Andrzej Sierakowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrzej Sierakowski has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Piotr Grabiec
Institute of Electron Technology (Poland)
3 shared publications- Rafał Dobrowolski
Institute of Electron Technology (Poland)
3 shared publications - Teodor Gotszalk
Wrocław University of Science and Technology
3 shared publications Daniel Kopiec
Wroclaw Univ. of Technology (Poland)
2 shared publicationsPaweł Janus
Institute of Electron Technology (Poland)
2 shared publications- Teodor Gotszalk
Wroclaw Univ. of Technology (Poland)
2 shared publications
Latest Publications
- Open Access
- 23 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 915
Force Spectroscopy with Quantitative On-Cantilever Force Control
In this work we propose a method for on-cantilever force control for application in force distance (F-z) spectroscopy for intermolecular interaction sensing. In this method we perform the F-z measurements with cantilevers integrating functionalized spheres attached to them. The F-z curve is obtained by controlling the Lorentz force acting at the cantilever free end. The intermolecular interaction forces are measured by measuring the force necessary to retract the cantilever from the surface. The required force is generated by the current passing through the cantilever. In this scenario we monitor the bending of cantilevers using optical beam deflection (OBD) method. Moreover, as deflection of the cantilever was electromagnetically controlled it was possible to calibrate the OBD response as well.
- 23 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 915
Open AccessForce Spectroscopy with Quantitative On-Cantilever Force Control
In this work we propose a method for on-cantilever force control for application in force distance (F-z) spectroscopy for intermolecular interaction sensing. In this method we perform the F-z measurements with cantilevers integrating functionalized spheres attached to them. The F-z curve is obtained by controlling the Lorentz force acting at the cantilever free end. The intermolecular interaction forces are measured by measuring the force necessary to retract the cantilever from the surface. The required force is generated by the current passing through the cantilever. In this scenario we monitor the bending of cantilevers using optical beam deflection (OBD) method. Moreover, as deflection of the cantilever was electromagnetically controlled it was possible to calibrate the OBD response as well.
- 22 December 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101750Z-101750Z-6
16-element photodiode array for the angular microdeflection detector and for stabilization of a laser radiation direction
- 22 December 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101750Z-101750Z-6
16-element photodiode array for the angular microdeflection detector and for stabilization of a laser radiation direction
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 92360A-92360A-8
Shear force microscopy using piezoresistive cantilevers in surface metrology
- 16 September 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 92360A-92360A-8
Shear force microscopy using piezoresistive cantilevers in surface metrology
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 955-958
Electromagnetically Actuated Microcantilever for Chemical and Biochemical Sensing in Static Mode
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 955-958
Open AccessElectromagnetically Actuated Microcantilever for Chemical and Biochemical Sensing in Static Mode
- 25 July 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8902
Fabrication and measurement of micromechanical bridge structures for mass change detection
Microelectromechanical systems (MEMS) and nanoelectromechanical systems (NEMS) are the promising platforms for mass change observations. These systems in optimal solutions allow to observe the deposition of single molecules. This is achieved by the structure miniaturization which entails increase of resolution. In this paper, we present fabrication process of silicon nitride double-clamped beam structures. Moreover, it is presented the basic description of the beam mechanics which is based on the Euler-Bernoulli beam theory. Additionally results of the measurements of the fabricated devices are shown. Thanks to the possibility of recording force curves at nanometer deflections using atomic force microscopy (AFM) system there is a possibility to determine the properties of the MEMS and/or NEMS devices. The obtained experimental results show that the parameters of the fabricated structures differ basing on the theoretical ones, which were calculated from the elasticity theory. This results from the stress in the silicon nitride film, which forms the elastic beam structure and from the stress in the metallization deposited on the bridge. The influence of the described factors on the bridge structure properties is also described. Bridge structures with thickness of 120 nm, width and length ranging from 3 to 10 μm and from 20 μm to 80 μm respectively were investigated.
- 25 July 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8902
Fabrication and measurement of micromechanical bridge structures for mass change detection
Microelectromechanical systems (MEMS) and nanoelectromechanical systems (NEMS) are the promising platforms for mass change observations. These systems in optimal solutions allow to observe the deposition of single molecules. This is achieved by the structure miniaturization which entails increase of resolution. In this paper, we present fabrication process of silicon nitride double-clamped beam structures. Moreover, it is presented the basic description of the beam mechanics which is based on the Euler-Bernoulli beam theory. Additionally results of the measurements of the fabricated devices are shown. Thanks to the possibility of recording force curves at nanometer deflections using atomic force microscopy (AFM) system there is a possibility to determine the properties of the MEMS and/or NEMS devices. The obtained experimental results show that the parameters of the fabricated structures differ basing on the theoretical ones, which were calculated from the elasticity theory. This results from the stress in the silicon nitride film, which forms the elastic beam structure and from the stress in the metallization deposited on the bridge. The influence of the described factors on the bridge structure properties is also described. Bridge structures with thickness of 120 nm, width and length ranging from 3 to 10 μm and from 20 μm to 80 μm respectively were investigated.
- 25 July 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8902
Microfabricated support structures for investigations of mechanical and electrical graphene properties
In this work we present the grid of microstructures which is used for the graphene mechanical and electrical properties investigations. The design of the mask used for the grid production was presented. Afterwards the technological process steps for the grid production were described. In result the support structures – trenches – in shape of lines, squares and circles are obtained with the detail dimensions varied from 1 micrometer up to 30 micrometers. Examples of graphite and graphene deposited on the support structures are also presented.
- 25 July 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8902
Microfabricated support structures for investigations of mechanical and electrical graphene properties
In this work we present the grid of microstructures which is used for the graphene mechanical and electrical properties investigations. The design of the mask used for the grid production was presented. Afterwards the technological process steps for the grid production were described. In result the support structures – trenches – in shape of lines, squares and circles are obtained with the detail dimensions varied from 1 micrometer up to 30 micrometers. Examples of graphite and graphene deposited on the support structures are also presented.