Nathan W. Levin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nathan W. Levin has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Allen M. Kaufman
Dialyze Direct, Brooklyn, NY, USA
1 shared publication - Brett Larive
Cleveland Clinic Foundation, Cleveland, OH, USA
1 shared publication Caroline Williams
Queens Artificial Kidney Center, New York, NY, USA and
1 shared publication- David Pereg
Department of Cardiology, Meir Medical Center, Kfar Saba, Israel
1 shared publication - Feng Yunlin
Renal Division, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China
1 shared publication - Garry Handelman
University of Massachusetts Lowell, Lowell, MA, USA
1 shared publication
Latest Publications
- Open Access
- 3 September 2019
- Published by Springer Nature in BMC Nephrology
- Vol. 20 (1) , 1-8
Non-invasive hemodynamic profiling of patients undergoing hemodialysis - a multicenter observational cohort study
Intradialytic blood pressure (BP) measurement is currently the main parameter used for monitoring hemodynamics during hemodialysis (HD). Since BP is dependent on cardiac output and total peripheral resistance, knowledge of these parameters throughout the HD treatment would potentially be valuable. The use of a novel non-invasive monitoring system for profiling hemodynamic response patterns during HD was explored: a whole-body bio-impedance system was used to assess cardiac index (CI), total peripheral resistance index (TPRI), cardiac power index (CPI) among other parameters in chronic HD patients from 4 medical centers. Measurements were made pre, during and post dialysis. Patients were grouped into 5 hemodynamic profiles based on their main hemodynamic response during dialysis i.e. high TPRI; high CPI; low CPI; low TPRI and those with normal hemodynamics. Comparisons were made between the groups for baseline characteristics and 1-year mortality. In 144 patients with mean age of 67.3 ± 12.1 years pre-dialysis hemodynamic measurements were within normal limits in 35.4% but only 6.9% overall remained hemodynamically stable during dialysis. Intradialytic BP decreased in 65 (45.1%) in whom, low CPI (47 (72.3%)) and low TPRI (18 (27.7%) were recorded. At 1-year follow-up, mortality rates were highest in patients with low CPI (23.4%) and low TPRI (22.2%). Non-invasive assessment of patients’ response to HD provides relevant hemodynamic information that exceeds that provided by currently used BP measurements. Use of these online analyses could potentially improve the safety and performance standards of dialysis by guiding appropriate interventions, particularly in responding to hypertension and hypotension.
- 3 September 2019
- Published by Springer Nature in BMC Nephrology
- Vol. 20 (1) , 1-8
Open AccessNon-invasive hemodynamic profiling of patients undergoing hemodialysis - a multicenter observational cohort study
Intradialytic blood pressure (BP) measurement is currently the main parameter used for monitoring hemodynamics during hemodialysis (HD). Since BP is dependent on cardiac output and total peripheral resistance, knowledge of these parameters throughout the HD treatment would potentially be valuable. The use of a novel non-invasive monitoring system for profiling hemodynamic response patterns during HD was explored: a whole-body bio-impedance system was used to assess cardiac index (CI), total peripheral resistance index (TPRI), cardiac power index (CPI) among other parameters in chronic HD patients from 4 medical centers. Measurements were made pre, during and post dialysis. Patients were grouped into 5 hemodynamic profiles based on their main hemodynamic response during dialysis i.e. high TPRI; high CPI; low CPI; low TPRI and those with normal hemodynamics. Comparisons were made between the groups for baseline characteristics and 1-year mortality. In 144 patients with mean age of 67.3 ± 12.1 years pre-dialysis hemodynamic measurements were within normal limits in 35.4% but only 6.9% overall remained hemodynamically stable during dialysis. Intradialytic BP decreased in 65 (45.1%) in whom, low CPI (47 (72.3%)) and low TPRI (18 (27.7%) were recorded. At 1-year follow-up, mortality rates were highest in patients with low CPI (23.4%) and low TPRI (22.2%). Non-invasive assessment of patients’ response to HD provides relevant hemodynamic information that exceeds that provided by currently used BP measurements. Use of these online analyses could potentially improve the safety and performance standards of dialysis by guiding appropriate interventions, particularly in responding to hypertension and hypotension.
- Open Access
- 17 May 2019
- Published by Springer Nature in BMC Nephrology
- Vol. 20 (1) , 1-11
The effect of increased frequency of hemodialysis on vitamin C concentrations: an ancillary study of the randomized Frequent Hemodialysis Network (FHN) daily trial
Reports on vitamin C in HD patients have shown effects of vitamin C deficiency in association with scurvy symptoms. Dialyzability of water soluble vitamins is high, and substantial losses in those who are dialyzed more frequently were hypothesized. The randomized FHN Daily Trial compared the effects of in-center HD six versus three times per week. We studied baseline correlations between vitamin C and potentially associated parameters, and the effect of more frequent HD on circulating vitamin C concentrations. We studied vitamin C levels at baseline and months, 3, 5 and 11. Patients enrolled between 2007 and 2009 into the randomized FHN Daily trial in the East Coast consortium were approached for participation. Predialysis plasma samples were processed with metaphosphoric acid and frozen at − 70 °C for measurement with HPLC. Regression models between baseline log-transformed vitamin C and hemoglobin, CRP, eKt/V, ePCR and PTH, and a linear mixed-effects model to estimate the effect size of more frequent HD on plasma vitamin C, were constructed. We studied 44 subjects enrolled in the FHN Daily trial (50 ± 12 years, 36% female, 29% Hispanics and 64% blacks, 60% anuric). Vitamin C correlated significantly with predialysis hemoglobin (r = 0.3; P = 0.03) and PTH (r = − 0.3, P = 0.04), respectively. Vitamin C did not significantly differ at baseline (6×/week, 25.8 ± 25.9 versus 3×/week, 32.6 ± 39.4 μmol/L) and no significant treatment effect on plasma vitamin C concentrations was found [− 26.2 (95%CI -57.5 to 5.1) μmol/L at Month 4 and − 2.5 (95%CI -15.6 to 10.6) μmol/L at Month 12. Based on data from this large randomized-controlled trial no significant effect of the intervention on circulating plasma vitamin C concentrations was found, allaying the concerns that more frequent HD would affect the concentrations of water-soluble vitamins and adversely affect patient’s well-being. Correlations between vitamin C and hemoglobin and PTH support the importance of vitamin C for normal bone and mineral metabolism, and anemia management.
- 17 May 2019
- Published by Springer Nature in BMC Nephrology
- Vol. 20 (1) , 1-11
Open AccessThe effect of increased frequency of hemodialysis on vitamin C concentrations: an ancillary study of the randomized Frequent Hemodialysis Network (FHN) daily trial
Reports on vitamin C in HD patients have shown effects of vitamin C deficiency in association with scurvy symptoms. Dialyzability of water soluble vitamins is high, and substantial losses in those who are dialyzed more frequently were hypothesized. The randomized FHN Daily Trial compared the effects of in-center HD six versus three times per week. We studied baseline correlations between vitamin C and potentially associated parameters, and the effect of more frequent HD on circulating vitamin C concentrations. We studied vitamin C levels at baseline and months, 3, 5 and 11. Patients enrolled between 2007 and 2009 into the randomized FHN Daily trial in the East Coast consortium were approached for participation. Predialysis plasma samples were processed with metaphosphoric acid and frozen at − 70 °C for measurement with HPLC. Regression models between baseline log-transformed vitamin C and hemoglobin, CRP, eKt/V, ePCR and PTH, and a linear mixed-effects model to estimate the effect size of more frequent HD on plasma vitamin C, were constructed. We studied 44 subjects enrolled in the FHN Daily trial (50 ± 12 years, 36% female, 29% Hispanics and 64% blacks, 60% anuric). Vitamin C correlated significantly with predialysis hemoglobin (r = 0.3; P = 0.03) and PTH (r = − 0.3, P = 0.04), respectively. Vitamin C did not significantly differ at baseline (6×/week, 25.8 ± 25.9 versus 3×/week, 32.6 ± 39.4 μmol/L) and no significant treatment effect on plasma vitamin C concentrations was found [− 26.2 (95%CI -57.5 to 5.1) μmol/L at Month 4 and − 2.5 (95%CI -15.6 to 10.6) μmol/L at Month 12. Based on data from this large randomized-controlled trial no significant effect of the intervention on circulating plasma vitamin C concentrations was found, allaying the concerns that more frequent HD would affect the concentrations of water-soluble vitamins and adversely affect patient’s well-being. Correlations between vitamin C and hemoglobin and PTH support the importance of vitamin C for normal bone and mineral metabolism, and anemia management.
- Open Access
- 6 November 2018
- Published by Springer Nature in BMC Nephrology
- Vol. 19 (1) , 310
The value of non-invasive measurement of cardiac output and total peripheral resistance to categorize significant changes of intradialytic blood pressure: a prospective study
Blood pressure (BP) is currently the main hemodynamic parameter used to assess the influence of fluid removal during hemodialysis session. Since BP is dependent on cardiac output (CO) and total peripheral resistance (TPRI), investigating these parameters may help to better understand the influence of fluid removal on patient’s hemodynamics. We used a novel non-invasive whole-body bio-impedance cardiography device, recently validated in hemodialysis patients, to examine mechanisms of intradialytic hemodynamics in a Chinese dialysis population. Chronic hemodialysis patients in Sichuan Provincial People’s Hospital were enrolled. Demographic data and dialysis prescriptions were collected. Hemodynamic measurements were made pre-treatment, every 20 min during treatment and immediately after treatment in each random dialysis session. These included blood pressure, cardiac index (CI), total peripheral resistance (TPRI) and cardiac power index (CPI). Patients were divided into 5 hemodynamic groups as per their major hemodynamic response to fluid removal: low CPI, low TPRI, high TPRI, High CPI and those with normal hemodynamics. Twenty-seven patients were enrolled, with 12 (44.4%) males. The average age was 65 ± 12 y. The average body mass index (BMI) was 23.7 ± 3.9 kg/m2. 12 (44.4%) patients were diabetic. Three hundred twenty-four hemodynamic measurements were made. Weight, BMI, total fluid removal, pretreatment systolic BP, CI, TPRI and CI differed significantly among the 5 hemodynamic groups.11.1% of patients had low CPI, 25.9% had low TPRI, 18.5% had high CPI, 3.7% had high TPRI and 40.7% had normal hemodynamics. Hemodynamic differences among the 5 subgroups were significant. This technology provides multi-dimensional insight into intradialytic hemodynamic parameters, which may be more informative than blood pressure only. Using hemodynamic parameters to describe patients’ status is more specific and accurate, and could help to work out specific and effective therapeutic actions according to underlying abnormalities.
- 6 November 2018
- Published by Springer Nature in BMC Nephrology
- Vol. 19 (1) , 310
Open AccessThe value of non-invasive measurement of cardiac output and total peripheral resistance to categorize significant changes of intradialytic blood pressure: a prospective study
Blood pressure (BP) is currently the main hemodynamic parameter used to assess the influence of fluid removal during hemodialysis session. Since BP is dependent on cardiac output (CO) and total peripheral resistance (TPRI), investigating these parameters may help to better understand the influence of fluid removal on patient’s hemodynamics. We used a novel non-invasive whole-body bio-impedance cardiography device, recently validated in hemodialysis patients, to examine mechanisms of intradialytic hemodynamics in a Chinese dialysis population. Chronic hemodialysis patients in Sichuan Provincial People’s Hospital were enrolled. Demographic data and dialysis prescriptions were collected. Hemodynamic measurements were made pre-treatment, every 20 min during treatment and immediately after treatment in each random dialysis session. These included blood pressure, cardiac index (CI), total peripheral resistance (TPRI) and cardiac power index (CPI). Patients were divided into 5 hemodynamic groups as per their major hemodynamic response to fluid removal: low CPI, low TPRI, high TPRI, High CPI and those with normal hemodynamics. Twenty-seven patients were enrolled, with 12 (44.4%) males. The average age was 65 ± 12 y. The average body mass index (BMI) was 23.7 ± 3.9 kg/m2. 12 (44.4%) patients were diabetic. Three hundred twenty-four hemodynamic measurements were made. Weight, BMI, total fluid removal, pretreatment systolic BP, CI, TPRI and CI differed significantly among the 5 hemodynamic groups.11.1% of patients had low CPI, 25.9% had low TPRI, 18.5% had high CPI, 3.7% had high TPRI and 40.7% had normal hemodynamics. Hemodynamic differences among the 5 subgroups were significant. This technology provides multi-dimensional insight into intradialytic hemodynamic parameters, which may be more informative than blood pressure only. Using hemodynamic parameters to describe patients’ status is more specific and accurate, and could help to work out specific and effective therapeutic actions according to underlying abnormalities.
- Open Access
- 14 April 2018
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 33 (9) , 1643-1649
Hemodynamic response to fluid removal during hemodialysis: categorization of causes of intradialytic hypotension
Intradialytic hypotension is a clinically significant problem, however, the hemodynamics that underlie ultrafiltration and consequent hypotensive episodes has not been studied comprehensively. Intradialytic cardiac output, cardiac power and peripheral resistance changes from pretreatment measurements were evaluated using a novel regional impedance cardiographic device (NICaS, NI Medical, Peta Tikva, Israel) in 263 hemodialysis sessions in 54 patients in dialysis units in the USA and Brazil with the goal of determining the various hemodynamic trends as blood pressure decreases. Hypotensive episodes occurred in 99 (13.5%) of 736 intra- and postdialytic evaluations. The hemodynamic profiles of the episodes were categorized: (i) The cardiac power index significantly decreased in 35% of episodes by 36%, from 0.66 [95% confidence interval (CI) 0.60–0.72] to 0.43 (95% CI 0.37–0.48) [w/m2] with a small reduction in the total peripheral resistance index. (ii) The total peripheral resistance index significantly decreased in 37.4% of episodes by 33%, from 3342 (95% CI 2824–3859) to 2251 (95% CI 1900–2602) [dyn × s/cm5 × m2] with a small reduction in the cardiac power index. (iii) Both the cardiac power index and total peripheral resistance index significantly decreased in 27.3% of episodes, the cardiac power index by 25% from 0.63 (95% CI 0.57–0.70) to 0.48 (95% CI 0.42–0.53) [w/m2] and the total peripheral resistance index by 23% from 2964 (95% CI 2428–3501) to 2266 (95% CI 1891–2642). The hemodynamic profiles clearly define specific hemodynamic mechanisms of cardiac power reduction and/or vasodilatation as underlying intradialytic hypotensive episodes. A reduction in cardiac power (reduction of both blood pressure and cardiac output) could be the result of preload reduction due to a high ultrafiltration rate with not enough refilling or low target weight. A reduction in peripheral resistance (reduction in blood pressure and increase in cardiac output) could be the result of relative vasodilatation as arteries do not contract to compensate for volume reduction due to autonomous dysfunction. As both phenomena are independent, they may appear at the same time. Based on these results, a reduction of ultrafiltration rate and an increase in target weight to improve preload or immediate therapeutic actions to increase peripheral resistance are rational measures that could be taken to maintain blood pressure and prevent hypotensive ischemic complications in dialysis patients.
- 14 April 2018
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 33 (9) , 1643-1649
Open AccessHemodynamic response to fluid removal during hemodialysis: categorization of causes of intradialytic hypotension
Intradialytic hypotension is a clinically significant problem, however, the hemodynamics that underlie ultrafiltration and consequent hypotensive episodes has not been studied comprehensively. Intradialytic cardiac output, cardiac power and peripheral resistance changes from pretreatment measurements were evaluated using a novel regional impedance cardiographic device (NICaS, NI Medical, Peta Tikva, Israel) in 263 hemodialysis sessions in 54 patients in dialysis units in the USA and Brazil with the goal of determining the various hemodynamic trends as blood pressure decreases. Hypotensive episodes occurred in 99 (13.5%) of 736 intra- and postdialytic evaluations. The hemodynamic profiles of the episodes were categorized: (i) The cardiac power index significantly decreased in 35% of episodes by 36%, from 0.66 [95% confidence interval (CI) 0.60–0.72] to 0.43 (95% CI 0.37–0.48) [w/m2] with a small reduction in the total peripheral resistance index. (ii) The total peripheral resistance index significantly decreased in 37.4% of episodes by 33%, from 3342 (95% CI 2824–3859) to 2251 (95% CI 1900–2602) [dyn × s/cm5 × m2] with a small reduction in the cardiac power index. (iii) Both the cardiac power index and total peripheral resistance index significantly decreased in 27.3% of episodes, the cardiac power index by 25% from 0.63 (95% CI 0.57–0.70) to 0.48 (95% CI 0.42–0.53) [w/m2] and the total peripheral resistance index by 23% from 2964 (95% CI 2428–3501) to 2266 (95% CI 1891–2642). The hemodynamic profiles clearly define specific hemodynamic mechanisms of cardiac power reduction and/or vasodilatation as underlying intradialytic hypotensive episodes. A reduction in cardiac power (reduction of both blood pressure and cardiac output) could be the result of preload reduction due to a high ultrafiltration rate with not enough refilling or low target weight. A reduction in peripheral resistance (reduction in blood pressure and increase in cardiac output) could be the result of relative vasodilatation as arteries do not contract to compensate for volume reduction due to autonomous dysfunction. As both phenomena are independent, they may appear at the same time. Based on these results, a reduction of ultrafiltration rate and an increase in target weight to improve preload or immediate therapeutic actions to increase peripheral resistance are rational measures that could be taken to maintain blood pressure and prevent hypotensive ischemic complications in dialysis patients.