Hector Alva Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hector Alva Sánchez has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
A. Martínez-Dávalos
Institute of Physics, National Autonomous University of Mexico, Mexico City, Mexico
9 shared publicationsM. Rodríguez-Villafuerte
Institute of Physics, National Autonomous University of Mexico, Mexico City, Mexico
8 shared publications- Mercedes Rodríguez-Villafuerte
Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica, Ciudad Universitaria, Mexico City, Mexico
7 shared publications - Arnulfo Martínez-Dávalos
Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica, Ciudad Universitaria, Mexico City, Mexico
6 shared publications T. Murrieta-Rodríguez
6 shared publicationsC. Ruiz-Trejo
Instituto de Física, Universidad Nacional Autónoma de México, Mexico City, Mexico
4 shared publications
Latest Publications
- Open Access
- 6 August 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Non-proportionality measurement of rare earth-based scintillators using a triple coincidence Compton spectrometer
- 6 August 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Open AccessNon-proportionality measurement of rare earth-based scintillators using a triple coincidence Compton spectrometer
- Open Access
- 22 May 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3)
Magnetic field effects on positron range and image quality in PET/MR
This study investigates the influence of strong magnetic fields on the transport of positrons emitted by 18F and 68Ga and how these effects propagate to image quality metrics in tissue-equivalent phantoms relevant to PET/MR imaging. Monte Carlo simulations were performed using PENELOPE 2018, a well-established code for detailed low-energy radiation transport. Although electromagnetic fields are not directly implemented in its main code, the appropriate subroutines were combined to enable tracking of positrons up to annihilation in uniform magnetic fields of 0, 3, and 9 T. Simulations were carried out in four representative media (lung, soft tissue, water, and cortical bone) as well as in NEMA-like image quality phantoms used in a clinical PET/MR experimental study, to assess the impact of the magnetic fields on image quality and radiopharmaceutical quantification. The results demonstrate that positron range significantly affects recovery coefficients and spill-over ratios in NEMA-like image quality phantoms, particularly for high-energy positron emitters in low-density tissues, such as 68Ga in lung. Even under ideal Monte Carlo conditions, full signal recovery is never achieved, and recovery coefficients remain below unity due to the finite positron range. Spillover ratio results depend on the size of the volumes of interest in air cavities, as partial volume effects compromise quantitative accuracy. The magnetic field reduces these effects in the direction perpendicular to the field lines, leading to improved spatial resolution and quantitative accuracy in PET/MR. At 9 T, the dependence of positron range on tissue density is substantially reduced. These findings establish fundamental limits on image quality imposed by positron range in the presence of uniform magnetic fields, independent of detector technology or reconstruction algorithms. They provide a physical basis for the development of positron-range correction methods in PET/MR and offer quantitative insight into the potential benefits of ultra-high-field (9 T) PET/MR systems.
- 22 May 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3)
Open AccessMagnetic field effects on positron range and image quality in PET/MR
This study investigates the influence of strong magnetic fields on the transport of positrons emitted by 18F and 68Ga and how these effects propagate to image quality metrics in tissue-equivalent phantoms relevant to PET/MR imaging. Monte Carlo simulations were performed using PENELOPE 2018, a well-established code for detailed low-energy radiation transport. Although electromagnetic fields are not directly implemented in its main code, the appropriate subroutines were combined to enable tracking of positrons up to annihilation in uniform magnetic fields of 0, 3, and 9 T. Simulations were carried out in four representative media (lung, soft tissue, water, and cortical bone) as well as in NEMA-like image quality phantoms used in a clinical PET/MR experimental study, to assess the impact of the magnetic fields on image quality and radiopharmaceutical quantification. The results demonstrate that positron range significantly affects recovery coefficients and spill-over ratios in NEMA-like image quality phantoms, particularly for high-energy positron emitters in low-density tissues, such as 68Ga in lung. Even under ideal Monte Carlo conditions, full signal recovery is never achieved, and recovery coefficients remain below unity due to the finite positron range. Spillover ratio results depend on the size of the volumes of interest in air cavities, as partial volume effects compromise quantitative accuracy. The magnetic field reduces these effects in the direction perpendicular to the field lines, leading to improved spatial resolution and quantitative accuracy in PET/MR. At 9 T, the dependence of positron range on tissue density is substantially reduced. These findings establish fundamental limits on image quality imposed by positron range in the presence of uniform magnetic fields, independent of detector technology or reconstruction algorithms. They provide a physical basis for the development of positron-range correction methods in PET/MR and offer quantitative insight into the potential benefits of ultra-high-field (9 T) PET/MR systems.
- 1 January 2025
- Published by Universidad Nacional Autonoma de Mexico
Diseño y fabricación de un Conversor NIM a TTL con ajuste de anchura y retardo
En los experimentos que se realizan en los laboratorios de física, por lo regular es necesario conectardiversos tipos de equipos o módulos electrónicos con la finalidad de acondicionar las señales queprovienen de diversos tipos de sensores. Este acondicionamiento se realiza de manera que los pulsoselectrónicos tengan la forma y amplitud adecuada para que puedan digitalizarse y posteriormenteprocesarse en una computadora. En algunas situaciones las señales lógicas de algunos módulos deinstrumentación nuclear (NIM por sus siglas en inglés) deban usarse para activar equipos cuyas entradasrequieren niveles lógicos de transistor-a-transistor (TTL por sus siglas en inglés); por ejemplo, cuando lospulsos NIM son negativos y los TTL son positivos. Para solventar esta incompatibilidad de niveles lógicoses necesario emplear un circuito electrónico que convierta las señales NIM a TTL. En este reporte sedescribe el diseño electrónico un conversor NIM a TTL con ajuste de anchura y retardo. El trabajorealizado incluye el diseño y fabricación de la tarjeta de circuito impreso (PCB por sus siglas en inglés),cuyas dimensiones fueron elegidas para permitir su conexión directa a una tarjeta de desarrollo ArduinoUNO. A la PCB se le realizaron pruebas de continuidad, aislamiento y cortocircuito. Posteriormente, trasla colocación de los componentes electrónicos, se midió el consumo de energía conectándola a unatarjeta de desarrollo Arduino UNO.El circuito conversor se opera mediante una interfaz gráfica de usuario, la cual permite controlar lospotenciómetros digitales responsables de modificar los parámetros de retardo y anchura del pulso desalida. Para evaluar el desempeño, se le inyectaron señales usando un generador de funciones, y seanalizaron las señales de salida TTL en un osciloscopio. Esto con la finalidad de verificar que: a) los nivelesde voltaje son adecuados, b) se puedan introducir retardos respecto a la señal de entrada y c) se puedamodificar la anchura dentro de un intervalo de tiempo especifico. Como prueba final, y con el propósitode verificar el funcionamiento correcto del conversor, se conectó a un arreglo de módulos NIM pararealizar adquisiciones en coincidencia temporal.
- 1 January 2025
- Published by Universidad Nacional Autonoma de Mexico
Diseño y fabricación de un Conversor NIM a TTL con ajuste de anchura y retardo
En los experimentos que se realizan en los laboratorios de física, por lo regular es necesario conectardiversos tipos de equipos o módulos electrónicos con la finalidad de acondicionar las señales queprovienen de diversos tipos de sensores. Este acondicionamiento se realiza de manera que los pulsoselectrónicos tengan la forma y amplitud adecuada para que puedan digitalizarse y posteriormenteprocesarse en una computadora. En algunas situaciones las señales lógicas de algunos módulos deinstrumentación nuclear (NIM por sus siglas en inglés) deban usarse para activar equipos cuyas entradasrequieren niveles lógicos de transistor-a-transistor (TTL por sus siglas en inglés); por ejemplo, cuando lospulsos NIM son negativos y los TTL son positivos. Para solventar esta incompatibilidad de niveles lógicoses necesario emplear un circuito electrónico que convierta las señales NIM a TTL. En este reporte sedescribe el diseño electrónico un conversor NIM a TTL con ajuste de anchura y retardo. El trabajorealizado incluye el diseño y fabricación de la tarjeta de circuito impreso (PCB por sus siglas en inglés),cuyas dimensiones fueron elegidas para permitir su conexión directa a una tarjeta de desarrollo ArduinoUNO. A la PCB se le realizaron pruebas de continuidad, aislamiento y cortocircuito. Posteriormente, trasla colocación de los componentes electrónicos, se midió el consumo de energía conectándola a unatarjeta de desarrollo Arduino UNO.El circuito conversor se opera mediante una interfaz gráfica de usuario, la cual permite controlar lospotenciómetros digitales responsables de modificar los parámetros de retardo y anchura del pulso desalida. Para evaluar el desempeño, se le inyectaron señales usando un generador de funciones, y seanalizaron las señales de salida TTL en un osciloscopio. Esto con la finalidad de verificar que: a) los nivelesde voltaje son adecuados, b) se puedan introducir retardos respecto a la señal de entrada y c) se puedamodificar la anchura dentro de un intervalo de tiempo especifico. Como prueba final, y con el propósitode verificar el funcionamiento correcto del conversor, se conectó a un arreglo de módulos NIM pararealizar adquisiciones en coincidencia temporal.
- Open Access
- 9 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 185006
Quantitative analysis of the effect of the magnetic field generated by a PET/MR scanner on positron range
Objective. Image quality (IQ) in positron emission tomography (PET) is influenced by positron range. In this work, the effect of the magnetic field of a PET/MR Siemens Biograph mMR 3 T on the quality of PET images was studied. Approach. Experimental measurements were conducted using 18F and 68Ga-filled phantoms to quantify image uniformity, recovery coefficients (RCs), spill-over ratios and percent contrast for spherical lesions. Tissue-equivalent phantoms (lung inhale and exhale, adipose, water, trabecular and cortical bone) were used together with a line source to quantify the impact of the magnetic field on the reconstructed PET images. A comparative analysis was made with images obtained with a PET/CT (computed tomography) Biograph Vision 600, using the same radionuclides and phantoms. Main results. Higher RCs values were obtained when the IQ phantom was filled with 68Ga and scanned with the PET/MR system compared to those obtained with the PET/CT scanner. Hot spheres in the lesion detectability phantom, appear contracted in the transverse direction in the PET/MR system, an effect more evident for 68Ga compared to 18F, but no elongation in the direction parallel to the magnetic field was observed. In the PET/CT scanner, radial profiles taken from axial slices of line sources, show longer distribution tails extending beyond 20 mm when filled with 68Ga and placed inside lung-inhale tissue. In the PET/MR scanner the radial profiles of all materials collapsed into a single distribution with tails extending no more than 10 mm in the direction perpendicular to the magnetic field. Significance. Positron range depends on positron energy and material density in which they traverse. The results show an evident improvement in IQ in the transaxial direction only, particularly in phantoms filled with 68Ga when using a PET/MR system as opposed to images acquired in the PET/CT system due to the presence of the magnetic field.
- 9 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 185006
Open AccessQuantitative analysis of the effect of the magnetic field generated by a PET/MR scanner on positron range
Objective. Image quality (IQ) in positron emission tomography (PET) is influenced by positron range. In this work, the effect of the magnetic field of a PET/MR Siemens Biograph mMR 3 T on the quality of PET images was studied. Approach. Experimental measurements were conducted using 18F and 68Ga-filled phantoms to quantify image uniformity, recovery coefficients (RCs), spill-over ratios and percent contrast for spherical lesions. Tissue-equivalent phantoms (lung inhale and exhale, adipose, water, trabecular and cortical bone) were used together with a line source to quantify the impact of the magnetic field on the reconstructed PET images. A comparative analysis was made with images obtained with a PET/CT (computed tomography) Biograph Vision 600, using the same radionuclides and phantoms. Main results. Higher RCs values were obtained when the IQ phantom was filled with 68Ga and scanned with the PET/MR system compared to those obtained with the PET/CT scanner. Hot spheres in the lesion detectability phantom, appear contracted in the transverse direction in the PET/MR system, an effect more evident for 68Ga compared to 18F, but no elongation in the direction parallel to the magnetic field was observed. In the PET/CT scanner, radial profiles taken from axial slices of line sources, show longer distribution tails extending beyond 20 mm when filled with 68Ga and placed inside lung-inhale tissue. In the PET/MR scanner the radial profiles of all materials collapsed into a single distribution with tails extending no more than 10 mm in the direction perpendicular to the magnetic field. Significance. Positron range depends on positron energy and material density in which they traverse. The results show an evident improvement in IQ in the transaxial direction only, particularly in phantoms filled with 68Ga when using a PET/MR system as opposed to images acquired in the PET/CT system due to the presence of the magnetic field.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2947 (1) , 030012
Attenuation and scatter quantification in positron emission mammography
Positron emission mammography (PEM) studies of high precision diagnostic quality require not only to quantify the fraction of the 511 keV annihilation photons t
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2947 (1) , 030012
Open AccessAttenuation and scatter quantification in positron emission mammography
Positron emission mammography (PEM) studies of high precision diagnostic quality require not only to quantify the fraction of the 511 keV annihilation photons t
- Open Access
Localization in Two-Dimensional Quasicrystalline Lattices
We investigate the emergence of localization in a weakly interacting Bose gas confined in quasicrystalline lattices with three different rotational symmetries: five, eight, and twelve. The analysis, performed at a mean field level and from which localization is detected, relies on the study of two observables: the inverse participation ratio (IPR) and the Shannon entropy in the coordinate space. Those physical quantities were determined from a robust statistical study for the stationary density profiles of the interacting condensate. Localization was identified for each lattice type as a function of the potential depth. Our analysis revealed a range of the potential depths for which the condensate density becomes localized, from partially at random lattice sites to fully in a single site. We found that localization in the case of five-fold rotational symmetry appears for , while it occurs in the interval for octagonal and dodecagonal symmetries.Open AccessLocalization in Two-Dimensional Quasicrystalline Lattices
We investigate the emergence of localization in a weakly interacting Bose gas confined in quasicrystalline lattices with three different rotational symmetries: five, eight, and twelve. The analysis, performed at a mean field level and from which localization is detected, relies on the study of two observables: the inverse participation ratio (IPR) and the Shannon entropy in the coordinate space. Those physical quantities were determined from a robust statistical study for the stationary density profiles of the interacting condensate. Localization was identified for each lattice type as a function of the potential depth. Our analysis revealed a range of the potential depths for which the condensate density becomes localized, from partially at random lattice sites to fully in a single site. We found that localization in the case of five-fold rotational symmetry appears for , while it occurs in the interval for octagonal and dodecagonal symmetries. - 8 April 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (14) , 144501
Background energy spectra for LSO/LYSO scintillation crystals of different geometries
The background energy spectrum of lutetium oxyorthosilicate/lutetium yttrium oxyorthosilicate scintillation crystals used in positron emission imaging systems is a research topic of great interest owing to the possibility of using its structure to perform detector calibration and quality control without the need of using external radiation sources. In this paper, the background energy spectra for crystals of different sizes and geometries, including cuboids, frusta, cylinders, tetrahedra, and spheres, have been computed. This was done using a previously developed analytical model that requires the photon absorption probabilities for each shape, obtained through simulations using the PENELOPE Monte Carlo code. It has been found that crystals of different geometries, but with the same volume-to-surface area ratio, give rise to very similar background energy spectra, simplifying its computation. In addition, simple ray tracing simulations were performed, and a robust geometrical model was devised to investigate the geometrical grounds of this practical and compelling result.
- 8 April 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (14) , 144501
Background energy spectra for LSO/LYSO scintillation crystals of different geometries
The background energy spectrum of lutetium oxyorthosilicate/lutetium yttrium oxyorthosilicate scintillation crystals used in positron emission imaging systems is a research topic of great interest owing to the possibility of using its structure to perform detector calibration and quality control without the need of using external radiation sources. In this paper, the background energy spectra for crystals of different sizes and geometries, including cuboids, frusta, cylinders, tetrahedra, and spheres, have been computed. This was done using a previously developed analytical model that requires the photon absorption probabilities for each shape, obtained through simulations using the PENELOPE Monte Carlo code. It has been found that crystals of different geometries, but with the same volume-to-surface area ratio, give rise to very similar background energy spectra, simplifying its computation. In addition, simple ray tracing simulations were performed, and a robust geometrical model was devised to investigate the geometrical grounds of this practical and compelling result.
- Open Access
- 30 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2348 (1) , 050004
Depth of interaction in monolithic scintillators for positron emission tomography
The parallax error introduced by incorrectly assigning the lines-of-response defined by the annihilation photon pairs, limits the attainable spatial resolution in positron emission imaging. Knowledge of the exact position of interaction (x, y, z) inside the scintillation crystal, including the depth of interaction z of the 511 keV photons, reduces this error. In this work, the depth of interaction (DOI) was determined in two different scintillator materials: EJ-232 plastic and LYSO scintillation crystals. These were coupled to an 8×8 silicon photomultiplier (SiPM) array. An analysis of the light distributions produced inside the crystals enabled the determination of the DOI position, allowing the correction for parallax errors. This method is expected to be used in a Positron Emission Mammography (PEM) prototype under development.
- 30 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2348 (1) , 050004
Open AccessDepth of interaction in monolithic scintillators for positron emission tomography
The parallax error introduced by incorrectly assigning the lines-of-response defined by the annihilation photon pairs, limits the attainable spatial resolution in positron emission imaging. Knowledge of the exact position of interaction (x, y, z) inside the scintillation crystal, including the depth of interaction z of the 511 keV photons, reduces this error. In this work, the depth of interaction (DOI) was determined in two different scintillator materials: EJ-232 plastic and LYSO scintillation crystals. These were coupled to an 8×8 silicon photomultiplier (SiPM) array. An analysis of the light distributions produced inside the crystals enabled the determination of the DOI position, allowing the correction for parallax errors. This method is expected to be used in a Positron Emission Mammography (PEM) prototype under development.
- 21 January 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1596-1607
Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes
Purpose: Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide range of crystal sizes.Methods: An analytical model, developed and validated in a previous work, was used to obtain the background energy spectra of square base cuboids of different dimensions. The model uses the photon absorption probabilities of the three gamma rays (88, 202, and 307 keV) emitted following the beta decay of 176Lu to 176Hf excited states. These probabilities were obtained for each crystal size considered in this work from Monte Carlo simulations using the PENELOPE code. The probabilities are then used to normalize and shift the beta spectrum to the corresponding energy value of the simultaneous detection of one, two, or three gamma rays in the scintillator. The simulated cuboids had side lengths of 5, 10, 20, 30, 40, 50, and 60 mm and crystal thickness T = 2.5, 5, 10, 15, and 20 mm. From these results a complete set of energy spectra, including intermediate dimensions, were obtained. In addition, LYSO and LSO were compared in terms of their analytical background energy spectra for two crystal sizes. The analytical spectra were convolved using a variable Gaussian kernel to account for the energy resolution of a typical detector. A parameterization of the photon absorption probabilities for each gamma ray energy as a function of the cuboid volume to surface area ratio was obtained.Results: A data set of L(Y)SO background energy spectra was obtained and is available for the reader as 2D histograms. The model accurately predicts the structure of the energy spectra including the relative peak and valley intensities. The data allow visualizing how the structure evolves with increasing crystal length and thickness. Lutetium yttrium oxyorthosilicate and LSO present very similar background energy spectra for the range of sizes studied in this work and therefore the data generated can be confidently used for both scintillator materials. The filtered spectra showed a variable shift in the main peaks, depending on crystal size, alerting that to achieve a correct detector calibration using the background spectrum is not straight forward and requires precise data analysis and measurements. In addition, we found that square base L(Y)SO cuboids with same volume to surface area ratio have background spectra with the same structure.Conclusions: We present the energy spectra of L(Y)SO crystal of different sizes which will be very useful for industry and research groups developing and simulating detectors for positron imaging applications in terms of calibration, quality assurance, crystal maps, detector fine gain tuning, background reduction and other applications using the long‐lived 176Lu source. We analyzed the data produced in this work and found that crystal cuboids with equal volume to surface area ratio produce the same background energy spectra, a conclusion that simplifies its calculation and clarifies why the same energy spectrum is observed under different experimental setups.
- 21 January 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1596-1607
Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes
Purpose: Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide range of crystal sizes.Methods: An analytical model, developed and validated in a previous work, was used to obtain the background energy spectra of square base cuboids of different dimensions. The model uses the photon absorption probabilities of the three gamma rays (88, 202, and 307 keV) emitted following the beta decay of 176Lu to 176Hf excited states. These probabilities were obtained for each crystal size considered in this work from Monte Carlo simulations using the PENELOPE code. The probabilities are then used to normalize and shift the beta spectrum to the corresponding energy value of the simultaneous detection of one, two, or three gamma rays in the scintillator. The simulated cuboids had side lengths of 5, 10, 20, 30, 40, 50, and 60 mm and crystal thickness T = 2.5, 5, 10, 15, and 20 mm. From these results a complete set of energy spectra, including intermediate dimensions, were obtained. In addition, LYSO and LSO were compared in terms of their analytical background energy spectra for two crystal sizes. The analytical spectra were convolved using a variable Gaussian kernel to account for the energy resolution of a typical detector. A parameterization of the photon absorption probabilities for each gamma ray energy as a function of the cuboid volume to surface area ratio was obtained.Results: A data set of L(Y)SO background energy spectra was obtained and is available for the reader as 2D histograms. The model accurately predicts the structure of the energy spectra including the relative peak and valley intensities. The data allow visualizing how the structure evolves with increasing crystal length and thickness. Lutetium yttrium oxyorthosilicate and LSO present very similar background energy spectra for the range of sizes studied in this work and therefore the data generated can be confidently used for both scintillator materials. The filtered spectra showed a variable shift in the main peaks, depending on crystal size, alerting that to achieve a correct detector calibration using the background spectrum is not straight forward and requires precise data analysis and measurements. In addition, we found that square base L(Y)SO cuboids with same volume to surface area ratio have background spectra with the same structure.Conclusions: We present the energy spectra of L(Y)SO crystal of different sizes which will be very useful for industry and research groups developing and simulating detectors for positron imaging applications in terms of calibration, quality assurance, crystal maps, detector fine gain tuning, background reduction and other applications using the long‐lived 176Lu source. We analyzed the data produced in this work and found that crystal cuboids with equal volume to surface area ratio produce the same background energy spectra, a conclusion that simplifies its calculation and clarifies why the same energy spectrum is observed under different experimental setups.