Francesco Iberite
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesco Iberite has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Silvestro Micera
The Biorobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant’Anna, Pisa, Italy
8 shared publications - Giacomo Valle
Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL, USA
7 shared publications - Ivo Strauss
Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne, Switzerland
7 shared publications - Thomas Stieglitz
Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg
6 shared publications - Marco Controzzi
BioRobotics Institute, Scuola Superiore SantAnna, Pisa, Italy
5 shared publications - Alberto Mazzoni
The Biorobotics Institute, Sant’Anna School of Advanced Studies, Pisa, Italy
4 shared publications
Latest Publications
- 19 May 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 380 (6646) , 731-735
Restoration of natural thermal sensation in upper-limb amputees
The use of hands for gathering rich sensory information is essential for proper interaction with the environment; therefore, the restoration of sensation is critical for reestablishing the sense of embodiment in hand amputees. Here, we show that a noninvasive wearable device can be used to provide thermal sensations on amputees’ phantom hands. The device delivers thermal stimuli to specific regions of skin on their residual limb. These sensations were phenomenologically similar to those on the intact limbs and were stable over time. Using the device, the subjects could successfully exploit the thermal phantom hand maps to detect and discriminate different thermal stimuli. The use of a wearable device that provides thermal sensation can increase the sense of embodiment and improve life quality in hand amputees.
- 19 May 2023
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 380 (6646) , 731-735
Restoration of natural thermal sensation in upper-limb amputees
The use of hands for gathering rich sensory information is essential for proper interaction with the environment; therefore, the restoration of sensation is critical for reestablishing the sense of embodiment in hand amputees. Here, we show that a noninvasive wearable device can be used to provide thermal sensations on amputees’ phantom hands. The device delivers thermal stimuli to specific regions of skin on their residual limb. These sensations were phenomenologically similar to those on the intact limbs and were stable over time. Using the device, the subjects could successfully exploit the thermal phantom hand maps to detect and discriminate different thermal stimuli. The use of a wearable device that provides thermal sensation can increase the sense of embodiment and improve life quality in hand amputees.
- 1 April 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (2) , 026038
Early decoding of walking tasks with minimal set of EMG channels
Objective. Powered lower-limb prostheses relying on decoding motor intentions from non-invasive sensors, like electromyographic (EMG) signals, can significantly improve the quality of life of amputee subjects. However, the optimal combination of high decoding performance and minimal set-up burden is yet to be determined. Here we propose an efficient decoding approach obtaining high decoding performance by observing only a fraction of the gait duration with a limited number of recording sites. Approach. Thirteen transfemoral amputee subjects performed five motor tasks while recording EMG signals from four muscles and inertial signals from the prosthesis. A support-vector-machine-based algorithm decoded the gait modality selected by the patient from a finite set. We investigated the trade-off between the robustness of the classifier’s accuracy and the minimization of (i) the duration of the observation window, (ii) the number of EMG recording sites, (iii) the computational load of the procedure, measured the complexity of the algorithm. Main results. When including pre-foot-strike data in the decoding, the combination of three EMG recording sites and the inertial signals led to correct rates above 94% at the 20% of the gait cycle, showing the best trade-off between invasiveness of the setup and accuracy of the classifier. The complexity of the algorithm proved to be significantly higher when applying a polynomial kernel compared to a linear one, while the correct rate of the classifier generally showed no differences between the two approaches. The proposed algorithm led to high performance with a minimal EMG set-up and using only a fraction of the gait duration. Significance. These results pave the way for efficient control of powered lower-limb prostheses with minimal set-up burden and a rapid classification output.
- 1 April 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (2) , 026038
Early decoding of walking tasks with minimal set of EMG channels
Objective. Powered lower-limb prostheses relying on decoding motor intentions from non-invasive sensors, like electromyographic (EMG) signals, can significantly improve the quality of life of amputee subjects. However, the optimal combination of high decoding performance and minimal set-up burden is yet to be determined. Here we propose an efficient decoding approach obtaining high decoding performance by observing only a fraction of the gait duration with a limited number of recording sites. Approach. Thirteen transfemoral amputee subjects performed five motor tasks while recording EMG signals from four muscles and inertial signals from the prosthesis. A support-vector-machine-based algorithm decoded the gait modality selected by the patient from a finite set. We investigated the trade-off between the robustness of the classifier’s accuracy and the minimization of (i) the duration of the observation window, (ii) the number of EMG recording sites, (iii) the computational load of the procedure, measured the complexity of the algorithm. Main results. When including pre-foot-strike data in the decoding, the combination of three EMG recording sites and the inertial signals led to correct rates above 94% at the 20% of the gait cycle, showing the best trade-off between invasiveness of the setup and accuracy of the classifier. The complexity of the algorithm proved to be significantly higher when applying a polynomial kernel compared to a linear one, while the correct rate of the classifier generally showed no differences between the two approaches. The proposed algorithm led to high performance with a minimal EMG set-up and using only a fraction of the gait duration. Significance. These results pave the way for efficient control of powered lower-limb prostheses with minimal set-up burden and a rapid classification output.
- 26 December 2022
- Published by Wiley in Small Methods
- Vol. 7 (8) , e2201318
Wearable High‐Density MXene‐Bioelectronics for Neuromuscular Diagnostics, Rehabilitation, and Assistive Technologies
High‐density surface electromyography (HDsEMG) allows noninvasive muscle monitoring and disease diagnosis. Clinical translation of current HDsEMG technologies is hampered by cost, limited scalability, low usability, and minimal spatial coverage. Here, this study presents, validates, and demonstrates the broad clinical applicability of dry wearable MXene HDsEMG arrays (MXtrodes) fabricated from safe and scalable liquid‐phase processing of Ti3C2Tx. The fabrication scheme allows easy customization of array geometry to match subject anatomy, while the gel‐free and minimal skin preparation enhance usability and comfort. The low impedance and high conductivity of the MXtrode arrays allow detection of the activity of large muscle groups at higher quality and spatial resolution than state‐of‐the‐art wireless electromyography sensors, and in realistic clinical scenarios. To demonstrate the clinical applicability of MXtrodes in the context of neuromuscular diagnostics and rehabilitation, simultaneous HDsEMG and biomechanical mapping of muscle groups across the whole calf during various tasks, ranging from controlled contractions to walking is shown. Finally, the integration of HDsEMG acquired with MXtrodes with a machine learning pipeline and the accurate prediction of the phases of human gait are shown. The results underscore the advantages and translatability of MXene‐based wearable bioelectronics for studying neuromuscular function and disease, as well as for precision rehabilitation.
- 26 December 2022
- Published by Wiley in Small Methods
- Vol. 7 (8) , e2201318
Wearable High‐Density MXene‐Bioelectronics for Neuromuscular Diagnostics, Rehabilitation, and Assistive Technologies
High‐density surface electromyography (HDsEMG) allows noninvasive muscle monitoring and disease diagnosis. Clinical translation of current HDsEMG technologies is hampered by cost, limited scalability, low usability, and minimal spatial coverage. Here, this study presents, validates, and demonstrates the broad clinical applicability of dry wearable MXene HDsEMG arrays (MXtrodes) fabricated from safe and scalable liquid‐phase processing of Ti3C2Tx. The fabrication scheme allows easy customization of array geometry to match subject anatomy, while the gel‐free and minimal skin preparation enhance usability and comfort. The low impedance and high conductivity of the MXtrode arrays allow detection of the activity of large muscle groups at higher quality and spatial resolution than state‐of‐the‐art wireless electromyography sensors, and in realistic clinical scenarios. To demonstrate the clinical applicability of MXtrodes in the context of neuromuscular diagnostics and rehabilitation, simultaneous HDsEMG and biomechanical mapping of muscle groups across the whole calf during various tasks, ranging from controlled contractions to walking is shown. Finally, the integration of HDsEMG acquired with MXtrodes with a machine learning pipeline and the accurate prediction of the phases of human gait are shown. The results underscore the advantages and translatability of MXene‐based wearable bioelectronics for studying neuromuscular function and disease, as well as for precision rehabilitation.
- 1 October 2020
- Published by Elsevier in Clinical Neurophysiology
- Vol. 131 (10) , 2341-2348
Cortical plasticity after hand prostheses use: Is the hypothesis of deafferented cortex “invasion” always true?
- 1 October 2020
- Published by Elsevier in Clinical Neurophysiology
- Vol. 131 (10) , 2341-2348
Cortical plasticity after hand prostheses use: Is the hypothesis of deafferented cortex “invasion” always true?
- Open Access
- 19 September 2020
- Published by Wiley in Brain and Behavior
- Vol. 10 (11)
Brain reactions to the use of sensorized hand prosthesis in amputees
Objective: We investigated for the first time the presence of chronic changes in the functional organization of sensorimotor brain areas induced by prolonged training with a bidirectional hand prosthesis.Methods: A multimodal neurophysiological and neuroimaging evaluation of brain functional changes occurring during training in five consecutive amputees participating to experimental trials with robotic hands over a period of 10 years was carried out. In particular, modifications to the functional anatomy of sensorimotor brain areas under resting conditions were explored in order to check for eventual changes with respect to baseline.Results: Full evidence is provided to demonstrate brain functional changes, and some of them in both the hemispheres and others restricted to the hemisphere contralateral to the amputation/prosthetic hand.Conclusions: The study describes a unique experimental experience showing that brain reactions to the prolonged use of an artificial hand can be tracked for a tailored approach to a fully embedded artificial upper limb for future chronic uses in daily activities.
- 19 September 2020
- Published by Wiley in Brain and Behavior
- Vol. 10 (11)
Open AccessBrain reactions to the use of sensorized hand prosthesis in amputees
Objective: We investigated for the first time the presence of chronic changes in the functional organization of sensorimotor brain areas induced by prolonged training with a bidirectional hand prosthesis.Methods: A multimodal neurophysiological and neuroimaging evaluation of brain functional changes occurring during training in five consecutive amputees participating to experimental trials with robotic hands over a period of 10 years was carried out. In particular, modifications to the functional anatomy of sensorimotor brain areas under resting conditions were explored in order to check for eventual changes with respect to baseline.Results: Full evidence is provided to demonstrate brain functional changes, and some of them in both the hemispheres and others restricted to the hemisphere contralateral to the amputation/prosthetic hand.Conclusions: The study describes a unique experimental experience showing that brain reactions to the prolonged use of an artificial hand can be tracked for a tailored approach to a fully embedded artificial upper limb for future chronic uses in daily activities.
- Open Access
- 27 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7916
Optimal integration of intraneural somatosensory feedback with visual information: a single-case study
Providing somatosensory feedback to amputees is a long-standing objective in prosthesis research. Recently, implantable neural interfaces have yielded promising results in this direction. There is now considerable evidence that the nervous system integrates redundant signals optimally, weighting each signal according to its reliability. One question of interest is whether artificial sensory feedback is combined with other sensory information in a natural manner. In this single-case study, we show that an amputee with a bidirectional prosthesis integrated artificial somatosensory feedback and blurred visual information in a statistically optimal fashion when estimating the size of a hand-held object. The patient controlled the opening and closing of the prosthetic hand through surface electromyography, and received intraneural stimulation proportional to the object’s size in the ulnar nerve when closing the robotic hand on the object. The intraneural stimulation elicited a vibration sensation in the phantom hand that substituted the missing haptic feedback. This result indicates that sensory substitution based on intraneural feedback can be integrated with visual feedback and make way for a promising method to investigate multimodal integration processes.
- 27 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7916
Open AccessOptimal integration of intraneural somatosensory feedback with visual information: a single-case study
Providing somatosensory feedback to amputees is a long-standing objective in prosthesis research. Recently, implantable neural interfaces have yielded promising results in this direction. There is now considerable evidence that the nervous system integrates redundant signals optimally, weighting each signal according to its reliability. One question of interest is whether artificial sensory feedback is combined with other sensory information in a natural manner. In this single-case study, we show that an amputee with a bidirectional prosthesis integrated artificial somatosensory feedback and blurred visual information in a statistically optimal fashion when estimating the size of a hand-held object. The patient controlled the opening and closing of the prosthetic hand through surface electromyography, and received intraneural stimulation proportional to the object’s size in the ulnar nerve when closing the robotic hand on the object. The intraneural stimulation elicited a vibration sensation in the phantom hand that substituted the missing haptic feedback. This result indicates that sensory substitution based on intraneural feedback can be integrated with visual feedback and make way for a promising method to investigate multimodal integration processes.
- 27 February 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 026034
Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand
Objective . Tactile afferents in the human hand provide fundamental information about hand-environment interactions, which is used by the brain to adapt the motor output to the physical properties of the object being manipulated. A hand amputation disrupts both afferent and efferent pathways from/to the hand, completely invalidating the individual’s motor repertoire. Although motor functions may be partially recovered by using a myoelectric prosthesis, providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. While past studies using invasive stimulation suggested that sensory feedback may help in handling fragile objects, none explored the underpinning, relearned, motor coordination during grasping. In this study, we aimed at showing for the first time that intraneural sensory feedback of the grip force (GF) improves the sensorimotor control of a transradial amputee controlling a myoelectric prosthesis. Approach . We performed a longitudinal study testing a single subject (clinical trial registration number NCT02848846). A stacking cups test (CUP) performed over two weeks aimed at measuring the subject’s ability to finely regulate the GF applied with the prosthesis. A pick and lift test (PLT), performed at the end of the study, measured the level of motor coordination, and whether the subject transferred the motor skills learned in the CUP to an alien task. Main results . The results show that intraneural sensory feedback increases the subject’s ability in regulating the GF and allows for improved performance over time. Additionally, the PLT demonstrated that the subject was able to generalize and transfer her manipulation skills to an unknown task and to improve her motor coordination. Significance . Our findings suggest that intraneural sensory feedback holds the potential of restoring functionally effective tactile feedback. This opens up new possibilities to improve the quality of life of amputees using a neural prosthesis.
- 27 February 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 026034
Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand
Objective . Tactile afferents in the human hand provide fundamental information about hand-environment interactions, which is used by the brain to adapt the motor output to the physical properties of the object being manipulated. A hand amputation disrupts both afferent and efferent pathways from/to the hand, completely invalidating the individual’s motor repertoire. Although motor functions may be partially recovered by using a myoelectric prosthesis, providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. While past studies using invasive stimulation suggested that sensory feedback may help in handling fragile objects, none explored the underpinning, relearned, motor coordination during grasping. In this study, we aimed at showing for the first time that intraneural sensory feedback of the grip force (GF) improves the sensorimotor control of a transradial amputee controlling a myoelectric prosthesis. Approach . We performed a longitudinal study testing a single subject (clinical trial registration number NCT02848846). A stacking cups test (CUP) performed over two weeks aimed at measuring the subject’s ability to finely regulate the GF applied with the prosthesis. A pick and lift test (PLT), performed at the end of the study, measured the level of motor coordination, and whether the subject transferred the motor skills learned in the CUP to an alien task. Main results . The results show that intraneural sensory feedback increases the subject’s ability in regulating the GF and allows for improved performance over time. Additionally, the PLT demonstrated that the subject was able to generalize and transfer her manipulation skills to an unknown task and to improve her motor coordination. Significance . Our findings suggest that intraneural sensory feedback holds the potential of restoring functionally effective tactile feedback. This opens up new possibilities to improve the quality of life of amputees using a neural prosthesis.
- Top Cited Papers
- 20 February 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 4 (27)
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
Bionic hand provides accurate tactile and position information and leads to improved performance during sensing tasks.
- 20 February 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 4 (27)
Top Cited PapersA closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
Bionic hand provides accurate tactile and position information and leads to improved performance during sensing tasks.
- Open Access
- 12 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-13
Comparison of linear frequency and amplitude modulation for intraneural sensory feedback in bidirectional hand prostheses
Recent studies have shown that direct nerve stimulation can be used to provide sensory feedback to hand amputees. The intensity of the elicited sensations can be modulated using the amplitude or frequency of the injected stimuli. However, a comprehensive comparison of the effects of these two encoding strategies on the amputees’ ability to control a prosthesis has not been performed. In this paper, we assessed the performance of two trans-radial amputees controlling a myoelectric hand prosthesis while receiving grip force sensory feedback encoded using either linear modulation of amplitude (LAM) or linear modulation of frequency (LFM) of direct nerve stimulation (namely, bidirectional prostheses). Both subjects achieved similar and significantly above-chance performance when they were asked to exploit LAM or LFM in different tasks. The feedbacks allowed them to discriminate, during manipulation through the robotic hand, objects of different compliances and shapes or different placements on the prosthesis. Similar high performances were obtained when they were asked to apply different levels of force in a random order on a dynamometer using LAM or LFM. In contrast, only the LAM strategy allowed the subjects to continuously modulate the grip pressure on the dynamometer. Furthermore, when long-lasting trains of stimulation were delivered, LFM strategy generated a very fast adaptation phenomenon in the subjects, which caused them to stop perceiving the restored sensations. Both encoding approaches were perceived as very different from the touch feelings of the healthy limb (natural). These results suggest that the choice of specific sensory feedback encodings can have an effect on user performance while grasping. In addition, our results invite the development of new approaches to provide more natural sensory feelings to the users, which could be addressed by a more biomimetic strategy in the future.
- 12 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-13
Open AccessComparison of linear frequency and amplitude modulation for intraneural sensory feedback in bidirectional hand prostheses
Recent studies have shown that direct nerve stimulation can be used to provide sensory feedback to hand amputees. The intensity of the elicited sensations can be modulated using the amplitude or frequency of the injected stimuli. However, a comprehensive comparison of the effects of these two encoding strategies on the amputees’ ability to control a prosthesis has not been performed. In this paper, we assessed the performance of two trans-radial amputees controlling a myoelectric hand prosthesis while receiving grip force sensory feedback encoded using either linear modulation of amplitude (LAM) or linear modulation of frequency (LFM) of direct nerve stimulation (namely, bidirectional prostheses). Both subjects achieved similar and significantly above-chance performance when they were asked to exploit LAM or LFM in different tasks. The feedbacks allowed them to discriminate, during manipulation through the robotic hand, objects of different compliances and shapes or different placements on the prosthesis. Similar high performances were obtained when they were asked to apply different levels of force in a random order on a dynamometer using LAM or LFM. In contrast, only the LAM strategy allowed the subjects to continuously modulate the grip pressure on the dynamometer. Furthermore, when long-lasting trains of stimulation were delivered, LFM strategy generated a very fast adaptation phenomenon in the subjects, which caused them to stop perceiving the restored sensations. Both encoding approaches were perceived as very different from the touch feelings of the healthy limb (natural). These results suggest that the choice of specific sensory feedback encodings can have an effect on user performance while grasping. In addition, our results invite the development of new approaches to provide more natural sensory feelings to the users, which could be addressed by a more biomimetic strategy in the future.
- Top Cited Papers
Biomimetic Intraneural Sensory Feedback Enhances Sensation Naturalness, Tactile Sensitivity, and Manual Dexterity in a Bidirectional Prosthesis