SKSvenja Knappe

Svenja Knappe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Svenja Knappe has a total of 131 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accurate vector magnetometer via Zeeman Rabi oscillations

    by T. S. Menon, D. P. Hewatt, C. Kiehl, M. Ellmeier, S. Knappe, C. A. Regal

  • Investigating the hyperfine systematic error and relative phase in low-spin-polarization alkali-metal free-induction-decay magnetometers

    by D. P. Hewatt, M. Ellmeier, C. Kiehl, T. S. Menon, J. W. Pollock, C. A. Regal, S. Knappe

    The authors present model as well as experimental results for free-induction-decay magnetometer accuracy in the presence of variable ground-state spin polarization, an important step in quantifying, reducing, or removing significant systematic shifts in finite-magnetic-field sensing. The techniques described in the paper are expected to significantly improve the accuracy of such sensors under limited optical power conditions.


  • Open Access

    Coherence of Rabi oscillations with spin exchange

    by Chris Kiehl, Daniel Wagner, Ting-Wei Hsu, Svenja Knappe, Cindy A. Regal, Tobias Thiele

    Rabi measurements in atomic vapor cells are of current interest in a range of microwave imaging and sensing experiments, but are increasingly in a parameter space outside of theoretical studies of coherence defined by spin-exchange collisions. Here, we study the coherence of Rabi oscillations in vapor cells by employing continuous non-destructive readout of the hyperfine manifold of $^{87}$Rb using Faraday rotation. We develop a full model for spin-exchange (SE) coherence for hyperfine transitions that takes into account a non-static population distribution. In this regime, Rabi oscillations exhibit nontrivial time-domain signals that allow verification of vapor-cell parameters. We find excellent agreement between theory and experiment, which will aid in benchmarking sensitivities of Rabi measurement applications.

  • Open Access

    Magnetic communication by polarization helicity modulation using atomic magnetometers

    by Isaac Fan, Svenja Knappe, Vladislav Gerginov

    The radio frequency telecommunication at a kilohertz range through an electrically conductive medium is often impeded by the strong reflection and absorption at the interface. The polarization helicity of the magnetic field can be modulated/demodulated to provide a new communication protocol to potentiality circumvent these issues. Here, a miniature magnetic quantum receiver, capable of simultaneously discriminating the two possible helicities of a magnetic field, is presented. The core physics package constitutes two optically pumped atomic magnetometers. It is shown that a data rate of 500 bits/s with a carrier frequency of 2 kHz can be efficiently demodulated in an unshielded environment, paving a promising route for the future of radio frequency communication through a conductive barrier.


  • Open Access

    A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding

    by Richard J Clancy, Vladislav Gerginov, Orang Alem, Stephen Becker, Svenja Knappe

    Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background fields making them ideally suited for brain imaging applications in unshielded environments. Despite a flurry of activity around the topic, questions remain concerning how well a dipolar source can be localized under such conditions, especially when using few sensors. In this paper, we investigate the source localization capabilities using an array of scalar OPMs in the presence of a large background field while varying dipole strength, sensor count, and forward model accuracy. We also consider localization performance as the orientation angle of the background field changes. Our results are validated experimentally through accurate localization using a phantom virtual array mimicking a current dipole in a conducting sphere in a large background field. Our results are intended to give researchers a general sense of the capabilities and limitations of scalar OPMs for magnetoencephalography systems.


  • Open Access

    A conformal array of microfabricated optically-pumped first-order gradiometers for magnetoencephalography

    by N. V. Nardelli, A. R. Perry, S. P. Krzyzewski, S. A. Knappe

    An array of 21 first-order gradiometers based on zero-field optically-pumped magnetometers is demonstrated for use in magnetoencephalography. Sensors are oriented radially with respect to the head and housed in a helmet with moveable holders which conform to the shape of a scalp. Our axial gradiometers have a baseline of 2 cm and reject laser and vibrational noise as well as common-mode environmental magnetic noise. The median sensitivity of the array is 15.4 fT/Hz1/2, measured in a human-sized magnetic shield. All magnetometers are operated independently with negative feedback to maintain atoms at zero magnetic field. This yields higher signal linearity and operating range than open-loop operation and a measurement system that is less sensitive to systematic and ambient magnetic fields. All of the system electronics and lasers are compacted into one equipment rack which offers a favorable outlook for use in clinical settings.


  • Scalar Magnetometry Below 100 fT/Hz1/2 in a Microfabricated Cell

    by Vladislav Gerginov, Marco Pomponio, Svenja Knappe

    Zero-field optically-pumped magnetometers are a room-temperature alternative to traditionally used superconducting sensors detecting extremely weak magnetic fields. They offer certain advantages such as small size, flexible arrangement, reduced sensitivity in ambient fields offering the possibility for telemetry. Devices based on microfabricated technology are nowadays commercially available. The limited dynamic range and vector nature of the zero-field magnetometers restricts their use to environments heavily shielded against magnetic noise. Total-field (or scalar) magnetometers based on microfabricated cells have demonstrated subpicotesla sensitivities only recently. This work demonstrates a scalar magnetometer based on a single optical axis, 18 ( $3\times 3\times 2$ )mm 3 microfabricated cell, with a noise floor of 70 fT/Hz 1/2 . The magnetometer operates in a large static magnetic field range, and and is based on a simple optical and electronic configuration that allows the development of dense sensor arrays. Different methods of magnetometer interrogation are demonstrated. The features of this magnetic field sensor hold promise for applications of miniature sensors in nonzero field environments such as unshielded magnetoencephalography (MEG) and brain-computer interfaces (BCI).


  • Reducing crosstalk in optically-pumped magnetometer arrays

    by N V Nardelli, S P Krzyzewski, S A Knappe

    Optically pumped magnetometers (OPMs) operating in the spin-exchange relaxation-free regime are emerging as alternative sensors to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). As the number of OPMs in a single imaging system increases to rival SQUID MEG systems, cross-talk between nearby sensors limits the measurement accuracy. We experimentally demonstrate a coil geometry, which generates an order of magnitude less cross-talk (less than 0.5%) than a Helmholtz coil (8%). The new coil design is simple and compact, requiring two coaxial coil pairs that add 1 mm to the 6 mm radius and is driven by a single current driver. The new design maintains a magnetic field homogeneity over the volume of the magnetometer of more than 94%, which is sufficient for the zero-field OPM to operate in a 200 nT ambient field environment. Our result increases the feasibility of high-spatial resolution OPM-based bio-magnetic imaging technology due to the reduction of cross-talk at high sensor density.


  • Optically Pumped Magnetometers for MEG

    by Svenja Knappe, Tilmann Sander, Lutz Trahms