of demand-side management on the fuel cell operation and size, an efficient load priority model is presented and integrated into an optimization framework. The proposed optimization framework is formulated as mixed-integer quadratic programming using Karush–Kuhn–Tucker optimality condition and is solved by CPLEX optimization tool. The Boeing 787 electrical distribution system is considered as a single-bus case study to evaluate the performance of the proposed optimization framework. Numerical results show that the size of fuel cell as an emergency power unit resource depends on the type and importance of the system’s loads in different emergency conditions. Also, with an efficient priority model, both hydrogen consumption and load shedding can be decreased.
- 1 March 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 106, 546-560
The effect of price responsive loads uncertainty on the risk-constrained optimal operation of a smart micro-grid
- 1 March 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 106, 546-560
The effect of price responsive loads uncertainty on the risk-constrained optimal operation of a smart micro-grid