Melanie L. Yarbrough
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Melanie L. Yarbrough has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Carey-Ann D. Burnham
Departments of Pediatrics, Washington University School of Medicine, St. Louis, MO 63110, USA
17 shared publications - Kim Orth
Department of Molecular Biology, University of Texas Southwestern Medical Center
7 shared publications Meghan A. Wallace
Department of Pathology and Immunology, Division of Laboratory and Genomic Medicine, Washington University School of Medicine, St. Louis, USA
7 shared publications- David K. Warren
University of Nebraska Medical Center
6 shared publications Carey-Ann D. Burnham
Department of Pathology and Immunology, Washington University School of Medicine, Saint Louis, Missouri
5 shared publications- William Lainhart
Division of Infectious Diseases, University of Arizona College of Medicine, Tucson, AZ 85724, USA
5 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by American Society for Microbiology in Microbiology Spectrum
A multicenter performance evaluation of imipenem-relebactam gradient diffusion susceptibility testing for Pseudomonas aeruginosa
Imipenem-relebactam (I/R) is a beta-lactam/beta-lactamase inhibitor combination given with cilastatin that is indicated for the treatment of complicated urinary tract infections, including pyelonephritis and complicated intra-abdominal infections in patients. Recently, a new gradient diffusion method for antimicrobial susceptibility testing of this antibiotic was developed for Pseudomonas aeruginosa (ETEST IRPA) as an alternative to broth microdilution (BMD). Our objective was to evaluate the performance of the I/R ETEST in comparison to BMD across three external and one internal study sites for 437 (77 challenge, 360 clinical) P. aeruginosa isolates. Using the U.S. Food and Drug Administration (FDA) interpretive breakpoints, ETEST IRPA achieved a 97.7% (427/437) essential agreement (EA), 91.1% (398/437) categorical agreement (CA), 0% very major errors (VMEs), 0.9% (3/329) major errors (MEs), and 8.2% (36/437) minor errors (mEs). Using the European Committee on Antimicrobial Susceptibility Testing (EUCAST) interpretive breakpoints, ETEST IRPA achieved a 97.7% (427/437) EA, 93.8% (410/437) CA, 12% (13/108) VME, and 4.2% (14/329) ME. Both bias and trending were in alignment with regulatory requirements. Reproducibility testing on 10 strains showed 99.6% (269/270) of results were within ±1 doubling dilution of the modal minimum inhibitory concentration (MIC). MIC 50 and MIC 90 values for imipenem were 8 and 32, respectively, in comparison to 1 and 8 with the addition of relebactam as determined by ETEST. In conclusion, ETEST IRPA provides both accurate and reproducible results for performing antimicrobial susceptibility testing of P. aeruginosa when interpreted with both FDA and EUCAST criteria. IMPORTANCE: Antimicrobial susceptibility testing is key to proper treatment of bacterial infections. Broth microdilution is the gold standard for antimicrobial susceptibility testing; however, it can be time-consuming and requires high levels of technical expertise. This study evaluates a new gradient diffusion method for antimicrobial susceptibility testing of imipenem-relebactam against Pseudomonas aeruginosa . The findings support the use of imipenem-relebactam gradient diffusion as an accurate and reproducible method of antimicrobial susceptibility testing against Pseudomonas aeruginosa .
- 9 November 2026
- Published by American Society for Microbiology in Microbiology Spectrum
Open AccessA multicenter performance evaluation of imipenem-relebactam gradient diffusion susceptibility testing for Pseudomonas aeruginosa
Imipenem-relebactam (I/R) is a beta-lactam/beta-lactamase inhibitor combination given with cilastatin that is indicated for the treatment of complicated urinary tract infections, including pyelonephritis and complicated intra-abdominal infections in patients. Recently, a new gradient diffusion method for antimicrobial susceptibility testing of this antibiotic was developed for Pseudomonas aeruginosa (ETEST IRPA) as an alternative to broth microdilution (BMD). Our objective was to evaluate the performance of the I/R ETEST in comparison to BMD across three external and one internal study sites for 437 (77 challenge, 360 clinical) P. aeruginosa isolates. Using the U.S. Food and Drug Administration (FDA) interpretive breakpoints, ETEST IRPA achieved a 97.7% (427/437) essential agreement (EA), 91.1% (398/437) categorical agreement (CA), 0% very major errors (VMEs), 0.9% (3/329) major errors (MEs), and 8.2% (36/437) minor errors (mEs). Using the European Committee on Antimicrobial Susceptibility Testing (EUCAST) interpretive breakpoints, ETEST IRPA achieved a 97.7% (427/437) EA, 93.8% (410/437) CA, 12% (13/108) VME, and 4.2% (14/329) ME. Both bias and trending were in alignment with regulatory requirements. Reproducibility testing on 10 strains showed 99.6% (269/270) of results were within ±1 doubling dilution of the modal minimum inhibitory concentration (MIC). MIC 50 and MIC 90 values for imipenem were 8 and 32, respectively, in comparison to 1 and 8 with the addition of relebactam as determined by ETEST. In conclusion, ETEST IRPA provides both accurate and reproducible results for performing antimicrobial susceptibility testing of P. aeruginosa when interpreted with both FDA and EUCAST criteria. IMPORTANCE: Antimicrobial susceptibility testing is key to proper treatment of bacterial infections. Broth microdilution is the gold standard for antimicrobial susceptibility testing; however, it can be time-consuming and requires high levels of technical expertise. This study evaluates a new gradient diffusion method for antimicrobial susceptibility testing of imipenem-relebactam against Pseudomonas aeruginosa . The findings support the use of imipenem-relebactam gradient diffusion as an accurate and reproducible method of antimicrobial susceptibility testing against Pseudomonas aeruginosa .
- Open Access
- 13 May 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (5) , e0174925
A multicenter performance evaluation of aztreonam-avibactam gradient diffusion susceptibility testing for Enterobacterales
Aztreonam-avibactam (AZA) is a new monobactam/beta-lactamase inhibitor combination that recently received regulatory approval in the United States (U.S.) and Europe. In this study, we evaluated the performance of ETEST AZA, a gradient diffusion method, compared to reference broth microdilution for 650 challenge ( n = 77) and clinical ( n = 573) Enterobacterales isolates across four study sites. Using the U.S. Food and Drug Administration (FDA) interpretive breakpoints for ETEST AZA, challenge isolates demonstrated a 97.3% (72/74) essential agreement (EA), 93.2% (69/74) categorical agreement (CA), 0% very major errors (VME) and major errors (ME), and 6.8% (5/74) minor errors (mE). Clinical isolates demonstrated a 95.5% (504/528) EA, 98.7% (521/528) CA, 0% VME, 0.2% (1/516) ME, and 1.1% (6/528) mE. Overall, the combined set achieved a 95.7% (576/602) EA and 98.0% (590/602) CA, with 0% VME, 0.2% (1/577) ME, and 1.8% (11/602) mE. Using the European Committee on Antimicrobial Susceptibility Testing (EUCAST) interpretive breakpoints, challenge isolates demonstrated a 96.1% (74/77) EA, 93.5% (72/77) CA, and 31.3% (5/16) VMEs, while clinical isolates demonstrated a 94.1% (539/573) EA and 99.7% (571/573) CA including 7.7% (1/13) VME and 0.2% (1/560) ME. The combined set demonstrated a 94.3% (613/650) EA, 98.9% (643/650) CA, 0.2% (1/573) MEs, but 20.7% (6/21) VMEs due to the lack of an intermediate breakpoint that is addressed as a limitation in the European package insert. Both bias and trending were in alignment with regulatory requirements. In reproducibility testing of 10 on-scale strains, 100% (270/270) of the results were within ±1 doubling dilution of the modal minimal inhibitory concentration. In conclusion, ETEST AZA provides accurate, reproducible susceptibility results that meet regulatory requirements for many Enterobacterales species when interpreted using FDA or EUCAST criteria. IMPORTANCE: Aztreonam-avibactam (AZA) is a novel monobactam/β-lactamase inhibitor combination approved for clinical use in the United States and Europe in 2025 and 2024, respectively. It is indicated for the treatment of multidrug-resistant Gram-negative bacteria that produce multiple classes of β-lactamases. Until recently, antimicrobial susceptibility testing for this combined agent relied on broth disk elution or microdilution using ceftazidime–avibactam and aztreonam combined. In this study, we evaluated the performance of the bioMérieux ETEST AZA gradient diffusion strip as a more streamlined method for clinical microbiology laboratories. Testing of 650 Enterobacterales isolates demonstrated that ETEST AZA met regulatory performance criteria using interpretive breakpoints from both the FDA and the European Committee on Antimicrobial Susceptibility Testing. Overall, our findings indicate that the ETEST AZA demonstrates acceptable performance for many Enterobacterales isolates and represents a practical alternative for implementing AZA susceptibility testing in clinical microbiology laboratories.
- 13 May 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (5) , e0174925
Open AccessA multicenter performance evaluation of aztreonam-avibactam gradient diffusion susceptibility testing for Enterobacterales
Aztreonam-avibactam (AZA) is a new monobactam/beta-lactamase inhibitor combination that recently received regulatory approval in the United States (U.S.) and Europe. In this study, we evaluated the performance of ETEST AZA, a gradient diffusion method, compared to reference broth microdilution for 650 challenge ( n = 77) and clinical ( n = 573) Enterobacterales isolates across four study sites. Using the U.S. Food and Drug Administration (FDA) interpretive breakpoints for ETEST AZA, challenge isolates demonstrated a 97.3% (72/74) essential agreement (EA), 93.2% (69/74) categorical agreement (CA), 0% very major errors (VME) and major errors (ME), and 6.8% (5/74) minor errors (mE). Clinical isolates demonstrated a 95.5% (504/528) EA, 98.7% (521/528) CA, 0% VME, 0.2% (1/516) ME, and 1.1% (6/528) mE. Overall, the combined set achieved a 95.7% (576/602) EA and 98.0% (590/602) CA, with 0% VME, 0.2% (1/577) ME, and 1.8% (11/602) mE. Using the European Committee on Antimicrobial Susceptibility Testing (EUCAST) interpretive breakpoints, challenge isolates demonstrated a 96.1% (74/77) EA, 93.5% (72/77) CA, and 31.3% (5/16) VMEs, while clinical isolates demonstrated a 94.1% (539/573) EA and 99.7% (571/573) CA including 7.7% (1/13) VME and 0.2% (1/560) ME. The combined set demonstrated a 94.3% (613/650) EA, 98.9% (643/650) CA, 0.2% (1/573) MEs, but 20.7% (6/21) VMEs due to the lack of an intermediate breakpoint that is addressed as a limitation in the European package insert. Both bias and trending were in alignment with regulatory requirements. In reproducibility testing of 10 on-scale strains, 100% (270/270) of the results were within ±1 doubling dilution of the modal minimal inhibitory concentration. In conclusion, ETEST AZA provides accurate, reproducible susceptibility results that meet regulatory requirements for many Enterobacterales species when interpreted using FDA or EUCAST criteria. IMPORTANCE: Aztreonam-avibactam (AZA) is a novel monobactam/β-lactamase inhibitor combination approved for clinical use in the United States and Europe in 2025 and 2024, respectively. It is indicated for the treatment of multidrug-resistant Gram-negative bacteria that produce multiple classes of β-lactamases. Until recently, antimicrobial susceptibility testing for this combined agent relied on broth disk elution or microdilution using ceftazidime–avibactam and aztreonam combined. In this study, we evaluated the performance of the bioMérieux ETEST AZA gradient diffusion strip as a more streamlined method for clinical microbiology laboratories. Testing of 650 Enterobacterales isolates demonstrated that ETEST AZA met regulatory performance criteria using interpretive breakpoints from both the FDA and the European Committee on Antimicrobial Susceptibility Testing. Overall, our findings indicate that the ETEST AZA demonstrates acceptable performance for many Enterobacterales isolates and represents a practical alternative for implementing AZA susceptibility testing in clinical microbiology laboratories.
- 21 November 2025
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 45 (3) , 787-796
Recovery of nontuberculous mycobacteria from non-cystic fibrosis respiratory specimens using a decontamination-free selective agar
Digestion and decontamination during acid-fast bacilli (AFB) culture processing are performed to suppress growth of normal microbiota in respiratory specimens; however, these steps may render AFB nonviable. This study aimed to evaluate the performance of NTM Elite agar, a decontamination-free selective medium, for the recovery of nontuberculous mycobacteria (NTM) compared to standard of care (SOC) processing and solid and liquid media inoculation for AFB culture in five hundred lower respiratory samples from non-cystic fibrosis patients. Concurrently, the same specimens were directly inoculated onto NTM Elite agar (NTM Elite-Direct Inoculation) or centrifuged and washed with saline prior to inoculation onto NTM Elite agar (NTM Elite-Concentrated) and incubated up to 28 days. The overall median time to positivity was 7.0 days (IQR = 7–18) for NTM Elite-Direct Inoculation and 14 days (IQR = 7–14) for NTM Elite-Concentrated, which were similar to SOC broth but shorter than SOC solid agar at 35 days (IQR = 2–41). Breakthrough non-AFB growth rate was 1.4% (7/500) NTM Elite-Direct Inoculation, which was less than NTM Elite-Concentrated at 9.0% (45/500) and SOC media at 10.0% (50/500). Forty-five unique isolates were included in the analysis for sensitivity of NTM detection. Sensitivity was 43.5% (95% CI = 30.2–57.8) for SOC media, 20.0% (95% CI = 10.9–33.8) for NTM Elite-Direct Inoculation, and 82.6% (95% CI = 69.3–90.9) for NTM Elite-Concentrated. Combined with SOC broth culture, sensitivity was 93.3% (95% CI = 82.1–97.7) for NTM Elite-Concentrated. The high sensitivity of the latter procedure indicates potential for NTM Elite agar to replace SOC solid agar for detection of NTM in areas of high NTM incidence but low incidence of tuberculosis.
- 21 November 2025
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 45 (3) , 787-796
Recovery of nontuberculous mycobacteria from non-cystic fibrosis respiratory specimens using a decontamination-free selective agar
Digestion and decontamination during acid-fast bacilli (AFB) culture processing are performed to suppress growth of normal microbiota in respiratory specimens; however, these steps may render AFB nonviable. This study aimed to evaluate the performance of NTM Elite agar, a decontamination-free selective medium, for the recovery of nontuberculous mycobacteria (NTM) compared to standard of care (SOC) processing and solid and liquid media inoculation for AFB culture in five hundred lower respiratory samples from non-cystic fibrosis patients. Concurrently, the same specimens were directly inoculated onto NTM Elite agar (NTM Elite-Direct Inoculation) or centrifuged and washed with saline prior to inoculation onto NTM Elite agar (NTM Elite-Concentrated) and incubated up to 28 days. The overall median time to positivity was 7.0 days (IQR = 7–18) for NTM Elite-Direct Inoculation and 14 days (IQR = 7–14) for NTM Elite-Concentrated, which were similar to SOC broth but shorter than SOC solid agar at 35 days (IQR = 2–41). Breakthrough non-AFB growth rate was 1.4% (7/500) NTM Elite-Direct Inoculation, which was less than NTM Elite-Concentrated at 9.0% (45/500) and SOC media at 10.0% (50/500). Forty-five unique isolates were included in the analysis for sensitivity of NTM detection. Sensitivity was 43.5% (95% CI = 30.2–57.8) for SOC media, 20.0% (95% CI = 10.9–33.8) for NTM Elite-Direct Inoculation, and 82.6% (95% CI = 69.3–90.9) for NTM Elite-Concentrated. Combined with SOC broth culture, sensitivity was 93.3% (95% CI = 82.1–97.7) for NTM Elite-Concentrated. The high sensitivity of the latter procedure indicates potential for NTM Elite agar to replace SOC solid agar for detection of NTM in areas of high NTM incidence but low incidence of tuberculosis.
- Open Access
- 8 October 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (10) , e0076925
Evaluation of expert rules for carbapenemase class identification in Enterobacterales isolates using the VITEK2 susceptibility testing platform
Prompt identification of enzyme class in carbapenemase-producing carbapenem-resistant Enterobacterales (CP-CRE) has critical implications for informing appropriate patient treatment, infection prevention, and public health. This study evaluates the performance of prototype bioMérieux Advanced Reporting Tool (bioART) expert rules to rapidly identify Klebsiella pneumoniae carbapenemase (KPC), metallo-β-lactamase (MBL), and OXA-48-like carbapenemase enzymes in CP-CRE. The bioART rules are designed for use with routine cards on the VITEK2 automated antimicrobial susceptibility testing (AST) platform. Results provided by the bioART rules should be interpreted in combination with the instrument Advanced Expert System (AES) to comprehensively evaluate phenotypic resistance phenotypes. Two hundred clinical isolates with varied β-lactam resistance profiles were enrolled, with 196 ultimately analyzed, including 115 CP-CREs. The AES alone detected CP-CRE isolates with a sensitivity of 83% and a specificity of 85%. The combined AES and bioART rules detected CP-CRE with a sensitivity of 96% and a specificity of 83%. Prediction of carbapenemase classes by the bioART rules was analyzed for a subset of 158 isolates, including only the species for which the rules have claimed indications. MBL, KPC, and OXA-48-like enzymes were detected with sensitivities of 97%, 76%, and 47%, respectively. Notably, sensitivity was 90% for single OXA-48-like producers, whereas OXA-48-like enzymes in dual New Delhi metallo-β-lactamase (NDM)/OXA-48-like-producing isolates were undetectable using phenotypic susceptibility patterns, and isolates were reported only as producing NDM enzymes. Overall, laboratories incorporating these tools into carbapenemase screening workflows may consider their utility in prompting confirmatory carbapenemase testing, guiding modifications to AST reporting, and/or prompting additional susceptibility testing. IMPORTANCE: Carbapenem-resistant bacteria are a major public health concern due to their ability to spread in healthcare settings and cause infections that are difficult to treat with first-line antibiotics. Identification of the enzyme classes responsible for carbapenem resistance plays a crucial role in ensuring that patients receive effective treatments and controlling the spread of these bacteria. In this study, we evaluated the performance of a new approach to identify carbapenemase enzymes without additional hands-on testing. The method is designed for use with the VITEK2 automated susceptibility testing platform to recognize patterns of resistance to antibiotics and make predictions about the possible resistance mechanisms.
- 8 October 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (10) , e0076925
Open AccessEvaluation of expert rules for carbapenemase class identification in Enterobacterales isolates using the VITEK2 susceptibility testing platform
Prompt identification of enzyme class in carbapenemase-producing carbapenem-resistant Enterobacterales (CP-CRE) has critical implications for informing appropriate patient treatment, infection prevention, and public health. This study evaluates the performance of prototype bioMérieux Advanced Reporting Tool (bioART) expert rules to rapidly identify Klebsiella pneumoniae carbapenemase (KPC), metallo-β-lactamase (MBL), and OXA-48-like carbapenemase enzymes in CP-CRE. The bioART rules are designed for use with routine cards on the VITEK2 automated antimicrobial susceptibility testing (AST) platform. Results provided by the bioART rules should be interpreted in combination with the instrument Advanced Expert System (AES) to comprehensively evaluate phenotypic resistance phenotypes. Two hundred clinical isolates with varied β-lactam resistance profiles were enrolled, with 196 ultimately analyzed, including 115 CP-CREs. The AES alone detected CP-CRE isolates with a sensitivity of 83% and a specificity of 85%. The combined AES and bioART rules detected CP-CRE with a sensitivity of 96% and a specificity of 83%. Prediction of carbapenemase classes by the bioART rules was analyzed for a subset of 158 isolates, including only the species for which the rules have claimed indications. MBL, KPC, and OXA-48-like enzymes were detected with sensitivities of 97%, 76%, and 47%, respectively. Notably, sensitivity was 90% for single OXA-48-like producers, whereas OXA-48-like enzymes in dual New Delhi metallo-β-lactamase (NDM)/OXA-48-like-producing isolates were undetectable using phenotypic susceptibility patterns, and isolates were reported only as producing NDM enzymes. Overall, laboratories incorporating these tools into carbapenemase screening workflows may consider their utility in prompting confirmatory carbapenemase testing, guiding modifications to AST reporting, and/or prompting additional susceptibility testing. IMPORTANCE: Carbapenem-resistant bacteria are a major public health concern due to their ability to spread in healthcare settings and cause infections that are difficult to treat with first-line antibiotics. Identification of the enzyme classes responsible for carbapenem resistance plays a crucial role in ensuring that patients receive effective treatments and controlling the spread of these bacteria. In this study, we evaluated the performance of a new approach to identify carbapenemase enzymes without additional hands-on testing. The method is designed for use with the VITEK2 automated susceptibility testing platform to recognize patterns of resistance to antibiotics and make predictions about the possible resistance mechanisms.
- Open Access
- 20 June 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (8) , e0021125
Performance and workflow comparison of the VITEK MS PRIME and Bruker Biotyper MALDI-TOF MS systems
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid identification of bacteria and yeast in clinical labs. The VITEK MS PRIME (“PRIME”) is the latest MALDI-TOF MS system from bioMérieux. This study evaluated PRIME’s performance and workflow timing against the MALDI Biotyper CA System by Bruker (“Biotyper”). We compared a collection of 154 bacteria and yeast clinical isolates from various specimen types using three methods: Biotyper target with a toothpick, PRIME target with the PICKME nib, and PRIME target with a loop. Positive blood culture isolates were also analyzed using these methods, with high-experience (HEU, n = 300) and low-experience users (LEU, n = 50) after short (6–8 h) and routine (18–24 h) incubation on agar plates. Workflow timing, from sample processing to organism identification, was assessed to identify time savings. PRIME identified 96% (PICKME) and 95% (Loop) of challenge isolates to genus level, compared with Biotyper at 99%. Short incubation of positive blood culture isolates demonstrated similar species-level identification rates across all methods (Biotyper: 84%, PRIME PICKME: 80%, PRIME Loop: 81%), although more repeats were needed compared with routine incubation. No difference in species identification occurred between users for any method at short incubation (89%–91%, HEU, vs 79%–85% LEU). Single-target process times were comparable for all methods (55–59 min), whereas PRIME methods had shorter hands-on times for analysis of multiple targets (Biotyper: 53 min, PRIME PICKME: 39 min, PRIME Loop: 40 min). These findings highlight the comparable performance of the PRIME and Biotyper systems while demonstrating the potential for time savings with PRIME workflows, particularly in high-throughput settings. IMPORTANCE: This study provides a critical evaluation of the new VITEK MS PRIME MALDI-TOF MS system, comparing its performance and workflow efficiency against the Bruker MALDI Biotyper. The study investigates the success rate of isolate identification from short incubation of positive blood cultures, illustrating the utility of this technique for downstream workflows such as faster reporting of results for patient management and isolate identification for interpretation of rapid phenotypic AST. Analysis of different workflows demonstrated areas for potential time savings, particularly in high-throughput settings. These findings highlight the importance of optimizing MALDI-TOF MS workflows in the era of workforce shortages and lab centralization to enhance rapid pathogen identification and improve patient care.
- 20 June 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (8) , e0021125
Open AccessPerformance and workflow comparison of the VITEK MS PRIME and Bruker Biotyper MALDI-TOF MS systems
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid identification of bacteria and yeast in clinical labs. The VITEK MS PRIME (“PRIME”) is the latest MALDI-TOF MS system from bioMérieux. This study evaluated PRIME’s performance and workflow timing against the MALDI Biotyper CA System by Bruker (“Biotyper”). We compared a collection of 154 bacteria and yeast clinical isolates from various specimen types using three methods: Biotyper target with a toothpick, PRIME target with the PICKME nib, and PRIME target with a loop. Positive blood culture isolates were also analyzed using these methods, with high-experience (HEU, n = 300) and low-experience users (LEU, n = 50) after short (6–8 h) and routine (18–24 h) incubation on agar plates. Workflow timing, from sample processing to organism identification, was assessed to identify time savings. PRIME identified 96% (PICKME) and 95% (Loop) of challenge isolates to genus level, compared with Biotyper at 99%. Short incubation of positive blood culture isolates demonstrated similar species-level identification rates across all methods (Biotyper: 84%, PRIME PICKME: 80%, PRIME Loop: 81%), although more repeats were needed compared with routine incubation. No difference in species identification occurred between users for any method at short incubation (89%–91%, HEU, vs 79%–85% LEU). Single-target process times were comparable for all methods (55–59 min), whereas PRIME methods had shorter hands-on times for analysis of multiple targets (Biotyper: 53 min, PRIME PICKME: 39 min, PRIME Loop: 40 min). These findings highlight the comparable performance of the PRIME and Biotyper systems while demonstrating the potential for time savings with PRIME workflows, particularly in high-throughput settings. IMPORTANCE: This study provides a critical evaluation of the new VITEK MS PRIME MALDI-TOF MS system, comparing its performance and workflow efficiency against the Bruker MALDI Biotyper. The study investigates the success rate of isolate identification from short incubation of positive blood cultures, illustrating the utility of this technique for downstream workflows such as faster reporting of results for patient management and isolate identification for interpretation of rapid phenotypic AST. Analysis of different workflows demonstrated areas for potential time savings, particularly in high-throughput settings. These findings highlight the importance of optimizing MALDI-TOF MS workflows in the era of workforce shortages and lab centralization to enhance rapid pathogen identification and improve patient care.
- Open Access
- 27 September 2024
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 11 (10) , ofae617
Effect of Universal Masking on Non–Severe Acute Respiratory Syndrome Coronavirus 2 Healthcare-Associated Respiratory Viral Infections
Respiratory viral infections are common and are a major cause of morbidity and mortality. We evaluated the impact of universal masking implemented during the coronavirus disease 2019 (COVID-19) pandemic on other healthcare-associated respiratory viral infections (HA-RIs) in an academic medical center. A retrospective cohort study was performed among all inpatients aged ≥18 years admitted between 1 May 2019 and 30 June 2022. Universal masking was implemented in May 2020 at our hospital and state-level mask mandates had been lifted by May 2021. We evaluated and compared the HA-RI rates, adjusted for monthly community-onset viral infections, during the premasking period, universal masking period, and post–community mandate period. We identified 3015 patients (median age, 58 years; 48.0% males) with a positive respiratory viral test within 14 days prior to, or during, their hospitalization; 441 (14.6%) patients had an HA-RI. Rhinovirus/enterovirus (51.0%), parainfluenza virus (14.3%), coronaviruses (229E, OC43, HKU1, and NL63; 13.2%) and influenza (10.0%) were the predominant HA-RI viruses detected. The monthly HA-RI rate decreased 34.9% (95% confidence interval, 8.8%–51.8%) after the implementation of universal masking (0.71 premasking period vs 0.19 universal masking period vs 0.35 infections per 1000 patient-days in the post–community mandate period) while accounting for a drop in the community-onset respiratory viral infections using a structural time-series model analysis (P < .001), with no significant change in HA-RI rates with the relaxation of community masking mandate. Implementation of universal masking at our hospital was associated with a significantly reduced incidence of HA-RIs.
- 27 September 2024
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 11 (10) , ofae617
Open AccessEffect of Universal Masking on Non–Severe Acute Respiratory Syndrome Coronavirus 2 Healthcare-Associated Respiratory Viral Infections
Respiratory viral infections are common and are a major cause of morbidity and mortality. We evaluated the impact of universal masking implemented during the coronavirus disease 2019 (COVID-19) pandemic on other healthcare-associated respiratory viral infections (HA-RIs) in an academic medical center. A retrospective cohort study was performed among all inpatients aged ≥18 years admitted between 1 May 2019 and 30 June 2022. Universal masking was implemented in May 2020 at our hospital and state-level mask mandates had been lifted by May 2021. We evaluated and compared the HA-RI rates, adjusted for monthly community-onset viral infections, during the premasking period, universal masking period, and post–community mandate period. We identified 3015 patients (median age, 58 years; 48.0% males) with a positive respiratory viral test within 14 days prior to, or during, their hospitalization; 441 (14.6%) patients had an HA-RI. Rhinovirus/enterovirus (51.0%), parainfluenza virus (14.3%), coronaviruses (229E, OC43, HKU1, and NL63; 13.2%) and influenza (10.0%) were the predominant HA-RI viruses detected. The monthly HA-RI rate decreased 34.9% (95% confidence interval, 8.8%–51.8%) after the implementation of universal masking (0.71 premasking period vs 0.19 universal masking period vs 0.35 infections per 1000 patient-days in the post–community mandate period) while accounting for a drop in the community-onset respiratory viral infections using a structural time-series model analysis (P < .001), with no significant change in HA-RI rates with the relaxation of community masking mandate. Implementation of universal masking at our hospital was associated with a significantly reduced incidence of HA-RIs.
- 5 September 2024
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (11) , 2137-2146
Optimizing recovery of Haemophilus influenzae from vaginal-rectal specimens and determining carriage rates in pregnant women
Purpose Haemophilus influenzae (HINF), primarily non-typeable H. influenzae: (NTHi), is an important cause of neonatal sepsis and meningitis. The goal of this study was to investigate the point prevalence of HINF vaginal-rectal carriage in pregnant women, which could impact neonatal health. Methods Simulated vaginal-rectal swabs were cultured and tested to establish optimal recovery methods for HINF. These methods were then applied to vaginal-rectal swabs from a prospective cohort of pregnant women (n = 300) undergoing routine Group B Streptococcus: (GBS) screening. Both culture and PCR were used for detection of HINF. Subject demographics, reproductive history, and genitourinary test results were documented. A retrospective surveillance study was conducted to determine incidence of invasive neonatal HINF infections from 7/1/2017-6/30/2023. Results HINF was recovered from 42/42 (100%) simulated vaginal-rectal swabs at 2–45 CFU/plate via direct plating onto chocolate and chocolate + bacitracin agar. HINF was rarely recovered following LIM broth enrichment at 0–75 CFU/plate in 1/42 (2.4%) simulated swabs, but was recovered from BHI/Fildes broth enrichment in 22/42 (52%) specimens at high abundance (> 100 CFU/plate). Among pregnant women prospectively screened for HINF, the median age was 29 (IQR, 24–33) years and gestational age was 36 (IQR, 34–36) weeks. HINF was recovered in 1 of 300 prospective specimens by culture but 0/100 by PCR. A six-year retrospective analysis showed there were seven total cases of neonatal sepsis and majority of HINF was isolated from respiratory specimens followed by blood/CSF overall. Conclusion This study established a sensitive culture method for recovering HINF from vaginal-rectal swab specimens and demonstrated low prevalence of HINF carriage rate in pregnant women. These findings highlight the need for further research to pinpoint the source for transmission of HINF to neonates.
- 5 September 2024
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (11) , 2137-2146
Optimizing recovery of Haemophilus influenzae from vaginal-rectal specimens and determining carriage rates in pregnant women
Purpose Haemophilus influenzae (HINF), primarily non-typeable H. influenzae: (NTHi), is an important cause of neonatal sepsis and meningitis. The goal of this study was to investigate the point prevalence of HINF vaginal-rectal carriage in pregnant women, which could impact neonatal health. Methods Simulated vaginal-rectal swabs were cultured and tested to establish optimal recovery methods for HINF. These methods were then applied to vaginal-rectal swabs from a prospective cohort of pregnant women (n = 300) undergoing routine Group B Streptococcus: (GBS) screening. Both culture and PCR were used for detection of HINF. Subject demographics, reproductive history, and genitourinary test results were documented. A retrospective surveillance study was conducted to determine incidence of invasive neonatal HINF infections from 7/1/2017-6/30/2023. Results HINF was recovered from 42/42 (100%) simulated vaginal-rectal swabs at 2–45 CFU/plate via direct plating onto chocolate and chocolate + bacitracin agar. HINF was rarely recovered following LIM broth enrichment at 0–75 CFU/plate in 1/42 (2.4%) simulated swabs, but was recovered from BHI/Fildes broth enrichment in 22/42 (52%) specimens at high abundance (> 100 CFU/plate). Among pregnant women prospectively screened for HINF, the median age was 29 (IQR, 24–33) years and gestational age was 36 (IQR, 34–36) weeks. HINF was recovered in 1 of 300 prospective specimens by culture but 0/100 by PCR. A six-year retrospective analysis showed there were seven total cases of neonatal sepsis and majority of HINF was isolated from respiratory specimens followed by blood/CSF overall. Conclusion This study established a sensitive culture method for recovering HINF from vaginal-rectal swab specimens and demonstrated low prevalence of HINF carriage rate in pregnant women. These findings highlight the need for further research to pinpoint the source for transmission of HINF to neonates.
- 3 June 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 70 (6) , 792-797
Microbiome-Based Diagnostics for Disease: Where Are We Now and Where Are We Headed?
The human microbiome has emerged as a pivotal player in the maintenance of health and disease. Advances in taxonomic profiling and functional classification have revealed the association of microbiome alterations in several disease processes, including inflammatory bowel disease, infection, and cancer. This systematic characterization of the human microbiome has facilitated the development of microbiome-based therapeutics that aim to reengineer the microbial ecosystem. As advancements in sequencing technologies render them more accessible and cost-effective, the potential for diagnostic applications of the microbiome is burgeoning. However, this promising landscape is not without its challenges, ranging from evolving public perception, technical barriers to development and implementation, and lack of coordination among stakeholders in research, clinical, and industry domains. In this Q&A, 4 experts from both research and clinical settings explore the current state of microbiome diagnostics, shedding light on the hurdles and prospects for operationalizing clinical use.
- 3 June 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 70 (6) , 792-797
Microbiome-Based Diagnostics for Disease: Where Are We Now and Where Are We Headed?
The human microbiome has emerged as a pivotal player in the maintenance of health and disease. Advances in taxonomic profiling and functional classification have revealed the association of microbiome alterations in several disease processes, including inflammatory bowel disease, infection, and cancer. This systematic characterization of the human microbiome has facilitated the development of microbiome-based therapeutics that aim to reengineer the microbial ecosystem. As advancements in sequencing technologies render them more accessible and cost-effective, the potential for diagnostic applications of the microbiome is burgeoning. However, this promising landscape is not without its challenges, ranging from evolving public perception, technical barriers to development and implementation, and lack of coordination among stakeholders in research, clinical, and industry domains. In this Q&A, 4 experts from both research and clinical settings explore the current state of microbiome diagnostics, shedding light on the hurdles and prospects for operationalizing clinical use.
- 7 February 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 70 (2) , 460-461
A False-Negative Fungal Antigen Test
- 7 February 2024
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 70 (2) , 460-461
A False-Negative Fungal Antigen Test
- Open Access
- 6 October 2023
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (3) , 384-386
Impact of diagnostic stewardship interventions in the collection process of fungal blood cultures
We implemented 2 interventions to improve utilization and contamination at our institution: kits to improve appropriate sample collection and an electronic order alert displaying appropriate indications of fungal blood cultures. An electronic order alert when ordering fungal blood cultures was associated with decreased utilization without decrease in positivity rate.
- 6 October 2023
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (3) , 384-386
Open AccessImpact of diagnostic stewardship interventions in the collection process of fungal blood cultures
We implemented 2 interventions to improve utilization and contamination at our institution: kits to improve appropriate sample collection and an electronic order alert displaying appropriate indications of fungal blood cultures. An electronic order alert when ordering fungal blood cultures was associated with decreased utilization without decrease in positivity rate.