CDClaire Dazon

Claire Dazon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Claire Dazon has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fe/N/C Catalyst Production by Collinear CO2 Laser Pyrolysis: Toward a Specific Mass-Weighted Energy-Deposited (J.g−1) Parameter Opening Discussion on FeNx Site Formation

    by Henri Perez, Claire Dazon, Pierre Lonchambon, Suzy Surblé, Emeline Charon, Mathieu Frégnaux, Arnaud Etcheberry, Charles Rivron, Olivier Sublemontier

    We report the synthesis of Fe/N/C ORR electrocatalysts by an original collinear CO2 laser pyrolysis of liquid aerosol droplets in various configurations and compared them to a catalyst synthesized in the classical perpendicular one. While the precursors were always injected at the bottom side of the reactor, two collinear configurations of the laser entry into the reactor are considered: by the Top Side (T.S.) or by the Bottom Side (B.S.). The two corresponding catalysts sets show significant different ORR performances. An in-depth XPS analysis and fitting of the N1s spectra allowed for drawing the ORR performance as a function of FeNx sites components. An original approach considering the energy delivered to a quantity of precursors in J.g−1, linked to the flame temperature feature, evidenced very different conditions for perpendicular CO2 laser pyrolysis and each of the two collinear configurations. This mass-weighted energy delivered in the classical perpendicular configuration is too low to allow for the formation of FeNx sites and the resulting ORR performance is extremely poor, suggesting a marginal role of nitrogen species without interaction with iron atoms. In contrast, the delivered mass-weighted energies are sufficient in both collinear configurations to produce FeNx sites. The ORR performance for catalysts produced in these both configurations is positively correlated with the amount of energy deposited on the precursors. The ORR performance in the T.S. laser configuration is positively correlated to the amount of FeNx sites. The best performing catalysts obtained in the B.S. configuration show an opposite variation. These trends, and the ORR performance degradation of B.S. catalysts under prolonged chronoamperometry are discussed in light of the effect of temperature on the formation of the various kind of FeNx sites. A tentative explanation is given, considering that N1s XPS fitting with a single FeNx component may hinder the fact that Pyridinic sites components may contain a part of FeNx sites, as suggested by theoretical calculation from the literature. The best catalysts obtained in this work by collinear configuration show similar performances to those obtained by double stage perpendicular pyrolysis previously reported with an ORR onset potential of ~860 mV.

  • Open Access

    Biofuels and hydrogen production: back to the Langmuir–Blodgett approach for large-scale structuration of Bi-based photoelectrodes

    by Claire Dazon, Márcio César Pereira, Douglas Santos Monteiro

    This perspective article highlights the good potentiality for the Langmuir Blodgett technique to produce massively BiVO4 based photoelectrodes for biomass valorization and hydrogen production in the context of Brazil's decarbonation.


  • Open Access

    Layered double hydroxides: where should research stress on for massive scaling up?

    by Claire Dazon, Christine Taviot-Guého, Vanessa Prévot

    This perspective highlights the potentiality for co-precipitation and mechanosynthesis to produce massively layered double hydroxides for disruptive applications providing several gaps are addressed, notably the control of the particle agglomeration.


  • Towards a surface metric to measure the dustiness of nanomaterial powders

    by Claire Dazon, Sébastien Bau, Raphaël Payet, Vanessa Fierro, Olivier Witschger

    The relevance of dustiness methods is increasingly recognized in the preliminary exposure evaluation of workers handling nanomaterials in powder form, and should also be transposed to the assessment of environmental risk in the future. The methods currently recommended in the European standards are mainly based on determining a mass-based dustiness index [mg kg−1], whereas surface area is regularly put forward as a more appropriate determinant to assess the pulmonary toxicity of nanoparticles. In this study, we describe an operational methodology leading us to propose a surface metric to determine the dustiness index [m2 kg−1] of nanoparticulate matter. To this end, we demonstrate the equivalence between the external specific surface area of a nanopowder and that of its aerosol with five nanomaterials produced and used on an industrial scale, and covering a range of external specific surface areas from 35 to 230 m2 g−1. Compared to the conventional mass-based dustiness index, the surface-based dustiness index (1) is more discriminating, covering an additional order of magnitude, and (2) has an impact on the powder ranking with potential consequences on the preventive measures to be implemented. Finally, our proposal has the potential to be included in future revisions of European standards for workplace exposure and dustiness measurement, provided that further experimental results on surface-based dustiness indices support these preliminary data.


  • Open Access

    Identification of nanomaterials by the volume specific surface area (VSSA) criterion: application to powder mixes

    by Claire Dazon, Vanessa Fierro, Alain Celzard, Olivier Witschger

    We demonstrate the relevance of the Volume Specific Surface Area (VSSA) parameter to identify the nanoparticulate character of powder mixes based on either spherical constituent particles with bimodal size distributions (TiO2), or fiber-like constituent particles with unimodal size distributions (sepiolite and sepiolite-based pigments). These new results indicate that VSSA could reasonably be proposed as an optional criterion in the future for the definition of nanomaterials based on the European Commission recommendation, provided certain requirements are fulfilled.


  • Open Access

    Toward an operational methodology to identify industrial-scaled nanomaterial powders with the volume specific surface area criterion

    by Claire Dazon, Olivier Witschger, Sébastien Bau, Vanessa Fierro, Philip L. Llewellyn

    Nanoparticulate powders are increasingly found in the workplace. Inhalation exposure to airborne nanoparticles (NPs) is possible throughout the life-cycle of the powders. As the toxicity of NPs has never been demonstrated, it remains essential to evaluate the risks associated with NPs in order to propose preventative measures. The first step of a risk assessment strategy consists in the identification of the ‘nano’ nature of a material, which suffers from a lack of an operational methodology. Here, we present a simplified and operational strategy relying on the volume specific surface area (VSSA) for nanomaterial identification, based on the recommendation stemming from the European Commission and previous work on this topic from the European Project Nanodefine. The proposed strategy was tested on a set of 15 representative industrial powders (TiO2, SiO2, CuO, and ZnO), covering a wide range of properties, and previous published data. The VSSA classification was validated via a comparison with the particle size obtained by transmission electron microscopy (TEM). It was evidenced that the VSSA is in accordance with particle size for nanomaterial powder classification. The proposed methodology involves relatively accessible methods such as thermogravimetric analysis, nitrogen adsorption and helium pycnometry and limits the detection of false negatives. Moreover, it does not imply systematic confirmation of the results with the reference particle size criterion. Our results suggest that the VSSA is a promising parameter to be used for risk assessment and should be further investigated on powder mixings to confirm its relevancy to define nanomaterial powders.


  • Nanomaterial identification of powders: comparing volume specific surface area, X-ray diffraction and scanning electron microscopy methods

    by Claire Dazon, Olivier Witschger, Sébastien Bau, Vanessa Fierro, Philip L. Llewellyn

    Nanomaterials in powder forms are widely produced and used in numerous applications. Nanomaterial identification is a growing concern for several areas encountering these substances. The current reference criterion of the European Commission (EC) for nanoparticle identification is the number size distribution of the constituent particles. One example of how the latter can be obtained is by the electron microscopy (EM) method. However, this method is not widely available and is time-consuming to perform and use for analysis. Alternative methods, such as the volume specific surface area (VSSA), also allow nanomaterial identification. The VSSA is the product of the external specific surface area of the powder and its skeletal density, and appears to be adapted more specifically for powders. The techniques required to measure the two parameters used to calculate the VSSA are more widely available than EM, but sample preparation can be delicate. Furthermore, deeper evaluation of the reliability of VSSA for nanomaterial classification as well as a more detailed characterization methodology for its implementation and discussion about the relative merits of this method versus EM are still necessary. Here, we determined, through a detailed and operational characterization strategy, the VSSA for seven metal oxide powders (4 TiO2, 1 SiO2, and 2 CaCO3) and an activated carbon, with all of them produced on an industrial scale. These eight samples covered a range of constituent particle sizes between 10 nm and 18 μm. Equivalent particle sizes determined by the VSSA, X-ray diffraction (XRD) (another method giving access to an equivalent particle size and integrated into our characterization methodology) and scanning electron microscopy (SEM) (reference method) were compared. The results showed that the VSSA can robustly identify nanomaterials in the form of powders (−12% mean bias on equivalent particle sizes relative to SEM).